• Title/Summary/Keyword: Total astigmatism

Search Result 41, Processing Time 0.02 seconds

The Study of the Abnormal Refraction Eye on the Women Middle and High school Students (여자 중·고등학생들의 굴절이상 눈에 대한 연구)

  • Kim, Douk-Hoon;Shin, Jang-Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.135-140
    • /
    • 1999
  • To investigate the visual acuity of the women middle and high school students, the visual acuity test was performed the object and subject methods. The results were as follows; 1. The eye types were 96.7% positive for myopia, 2.5% for emmetropia, and 0.8% for hyperopia, respectively. 2. The abnormal refraction eyes were 61% positive for simple myopia, 35.2% for myopitic compound astigmatism, 3% for myopic simple astigmatism, and 0.8% for simple presbyopia, respectively. 3. The asix of astigmatism were 95% positive for irregular astigmatism axis, 3% for regular astigmatism axis, and 2% for oblique astigmatism axis, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF

Effectiveness of Overnight Orthokeratology with a New Contact Lens Design in Moderate to High Myopia with Astigmatism

  • Park, Yuli;Kim, Hoon;Kang, Jae Ku;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.229-237
    • /
    • 2021
  • Background and Objectives To assess the effectiveness of overnight orthokeratology (OK) in myopia using a new contact lens design over a one-month wearing period. Materials and Methods Participants were required to have myopia between -3.00 and -7.50D and astigmatism ≤ 2.00 D to participate in the study. The participants underwent OK with the White OK lens® (Interojo, Pyungtek, Korea), which has a 6-curve lens design. Participants were assessed at weeks 1, 2, and 4 using slit-lamp bio-microscopy, and tested for refraction, uncorrected distance visual acuity, and corneal topography. Success was defined as achieving a Logarithm of the Minimum Angle of Resolution (logMAR) ≤ 0.1. Results A total of 46 eligible subjects with a mean age of 23.11 ± 7.89 years were recruited. Baseline logMAR was 1.18 ± 0.30 and a consistent decrease in logMAR was observed from week 1 to week 4. The success rate was 95.35% at week 4. The mean sphere significantly decreased from a mean pre-fitting value of -4.58 ± 1.28 D to a mean value of -0.65 ± 0.69 D at week 4 (p < 0.0001). Statistically significant corneal flattening was detected during keratometry at week 4. Conclusion Overnight OK with the White OK lens is effective for the correction of moderate and high myopia with astigmatism over a one-month wearing period.

Research about the Distribution of Refractive Errors in Distinction of Gender and at Age of Kyonggi Province's Part Area (경기도 일부지역의 성별, 연령별 굴절이상 분포에 관한 연구)

  • Lee, Eun-Hee;Lee, Hee-Jung;Cho, Sung-Il;Paek, Do-Myung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.121-129
    • /
    • 2006
  • Prevalence of refractive error have revealed variation in relation to ethnicity, educational level, age, gender, and social economic status. Especially prevalence of refractive error varies by country, estimation of prevalence of refractive error have shown increase in Asia than in Western world. The present report aimed to investigate the prevalence of refractive errors by the age and gender in Korean population without eye disease. A total of 960 subjects were sampled and their refractive error was determined using Auto refractometer. Prevalence of emmetropia was 29% and that for myopia and hyperopia was 67%, 4%, respectively. Astigmatism was 22%, and the simple astigmatism was 1%. However the compound astigmatism was 99%. Prevalence of refractive errors differed significantly among age and gender group in our results. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 36.6%, 20.7% and 42.7% for right eye and 31.8%, 10% and 58.1% for left eye.

  • PDF

A Study of Accommodative Response on Emmetropia (정시안의 조절반응량에 관한 연구)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Joo, Seog-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.187-192
    • /
    • 2006
  • The purpose of this research was to measurement real accmmnodative response amount of emmetropia using both eyes open-view auto-refractometer. We classified 377(male 146, female 231)eyes showing good naked vision at least 1.0, with a spherical equivalent refraction of under ${\pm}0.50D$ and cylindercal refraction of under -0.75D, from 10 to 59(mean $25.8{\pm}12.4$) years into 5 groups with 10 year interval and analyzed change of the near astigmatism and accommodative response amount to distinction of age. Age comparison, total mean 1.47D, 10 years age group 1.63D, 20 years age group 1.57D, 30 years age group 1.71D, 40 years age group 0.97D, and 50 years age group 0.05D. It was no difference between 10 to 30 years age group, But it showed the decre8.se which is remarkable from above 40 years age group and it does not almost response from above 50 years age group. Sexual difference, the man appeared some highly in male(mean $26.4{\pm}12.3$ years) 1.56D m female(mean $26.4{\pm}12.3$) 1.43D. Near-astigmatism power change, mean +0.12D, 10 years age group +0.06D, 20 years age group +0.16D, 30 years age group +0.09D, 40 years age group +0.05D, and 50 years age group +0,06D. No significant difference of astigmatism powers among the an groups, but from all years age group the astigmatism power appeared more highly far-astigmatism than near-astigmatism. Near-astigmatism axis change in the far-astigmatism changes at under ${\pm}10^{\circ}$ 103 eyes, above ${\pm}10^{\circ}$ rotation clockwise direction 108 eyes, above ${\pm}10^{\circ}$ rotation counter-clockwise direction 101 eyes. It was analyzed near-astigmatism axis change.

  • PDF

Analytic Design Procedure of Three-mirror Telescope Corrected for Spherical Aberration, Coma, Astigmatism, and Petzval Field Curvature

  • Lee, Jong-Ung;Yu, Seung-Moon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.184-192
    • /
    • 2009
  • There are total eight degrees of freedom in designing a three-mirror system. If we correct four kinds of third order aberrations and the system should have the specified effective focal length, the remaining three degrees of freedom can be used for selecting a suitable configuration for a specific application. We suggest an analytic design procedure for a three-mirror telescope system which has a suitably sized secondary mirror and proper separations between mirrors, and is corrected for four kinds of third order aberrations, spherical aberration, coma, astigmatism, and field curvature. Two design examples are shown. One has a compact configuration with off-axial field, the other has relatively long configuration with annular ring field.

The Study on Hansen's Disease of Ametropia (나환자들의 비정시에 대한 고찰)

  • Lee, Hark Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.145-150
    • /
    • 1998
  • To 160 persons(90 men, 70 women) who went to the national hospital of Solok-island with Hansens's disease, I tested the objective refracts test with the product of Cannon Ltd. Co. which RK-3 Auto Ref-keratometer's auto ophthalmoscope. The results were like these. Visual acuity of above 0.7 that can live without glasses was contained 44 men's eyes(24.4%) and 19 women s eyes(13.6%). These result are indicated that men have had more good visual acuity than women. Visual acuity of below 0.6 that cannot do normal life was contained 80.3% of the total patients. And amblyopia of below 0.3 and eyes which cannot be corrected were shown 44.4%(80 men's eyes and 55.7% 78 woman's eyes). Myopia was contained 119 eyes(43), hyperopia was contained 139 eyes (50.4%) and emmetropia was 6.5%. Astigmatism was shown 136 men s eyes (86.6%) and 97 women's eyes(81.5%). These results are indicated what many people accompany with astigmatism. And these ratio had some high percentages men rather than women. Direct astigmatic was contained 37 eyes (11.6%), Indirect astigmatic 81 eyes(25.3%) and Oblique Astigmatic 115 eyes(35.9%). As a of distributed result oblique astigmatic occupied best high point as 49.4% in 233 astigmatism and distributed the opposite direction as compared with normal irregular emmetropia not patient.

  • PDF

Difference between Manifest Refraction (MR) and Cycloplegic Refraction (CR) with Age and Myopic Value (연령과 근시도에 따른 현성굴절검사와 조절마비굴절검사의 비교)

  • Jeong, Woo-Jae;Kang, Ji-Hun;Jeon, In-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.85-91
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate difference between manifest refraction (MR) and cycloplegic refraction (CR) with age and myopic value. Methods: Manifest and cycloplegic refractions were carried out on the patients of 229 myopic patients ($25.3{\pm}11.9$ years old). Results: The average results from a pre- and a postcycloplegic refraction showed a reduction of 0.19 D in myopia, 0.02 D in astigmatism and $1.85^{\circ}$ in astigmatism direction. Change of myopic value was higher in 30~40 age. Total 73 eyes of 229 patients who showed 0.50 diopter (D) in spherical, and a high degree of myopia group showed a higher discrepancy rate. Conclusions: The results found in the comparison of the value of the manifest refraction and cycloplegic refractions showed changes of myopic value was not significant with age of patient, but the group of high degree of myopia showed higher discrepancy rate.

