• Title/Summary/Keyword: Total design

Search Result 9,786, Processing Time 0.035 seconds

과다 설계변수를 고려한 차량 BIW의 소재배치 최적화 (Material Arrangement Optimization for Automotive BIW considering a Large Number of Design Variables)

  • 박도현;진성완;이갑성;최동훈
    • 한국자동차공학회논문집
    • /
    • 제21권3호
    • /
    • pp.15-23
    • /
    • 2013
  • Weight reduction of a automobile has been steadily tried in automotive industry to improve fuel efficiency, driving performance and the production profits. Since the weight of BIW takes up a large portion of the total weight of the automobile, reducing the weight of BIW greatly contributes to reducing the total weight of the vehicle. To reduce weight, vehicle manufacturers have tried to apply lightweight materials, such as aluminum and high-strength steel, to the components of BIW instead of conventional steel. In this research, material arrangement of an automotive BIW was optimized by formulating a design problem to minimize weight of the BIW while satisfying design requirements about bending and torsional stiffness and perform a metamodel-based design optimization strategy. As a result of the design optimization, weight of the BIW is reduced by 45.7% while satisfying all design requirements.

40kW급 터보제너레이터용 원심압축기의 공력설계 및 유동해석 (Aerodynamic Design and Analysis of a Centrifugal Compressor in a 40kW Class Turbogenerator Gas Turbine)

  • 오종식;윤의수;조수용;오군섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 강연회 및 연구개발 발표회 논문집
    • /
    • pp.128-135
    • /
    • 1998
  • Procedures and results of aerodynamic design of a centrifugal compressor are presented for development of a 40kW class turbogenerator gas turbine. Specification of higher level of total pressure ratio of 4 and total efficiency of $80\%$ requires advanced methods of design and analysis. In the meanline design/analysis, a method with conventional loss modeling and a method with the two-zone model are alternately used for more reliable prediction. In the impeller blade generation, a series of Bezier curve are combined to produce meridional contours and distributions of blade camber angle and blade thickness. Intermediate profiles of blades are repeatedly produced and changed to be finally fixed through quasi-three dimensional Euler flow analysis. Three dimensional compressible turbulent flow analysis is then performed for the impeller to be confirmed in the final step of design. Satisfactory results in the aerodynamic performance are obtained, which assures that there is no need of aerodynamic re-design.

  • PDF

Behavior of CFS built-up battened columns: Parametric study and design recommendations

  • Vijayanand, S;Anbarasu, M
    • Structural Engineering and Mechanics
    • /
    • 제74권3호
    • /
    • pp.381-394
    • /
    • 2020
  • The structural performance of cold-formed steel (CFS) built-up battened columns were numerically investigated in this paper. The built-up column sections were formed by connecting two-lipped channels back-to-back, with a regular spacing of battens plates, and have been investigated in the current study. Finite element models were validated with the test results reported by the authors in the companion paper. Using the validated models, the parametric study was extended, covering a wider range of overall slenderness to assess the accuracy of the current design rules in predicting the design strengths of the CFS built-up battened columns. The parameters viz., overall slenderness, different geometries, plate slenderness (b/t ratio) and yield stress were considered for this study. In total, a total of 228 finite element models were analyzed and the results obtained were compared with current design strength predicted by Effective Width Method of AISI Specifications (AISI S100:2016) and European specifications (EN1993-1-3:2006). The parametric study results indicated that the current design rules are limited in predicting the accuracy of the design strengths of CFS built-up battened columns. Therefore, a design equation was proposed for the AISI and EC3 specifications to predict the reliable design strength of the CFS Built-up battened columns and was also verified by the reliability analysis.

태양열주택 및 가정용 태양 온수시스템의 설계용 전산코드 (A Computer Code for an Optimum Design of Solar Space and Domestic Hot Water Heating System)

  • 임동주;전문헌;윤석범
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.37-42
    • /
    • 1984
  • A computer code for an optimum design of solar space and domestic hot water heating system has been developed. The f-chart method developed by S.A. Klein et al. has been incorporated in the present computer code. The main conclusions obtained from the present work may be summarized as follows: (1) In Seoul area, about 46% of the total heating load can be obtained from the solar collectors whose total surface area is about one-third of the total heating floor area. (2) In Pusan area, total area of solar collectors should be about half of the total heating floor area in order to obtain an equivalent solar fraction of Seoul. (3) In cheju area, on the other hand, only about 42% of the total heating floor area of solar collectors is needed to get the same solar fraction as in Seoul and Pusan. (4) In order to get the first 50% solar fraction, only about 10-14 collectors ($4'{\times}8'$ collectors) are required, whereas about 48 collectors are needed to obtain the solar fraction of 100%. That is, roughly 3.5-4.5 times greater number of collectors are required to increase the solar fraction from 50% to 100%. Therefore, it can be concluded that it is relatively inefficient and less economical to build a solar system whose solar fraction exceeds more than 50%.

  • PDF

Effects of Mat Pilates Exercise on Lower Extremity Function, Postural Balance, and Walking in the Older Women with Total Knee Arthroplasty

  • Wonjae Choi
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.517-525
    • /
    • 2022
  • Objective: The rehabilitation protocols for functional recovery have been emphasized after total knee arthroplasty, and Pilates is in the spotlight as a safe and easily modified exercise method. The purpose of this study was to investigate the effects of mat Pilates exercise on lower extremity function, postural balance, and walking in the individuals with total knee arthroplasty. Design: One group pretest-posttest design. Methods: Eighteen older women with unilateral total knee arthroplasty was recruited in the study. The subjects were evaluated on lower extremity function, postural balance, and walking before and after mat Pilates exercise. All subject performed one hour mat Pilates exercise, 3 times a week for 8 weeks. Mat Pilates exercises were focused on core stability and lower extremity strengthening and, more dynamic movements were added to increase the difficulty of movements every two weeks. The lower extremity function was measured using the Western Ontario and McMaster Osteoarthritis Index (WOMAC), knee joint position sense, and five times sit-to-stand test. Postural balance was assessed by single leg stance test, functional reach test, and timed up and go test. Walking was measured by OptoGait system to temporospatial parameter. Results: The lower extremity function, postural balance, and walking were significantly improved after mat Pilates exercise, except for five times sit-to-stand test (p<0.05). Conclusions: This study demonstrated that the mat Pilates exercise was a useful method to improve lower extremity function, postural balance, and walking in the older women with unilateral total knee arthroplasty.

Implant에 사용되는 CAD/CAM 전용 zirconia abutment의 표면적과 디자인에 따른 유지력 차이 (Differences in retention of the reduction direction depending on dimensions and design CAD/CAM zirconia abutment for implant)

  • 남택모;김한곤;김병식;임시덕
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.

Stage by stage design for primary, conventional activated sludge, SBR and MBBR units for residential wastewater treatment and reusing

  • Aziz, Shuokr Qarani;Omar, Imad Ali;Bashir, Mohammed J.K.;Mojiri, Amin
    • Advances in environmental research
    • /
    • 제9권4호
    • /
    • pp.233-249
    • /
    • 2020
  • To date, there is no central wastewater (WW) treatment plant in Erbil city, Kurdistan region, Iraq. Therefore, raw WW disposes to the environment and sometimes it used directly for irrigation in some areas of Erbil city. Disposal of the untreated WW to the natural environment and using for irrigation it causes problems for the people and the environment. The aims of the current work were to study the characteristics, design of primary and different secondary treatment units and reusing of produced WW. Raw WW samples from Ashty city-Erbil city were collected and analyzed for twenty three quality parameters such as Total Suspended Solids (TSS), total dissolved solids, total volatile and non-volatile solids, total acidity, total alkalinity, total hardness, five-day Biochemical Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), biodegradability ratio (BOD5/COD), turbidity, etc. Results revealed that some parameters such as BOD5 and TSS were exceeded the standards for disposal of WW. Design and calculations for primary and secondary treatment (biological treatment) processes were presented. Primary treatment units such as screening, grit chamber, and flow equalization tank were designed and detailed calculation were illustrated. While, Conventional Activated Sludge (CAS), Sequencing Batch Reactor (SBR) and Moving Bed Biofilm Reactors (MBBR) were applied for the biological treatment of WW. Results revealed that MBBR was the best and economic technique for the biological treatment of WW. Treated WW is suitable for reusing and there is no restriction on use for irrigation of green areas inside Ashty city campus.

사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(II) - 설계 사례 분석을 통한 매입 PHC말뚝의 설계 개선 방향 - (Study(II) on Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - Improvement Measures of Current Design Method by Analyzing Current Design Data for Prebored PHC Piles -)

  • 여규권;윤대희;윤도균;최용규
    • 한국지반공학회논문집
    • /
    • 제35권8호
    • /
    • pp.31-42
    • /
    • 2019
  • 최근에 시공된 건축현장의 73개 설계 자료를 분석하여 매입 PHC말뚝에 대한 설계 현황을 고찰하였다. 매입 PHC말뚝의 설계에서 사용하고 있는 극한지지력 산정공식에 따라 산정한 전체지지력에 대한 주면마찰력의 분담율(SRF)는 20~53%로 나타났다. 극한주면마찰력이 과소평가되는 지지력 산정공식에 대한 개선이 필요한 것으로 판단되었다. PHC말뚝의 재료 성능에 대한 평균 설계 효율은 약 70%이었으며 지반 지지력에 대한 평균 설계 효율은 약 80%이었다. 즉, 지반의 설계 효율은 PHC말뚝의 설계 효율보다 약간 높은 수준으로 나타나고 있었다. 이는 지반 지지력을 설계하중보다 동등한 수준 또는 그것보다 약간 높은 수준으로 계산하고 있는 설계 현황에 기인한 것으로 판단되었다. 지반의 허용지지력을 PHC말뚝의 허용연직압축하중보다 높은 수준으로 산정하여야 할 것으로 판단되었다. 매입 PHC말뚝의 지지력 산정공식에서는 극한주면마찰력이 극한선단지지력보다 상대적으로 2.2배 정도 낮은 수준으로 계산되었다. 매입 PHC말뚝의 설계에서 적용하고 있는 극한지지력 산정공식들은 모두 국외 지반을 대상으로 개발되었으며 국내 지반에 대한 적용성 검증 없이 도입되어 사용되어 오고 있었다. 매입 PHC말뚝의 설계에서 적용할 지지력 산정공식의 개선이 이루어져야 할 것으로 판단되었다.

주입선의 설치방법이 금속의 주조성에 미치는 영향에 관한 실험적 연구 (Sprue design and its effect on the castability of ceramonetal nonprecious alloys)

  • 김웅철
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.5-10
    • /
    • 1988
  • The purpose of this study was to evaluate the effect of spure designs and air vent on the relative castability of the nonprecious alloys, commonly used to make ceamometal restorations. Samples of total 30 were constructed and devided into 6 groups according to two variables, sprue design and air bent. The total number of completly cast squares was counted, verified, and recorded. The results obtained were as follows: 1. The runner bar or Rousseau designs yield better castability than reservoir design(P<0.1) 2. When the air vent was attached, only the castability of reservoir design was significantly different from runner bar or Rousseau designs.

  • PDF

태풍파를 기준으로한 전설계수심의 산정에 관한 연구 (A Study on the Calculation of Total Design Water Depth From Typhoon Waves)

  • 이종우
    • 한국항해학회지
    • /
    • 제13권3호
    • /
    • pp.45-65
    • /
    • 1989
  • Various typhoon data near Yongil Bay, Korea from 1961 to 1985 were collected with some critria and analyzed with the help of the computer. Introducing the pressure profile models and predicting the typhoon wind and wave fields, the 100-year design wave parameters were calculated. Additionally, the wave data at the southeast coast of Korea were statistically analyzed. The deep water wave climate of this bay indicated that Typhoon Brenda, 1985 had wave characteristics of 100-year return period, Typhoon model and storm surge model studies were made for this typhoon. These, including other design parameters, were introduced into the calculation of total design water depth.

  • PDF