• Title/Summary/Keyword: Total collection efficiency

Search Result 109, Processing Time 0.03 seconds

Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System (지역난방 적용 태양열시스템의 장기 열성능 분석)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

Can cities become self-reliant in energy? A technological scenario analysis for Kampala, Uganda

  • Munu, Nicholas;Banadda, Noble
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.219-225
    • /
    • 2016
  • Energy self-reliance is important for economic growth and development for any nation. An energy self-reliance technological analysis for Kampala the capital city of Uganda is presented. Three renewable energy sources: Municipal Solid Waste (MSW), solar and wind are assessed for the period of 2014 to 2030. Annual MSW generation will increase from $6.2{\times}10^5$ tons in 2014 to $8.5{\times}10^5$ and $1.14{\times}10^6$ tons by 2030 at 2% and 3.9% population growth respectively. MSW energy recovery yield varies from 136.7 GWh (2014, 65% collection) to 387.9 GWh (2030, 100% collection). MSW can at best contribute 2.1% and 1.6% to total Kampala energy demands for 2014 and 2030 respectively. Wind contribution is 5.6% and 2.3% in those respective years. To meet Kampala energy demands through solar, 26.6% of Kampala area and 2.4 times her size is required for panel installation in 2014 and 2030 respectively. This study concludes that improving renewable energy production may not necessarily translate into energy self-reliant Kampala City based on current and predicted conditions on a business as usual energy utilization situation. More studies should be done to integrate improvement in renewable energy production with improvement in efficiency in energy utilization.

A Study on the Efficiency and Productivity Change of Korean Non-Life Insurance Company After Financial Crisis (금융위기 이후 국내 손해보험회사의 효율성 및 생산성 변화 연구)

  • Park, Chun-Gwang;Kim, Byeong-Chul
    • The Korean Journal of Financial Management
    • /
    • v.23 no.2
    • /
    • pp.57-83
    • /
    • 2006
  • The purpose of this paper is to analyze the efficiency and productivity change and inefficiency cause of the korean non-life insurance companies of the before($1993{\sim}1996$) and after($1998{\sim}2004$) of IMF. we use DEA (Data Envelopment Analysis) model to measure company efficiency and MPI(Malmquist productivity indices) to measure company productivity change and Tobit regression to analyze inefficiency cause. we utilize ten non-life insurance companies in korea and the time-series data for eleven from 1993 to 2004 except 1997. The empirical results show the following findings. First, total cost efficiency shows that the after of IMF decrease of 3.7% over the before of IMF and MPI change indicates that the after of IMF increase 7.7% over the before IMF. Second, the results of Tobit regression to analysis the cause of inefficiency show that total cost efficiency is positively related invested assets, acquisition expenses ratio, collection expenses ratio and is negatively related solicitors ratio, personnel expenses ratio, land & buildings expenses ratio, loss ratio, net operating expenses ratio. Especially inefficiency of small-to-mid sized companies is main cause of total cost efficiency of non-life insurance companies in korea. Small-to-mid sized companies endeavored various aspects of business strategies.

  • PDF

A Study on the Relative Operational Efficiency of Foreign Port Transportation Industry (외항운송업의 상대적 운영효율성 분석)

  • Kang, Da-Yeon;Lee, Ki-Se
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2021
  • In Korea, which achieved economic growth due to export industries, the economic importance of the foreign port transportation industry is very great. The government took the initiative in fostering the foreign port transportation industry, and as a result, it developed into one of the top 10 foreign port transport countries in the world. However, due to the poor management of the small and medium-sized foreign port transport business and the trade dispute between countries, the foreign port transportation industry has faced a long-term invasion. Therefore, in order for these companies to recover again, they will, among other things, have to reorganize their operational inefficiency to carry out efficient production activities. In this study, we want to analyze the management efficiency of the top 10% companies in the unlisted domestic outbound shipping industry, present the project value of inefficient enterprises, and confirm the reference collection of companies that may be subject to benchmarking. For this purpose, a total of 10 foreign port transportation industry were analysed for efficiency and scale profitability (RTS) of the CCR and BCC models. The analysis showed that there were a total of six entities with BCC efficiency and five entities with CCR efficiency. In addition, there were a total of five entities with both BCC and CCR efficiency.

Evaluation of Amino Acid and Energy Utilization in Feedstuff for Swine and Poultry Diets

  • Kong, C.;Adeola, O.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.7
    • /
    • pp.917-925
    • /
    • 2014
  • An accurate feed formulation is essential for optimizing feed efficiency and minimizing feed cost for swine and poultry production. Because energy and amino acid (AA) account for the major cost of swine and poultry diets, a precise determination of the availability of energy and AA in feedstuffs is essential for accurate diet formulations. Therefore, the methodology for determining the availability of energy and AA should be carefully selected. The total collection and index methods are 2 major procedures for estimating the availability of energy and AA in feedstuffs for swine and poultry diets. The total collection method is based on the laborious production of quantitative records of feed intake and output, whereas the index method can avoid the laborious work, but greatly relies on accurate chemical analysis of index compound. The direct method, in which the test feedstuff in a diet is the sole source of the component of interest, is widely used to determine the digestibility of nutritional components in feedstuffs. In some cases, however, it may be necessary to formulate a basal diet and a test diet in which a portion of the basal diet is replaced by the feed ingredient to be tested because of poor palatability and low level of the interested component in the test ingredients. For the digestibility of AA, due to the confounding effect on AA composition of protein in feces by microorganisms in the hind gut, ileal digestibility rather than fecal digestibility has been preferred as the reliable method for estimating AA digestibility. Depending on the contribution of ileal endogenous AA losses in the ileal digestibility calculation, ileal digestibility estimates can be expressed as apparent, standardized, and true ileal digestibility, and are usually determined using the ileal cannulation method for pigs and the slaughter method for poultry. Among these digestibility estimates, the standardized ileal AA digestibility that corrects apparent ileal digestibility for basal endogenous AA losses, provides appropriate information for the formulation of swine and poultry diets. The total quantity of energy in feedstuffs can be partitioned into different components including gross energy (GE), digestible energy (DE), metabolizable energy (ME), and net energy based on the consideration of sequential energy losses during digestion and metabolism from GE in feeds. For swine, the total collection method is suggested for determining DE and ME in feedstuffs whereas for poultry the classical ME assay and the precision-fed method are applicable. Further investigation for the utilization of ME may be conducted by measuring either heat production or energy retention using indirect calorimetry or comparative slaughter method, respectively. This review provides information on the methodology used to determine accurate estimates of AA and energy availability for formulating swine and poultry diets.

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth (소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Sohn, Jong-Ryeul;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.

Development History and Direction of On-site Algae Collecting System with Flotation Technology (부상분리 기술을 이용한 현장형 조류수거시스템의 발전 과정 및 개발 방향)

  • Kim, Jong Ik;Han, Ihn Sup;Mei, Qi Wen;Cho, Chong Joo;Jung, Soon Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.194-200
    • /
    • 2017
  • On-site Algae Collecting System (OACS) is one of urgent countermeasures to clean the raw water when the algae blooms severely. Rapid reaction capability, high efficiency and large capacity are required when applying OACS to large water areas. The total performance of OACS are always determined by unit process named Flotation, Trapping and Collection. The working efficiency and daily treatment quantity of OACS can be increased when it runs automatically. As the rapid development of OACS technology, in the first place, equipment are miniaturized and simple. And in the second place, automation process from Trapping to Collection are advanced. So, They produce results higher working efficiency, smaller residual sludge on treated water, system's advanced environmental friendly features and the increased amount of sludge by Collection process to achieve large capacity. Now OACS has overcome the algae multiplication rate to ensured the amount of removal algae. In another aspect, it is high economically feasible because of reducing operation cost against the large capacity.

Precipitation Characteristics with the Relative Position of the Ionizer in a Two-stage Electrostatic Precipitator (이단식 전기 집진 장치에서 하전부의 상대 위치 변화에 따른 집진 특성)

  • Lim, Hun-Chan;Lee, Duck-Chool
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.2
    • /
    • pp.66-71
    • /
    • 1998
  • A compact ESP of two-stage type is widely used with positive corona discharge in working environment where the production of ozone is extreamly prohibited. Since there are few scientific reports on a compact ESP, we have investigated the fundamental characteristics of a two-stage ESP. A model two-stage ESP is made with simple structure in order to simplify theoretical analysis and the relative position of the ionizer and collector section can be changed. The experimental investigation revealed many interesting facts.: The electric field in the collector electrodes affects the corona discharge of the ionizer. The concentration of particles after collector remarkably varied in the region between the high voltage and grounded electrodes. The collection efficiency right behind the high voltage electrode is much greater than that behind the grounded one. The total collection efficiency, calculated by integrating the particle concentration in whole measuring region, is greater when the high voltage electrode of the collector is located behind the discharge electrode of ionizer. Thus, the relative position of the ionizer and collector electrodes affects the precipitation characteristics.

  • PDF

The study on the comparison of the operation performance of different type of solar collectors (여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구)

  • Kim, Huidong;Baek, Namchoon;Lee, Jinkook;Joo, Moonchang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF