• Title/Summary/Keyword: Tower Structure

Search Result 432, Processing Time 0.028 seconds

Vibration-Based Damage Detection Method for Tower Structure (타워 구조물의 진동기반 결함탐지기법)

  • Lee, Jong-Won;Kim, Sang-Ryul;Kim, Bong-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.320-324
    • /
    • 2013
  • A crack identification method using an equivalent bending stiffness for cracked beam and committee of neural networks is presented. The equivalent bending stiffness is constructed based on an energy method for a straight thin-walled pipe, which has a through-the-thickness crack, subjected to bending. Several numerical analysis for a steel cantilever pipe using the equivalent bending stiffness are carried out to extract the natural frequencies and mode shapes of the cracked beam. The extracted modal properties are used in constructing a training patterns of a neural network. The input to the neural network consists of the modal properties and the output is composed of the crack location and size. Multiple neural networks are constructed and each individual network is trained independently with different initial synaptic weights. Then, the estimated crack locations and sizes from different neural networks are averaged. Experimental crack detection is carried out for 3 damage cases using the proposed method, and the identified crack locations and sizes agree reasonably well with the exact values.

  • PDF

Study on wind-induced vibration response of Jiayuguan wooden building

  • Teng Y. Xue;Hong B. Liu;Ting Zhou;Xin C. Chen;Xiang Zhang;Zhi P. Zou
    • Wind and Structures
    • /
    • v.37 no.3
    • /
    • pp.245-254
    • /
    • 2023
  • In this paper, the wind-induced response of Jiayuguan wooden building (world cultural heritage) in Northwest China was studied. ANSYS finite element software was used to establish four kinds of building models under different working conditions and carry out modal analysis. The simulation results were compared with the field dynamic test results, obtaining the model which reflects the real vibration characteristics of the wooden tower. Time history data of fluctuating wind speed was obtained by MATLAB programming. Time domain method and ANSYS were used to analyze the wind-induced vibration response time history of Jiayuguan wooden building, obtaining the displacement time history curve of the structure. It was suggested that the wind-induced vibration coefficient of Jiayuguan wooden building is 1.76. Through analysis of the performance of the building under equivalent static wind load, the maximum displacement occurs in the three-story wall, gold column and the whole roof area, and the maximum displacement of the building is 5.39 cm. The ratio of the maximum stress value to the allowable value of wood tensile strength is 45 %. The research results can provide reference for the wind resistant design and protection of ancient buildings with similar structure to Jiayuguan wooden tower.

Optimal design of a wind turbine supporting system accounting for soil-structure interaction

  • Ali I. Karakas;Ayse T. Daloglua
    • Structural Engineering and Mechanics
    • /
    • v.88 no.3
    • /
    • pp.273-285
    • /
    • 2023
  • This study examines how the interaction between soil and a wind turbine's supporting system affects the optimal design. The supporting system resting on an elastic soil foundation consists of a steel conical tower and a concrete circular raft foundation, and it is subjected to wind loads. The material cost of the supporting system is aimed to be minimized employing various metaheuristic optimization algorithms including teaching-learning based optimization (TLBO). To include the influence of the soil in the optimization process, modified Vlasov and Gazetas elastic soil models are integrated into the optimization algorithms using the application programing interface (API) feature of the structural analysis program providing two-way data flow. As far as the optimal designs are considered, the best minimum cost design is achieved for the TLBO algorithm, and the modified Vlasov model makes the design economical compared with the simple Gazetas and infinitely rigid soil models. Especially, the optimum design dimensions of the raft foundation extremely reduce when the Vlasov realistic soil reactions are included in the optimum analysis. Additionally, as the designated design wind speed is decreased, the beneficial impact of soil interaction on the optimum material cost diminishes.