A Correlation between Axis-Rotation and Corneal Eccentricity in Toric Soft Contact Lens Fitting in With-the-rule Astigmatism (직난시안에서의 토릭소프트렌즈 피팅 시 축 회전과 각막이심률과의 상관관계)

  • Park, Hyung Min;Park, Kyounghee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.305-313
    • /
    • 2014
  • Purpose: A correlation between the rotating direction and rotation amount according to the eccentricity was analyzed in the present study when fitting the toric soft contact lens. Methods: One hundred fourteen eyes of with-the-rule astigmatism in 20s and 30s were appropriately applied toric soft contact lens by the guideline of manufacturer and fitting evaluations and analyzed the rotating direction and rotation amount when fixating at primary position and 8 different directions of gaze. The speed of reorientation and the correlation between the rotation amount and cornea eccentricity were also analyzed when rotating $45^{\circ}$ each toward the temporal and nasal direction. Results: The cornea eccentricity and rotation amount was shown positive correlation. For the gaze of direction, it was identified that the gaze of directions other than the gaze of direction towards the nasal and temporal had correlation, and among them, the gaze of directions to superior and the superior-temporal showed the tendency of decreasing rotation amount as the cornea eccentricity increased. On the contrary, the gaze of direction towards the inferior, inferior-temporal, superior-nasal, and inferior-nasal showed tendency of increasing rotation amount as the cornea eccentricity increased thus, it was identified that the cornea eccentricity showed different correlation according to the gaze of direction. For the case of re-orientational speed, the speed of lens reorientation in the group having the smallest corneal eccentricity was fastest in both direction but was not significantly different. Conclusions: Considering cornea eccentricity to current method of prescribing toric soft contact lens which is based on total astigmatism, it will be helpful to establish the optimal axis stabilization.

A Comparison of Lens Centrations on Cornea with RGP Lens Fitting by the Measured Values using Keratometer and Corneal Topography (각막곡률계와 각막 지형도 검사에서의 측정값을 이용한 RGP 렌즈 피팅시 각막에서의 중심안정위치 비교)

  • Kim, So Ra;Park, Sang-Il;Lee, Se Eun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2011
  • Purpose: The present study was conducted to compare the centration of RGP lens on cornea when lens was fitted based on keratometric astigmatisms measured by keratometer and the lens centration when fitted by corneal topography. Methods: Thirty eight eyes of 19 male and female in their twenties were applied RGP lens with 9.9 mm of diameter by the keratometric astigmatisms classified by the measurement with a keratometer. Then, lens centrations were estimated using high speed camera and compared with the lens centration when fitted by total keratometric astigmatism using corneal topography. The relationship of the steepest location of cornea and lens centration was further compared. Results: With the rule astigmatism, lens centration was not changed even with the difference in central and total keratometric astigmatisms. When the relationship of the steepest part of cornea measured by corneal topography and lens centration was analyzed, the lens centration in vertical direction was exactly correlated with the steepest part of cornea in 52.3% of subjects. In the case of non-correlation, the steepest part of cornea was mostly upper part of cornea, however, lens centration was located on lower part of cornea. The lens centration in horizontal direction was exactly correlated with the steepest region of cornea in 65.6% of subjects. In non-correlated case, the difference in cornea curvatures between the steepest and the flattest parts was smaller than 0.05 mm in 76.9% of subjects. Conclusions: From these results, we conclude that corneal topographic patterns may more contribute the centration of RGP lens on cornea than the difference in central and total keratometric astigmatisms.

Comparison and Analysis of Keywords in the Korean Ophthalmic Optics Society Articles to MeSH Terms (한국안광학회지 게재 논문의 주제어와 MeSH 용어의 비교·분석)

  • Kim, Daeyoon;Lee, Min Hyung;Choi, Moonsung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.83-90
    • /
    • 2016
  • Purpose: The purpose of this study is to compare and analyze keywords of articles in the Korean Ophthalmic Optics Society to MeSH (Medical Subject Headings) terms. The study hopes to enhance the understanding and usage of MeSH and give fundamental information to the Korean Ophthalmic Optics Society in advance. Methods: A total of 1952 keywords from 409 informative articles published from 2004, Vol 9(1) to 2016, Vol 21(1) were compared with MeSH terms according to the criteria of complete coincidence, incomplete coincidence and complete incoincidence. Results: 439 keywords (22.4%) were completely coincident with MeSH terms, 815 keywords (41.8%) were incompletely coincident with MeSH terms and 693 keywords (35.5%) were completely incoincident with MeSH terms. The most used keyword in MeSH terms is in the order of Myopia, Astigmatism and visual acuity. For the incompletely coincident keywords Refractive error, Soft contact lens, and Phoria were used the most. Finally, the most used keywords in the category of completely incoincident were Accommodative lag and Pseudomonas aeruginosa. Conclusions: It is highly recommended that MeSH terms are selected as controlled keywords to increase usage of searced Korean Ophthalmic Optics Society articles in MEDLINE.