• Title/Summary/Keyword: Tower base

Search Result 93, Processing Time 0.019 seconds

A Study on Characteristic of Residual Stresses in a wind Tower Using the Tandem Circumferential Welding Process (Tandem 용접을 이용한 풍력타워 원주용접부 잔류응력 특성에 관한 연구)

  • Kim, Ji Sun;Kim, In Ju
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.938-945
    • /
    • 2012
  • This research proposes FEM analysis for Tandem welding process used in wind tower and predicts optimal welding process to improve the stability of welded structures. Three dimensional elasto-plastic analyses are employed to evaluate thermo-mechanical behavior of residual stress and deformation during Tandem welding for different distance between two touches. To confirm the thermal distribution, Goldak's ellipse heat source model and the real size wind tower pipe model are utilized. Four different analyses are being performed, where in each case the distance between two electrode torches is being changed and residual stress and welding deformation are predicted. Depending on base material state, each case is divided into: Liquid (100mm), Austenite+Liquid (200mm), Austenite+Cementite (400mm), Pearlite+Cementite (800mm).

Reliability of articulated tower joint against random base shear

  • Islam, Nazrul;Ahmad, Suhail
    • Structural Engineering and Mechanics
    • /
    • v.27 no.1
    • /
    • pp.33-48
    • /
    • 2007
  • An Articulated tower is one of the compliant offshore structures connected to the sea-bed through a universal joint which is the most vulnerable location of the tower that sustains the randomly fluctuating shear stresses. The time history response of the bottom hinge shear is obtained and presented in the spectral form. The fatigue and fracture reliability assessment of the tower joint against randomly varying shear stresses have been carried out. Non-linear limit state functions are derived in terms of important random variables using S-N curve and fracture mechanics approaches. Advanced First Order Reliability Method is used for reliability assessment. Sensitivity analysis shows the influence of various variables on the hinge safety. Fatigue life estimation has been made using probabilistic approach.

Study on the reform case of safe distance between overhead transmission conductor of front steel pole in substation (변전소 인입 강관주 선간거리 개선사례 분석)

  • Lee, Jai-Wook;Hwang, Kwang-Su;KESCO, Jae-Kwam;Choi, Jong-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.369-373
    • /
    • 2008
  • This case analyze the point of trouble and reform processing construction on input design to resolve the problem for setting tower in front of narrow base at the 154kV OO Transmission Line substaion. Hereafter the input design are presented for the basic reference data which the case a point of trouble and reform contents, input design of special shape tower and the foundation on substation input design cannot be setted by standard type of tower because of narrow base and cannot keep clerance overhead transmission conductor input to the substion.

  • PDF

Nonlinear Dynamic Behaviors of Offshore Guyed Towers (해양구조물 Guyed Tower의 비선형 동적거동)

  • Park, Woo-Sun;Pyen, Chong-Kun;Park, Young-Suk
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.3
    • /
    • pp.126-136
    • /
    • 1991
  • This study is concerned with the nonlinear dynamic behaviors of guyed towers for wave loadings. In order to analyze the nonlinear responses of guyed towers efficiently, the main tower is modeled as an equivalent stick, the guyline system is idealized as a spring with nonlinear stiffness in the horizontal direction. and the pile foundation system is represented as a linear spring in the rotational direction. The wave forces on the main tower are evaluated by using Morison's equation. In order to consider adequately the nonlinearities of the guying system and drag forces due to fluid viscosity. the analyses are performed in the time domain. The mode superposition method is adopted for solving the nonlinear equation of motion efficiently. which is based on the Newmark integration scheme. Numerical analyses are carried out to investigate the sensitivity of two major design parameters for guyed towers. i.e., the clump weight conditions and the base renditions of the tower.

  • PDF

Field measurements of wind-induced transmission tower foundation loads

  • Savory, E.;Parke, G.A.R.;Disney, P.;Toy, N.;Zeinoddini, M.
    • Wind and Structures
    • /
    • v.1 no.2
    • /
    • pp.183-199
    • /
    • 1998
  • This paper discusses some of the findings arising from long-term monitoring of the wind effects on a transmission tower located on an exposed site in South-West England. Site wind speeds have been measured, together with the foundation loads at the base of each of the four legs. The results show good correlation between the wind speeds and leg strains (loads) for a given wind direction, as expected, for wind speeds in excess of 10 m/s. Comparisons between the measured strains and those determined from the UK Code of Practice for lattice towers (BS8100), for the same wind speed and direction, show that the Code over-estimates most of the measured foundation loads by a moderate amount of about 14% at the higher wind speeds. This tends to confirm the validity of the Code for assessing design foundation loads. A finite element analysis model has been used to examine the dynamic behaviour of the tower and conductor system. This shows that, in the absence of the conductor, the tower alone has similar natural frequencies of approximately 2.2 Hz in the both the first (transversal) and second (longitudinal) modes, whilst for the complete system and conductor oscillations dominate, giving similar frequencies of approximately 0.1 Hz for both the first and second modes.

Mean wind loads on T-shaped angle transmission towers

  • Guohui Shen;Kanghui Han;Baoheng Li;Jianfeng Yao
    • Wind and Structures
    • /
    • v.38 no.5
    • /
    • pp.367-379
    • /
    • 2024
  • Compared with traditional transmission towers, T-shaped angle towers have long cross-arms and are specially used for ultrahigh-voltage direct-current (UHVDC) transmission. Nevertheless, the wind loads of T-shaped towers have not received much attention in previous studies. Consequently, a series of wind tunnel tests on the T-shaped towers featuring cross-arms of varying lengths were conducted using the high-frequency force balance (HFFB) technique. The test results reveal that the T-shaped tower's drag coefficients nearly remain constant at different testing velocities, demonstrating that Reynolds number effects are negligible in the test range of 1.26 × 104-2.30 × 104. The maximum values of the longitudinal base shear and torsion of the T-shaped tower are reached at 15° and 25° of wind incidence, respectively. In the yaw angle, the crosswind coefficients of the tower body are quite small, whereas those of the cross-arms are significant, and as a result, the assumption in some load codes (such as ASCE 74-2020, IEC 60826-2017 and EN 50341-1:2012) that the resultant force direction is the same as the wind direction may be inappropriate for the cross-arm situation. The fitting formulas for the wind load-distribution factors of the tower body and cross-arms are developed, respectively, which would greatly facilitate the determination of the wind loads on T-shaped angle towers.

The study for design of the foundation insert of large wind turbine (대형풍력터빈 기초 인서트 설계에 관한 연구)

  • Han, Dong-Young;Choi, Won-Ho;Lee, Seung-Kuh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.391-394
    • /
    • 2007
  • The foundation insert is a tubular steel section which is embedded into the concrete of the foundation. The tower base section of the wind turbine is mounted on it. It has a top flange (L type) protruding far enough above the concrete to allow bolts to be inserted from underneath. The load is transmitted to the concrete at the base of the section through a T shaped flange. It has many holes for the reinforcements and the cables. The reinforcements of the concrete foundation run through the insert via a series of holes to bind the inner section to the outer section. Holes are provided for the power and communications cabling. The design follows normal European wind turbine practice, based on GL 2003 and Eurocode regulations.

  • PDF

Pitching Motion Analysis of Floating Spar-buoy Wind Turbine of 2MW Direct-drive PMSG (2 MW 영구자석 직접 구동형 부유식 스파 부이 풍력 발전기의 피칭 운동해석)

  • Shin, Pyungho;Kyong, Namho;Choi, Jungchul;Ko, Heesang
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • A series of coupled time domain simulations considering stochastic waves and wind based on five 1-h time-domain analyses are performed in normal operating conditions. Power performance and tower base Fore-Aft bending moment and pitching motion response of the floating spar-buoy wind turbine with 2 MW direct-drive PMSG have been analyzed by using HAWC2 that account for aero-hydro-servo-elastic time domain simulations. When the floating spar-buoy wind turbine is tilted in the wind direction, maximum of platform pitching motion is close to $4^{\circ}$. Statistical characteristics of tower base Fore-Aft bending moment of floating spar-buoy wind turbine are compared to that of land-based wind turbine. Maximum of tower base Fore-Aft bending moment of floating spar-buoy wind turbine and land-based wind is 94,448 kNm, 40,560 kNm respectively. This results is due to changes in blade pitch angle resulting from relative motion between wave and movement of the floating spar-buoy wind turbine.

Wind-induced responses and equivalent static wind loads of tower-blade coupled large wind turbine system

  • Ke, S.T.;Wang, T.G.;Ge, Y.J.;Tamura, Y.
    • Structural Engineering and Mechanics
    • /
    • v.52 no.3
    • /
    • pp.485-505
    • /
    • 2014
  • This study aimed to develop an approach to accurately predict the wind models and wind effects of large wind turbines. The wind-induced vibration characteristics of a 5 MW tower-blade coupled wind turbine system have been investigated in this paper. First, the blade-tower integration model was established, which included blades, nacelle, tower and the base of the wind turbine system. The harmonic superposition method and modified blade element momentum theory were then applied to simulate the fluctuating wind field for the rotor blades and tower. Finally, wind-induced responses and equivalent static wind loads (ESWL) of the system were studied based on the modified consistent coupling method, which took into account coupling effects of resonant modes, cross terms of resonant and background responses. Furthermore, useful suggestions were proposed to instruct the wind resistance design of large wind turbines. Based on obtained results, it is shown from the obtained results that wind-induced responses and ESWL were characterized with complicated modal responses, multi-mode coupling effects, and multiple equivalent objectives. Compared with the background component, the resonant component made more contribution to wind-induced responses and equivalent static wind loads at the middle-upper part of the tower and blades, and cross terms between background and resonant components affected the total fluctuation responses, while the background responses were similar with the resonant responses at the bottom of tower.

Reliability over time of wind turbines steel towers subjected to fatigue

  • Berny-Brandt, Emilio A.;Ruiz, Sonia E.
    • Wind and Structures
    • /
    • v.23 no.1
    • /
    • pp.75-90
    • /
    • 2016
  • A probabilistic approach that combines structural demand hazard analysis with cumulative damage assessment is presented and applied to a steel tower of a wind turbine. The study presents the step by step procedure to compare the reliability over time of the structure subjected to fatigue, assuming: a) a binomial Weibull annual wind speed, and b) a traditional Weibull probability distribution function (PDF). The probabilistic analysis involves the calculation of force time simulated histories, fatigue analysis at the steel tower base, wind hazard curves and structural fragility curves. Differences in the structural reliability over time depending on the wind speed PDF assumed are found, and recommendations about selecting a real PDF are given.