• 제목/요약/키워드: Total coliform bacteria

검색결과 353건 처리시간 0.027초

서울특별시 종로구 대중목욕탕의 수질 중 미생물 오염도 조사 연구 (Investigation of Microbial Contamination of Public Bath in Jongno-gu, Seoul)

  • 김미순;이영민;김성근;서지현;지경희;오지윤;고기동;고광표
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.162-168
    • /
    • 2009
  • The aim of this study is to investigate microbial sanitary condition of public baths in Seoul, Korea. A total of 28 water samples were collected from 14 different public baths and sudatoriums. The prevalence of fecal indicator microorganisms such as total coliform, fecal coliform, and Escherichia coli was characterized. In addition, bacteria in water was membrane filtered by 0.45um nitrocellulose membrane, and the filter was analyzed by both cultivation and PCR amplification of partial 16S rRNA gene. The levels of chlorine were measured for each of water samples. More than 40% of 14 collected water samples, the concentrations of total coliform bacteria exceeded the water quality for bath water guideline. There was no significant correlation between chlorine residue and the presence of total coliform. Various microorganisms including pathogenic microorganisms were identified from cultivation and subsequent analysis of 16s rRNA gene sequences. Our results suggest that appropriate hygiene practice and continuous monitoring is needed for reducing health risk associated with public bathhouses.

路上販賣冷茶의 세균오염에 관한 조사연구 (A Study on Bacterial Contamination of Ice Tea Sold on the Street in Seoul Area)

  • Jang, Jae Seon
    • 한국환경보건학회지
    • /
    • 제12권2호
    • /
    • pp.39-48
    • /
    • 1986
  • This study was carried out to investigate the bacterial contamination of Ice Tea sold on the l street in Seoul area. For this, study 81 samples were collected on the street from July to September, 1985 and were examined on the following items. 1. Degree of bacterial contamination. 2. The relation of the occurrence of fecal coliform and salmonella. 3. The change of bacterial contamination in Ice Tea against temperature. As the results of this study, the following conclusion were obtained. 1. The mean count of total viable bacteria by standard plate count was $6.5{\times}10^3$/ml, the mean count of total coliform and fecal coliform by MPN method were $3.4{\times}10^2$/100ml, 5.5/100ml and those of fecal streptococci was $3.2{\times}10^2$/100ml. 2. The mean count of Staphylococcus aureus was 10.5/ml, the isolated rate of salmonella was 7.41%. 3. In relation to the occurrence of fecal colfform and salmonella, salmonella isolated that for values above $10^2$ fecal coliform 100ml. 4. In the change of bacterial contamination in Ice Tea against temperature, the number of total coliform and fecal coliform increased at $25{\circ}$C, decreased at $4{\circ}$C, but fecal streptococci increased at $25{\circ}$C and $4{\circ}$C.

  • PDF

유통 생식제품의 미생물 분포 및 감마선 조사를 이용한 위생화 (Distribution of Microflora in Powdered Raw Grains and Vegetables and Improvement of Hygienic Quality by Gamma Irradiation)

  • 김동호;송현파;육홍선;정영진;김영지;변명우
    • 한국식품영양과학회지
    • /
    • 제31권4호
    • /
    • pp.589-593
    • /
    • 2002
  • 유통 생씩 5종의 수분 함량 4.22~7.18%의 범위였으며 수분활성은 0.15~0.26의 분포를 보여 미생물에 의한 변패보다는 낮은 수분활성에서도 생존해 있는 병원성 미생물의 제거가 생식의 중요한 품질관리 요소일 것으로 판단된다. 생식의 미생물분포는 Bacillus group $10^4$~$10^{7}$ cfu/g, 사상균류 $10^2$~$10^3$cfu/g, coliform group $10^1$~ $10^4$cfu/g, SS agar plate 분리 enteric bacteria group $10^1$~$10^3$cfu/g의 수준으로 특히 병원성 미생물의 오염가능성이 컸다. 감마선 조사 결과 coliform group, SS agar plate 분리 enteric bacteria group, 그리고 사상균류는 3 kGy의 조사선량에서 완전살균 수준으로 제거되었다. 생식 분포 미생물의 D값은 coliform group은 0.68~0.80 kGy, SS agar plate 분리 enteric bacteria group은 0.59~0.74 kGy, Bacillus group은 1.84~2.18 kGy, 사상균류는 0.36~0.57 kGy의 범위를 나타내었다. 생식제품의 위생화를 목적으로 할 경우 감마선조사 선량은 생식제품에 분포하는 coliform group과 SS agar plate 분리 enteric bacteria group 미생물의 사멸기준인 3~5 kGy의 수준으로 설정하는 것이 바람직할 것으로 사료된다.

TiO2 박막을 이용한 광촉매반응의 응용 (Application of Photocatalytic Reaction Using TiO2 Thin Film)

  • 김영관;김성호;김동현
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.249-254
    • /
    • 1997
  • Photocatalytic reaction using $TiO_2$ thin film was applied for the inactivation of coliform bacteria and the degradation of formic acid. UV processes coupled with and without $TiO_2$ were tested for the river water samples. It took 5 and 15 minutes, respectively, to obtain 99% destruction of coliform bacteria in the total coliform test, which demonstrated the effectiveness of the photocatalytic reaction. Complete degradation of formic acid determined by TOC analysis was observed in 20 minutes by ozone/photocatalysis, while formic acid was degraded as little as about 20% during the first 100 minutes by ozone treatment alone. When ozone was supplied to the $TiO_2/UV$ system, however, it provided a synergetic effect for the degradation of formic acid.

  • PDF

농업용수의 미생물학적 안전성 조사 및 위생지표세균 농도와 병원성미생물 검출률과의 상관관계 분석 (Investigation of Microbial Safety and Correlations Between the Level of Sanitary Indicator Bacteria and the Detection Ratio of Pathogens in Agricultural Water)

  • 황인준;이태권;박대수;김은선;최송이;현정은;나겐드란 라자린감;김세리;조민
    • 한국환경농학회지
    • /
    • 제40권4호
    • /
    • pp.248-259
    • /
    • 2021
  • BACKGROUND: Contaminated water was a major source of food-borne pathogens in various recent fresh produce-related outbreaks. This study was conducted to investigate the microbial contamination level and correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water by logistic regression analysis. METHODS AND RESULTS: Agricultural water was collected from 457 sites including surface water (n=300 sites) and groundwater (n=157 sites) in South Korea from 2018 to 2020. Sanitary indicator bacteria (total coliform, fecal coliform, and Escherichia coli) and food-borne pathogens (pathogenic E. coli, E. coli O157:H7, Salmonella spp., and Listeria monocytogenes) were analyzed. In surface water, the coliform, fecal coliform, and E. coli were 3.27±0.89 log CFU/100 mL, 1.90±1.19 log CFU/100 mL, and 1.39±1.26 log CFU/100 mL, respectively. For groundwater, three kinds of sanitary indicators ranged in the level from 0.09 - 0.57 log CFU/100 mL. Pathogenic E. coli, Salmonella and Listeria monocytogenes were detected from 3%-site, 1.5%- site, and 0.6%-site water samples, respectively. According to the results of correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens by logistic regression analysis, the probability of pathogen detection increased individually by 1.45 and 1.34 times as each total coliform and E. coli concentration increased by 1 log CFU/100mL. The accuracy of the model was 70.4%, and sensitivity and specificity were 81.5% and 51.7%, respectively. CONCLUSION(S): The results indicate the need to manage the microbial risk of agricultural water to enhance the safety of fresh produce. In addition, logistic regression analysis is useful to analyze the correlation between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water.

취반 재고미를 첨가하여 제조한 저지방 분쇄우육의 냉중중 안정성 (Microbiological and Oxidative Stability of Low Fat Ground Beef during Refrigeration)

  • 김혁일
    • 한국축산식품학회지
    • /
    • 제18권4호
    • /
    • pp.301-306
    • /
    • 1998
  • Four low fat ground beef groups containing 10% fat plus 0, 5, 10 and 20% additional cooked lod rice and a control ground beef containing 30% fat were prepared and the analysis for microbiological and oxidative stability were conducted. During 6 days of storage at 4$^{\circ}C$ microbial analysis including total plate count and coliform groups were performed and 2-thiobarbituric acid reactive substance (TBARS) absorbances were measured. The growth rate of total aerobic bacteria and coliform groups tended to increase with the increase in fat content and the amount of added cooked lod rice. Development of oxidative rancidity were not significantly different between 10 and 30% fat ground beef but among the 10% ground beef the rancidity development significantly(p<05) decreased with the in-crease in the amount of added cooked old rice. Low fat ground beef groups were not stable over 3 days during storage at 4$^{\circ}C$.

  • PDF

초등학교 급식의 비빔밥 생산과정에 따른 미생물적 품질평가 (Microbiological Quality Assessment of Bibimbap Production Flow in Elementary School Foodservice)

  • 김복란;채순주
    • 대한가정학회지
    • /
    • 제43권2호
    • /
    • pp.19-31
    • /
    • 2005
  • The purpose of this study was to evaluate the microbiological quality and assure the hygienic safety of the Bibimbap production in elementary school foodservice in accordance with the HACCP(Hazzard Analysis Critical Control Point) program. The time-temperature relationship and the microbiological quality(total plate count and coliform bacteria count) were assessed to find the critical control point(CCP) during each of the production phase. In the pre-preparation phase, the risk factors of the raw ingredients exceeded the standard level suggested by Solberg et al. Mungbean starch jelly, egg and Kochujang were satisfactory in that no coliform groups were observed over the standard TPC level. In particular, there was a high the risk of beef from the early stages in terms of the coliform level. In the pre-preparation phase, green pumpkin had more coliform groups than the standard level even after washed, which calls for special attention to washing, sterilization, secondary infection of the handler, and the required time for pre-preparation of raw vegetables. In the cooking phase, the temperature of the soybean sprout and mungbean starch jelly decreased to 42$^{\circ}C$ and 26$^{\circ}C$, respectively, which was within the risk zone. In particular, mungbean starch jelly had a great risk factor even after boiling in hot water. During the storage stage before serving, a lot of ingredients were exposed to poor management of temperature and time and thus exceeded the standard level in the total plate counts. In particular, the microbiological count of beef was five times the standard level. Green pumpkins and soybean sprouts were left at 15-38$^{\circ}C$ that is within the risk zone for a long period of time after they were cooked. It is highly recommended that the time of the storage stage before consumption should be shortened and that proper devices should be used to prevent proliferation of bacteria. The number of TPC of the utensils was satisfactory enough, but the knife used exceeded the standard level and thus was a risk factor of bacteria proliferation.

도시하수 처리에 의한 미생물 오염의 제거효과에 관한 조사연구(I) -청계천 하수처리장을 중심으로- (An Analysis on Removal Effect of Biological Contaminants in the Process of Municipal Sewage Treatment System - On the Seoul Cheonggye Cheon Sewage Treatment Plant)

  • 유병태;정용
    • 환경위생공학
    • /
    • 제3권1호
    • /
    • pp.27-39
    • /
    • 1988
  • This investigation was carried out to evaluate the removal effect of biological contaminants for the municipal sewage treatment process at Cheonggye Cheon terminal plant which in the first plant for municipal sewage treatment in Seoul area. It was conducted in raw influent, primary treatment water and secondary treatment water from September, 1986 to July, 1987. The results were as follow; 1, The primary treatment could eliminate microbials for $65.38\%$ of total bacteria, $64.35\%$ of total coliform, $62.16\%$ of fecal coliform $69.48\%$ of pseudomonas and $64.70\%$ of fecal streptococci in averages for a year respectively. 2. The secondary treatment could eliminate microbials for $97.50\%$ of total bacteria, $97.30\%$of total coliform, $95.95\%$ of fecal coliform, $97.00\%$ of pseudomonas and $96.53\%$ of fecal streptococci in average for a year respectively. 3. In the detect rate of pathogenic agent, salmonella spp was decreased $12.5\%$ to $4.2\%$ in primary treatment and it was not detected in secondary treatment, shigella spp was detected $4.2\%$ in influent water but it was not detected in primary and secondary treatment. 4. In the seasonal variation of treatment effect, the removal of summer was the highest, and the removal of all item in winter was lower than the other seasons. 5. There was significant correlation between water temperature and microbal all items (P<0.05) $NH_3-N$ and Microbal items (P< 0.01) at raw water.

  • PDF

정수처리에서 서로 다른 공정의 처리효율에 대한 비교분석연구 (Efficiency Evaluation of Different Processes in Drinking Water Treatment)

  • 김형석;이병호
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.597-604
    • /
    • 2011
  • This study was performed to compare finished water quality among three different processes. A detailed assessment of performance was carried out during the five months of operation. Finished water quality was evaluated on the basis of parameters such as Dissolved organic carbon (DOC), $UV_{254}$ absorbance, haloacetic acid formation potential (HAAFP), geosmin, 2-methylisoborneol (2-MIB), heterotrophic bacteria and total coliform bacteria. The treatment processes were Process 1 (coagulation-flocculation-sedimentation-sand filtration-ozone-GAC), Process 2 (coagulation-flocculation-sedimentation -microfiltration-ozone-GAC), and Process 3 (coagulation-flocculation-sedimentation- sand filtration-GAC), compared side by side in the pilot testing. Process 2 was found to have better removal efficiency of DOC, $UV_{254}$ absorbance, HAAFP and heterotrophic bacteria in comparison with process 1 and process 3 under identical conditions. Geosmin, 2-MIB and total coliform bacteria were not detected in finished water from each process.

Assessment of microbial quality in household water tanks in Dubai, United Arab Emirates

  • Khan, Munawwar Ali;AlMadani, Asma Mohammad Abdulrahman Ahmad
    • Environmental Engineering Research
    • /
    • 제22권1호
    • /
    • pp.55-60
    • /
    • 2017
  • Provision of safe, accessible, and good water quality in the community is an important step towards reducing various waterborne illnesses. However, improving the quality of water should include spreading awareness to the public regarding the importance of cleaning their household water tanks. The aim of this study was to investigate the microbial quality of water of household water tanks in Dubai. The water samples from household water tanks were collected from forty houses, and a questionnaire was given to the residents to determine the history of the water tanks. The membrane filtration technique was used to quantify heterotrophic and total coliform bacteria on plate count agar and the violet red bile agar respectively. The overall results of this study have shown that 18 out of total 40 household water tanks contained different types of bacteria concentration level beyond local and widely accepted international standards. The overall results of this study indicated that there is a lack of awareness among residents regarding the importance of maintaining proper sanitation and hygiene of the household water tanks.