• 제목/요약/키워드: Total decay rate

검색결과 80건 처리시간 0.028초

Synthesis and Evaluation of F-18 Labeled 2'-Deoxy-2'-fluoro-5-methyl-1-β-L-arabinofuranosyluracil (L-[18F]FMAU)

  • Jo, Nam-Hyun;Moon, Byung-Seok;Hong, Su-Hee;An, Gwang-Il;Choi, Tae-Hyun;Cheon, Gi-Jeong;Cho, Jung-Hyuck;Yoo, Kyung-Ho;Lee, Kyo-Chul;Oh, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2449-2453
    • /
    • 2007
  • L-[18F]FMAU ([18F]1b) was prepared from the precursor 2-O-[(trifluoromethyl)-sulfonyl]-1,3,5-tri-Obenzoyl- α-L-ribofuranose, by coupling the radioactive fluoro-sugar with the corresponding silylated thymine in 4 steps. The final products, including the α and β anomers, were purified using reverse phase HPLC with an appropriate solvent (5% CH3CN/H2O) at a flow rate of 3.0 mL/min. The total elapsed time of synthesis was about 180-200 min from EOB. The α/β anomeric ratio of the compounds was about 1:9, and the radiochemical purity of the product (β-form) was >98% with decay-corrected yields of 25-35%. All radioactive samples were confirmed using co-injection with pure non-radioactive analogues in every step. In the cellular uptake in vitro test of herpes simplex virus-thymidine kinase (HSV1-TK) gene expressed cells, the percent uptake of injected dose (%ID) of L- and D-FMAU was 37.28 and 65.86, respectively after 240 min incubation. However, the relative uptake (MCA-TK/MCA cellular uptake ratio) of L-FMAU was higher than that of D-FMAU (%ID of L-FMAU, 0.36 and D-FMAU, 0.93 after 240 min incubation in MCA cells). This means that L-FMAU will show better specific HSV1-TK gene expressed cell uptake for selective HSV1-TK gene imaging.

식품첨가물 Acetic Acid와 Propionic Acid 처리농도에 따른 콩나물의 생장과 형태 변화 (Effects of Food Additive Acetic Acids and Propionic Acids on Growth and Morphological Characters of Soybean Sprouts)

  • 홍동오;전승호;전병삼;이창우;김홍영;강진호
    • 한국자원식물학회지
    • /
    • 제19권5호
    • /
    • pp.606-611
    • /
    • 2006
  • 부패는 콩나물 재배에서 극복하여야 할 문제중의 하나이다. 본 연구는 콩나물 재배에서 부패완화용으로 식품첨가물의 이용 가능성을 검토하고자 은하콩, 풍산나물콩 및 오리알태를 공시품종으로 식품첨가물의 종류(acetic acid, propionic acid)와 농도(0, 0.1, 0.2%)가 콩나물의 생장과 형태, 병반 형성, 처리비용에 미치는 영향을 조사하기 위하여 실시하였던 바 그 결과를 요약하면 다음과 같다. 1. 상품화가 가능한 하배축 길이가 4cm 이상의 비율은 오리알태에서 가장 높고 은하콩에서 가장 낮았고, 식품첨가물 종류간에는 차이가 없었던 반면, 처리농도가 높을수록 증가하였다. 2. 하배축은 은하콩과 오리알태에 비하여 풍산나물콩에서 길었으며, 하배축 중간부분은 풍산나물콩과 오리알태에 비하여 은하콩에서 굵었다. 그러나 이들 하배축 길이와 직경은 식품첨가물 종류와 처리농도간에는 차이가 없었다. 3. 생산수율과 관련된 개체당 전체 생체중은 은하콩과 풍산나물콩에 비하여 오리알태에서 많았던 반면, 식품첨가물 종류와 처리농도간에는 차이가 없었다. 4. 자엽에 형성된 병반수는 식품첨가물 종류간에는 차이가 없었던 반면, 이들을 처리하지 않는 것보다는 처리할 경우 감소하였다. 5. 처리비용을 고려할 경우 acetic acid보다는 propionic acid를 이용하여 종자소독을 실시하는 것이 경제적인 것으로 분석되었다.

