• 제목/요약/키워드: Total enthalpy

검색결과 71건 처리시간 0.057초

수평형 지중열교환기의 전열량 변화에 대한 실험적 연구 (A Experimental Study of Horizontal Geothermal Heat Exchanger System about Total Enthalpy Change)

  • 조성우;임병찬
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권4호
    • /
    • pp.1-7
    • /
    • 2014
  • This paper is performed to investigate of cooling effect and total enthalpy variation on EAHES(Earth-to-Air Heat Exchanger System) that is buried 3m depth and 60m length. Using EAHES, the reduction of the sensible heat is obviously but latent heat is showed increased trend. Although the outdoor average latent heat accounts for 53.2% of total enthalpy, latent heat of the exit air from EAHES was raised as 58%. For improving cooling effect of EAHES, it has to considered that how to remove the latent heat from EAHES.

0.4 MW 급 분절형 아크 히터를 이용한 초음속 플라즈마 풍동 특성 실험 (Experimental Analysis of a Supersonic Plasma Wind Tunnel Using a Segmented Arc Heater with the Power Level of 0.4 MW)

  • 김민호;이미연;김정수;최채홍;서준호;문세연;홍봉근
    • 한국항공우주학회지
    • /
    • 제41권9호
    • /
    • pp.700-707
    • /
    • 2013
  • 0.4 MW 급 분절형 아크 히터를 장착한 전북대학교 플라즈마 풍동의 초음속 유동 특성 실험을 수행하고 그 결과를 분석하였다. 실험에 사용된 분절형 아크 히터와 초음속 노즐은 16.3 g/s 의 질량유량에 대해 전극 당 150 A, 전체 300 A의 입력전류 조건으로 운전되었으며, 운전 결과 350 kW의 입력전력과 약 51.4 %의 열효율이 계측되었다. 이 때, 아크 히터 내 고엔탈피 플라즈마의 내부압력은 약 4 bar 로 측정되었으며, 이를 초음속 노즐을 통해 압력 45 mbar로 유지되는 진공쳄버 내로 팽창시킴으로써, 전체 엔탈피 11 MJ/kg을 가진 초음속 플라즈마 유동을 얻을 수 있었다. 전체 엔탈피 측정과 함께, 생성된 초음속 플라즈마 유동에 대해 원뿔각 $30^{\circ}$를 가진 원뿔 탐침을 삽입하여 경사 충격파와 이루는 각을 측정하였으며, 이 측정값들로부터, 발생된 초음속 플라즈마의 온도와 마하 수는 각각 약 2,950 K 및 약 3.7에 이를 것으로 예상되었다.

입.출구의 압력조건에 따른 보텍스 튜브의 에너지분리 특성에 관한 실험적 고찰 (Experimental Investigation for the Characteristics of Energy Separation of a Vortex Tube at Various Inlet and outlet Pressure Conditions)

  • 유갑종;김정수;최인수
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1149-1155
    • /
    • 2001
  • The experimental investigation on energy separation in a vortex tube has been carried out to sow the effect of inlet and outlet pressures with various working fluids(air,$O_2,\;and\; CO_2$). Those outlet pressure means cold outlet and hot outlet pressure which were set equally. The results showed that the total enthalpy variation became a maximum when the mass flow rate at the cold outlet was a half of the total mass flow rate in the vortex tube (y=0.5). The total enthalpy variation was quite affected by the pressure difference between the inlet and outlet of vortex tube when the ratio of the inlet pressure to the cold outlet pressure remained constant. Although specific enthalpy differences between the inlet and the outlet (both cold and hot outlet) did not noticeably vary with the pressure difference, the specific enthalpy difference between the inlet and cold outlet was dominantly affected by physical properties of working gases.

  • PDF

온도예조건화 나비어스톡스 방정식의 계산오차 문제 완화 방법 연구 (An Approach to Alleviate Cancellation Problem of Temperature Preconditioned Navier-Stokes Equations)

  • 이상현
    • 한국추진공학회지
    • /
    • 제14권1호
    • /
    • pp.11-19
    • /
    • 2010
  • 온도예조건화 나비어스톡스 방정식의 계산오차를 줄이기 위한 방법을 제시하였다. 이 방법은 또한 기존 예조건화 방법론에도 적용하였다. 제시된 방법의 타당성을 검토하기 위하여 다양한 마하수의 원형 실린더 주위의 단열 층류 점성 유동을 계산하였다. 엔탈피의 재정의를 통해 총엔탈피의 크기 정도를 줄임으로써 계산오차에 의한 온도예조건화의 수렴성 문제가 해결됨을 보였다.

운전조건에 따른 전열교환기의 성능특성 연구 (A Study on the Characteristics of Total Heat Exchanger under Various Conditions)

  • 배철호;임영헌;드래바굴노라;박지열;곽경민;주의성;김영생;김지용
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.891-897
    • /
    • 2005
  • The characteristics of energy Performance for total heat exchanger have been investigated under various conditions. In cooling operation the latent and enthalpy efficiency are affected by the difference of absolute humidity ratio between indoor and outdoor air. In addition to this the characteristics of absorbing material in the element affects the energy performance. Low dry bulb temperature of indoor air or high absolute humidity ratio in outdoor air give high latent and enthalpy efficiency even with the same temperature difference of dry bulb temperate between indoor and outdoor air.

다공형 유로를 적용한 전열교환기 소자의 성능향상에 관한 연구 (A Study on Improvement of Performance for Perforated Type Total HEX Element)

  • 곽경민;배철호;김지용;주의성
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.529-536
    • /
    • 2007
  • The perforated type element for a heat recovery ventilation system has been studied to improve the performance. Four holes of diameter of 6mm are punched out for each flow channel to break the boundary layer development and increase the turbulence. KS cooling and heating conditions and test procedures are applied for study. The efficiencies are compared to those of the typical element with smooth surface. For cooling operations, the temperature, latent and enthalpy efficiencies increase 2.5%, 18% and 8%, respectively. For heating operations, the temperature, latent and enthalpy efficiencies increase 3%, 5% and 3.2%, respectively.

외기냉방을 이용한 냉방부하 절감 연구 (Reduction of Cooling Load using Outdoor Air Cooling)

  • 김민용;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.51-58
    • /
    • 2011
  • Due to enhanced sealing and insulation of buildings, extensive use of glasses for building envelopes and increased use of heat generating office equipments, energy consumption of modem buildings for cooling is steadily increasing. With outdoor air cooling(ODAC) system, cooling load can be reduced by exchanging indoor air with the cold outdoor air during spring and fall seasons. If ODAC is operated based only on temperature, total cooling load may virtually increase if the outdoor humidity is high. To overcome this problem, ODAC should be controlled based on enthalpy. In this work energy saving characteristics of enthalpy controlled ODAC is studied using dynamic simulation. The result shows that cooling load can be reduced by 27% by adopting ODAC.

전북대 고온플라즈마 설비 구축현황 (The Status of the High Enthalpy Plasma Test Facility in Chonbuk National University)

  • 최성만;신의섭;서용석;서준호;홍봉근
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.417-420
    • /
    • 2010
  • 전북대학교 고온 플라즈마 응용연구센터 구축사업은 교육과학기술부의 기초연구사업으로 진행되고 있다. 사업기간은 2009년 7월1일부터 2014년 6월 30일까지 총 5년에 걸쳐 이루어 지고 있으며, 총 사업비는 393억원이다. 플라즈마 응용연구센터에서 구축하고자 하는 장비는 0.4MW급 Enhanced Huels 형 플라즈마 장비 1 set, 2.4MW 급 Enhanced Huels 형 플라즈마 장비 1 set, 그리고 RF 플라즈마 장비 60KW 및 200 KW 각각 1 Set 이다.

  • PDF