• 제목/요약/키워드: Total collection efficiency

검색결과 109건 처리시간 0.028초

평판형 방전판을 갖는 2단식 전기집진기의 집진판 블록배열이 집진효율에 미치는 영향 (Effects of the Block Arrangement on the Collection Efficiency in the Two-Stage Electrostatic Precipitator with Charging Plate)

  • 박성호;박청연;김태권
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.641-652
    • /
    • 2000
  • The effect of block arrangement has been investigated on the particle deposition in the specified collecting cell of two-stage electrostatic precipitator by numerical analysis. Recirculation zone existed at the downstream of the block in the collecting cell, and the particles entering the recirculation zone were deposited on the collecting plate. Particle trajectory and deposition had considerably different phenomenon according to electrostatic and inertial effect, which depended on inlet mean velocity, electrostatic number, and particle diameter in the collecting cell. The total collection efficiency reached a minimum value through an interaction of electrostatic and inertial effect. In the computational domain, total collection efficiency for the case of two blocks in the computational domain was more than that of one block at the relative small electrostatic number. However as the block distance and inertial effect increased, the difference between the collection efficiency of two cases decreased. In the range of relatively small particle size total collection efficiency was always superior to particle collection efficiency that was predicted by Deutsch equation.

  • PDF

승용차용 Cabin Air Filter의 성능 (Performance of Automotive Cabin Air Filter for Passenger Cars)

  • 박영옥;구철오;임정환;김홍룡;손재익
    • 한국대기환경학회지
    • /
    • 제12권3호
    • /
    • pp.279-287
    • /
    • 1996
  • Pressure drop and fractional collection efficiency of automotive cabin air filters were examined to obtain the basic data for the development of high performance domestic cabin air filters. Pressure drop of MA-V100 was higher than that of VF-V100, and it increased with the air flow rate. VF-V100 had longer time to rise the critical pressure drop than that MA-V100 had. Total collection efficiency of MA-V100 for initial and dust loaded conditions was higher than that of VF-V100. Also, fractional collection efficiency of MA-V100 for the fine particles was higher than that of VF-V100. Particla size distribution for the minimum collection efficiency ranged from 0.02 $\mu$m to 0.04 $\mu$m for MA-V100 and it ranged from 0.02 $\mu$m to 0.15 $\mu$m for VF-V100.

  • PDF

충진층식 세정집진기의 집진특성 실험 (An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber)

  • 유경훈;노희환;최은수;김종균
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.

산업용 필터백의 구조에 따른 여과성능 특성 (Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries)

  • 전성민;;이강산;이재랑;김광득;박영옥
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

덕트형 세정집진기의 입자포집 특성실험 (An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber)

  • 유경훈;여국현;손승우;황광호;정진원;김윤신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가 (Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles)

  • 이기혁;김문원;류태우;육세진
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도 (Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks)

  • 한돈희;김일순
    • 한국환경보건학회지
    • /
    • 제46권1호
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.

국내 양돈장의 사육 온도와 밀사율이 구강액 채취율에 미치는 영향 (The effect of temperature and breeding density of piggery on the collection of oral fluid in Korea)

  • 변현섭;김미화;권성애;한미나;한성태;장래훈;정윤수;김석현;전보영
    • 한국동물위생학회지
    • /
    • 제44권4호
    • /
    • pp.217-225
    • /
    • 2021
  • We investigated the effect of temperature and stock density on the collection efficiency of oral fluid in the pig farm in Korea. Three pig farms with similar breeding environmental conditions were selected and four pens of each farm (total 12 pens) were tested for the collection efficiency of oral fluid from pigs. Collection rate was considered as significant when oral fluid was collected from 70% of pigs within a pen. In the case of growing pigs, when internal temperature of pig barn increased by one designated degree (5℃), the oral fluid collection rate significantly decreased by 24.7% (P<0.05). The collection rate of oral fluid also decreased by 7.1% (P<0.05) as the density rate increase by one designated degree (12.5%). It was estimated that the collection efficiency of oral fluid decreased when the internal temperature of pig barn was 30℃ or higher, or barn density is higher 25% or high. On the other hand, in the case of stall-housing sows, unlike growing pigs, there was no significant differences according to the temperature, so oral fluid collection was considered to be efficient even in hot season.

활성탄집진시설의 시간변화에 따른 총탄화수소의 집진효율성 및 경제성에 관한 연구 (A Study on Collection Efficiency And Economy of Total Hydrocarbons in Accordance with Time Changes at Activated Carbon Collection Facility)

  • 김성중;한대희;우인성
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.231-236
    • /
    • 2014
  • In this study, the changes in collection efficiencies due to the time changes of activated carbons were ascertained, and in order to identify the magnitude of adsorption, the before-use and after-use iodine adsorption values were analyzed. In addition, as a result of examining the characteristics of continuous process and non-continuous process and as a result of investigating whether the emission standards would be maintained, the continuous process and printing facilities were seen as not being able to maintain the emission standards. Also were found, in the case of non-continuous process,-taking into consideration the special nature of the job -for 4${\o}$ palletized charcoal, a collection efficiency near 50% was shown even after 96 hours. Also, when the inlet concentration was about 300ppm, it is thought that the emission standards would be maintained if the activated carbons are replaced within at least 96 hours in the case of 4${\o}$ palletized charcoal and the use was deemed pointless in the case of carbon. The results of this study are expected to provide assistance in selecting replacement periods for activated carbons and in selecting absorbents at the project sites, and are expected to be of significant help in the selection of precipitators that can collect total hydrocarbons for compliance of the emission standards.

태양열 집열기 효율곡선에 대한 연구 (The Study of The Collector Efficiency Curve)

  • 신정철
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.198-202
    • /
    • 2014
  • In the solar heat collection system, we can determine how the collector will perform under specific conditions from the efficiency curve. By understanding the basic principles which govern the operation, designers can maximize the output from the collector. Absorptance, transmission and the total heat transfer coefficient were introduced to induce this efficiency curve. Designers who can make use of the implicit information on the curve in this report will generate systems which obtain the best return from their client's investment.