조류성장에 따른 하수 박테리아 군집 변화에 관한 분자생태학적 연구 (Molecular Ecological Characterization of Wastewater Bacterial Communities in Response to Algal Growth)

  • 이주연;이장호;박준홍
    • 대한환경공학회지
    • /
    • 제33권11호
    • /
    • pp.847-854
    • /
    • 2011
  • 주요 신재생에너지인 바이오에너지의 일환으로 조류를 이용한 바이오에너지 및 자원화 기술에 대한 관심이 높아지고 있다. 조류는 영양염류 제거 능력을 활용해서 하수와 같은 오폐수 내 난분해성오염물질과 영양염류 제거의 고도처리도 가능하다. 조류와 박테리아 간의 생태적인 상호작용이 조류를 활용한 하수처리 및 하수자원화에 중요한 역할을 함에도 불구하고, 실지 하수 조건에서 조류와 박테리아간의 생태학적인 상호작용에 관한 과학적인 정보가 부족하다. 본 연구에서는 하수에서 배양이 잘 되고, 지질함량이 높다고 알려진 국내 조류 종인 Ankistrodesmus gracilis SAG 278-2의 하수오염물질 제거 특성과 조류 주입에 따른 하수 박테리아 군집의 반응을 실지 하수 조건에서 연구하였다. 하수 박테리아의 수가 증가는 조류의 성장 속도를 감소시켰으나, 반면 조류의 성장은 박테리아의 생존 및 내성호흡 생분해 속도에는 영향을 주지 않았다. 조류가 주입된 하수에서 난분해성 유기물질 및 총질소의 제거 향상이 관찰되었다. 박테리아 16S rRNA 유전자 T-RFLP 분석에 따르면 조류의 주입은 시간에 따라 박테리아 군집에 영향을 주었다. 박테리아 16S rRNA 유전자 PCR 증폭, clone 및 염기서열 분석 결과, 하수 내 조류의 성장은 박테리아 군집 구성을 변화시키며, 조류와 함께 공동 성장 가능한 박테리아는 Sediminibacterium, Sphingobacterium, Mucilaginibacter 속에 속하는 개체로 판명되었다.

한우에서 전장의 유전체 정보를 활용한 연관불평형 및 유효집단크기 추정에 관한 연구 (Estimation of Linkage Disequilibrium and Effective Population Size using Whole Genome Single Nucleotide Polymorphisms in Hanwoo)

  • 조충일;이준호;이득환
    • 생명과학회지
    • /
    • 제22권3호
    • /
    • pp.366-372
    • /
    • 2012
  • 본 연구는 한우 유전체 전장에 존재하는 고밀도 단일염기다형을 DNA chip을 이용하여 각각의 유전자형을 구명하고, 동일염색체 내에 존재하는 각 표지인자쌍의 연관불평형을 성 염색체를 제외한 모든 상염색체에서 추정하여 물리적 거리별 연관불평형의 정도를 확인하고 이러한 결과를 이용하여 한우 집단의 유효집단 크기를 추정하기 위하여 실시하였다. 한우개량사업소에서 2005년부터 2008년까지 후대검정에 공시된 후보종모우 및 후대 검정우 288두에 대해 혈액을 채취하고 Bovine SNP 50 DNA Chip을 이용하여 유전자형을 분석하였으며, 총 51,582 표지인자 중 결측률이 10% 이상인 표지인자 1개 및 다형성이 없는 표지인자 10,730개에 대해 사전제거를 실시하고 남은 40,851개의 SNP표지인자를 본 분석에 활용하였다. 연구 결과, 성 염색체를 제외한 상 염색체의 총 SNP표지인자의 길이는 2,541.6 Mb였으며, 염색체별 평균 SNP표지인자간 거리는 0.55에서 0.74로 분포하였으며, EM알고리즘을 이용하여 염색체별 연관불평형을 추정해 보았을 때, 기존의 보고된 연구와 유사하게 표지인자간 거리가 짧을수록 높게 나타나는 지수형태의 그래프를 나타냈으며, SNP표지인자간 거리에 따른 $r^2$를 보면, 0 Mb에서 0.1 Mb일 때 0.136, 0.1-0.2 Mb에서 0.06로 나타났다. Luo (1998)의 연구결과를 한우에 적용시켰을 때, 전체분산의 5%이상 설명하는 양적형질좌위 발굴을 위해서 약 2,000두의 표현형 자료가 필요할 것으로 사료되었다. 또한 한우의 세대별 유효집단 크기에 대해 추정해 본 결과, 현재 한우의 유효집단크기는 84두로 추정되었고, 지금으로부터 약 50세대 이전의 유효집단 크기는 1,150두로 추정되었다. 가축에서 인공수정이 도입(1960년대)된 이 후 개량의 가속화로 인해 한우의 유효집단 크기가 급격히 감소한 것으로 사료되었다.

