• Title/Summary/Keyword: Total hip replacement arthroplasty

Search Result 48, Processing Time 0.026 seconds

Clinical and Functional Outcomes of the Exeter V40 Short Stem in Primary and Revision Arthroplasty: Does the Indication Affect Outcomes in the Short Term?

  • Nemandra Amir Sandiford;Scott M. Bolam;Irrum Afzal;Sarkhell Radha
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.40-46
    • /
    • 2023
  • Purpose: A variety of short Exeter stems designed specifically for use in performance of total hip arthroplasty (THA) in primary and revision settings have recently been introduced. Some have been used 'off label' for hip reconstruction. The aim of this study is to report clinical and radiological results from the Exeter V40 125 mm stem in performance of primary THA and revision THA. Materials and Methods: This study had a retrospective design. Insertion of 58 (24 primary, 34 revision) Exeter V40 125 mm stems was performed between 2015 and 2017. The minimum follow-up period was two years. Assessment of the Oxford hip score (OHS), EuroQol-5 Dimension (EQ-5D), and radiological follow-up was performed at one and two years. Results: In the primary group, the preoperative, mean OHS was 13.29. The mean OHS was 32.86 and 23.39 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were at 0.14, 0.59, and 0.35, preoperatively, at one-year follow-up and two-year follow-up, respectively. In the revision group, the mean preoperative OHS was 19.41. The mean OHS was 30.55 and 26.05 at one-year and two-year post-surgery, respectively. The mean EQ-5D-3L scores were 0.33, 0.61, and 0.48 preoperatively, at one-year follow-up and two-year follow-up, respectively. No progressive or new radiolucent lines were observed around any stem at the time of the final follow-up in all patients in both groups. Conclusion: Encouraging results regarding use of Exeter V40 125 mm stems have been reported up to two years following surgery in primary and revision THA settings.

Effect of a PNF Intervention Strategy with the ICF Tool Applied to a Patient with Bilateral Total Hip Replacement Walking a Crosswalk (양측 엉덩관절 전치환술 환자의 횡단보도 걷기 개선을 위해 ICF Tool을 적용한 PNF 중재전략: 사례보고 )

  • Jin-cheol Kim;Jae-heon Lim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.1
    • /
    • pp.95-105
    • /
    • 2024
  • PURPOSE: This study aimed to utilize the International Classification of Functioning, Disability, and Health (ICF) tool to identify a problem list and explore intervention effects using proprioceptive neuromuscular facilitation (PNF) for improving the crosswalk performance of patients who have undergone a bilateral hip arthroplasty. METHODS: The subject of this study was a 43-year-old male who had undergone a bilateral hip arthroplasty. To address the subject's functional status, a clinical decision-making process was carried out in the order of examination, evaluation, diagnosis, prognosis, intervention, and outcome. Patient information during the examination was collected using the ICF core set. The evaluation involved listing the items of each problem using the ICF assessment sheet and identifying the interaction between activity limitations and the impairment level. The diagnosis explicitly described the causal relationships derived from the evaluation using ICF terminology. The prognosis presented activity goals, body function, and structured goals in terms of the activity and participation levels that needed to be achieved for an individual's functional status. The intervention approached problems through the four components of the PNF philosophy, namely basic principles and procedures, techniques, and patterns, in an indirect-direct-task sequence. Results were compared before and after the intervention using the ICF evaluation display. RESULTS: The results of the study showed that the primary activity limitation, which was the walking time across the crosswalk, showed improvement, and the trunk's counter rotation and the weight-bearing capacity of both the lower limbs, which were impairment level indicators, were enhanced. CONCLUSION: This study suggests that PNF intervention strategies will serve as a positive approach for improving crosswalk walking in patients with bilateral hip arthroplasty.

Total Ankle Replacement Arthroplasty (족관절의 인공관절 치환술)

  • Sung, Il Hoon;Kim, Hyun Uk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Total ankle replacement has been performed for treatment of end stage arthritis of the ankle, hopefully being an alternative to ankle arthrodesis. However, due to its high failure rates, earlier versions of ankle replacements were not regarded as successful procedures. The latest design has shown increasingly positive results. Total joint replacement of the ankle itself is still regarded as a demanding procedure and much more challenging than that of the hip and knee in many aspects. Several studies, however, have pointed out that it is becoming the viable, accepted alternative for arthrodesis with advanced implants, appropriate patient selection, and proper training experience of procedures. Compared with arthrodesis, it shows equal or better outcomes in pain relief, range of motion, and patient's satisfaction. We are attempting to review its biomechanical characteristics, implant design, indications, complications, clinical outcomes, and survival rate.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

Atypical Vancouver B1 periprosthetic fracture of the proximal femur in the United Kingdom: a case report challenged by myeloma, osteoporosis, infection, and recurrent implant failures

  • Sayantan Saha;Azeem Ahmed;Rama Mohan
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.89-96
    • /
    • 2024
  • The indications for total hip replacement are increasing and not limited to osteoarthritis. Total hip replacement may also be done for trauma and pathological fractures in patients otherwise physiologically fit and active. This trend has led to an inevitable rise in complications such as periprosthetic femoral fracture. Periprosthetic femoral fracture can be challenging due to poor bone quality, osteoporosis, and stress fractures. We present a case of periprosthetic femoral fracture in a 71-year-old woman with some components of an atypical femoral fracture. The fracture was internally fixed but was subsequently complicated by infection, implant failure needing revision, and later stress fracture. She was on a bisphosphonate after her index total hip replacement surgery for an impending pathological left proximal femur fracture, and this may have caused the later stress fracture. Unfortunately, she then experienced implant breakage (nonunion), which was treated with a biplanar locking plate and bone grafting. The patient finally regained her premorbid mobility 13 months after the last surgery and progressed satisfactorily towards bony union.

The Prediction of Health care Outcome of Total Hip Replacement Arthroplasty Patients using Charlson Comorbidity Index (Charlson Comorbidity Index를 활용한 고관절치환술 환자의 건강결과 예측)

  • Choi, Won-Ho;Yoon, Seok-Jun;Ahn, Hyeong-Sik;Kyung, Min-Ho;Kim, Kyung-Hun;Kim, Kyeong-Uoon
    • Korea Journal of Hospital Management
    • /
    • v.14 no.1
    • /
    • pp.23-35
    • /
    • 2009
  • The objectives of the present study is to examine the validity of Charlson Comorbidity Index(CCI) based on medical record data; to utilize the index to determine outcome indexes such as mortality, length of stay and cost for the domestic patients whose have received total hip arthroplasty. Based on medical record date, 1-year Mortality was analyzed to be 0.664 of C statistic. The $R^2$ for the predictability for length of stay and the cost was about 0.0181, 0.1842. Fee of national health insurance and total cost including the cost not covered by insurance, also had statistically significance above 3 points of Charlson point score(p=0.0290, 0.0472; $p.{\le}0.05$). The 1-year mortality index, length of stay and cost of the total hip arthroplasty patients which was obtained utilizing CCI have a limitative prediction power and therefore should be carefully analyzed for use.

  • PDF

Change of the Cement Mantle Thickness According to the Movement of the Femoral Stem in THRA (인공고관절 치환술에서 대퇴주대 회전에 따른 시멘트막 두께 변화)

  • Park, Yong-Kuk;Kim, Jin-Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.140-148
    • /
    • 2007
  • THRA(Total Hip Replacement Arthroplasty) has been widely used for several decades as a viable treatment of otherwise-unsolved hip problems. In THRA surgery, cement mantle thickness is critical to long-term implant survival of femoral stem fixed with cement. Numerous studies reported thin or incomplete cement mantle causes osteolysis, loosening, and the failure of implant. To analyze the effect of femoral stem rotation on cement thickness, in this study, we select two most popular stems used in THRA. Using CAD models obtained from a 3D scanner, we measure the cement mantle thickness developed by the rotation of a femoral stem in the virtual space created by broaching. The study shows that as the femoral stem deviates from the target coordinates, the minimum thickness of cement decreases. Therefore, we recommend development of a new methodology for accurate insertion of a femoral stem along the broached space. Also, modification of the stem design robust to the unintentional movement of a femoral stem in the broached space, can alleviate the problem.

Effect of Adding Ankle-Joint-Pumping Exercise to Gluteal-Muscle-Strengthening Exercise on Thigh Swelling, Gait ability and Pain level in Patients With Total Hip Arthroplasty (볼기근 근력강화 운동과 병행한 발목관절 펌핑 운동이 엉덩관절 전치환술 환자의 허벅지 둘레, 보행능력, 통증 수준에 미치는 영향 )

  • Hyun-gook Lee;Suhn-yeop Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.2
    • /
    • pp.17-28
    • /
    • 2024
  • PURPOSE: This study was conducted to investigate the effect of gluteal muscle strengthening exercises (GMSE) with ankle joint pumping exercises (AJPE) on thigh swelling, gait ability, and pain level in patients who underwent total hip arthroplasty. METHODS: A total of 38 patients who had undergone total hip replacement surgery >1 week prior participated in this study. Participants were randomly assigned to a group that performed only GMSE (CG; n = 19) and a group that performed GMSE and AJPE (EG; n = 19). The CG group performed GMSE for 30 min, and the EG group performed GMSE for 30 min followed by AJPE for 15 min. Exercises were performed five times a week, for a total of 20 times over 4 weeks in both groups. Thigh swelling (thigh size), 10 m walking test (10MWT) and timed up and go test (TUG) results, pain level (visual analogue scale, VAS) scores, Short Form 36 health survey (SF-36), and hip outcome scale (HOS) scores were evaluated before and after the intervention. RESULTS: After 4 weeks of intervention, significant differences were observed in the thigh size, 10MWT, TUG, VAS, SF-36, HOS before and after intervention in both groups (p < . 05). However, only thigh size showed a significant interaction between group and measurement time (p < . 05). CONCLUSION: GMSE combined with AJPE might be effective in improving the gait ability and pain level in patients with total hip arthroplasty, and GMSE may be more effective in improving thigh swelling and gait ability than GMSE without AJPE.

Health Care Providers' Perceptions of Physical Function in Older Adults with Arthroplasty from Hip Fracture (고관절 골절로 인공고관절 수술을 받은 노인의 신체적 기능에 대한 의료인의 인식 분석)

  • Ko, Young Ji;Lee, JuHee
    • Journal of muscle and joint health
    • /
    • v.22 no.2
    • /
    • pp.67-77
    • /
    • 2015
  • Purpose: This study was a qualitative research using focus group interviews to collect data on the health care providers' perceptions of physical function in older adults with arthroplasty from hip fracture. Methods: A total of 12 subjects participated in this study. In order to conduct focus group interviews, structured manuscript, field notes, visual recording, and debriefing notes were referred and thematic analysis was used in analysis phase. Results: The six themes were raised: 'burdensome client', 'health care providers' perception of functional decline in older adults after surgery', 'health care providers' perception of caregiver', 'medical environment perceived as affecting physical function', 'crucial components perceived as encouraging functional restoration', and 'difficulty of pain management' with 18 subthemes. Conclusion: Healthcare providers perceived functional decline of elderly after arthroplasty and identified points facilitating or disturbing physical function Moreover, various perspectives on pain management related to physical function were represented.