• Title/Summary/Keyword: Total flow rate

Search Result 1,255, Processing Time 0.03 seconds

Decomposition Characteristics of Tetrafluoromethane Using a Waterjet Plasma Scrubber (워터젯 플라즈마 스크러버 사불화탄소 분해 특성)

  • Lim, Mun Sup;Chun, Young Nam
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.63-71
    • /
    • 2017
  • It is recognized that tetrafluoromethane ($CF_4$) has a great influence on global warming. The $CF_4$ is known to have a large impact on climate change due to its large global warming index. In this study, a waterjet plasma scrubber (WPS) was designed and manufactured for the $CF_4$ decomposition. The WPS is a novel technology which is combined a gliding arc plasma and water injection at the center of the plasma discharge. This can give an innovative way for $CF_4$ decomposition by achieving larger plasma columnand generating OH radicals. A performance analysis was achieved for the design factors such as waterjet flow rate, total gas flow rate, consumption electric power, and electrode gap. The highest $CF_4$ decomposition and energy efficiencies were 64.8% and 6.43 g/kWh, respectively; Optimal operating conditions were 20 mL/min of waterjet flow rate, 200 L/min total gas flow rate, 5.3 kW consumption electric power, and 4.4 mm electrode gap. As for the 2 stage reactor of the WPS, the $CF_4$ decomposition efficiency improved as the 85.3% while the energy efficiency decreased as the 5.57 g/kWh.

Effects of Different Concentrate and Roughage Ratios on Ruminal Balance of Long Chain Fatty Acids in Sheep

  • Sasaki, H.;Horiguchi, K.;Takahashi, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.7
    • /
    • pp.960-965
    • /
    • 2001
  • The effects of different feeding ratios of concentrate (C) and roughage (R) on balance of long chain fatty acids and microbial fatty acids in the rumen of sheep were investigated. The diets were divided into 8:2 (concentrate feeding), 4:6 (middle mixture) and 0:10 (roughage feeding) ratios (C:R). Duodenal digesta was collected through 24 hours after feeding. Biohydrogenation rate, total duodenal flow of fatty acids and microbial fatty acids were measured. Total duodenal flow of fatty acids was significantly (p<0.05) increased with increasing concentrate. Total duodenal flow of fatty acid was greater than intake of fatty acid in all diets. In comparison with intake of each fatty acid, duodenal flow of stearic acid ($C_{18:0}$) remarkably increased in all diets. Biohydrogenation rate for total C18 unsaturated fatty acids in the rumen tended to increase (p<0.10) when sheep were fed the middle mixture. In particular, biohydrogenation rate of linoleic acid ($C_{18:2}$) and linolenic acid ($C_{18:3}$) with the middle mixture were highest (p<0.05) compared with other diets. Duodenal flow of protozoal fatty acids was significantly (p<0.05) increased with the increased supply of concentrate. That of bacterial fatty acids was significantly (p<0.05) increased with both concentrate diets compared with the roughage feeding diet. $C_{18:0}$ occupied the greater part of both protozoal and bacterial fatty acids in all treatments. Results indicated that biohydrogenation of free unsaturated fatty acids was actively carried out when the middle mixture diet was supplied, and that microbial uptake and synthesis of fatty acids were accelerated by adding the supply of concentrate.

Performance of Heat Recovery System using Evaporative Cooling (증발냉각을 이용한 배기열 회수장치의 성능에 관한 연구)

  • Yoo, Seong Yeon;Kim, Tae Ho;Kim, Myung Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Evaporative cooling is a very effective way for exhaust heat recovery that uses both latent heat and sensible heat. This study investigated the performance of a heat recovery system using evaporative cooling. The experimental apparatus comprised a plastic heat exchanger, a water spray nozzle, an air blowing fan, a water circulation pump, and measuring sensors for the temperature, humidity, and flow rate. The effectiveness of the sensible heat recovery without evaporation was measured and compared with that of the total heat recovery with evaporation. The effectiveness of the sensible and total heat recoveries decreased as the air flow rate increased, and a much higher effectiveness was obtained with the counterflow arrangement in both cases. For total heat recovery, the effectiveness increased with the water flow rate, and the parallel flow arrangement was found to be more sensitive to the water flow rate than the counterflow arrangement.

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF

Experimental Study of the Superheat and Control of the Refrigerant Flow-Rate in the Evaporator of a Multi-type Air-Conditioning System (멀티형 공조시스템의 증발기 과열도에 관한 실험적 연구 및 냉매유량 제어)

  • 김태섭;홍금식;손현철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.221-221
    • /
    • 2000
  • The heat exchange part in a modern multi-type air-conditioning system employs multiple-pass heat exchangers. The heat-transfer performance of an each pass in such an exchanger depends strongly on the length of the two-phase region and the mass flow of the refrigerant. The total length and diameters of the pipes, the exit conditions, and the arrangement of each pass as well as the geometrical shape of the distributor at the branching sections are considered to be major factors affecting the heat-transfer performance. The refrigerant commonly used in these systems is HCFC-22. The two objectives of this paper are to investigate the characteristics of the refrigerant flow rate and the superheat in the evaporator of a multi-type air-conditioning system for a single or simultaneous operating conditions and to control the superheat and the refrigerant flow rate of the evaporator.

  • PDF

Influence of Dopamine on Intrarenal Blood Flow in Dog (개의 신내 혈류에 미치는 Dopamine의 영향)

  • 고석태;강호연
    • YAKHAK HOEJI
    • /
    • v.28 no.3
    • /
    • pp.149-160
    • /
    • 1984
  • In order to certify the diuretic mechanism of dopamine, this study was performed in dog. The following results were obtained. Dopamine, when given intravenously, produced diuresis, and increased glomerular filtration rate (GFR), renal plasma flow (RPF), and amount of sodium excreted in urine. When infused directly into a renal artery, dopamine elicited a marked diuresis confined only to the infused side, with concomitant rises in osmolar clearance and sodium excretion as well as a slight increase in free water clearance. Simultaneously total renal plasma flow and medullary plasma flow increased markedly with a increase of glomerular filtration rate and renal plasma flow. Medullary concentration gradient of sodium also markedly lowered in the infused kidney. These changes were not observed during mannitol diuresis and renal action of dopamine were not apparent in dog pretreated with haloperidol. From the above experimental results, it is thought that dopamine, when given into a vien or infused directly into a renal artery, induces diuresis, and the mechanism of its action is due to dual actions which are hemodynamic effect along with glomerular filtraction rate, and the increased response in the medullary blood flow.

  • PDF

Study on the Heat Transfer Characteristics of Immerged and Falling Flows on Helical Tubes (헬리컬관외 침전 및 적하 열전달 특성에 관한 연구)

  • 황승기;윤상국;김동혁;이승갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.225-232
    • /
    • 2001
  • An experimental study is carried out to investigate the characteristics of heat transfer of outside helical tubes. The main heat exchanger consists of twelve curved columns with each 300mm diameter and the total length of 1.2m copper tube having an outer diameter of 19.05mm with 1.5mm thickness. Water flows down the outside of helical tube, where flow patterns are the vertical film falling flow, immerged flow, and mixed-flow which is the combination of film falling flow and immerged flow. Refrigerant 11 flow the inside of the tube countercurrently. The experimental range of inside flow rate is 1.7~3.2$\ell$/min and outside flow rate is 21-33$\ell$/min. The results are presented as Nusselt number with corresponding Reynolds number for variety of outside and inside flow rates. The heat transfer rates of the mixed flow are 8 to 56% higher than those of film falling flow or immerged flow only. Interpretation of the results is given on the basis of physical reasoning and the correlation equations.

  • PDF

A Study on Return Flow Ratio of Irrigation for a Paddy Field in Pumping Station by Water Balance Method (물수지분석 기법에 의한 양수장 몽리구역내 농업용수 회귀율 연구)

  • Choo, Tai-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.3
    • /
    • pp.249-255
    • /
    • 2004
  • To investigate the return flow ratio of irrigation water, lots of observations were made during the irrigation periods in 2003 crop year. This Area is a portion of Dae-Am pumping station basin which is located in Changryung-gun, Gyeongnam province. A water balance analysis was performed for a paddy field in Dae-Am pumping station in the Nakdong river basin, which is constructed for irrigation water supply. Daily rainfall data in the this area were collected and irrigation water flow rate, drainage water flow rate, infiltration and evaportranspiration were measured in field area. Irrigation water flow rate and drainage water flow rate were continuously observed by water level logger(GTDL-L10) during the growing season. The infiltration and evaportranspiration were measured by cylindrical 300mm depletion meter and cylindrical 200mm infiltrometer, respectively. Total irrigation and drainage flows were 654.7mm and 281.2mm in 2003. Total infiltration and evaportranspiration were 36.0mm and 160.0mm respectively. The mean of the daily evaportranspiration rate was 4.3mmm/d. The prompt return flow and retard return flow ratio were 43.0% and 5.5%, respectively. Total return flow ratio was 48.5%. Therefore, it can be concluded that the amount of irrigation water was much higher than design standard or reference in this study. It means that this was caused by the inadequate water management practice in the area where water was oversupplied on farmers' request rather than following sound water management principles, and design standard should be changed in the future.

Characteristics of Amorphous Silicon Gate Etching in Cl2/HBr/O2 High Density Plasma (Cl2/HBr/O2 고밀도 플라즈마에서 비정질 실리콘 게이트 식각공정 특성)

  • Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.79-83
    • /
    • 2009
  • In this study, the characteristics of amorphous silicon etching for the formation of gate electrodes have been evaluated at the variation of several process parameters. When total flow rates composed of $Cl_2/HBr/O_2$ gas mixtures increased, the etch rate of amorphous silicon layer increased, but critical dimension (CD) bias was not notably changed regardless of total flow rate. As the amount of HBr in the mixture gas became larger, amorphous silicon etch rate was reduced by the low reactivity of Br species. In the case of increasing oxygen flow rate, etch selectivity was increased due to the reduction of oxide etch rate, enhancing the stability of silicon gate etching process. However, gate electrodes became more sloped according to the increase of oxygen flow rate. Higher source power induced the increase of amorphous silicon etch rate and CD bias, and higher bias power had a tendency to increase the etch rate of amorphous silicon and oxide.

Analysis on the Drying Performance with the Flow Rate of Circulation Air in a Heat Pump Dryer (순환 공기 유량의 변화를 고려한 열펌프 건조기의 성능 해석)

  • Lee, Kong-Hoon;Kim, Oak-Joong;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The simulation of a heat pump dryer has been carried out to figure out the effect of air flow rate on the drying performance represented by MER, SMER, and so on. The simulation includes the analyses of one-stage heat pump cycle and simple drying process using the drying efficiency. The heat pump cycle with Refrigerant 134a has been considered. In the dryer, some of drying air from the drying chamber flows through the heat pump system, the rest of air bypasses the heat pump system. The two air flows joins before the drying chamber inlet. The performance parameters considered in the present study are MER, SMER, the temperature and humidity of drying air. Those parameters are compared for different total air flow rate or bypass air flow rate.