Study of Welding Toughness Characteristics on the Root-pass Welding Process of High Tensile Steel at Tower Production for Offshore Wind Power Generation (해상풍력 발전용 타워 제작시 고장력강재의 초층용접에 관한 용접특성 연구)

  • Jung, Sung-Myoung;Kim, Ill-Soo;Kim, Ji-Sun;Na, Hyun-Ho;Lee, Ji-Hye
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.349-353
    • /
    • 2012
  • As the world wind energy market grows rapidly, the productions of wind power generation equipment have recently increased, but manufacturers are not able meet this requirement. Particularly offshore wind energy industry is one of the most popular renewable energy sectors. To generalize welding processes, the welding automation is considered for steel structure manufacturing in offshore wind energy to get high quality and productivity. Welding technology in construction of the wind towers is depended on progress productivity. In addition, the life of wind tower structures should be considered by taking account of the natural weathering and the load it endures. The root passes are typically deposited using Gas Tungsten Arc Welding(GTAW) with a specialized backing gas shield. Not only the validation consists of welders experienced in determining the welding productivity of the baseline welding procedure, but also the standard testing required by the ASME section IX and API1104 codes, toughness testing was performed on the completed field welds. This paper presents the welding characteristics of the root-pass welding of high tensile steel in manufacturing of offshore wind tower. Based on the result from welding experiments, optimal welding conditions were selected after analyzing correlation between welding parameters(peak current, background current and wire feed rate) and back-bead geometry such as back-bead width(mm) and back-bead height performing root-pass welding experiment under various conditions. Furthermore, a response surface approach has been applied to provide an algorithm to predict an optimal welding quality.

A Study on the Change of Exclusive Space for Balcony Expansion in an Apartment - Focused on an Apartment House below 85m2 of Exclusive Area- (아파트 발코니 확장에 따른 전용공간의 변화에 관한 연구 - 전용면적 85m2형 공동주택을 대상으로 -)

  • Bae, Dong-Sig
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.11-18
    • /
    • 2018
  • The purpose of this study is to analyze the structure and use change of the private space according to the balcony expansion and use it as the data of plan design. According to Bay, front length/width ratio and the change of balcony space before and after expansion of space organization of house units were analyzed. Common characteristics of Flat type and Tower type are an increase of the frontage length of house units in an apartment, an increase of the number of front bay, and an increase of integrated LDK focusing on living room. A difference is that Flat type shows high frontage ratio, Bay figure, and spatial arrangement favorable to front openness and lighting. Flat type shows higher area distribution than Tower type in LDK area distribution located in at the plane center. Spatial expandability and visual openness of Flat type are more beneficial than those of Tower type in the planning, and a balcony extension of house units has developed to direction to open more. Tower type creates various block images through a combination of house units focusing on the core. Uses after balcony expansion are area expansion of a balcony-neighboring room, storage space, expansion and function improvement of the variable range, and specialized space different from a neighboring room. In addition, there is no escapable space except for a shelter, so unit plan should be prepared to prevent using it other space of a shelter and to solve moving line of two-way horizontal refuge and vertical refuge.

Analytical Study of Static and Dynamic Responses of Multi-story Brick Pagoda of Silleuksa Temple (신륵사 다층전탑의 구조해석에 대한 연구)

  • Lee, Ga-Yoon;Lee, Sung-Min;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.33-40
    • /
    • 2022
  • Recently, cultural heritages in South Korea gain many interests of restoration and preservation from the government since many of that have been severely damaged during earthquakes. Many previous studies in both terms of experimental and analytical approaches have been done to examine structural behavior and decide appropriate methods of preservation. Being motivated by such researches, this research aims to investigate a religious stone pagoda dated back to the Goryeo Dynasty in Korea. The structure consists of a granite stone foundation and baked bricks, which resembles the shape of traditional pagodas. In order to examine the structural behavior of the pagoda, an analytical model is implemented using ANSYS, a comprehensive engineering simulation platform. For the time history analysis of the pagoda, several earthquake excitations are chosen and input to simulation modeling. Seismic response of the tower such as time domain, natural frequency, modal shapes and peak acceleration measured at each layer are presented and discussed. In addition, the amplification ratio of the tower is calculated from the accelerations of each layer to determine tower stability in accordance with Korean seismic design guide. The determination and evaluation of status and response of the brick tower by simulation analysis play an important role in the preservation of history as well as valuable architectural heritages in South Korea.

Proposal of a prospective public convenience through vertical division of space;TOILET TOWER (공간의 수직분할을 통한 미래형 공중화장실 제안;타워식 화장실)

  • Son, Bo-Ra
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.212-215
    • /
    • 2006
  • The Beautiful rest room is simple how to think. We need to understand that excretion is important as much as eating. When we didn't have foods, eating was important in itself no matter what our lives environments. But now we want to eat in more dignified and more cultural place. Most of restaurants spend money on adjusting place for the consumes' desire. It is same way about rest room, it is time to change our rest room to place of rest and speculation over the place which we fix our natural urge. We can fix our natural urge, take a rest, and get creative ideas in more convenient, more healthy and more comfortable. It is time for us to change out thought about rest room; it is not dirty and stink place, but civilized living place like developed country. Also, we need new concept to take a triangular position about rest room is one of structure over just decorations. This research suggest new public rest room without precedent based on instance analysis about rest room inside and outside the country.

  • PDF

Observed tropical cyclone wind flow characteristics

  • Schroeder, John L.;Edwards, Becca P.;Giammanco, Ian M.
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.349-381
    • /
    • 2009
  • Since 1998, several institutions have deployed mobile instrumented towers to collect research-grade meteorological data from landfalling tropical cyclones. This study examines the wind flow characteristics from seven landfalling tropical cyclones using data collected from eight individual mobile tower deployments which occurred from 1998-2005. Gust factor, turbulence intensity, and integral scale statistics are inspected relative to changing surface roughness, mean wind speed and storm-relative position. Radar data, acquired from the National Weather Service (NWS) Weather Surveillance Radar - 1988 Doppler (WSR-88D) network, are examined to explore potential relationships with respect to radar reflectivity and precipitation structure (convective versus stratiform). The results indicate tropical cyclone wind flow characteristics are strongly influenced by the surrounding surface roughness (i.e., exposure) at each observation site, but some secondary storm dependencies are also documented.

Surface Profile Measuring System for Axial Fan of Cooling Towers (냉각탑용 축류팬 형상 정밀도 측정 시스템)

  • Kang Jae-Gwan;Lee Kwang-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.151-158
    • /
    • 2005
  • An important component of a cooling tower is an axial fan, and there happens distortion in its shape which brings significant loss of efficiency. In this paper, a surface profile measuring system for large size axial fan of cooling towers is developed. A laser sensor is used as a measuring device and aluminum profiles and stepping motors are engaged into the system as frame structure and driving devices respectively. The measuring data are compared to the design data to compute the distortion of the axial fans. Two types of errors, axial and twist errors, are used to represent the precision of axial fan distortion. Genetic algorithm is used to solve the optimization problem during computing the precision. Results are displayed three dimensionally in a solid-modeler as well as 2-D drawings to help users find it with ease.

Monitoring of tall slender structures by GPS measurements

  • Chmielewski, Tadeusz;Breuer, Peter;Gorski, Piotr;Konopka, Eduard
    • Wind and Structures
    • /
    • v.12 no.5
    • /
    • pp.401-412
    • /
    • 2009
  • A method is applied for the estimation of structural damage of tall slender structures using natural frequency and displacements measurements by GPS. The relationship between the variation in the global stiffness matrix (or in the stiffness of each finite element) and the change in the natural frequencies of the structure is given. In engineering practice the number of frequencies which can be derived by GPS measurement of long-period structures will be equal to one, two or three first natural frequencies. This allows us in initial studies to detect damage with frequency changes based on forward methods in which the measured frequencies are compared with the predicted analytical data. This idea, of health monitoring from possible changes to natural frequencies, or from a statement of excessive displacements is applied to the Stuttgart TV Tower.