호박과실파리 발생생태 및 계절초기 성충우화시기 예찰 모형 (Population Phenology and an Early Season Adult Emergence model of Pumpkin Fruit Fly, Bactrocera depressa (Diptera: Tephritidae))

  • 강택준;전흥용;김형환;양창열;김동순
    • 한국농림기상학회지
    • /
    • 제10권4호
    • /
    • pp.158-166
    • /
    • 2008
  • 호박과실파리(Bactrocera depressus)는 파리목 과실 파리과에 속한 곤충으로 박과류 작물의 중요한 해충이다. 이 연구는 호박과실파리의 호박 피해관련 기초생태를 구명하고 성충우화시기 예찰모형을 개발하고자 수행하였다. 애호박 생산농가에서 호박과실파리 산란 흔적은 7월 중하순부터 발생되기 시작하여 8월 하순 최성기를 보였으며 9월 하순부터는 발견되지 않았으며, 이 기간이 호박과실파리 산란활동 시기로 판단되었다. 숙과호박 농가에서는 7월 하순 어린 과실에 산란 흔적이 발견되었고 8월 이후 유충에 의한 호박의 부패가 시작, 10월까지 피해과가 급격히 증가하였다. 호박과실파리 산란흔적은 호박 과실 당 평균 2.2개가 발견되었으며, 과실 당 $28.8{\sim}29.8$개의 산란수를 보였다. 우화트랩으로 조사한 호박과실파리 월동번데기의 우화시기는 초발일이 5월 중순에서 하순 사이로 나타났고, 최성기는 5월 하순 내지 6월 상순이었다. 호박과실파리 월동번데기의 우화까지 발육기간은 $15^{\circ}C$에서 59.0일, $20^{\circ}C$ 39.3일, $25^{\circ}C$ 25.8일, $30^{\circ}C$ 21.4일이었고 $35^{\circ}C$에서는 발육하지 못하였다. 온도와 월동번데기 발육기간 관계에 대한 선형모형 추정결과는 발육영점온도는 $6.8^{\circ}C$로 추정되었고 발육완료에 필요한 적산온도는 482.3 DD 이었다. 또한 월동번데기 발육률과 온도와 비선형적 관계는 Gaussian 모형으로 잘 설명되었다. 적산온도 모형으로 50% 성충우화일을 예측한 결과 실측치와 편차가 1일로 적중률이 높았다. 또한 발육모형과 발육완료시기 분포모형(Weibull 함수)을 이용한 발율률 적산모형의 예측치는 실측치의 우화양상과 유사하였다. 본 연구결과는 향후 호박과실파리의 관리전략 수립에 유용하게 이용될 수 있을 것으로 기대된다.

돌나물 수집계통의 수확후 저장온도에 따른 품질변이 (Variation of Fresh Shoot Quality by Storage Temperature after Harvesting in Local Strain of Sedum sarmentosum)

  • 김효진;배종향;이승엽
    • 생물환경조절학회지
    • /
    • 제16권3호
    • /
    • pp.240-246
    • /
    • 2007
  • 돌나물의 수확후 저장온도가 저장성에 미치는 영향을 분석하기 위하여 저장온도에 따른 생체중, 색상차, 엽록소 함량, 수분함량, 외관상 변화 등을 조사하였다. 생체중은 저장온도에 따라 8.7-25.3%의 감소를 보였으며, 저장온도가 높을수록 생체중 감소율도 높았다. 계통에 따른 생체중 감소는 포항지방종이 가장 컷으며, 완주 지방종의 변화가 비교적 적었다. 외관상 품질은 $20^{\circ}C$에서 4일경, $10^{\circ}C$에서 6일경, $5^{\circ}C$에서 8일경부터 하위 잎에 변색이 나타나기 시작하였으며, 시간이 지남에 따라 서서히 부패하기 시작하였다 SPAD 값으로 비교한 엽록소 함량은 $20^{\circ}C$$10^{\circ}C$에서는 4일과 6일 후부터 급격한 감소를 보였으나, $5^{\circ}C$에서는 변화가 적었다. 잎의 색도 변화에서 명도를 나타내는 L값과 녹색-적색을 나타내는 a값은 저장온도가 높을수록 저장일 수에 따라 유의하게 증가하였다. 저장 후 10일째에 변색이나 부패한 돌나물의 비율은 저장온도가 높을수록 증가하였으며, 이는 수확시의 수분함량과 유의한 상관 관계를 보였다(P=0.01). 계통간에는 완주 지방종이 비교적 저장성이 높았으며, 군산, 완도, 포항 순으로 부패율이 높았다. 따라서 돌나물을 스치로폼 접시에 랩포장 할 경우, $5^{\circ}C$에서는 수확 후 8일까지 상품성을 유지한 상태로 저장이 가능하였다.

토마토 'Tabor' 품종의 파렛트 단위 MAP 적용 연구 (Development of pallet-scale modified atmosphere packaging for 'Tabor' tomatoes)

  • 박종우;김진세;박석호;최동수;최승렬;김용훈;이수장;박천완;이정수
    • 한국식품저장유통학회지
    • /
    • 제23권5호
    • /
    • pp.614-622
    • /
    • 2016
  • 본 연구에서는 수출용 토마토의 파렛트 단위 MAP를 통한 저장 및 유통 가능성을 분석하고 미생물 생육 및 토마토의 품질에 미치는 영향을 분석하고자 하였다. Turning 단계에서 수확된 Tabor 토마토를 박스 포장한 후 제작된 MAP 파렛트에 적층하고 나일론 필름을 이용하여 포장하여 혼합기체를 주입하여 초기 기체조성(5% $O_2$, 1% $CO_2$)을 하였다. MAP 및 일반 파렛트를 $10^{\circ}C$에서 저장하며 감모율, 가용성 고형분 함량, 적정산도, 색변화, 경도 및 페놀화합물함량 변화를 조사하였다. 저장초기 7일 MAP에서는 감모율 및 경도변화가 각각 0.84% 및 0.84N로 관행 파렛트 대비 높게 나타났으나 토마토의 품질에 영향 끼치는 수준은 아닌 반면, 후숙에 따른 총 색변화는 MAP에서 4.72로 관행저장 5.99 대비 21.2% 낮게 나타나 뚜렷한 후숙 지연효과를 나타냈다. 가용성 고형분 함량 및 적정산도는 저장기간이 증가함에 따라 저장방법에 관계없이 감소하는 경향을 나타내었으나, 저장 21일차까지 MAP에서 가용성 고형분, 적정산도 감소율이 각각 1.7% 및 1.9% 지연되었다. 뿐만 아니라 페놀화합물의 경우 관행저장에서 12.4%가 감소한 반면 MAP에서는 3.9%가 증가하였다. 그밖에 저장에 따른 부패율은 MAP 파렛트에서 14일차에 10%, 21일차에 35%이상 낮게 나타났으며, 미생물 성장률에서 총호기성 세균 및 곰팡이의 성장률은 MAP 파렛트에서 관행저장 대비 각각 28.8% 및 38.8% 가량 낮게 나타나 곰팡이 억제를 통한 토마토의 상품성 유지에 뛰어난 효과를 보였다. 이러한 결과에 비추어볼 때 파렛트 MAP 패널 및 나일론 비닐을 이용한 수출용 토마토의 파렛트 단위 MAP는 실용 가능한 기술로서 토마토의 품질 유지 및 저장기간 연장에 효과적일 것으로 판단된다.

폐포대식세포에서 내독소 자극에 의한 Superoxide Dismutase 유전자발현의 조절 기전 (Superoxide Dismutase Gene Expression Induced by Lipopolysaccharide in Alveolar Macrophage of Rat)

  • 박계영;유철규;김영환;한성구;심영수;현인규
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권4호
    • /
    • pp.522-534
    • /
    • 1995
  • 연구배경: 내독소에 의한 급성 폐손상의 발병기전에서 산소기가 중요한 역할을 한다는 사실은 잘 알려져 있다. 세포내에는 이러한 산소기에 의한 세포의 손상을 방지하는 정상 방어기전으로 여러 항산화효소가 존재하는데, 이중 SOD는 세포대사과정이나 외부 자극에 의해 생성된 superoxide로부터 세포의 손상을 방지하는 역할을 한다. 세포내 SOD는 주로 이중체의 구조로 세포질에 존재하는 CuZnSOD와 사중체의 구조로 미토콘드리아에 존재하는 MnSOD의 두 종류가 알려져 있으나, 폐포대식세포에서의 SOD mRNA 발현 및 그 조절기전에 대해서는 확실히 규명되어 있지 않다. 본 연구의 목적은 백서의 폐포대식세포에서 내독소 자극에 의한 MnSOD와 CuZnSOD mRNA 발현양상을 관찰하고 내독소 자극시 니타나는 SOD mRNA 발현의 조절기전을 규명하는데 있다. 방법: 백서의 기관지폐포세척액에서 얻은 세포를 plastic plate에 부착시켜 폐포대식세포를 분리한 후 내독소를 자극하여 내독소 용량($0.01{\mu}g/ml{\sim}10{\mu}g/ml$)과 자극시간(0, 2, 4, 8, 24 hrs)에 따른 MnSOD와 CuZnSOD MnSOD 발현양상을 Northern blot analysis를 시행하여 관찰하였다. 다음 단계로 MsSOD와 CuZnSOD mRNA 발현의 조절기전을 밝히고자 폐포대식세포를 각각 AD($5{\mu}g/ml$) 또는 CHX($5{\mu}g/ml$)로 전처치한 후 내독소로 자극하여 MnSOD와 CuZnSOD mRNA의 발현양상을 관찰하였다. 한편 내독소 투여가 SOD mRNA의 안정성을 변화시키는지 여부를 평가하기 위해 폐포대식세포를 대조군과 투여군으로 나누어 SOD mRNA의 분해속도를 비교하였다. 총 세포내 RNA는 guanidinium thiocyanate/phenol/chloroform법을 이용하여 추출하였고, Northern blot analysis는 $^{32}P$로 표지된 백서의 MnSOD와 CuZnSOD cDNAs를 이용하여 시행하였다. 결과: 백서의 폐포대식세포에서 MnSOD mRNA의 발현은 내독소 투여량의 증가세 따라 증가되었고 내독소를 투여하고 8시간후에 정점을 이루었으나, CuZnSOD mRNA의 발현은 내독소의 용량 및 투여후 반응시간에 따라 변화하지 않았다. 내독소 투여후 MnSOD mRNA의 발현증가는 AD 또는 CHX 각각의 전처치에 의해 모두 억제되었다. MnSOD mRNA의 안정성은 내독소 투여에 의해 변화하지 않았다. 결론: 이상의 결과로 백서의 폐포대식세포는 내독소 자극에 반응하여 SOD를 생성하는 중요세포이고, 내독소에 의한 MnSOD mRNA의 발현은 전사단계에서 조정되며 mRNA의 안정성을 변화시키지 않고 새로운 단백의 합성이 필요한 것으로 사료된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF