• Title/Summary/Keyword: Total Load

Search Result 2,599, Processing Time 0.035 seconds

Development of a Groundwater Quality Sampling Method for Livestock Excreta Survey (가축분뇨실태조사를 위한 지하수 오염현황조사 지점 선정 방법 개발)

  • Kim, Deok-Woo;Ryu, Hong-Duck;Baek, Unil;Kim, Sunjung;Shin, Dong Seok;Lee, Jae Gwan;Chung, Eu Gene
    • Journal of Environmental Science International
    • /
    • v.28 no.1
    • /
    • pp.37-54
    • /
    • 2019
  • The groundwater quality through livestock excreta survey based on "Act of the management and use of livestock excreta" was investigated by selecting sampling sites within 1 km of the farmland without considering hydrogeological units. However, these sites can be affected by various pollution sources such as chemical fertilizers and livestock excretions. Additionally, the effects of pollution sources on groundwater quality in the sites cannot be clearly distinguished from naturally occurring backgrounds. In this study, a method was developed to select the sampling sites for groundwater quality through livestock excreta survey in order to understand the effects of pollution sources especially livestock excreta. First, the concentrations of nitrate within the radius of 200 m, 300 m, 500 m and 750 m, respectively, from the farms regarded as pollution sources in hydrogeological units were compared in 2016-2017. All the nitrate concentrations at 200 - 500 m from the farms exceeded a background concentration, 13.3 mg/L. Those at 750 m and the background concentrations measured by the Ministry of Environment were comparable. Therefore, the appropriate radius was suggested as 500 m for livestock excretions survey. In this study, the areas within 500 m from the farms could be considered under the influence of livestock excretions, while those beyond 500 from the pollution sources as background in hydrogeological units. The developed method was validated by applying it to the sites selected based on both administrative divisions and watersheds for livestock excretion survey. The average densities for the developed method were 0.82 and 0.39 points/km2, respectively, which were considered as appropriate levels according to those of the European Environmental Agency.

Total assessment for phosphorus input load of public wastewater and livestock manure treatment facilities in Korea (우리나라 공공하수처리시설 및 가축분뇨공공 처리시설의 인(P) 유입부하량에 대한 총량평가)

  • Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.325-335
    • /
    • 2018
  • The annual total phosphorus load caused by public wastewater, nightsoil and livestock manure treatment facilities in Korea has been examined macroscopically. Annual domestic average phosphorus (P) inflows through the income of phosphate rock for the last five years (2012 - 2016) were analyzed as 76,598 tons/year. As of the year 2015, the total loadings of phosphorus attributed to public wastewater treatment facilities, nightsoil treatment facilities and livestock wastewater were estimated as 30,269 tons/year, 1,909 tons/year and 18,138 tons/year, respectively. Considering the amount of phosphorus imports, the annual phosphorus load from wastewater, livestock wastewater and excretions is equivalent to 39.5%, 23.7%, 2.5% and totally 65.7%(39.5% + 23.7% + 2.5%). Therefore, the introduction of phosphorus recovery and recycling processes for the public wastewater and livestock manure treatment facilities has been found to be effective because it could reduce the import amount of phosphate rock by up to 60% or more.

A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building (사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석)

  • Seo, Byeong-Mo;Yu, Byeong-Ho;Lee, Kwang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

A Study on the Suggestions for Standard Flow Conditions considering the Variation of Stream Flow and Water Quality for the Management of Total Maximum Daily Loads (하천 유량.수질변화 특성을 고려한 수질오염총량관리 기준유량 조건에 관한 연구)

  • Park, Jun Dae;Oh, Seung Young;Choi, Yun Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.426-435
    • /
    • 2012
  • The variation of stream flow is the one of the most important factors which influence on that of water quality in the unit watershed. The target water quality goal is established and permissible load is allotted in the base of the standard flow condition along with its water quality for the management of Total Maximum Daily Loads (TMDLs). A standard flow selected could cause problems in the load allotment if it was not properly arranged. This study reviewed the acquisition of water quality data, the self-variation and the retainability in water quality on the specific flow conditions. This study also proposed the median and the adjusted average flow condition out of general flow conditions as alternative standard flow conditions. It is considered that the alternatives can make the water quality data easily acquired and the water quality representativeness more enhanced on the standard flow conditions.

Estimation of Nonpoint Discharge Coefficient for the Management of Total Maximum Daily Load - Rainfall Discharge Ratio on the Specific Design Flow (수질오염총량관리를 위한 비점배출계수 산정 - 특정 기준유량 시기의 강우배출비)

  • Park, Jundae;Park, Juhyun;Rhew, Doughee;Jeong, Dongil
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.452-457
    • /
    • 2008
  • Nonpoint source (NPS) pollution is caused by rainfall moving over and through the ground. As the runoff moves, it picks up and carries away various pollutants from NPS. The discharge pattern of NPS pollutant loads is affected by the distribution of the rainfall during the year. This study analysed relationship between the rainfall event and the stream flow rate, and estimated the rainfall discharge ratio on the specific design flow which can be used as nonpoint discharge coefficient for the estimation of NPS pollution load. It is considered that nonpoint discharge coefficient can be effectively used for the calculation of NPS pollution load at the time of water quality modelling for the management of Total maximum daily load (TMDL).

Computer simulation of cooling load and cool-down performance in an automotive air-conditioning system (자동차 냉방부하 계산 및 초기 냉방성능 시뮬레이션)

  • Oh, S.H.;Lee, C.W.;Won, S.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.364-375
    • /
    • 1997
  • The fundamental theory and technical approach to aid design and development of an automotive air-conditioning system are presented. The evaluation methods for transient cooling load transferred to a passenger compartment and simulation of automotive air-conditioning components are outlined. The structure of the computer program, the experiemntal correlations, and the simulation results are also included. The total cooling load of the white-colored car is reduced upto 5% for that of the black-colored car when the car is running. Using the infrared reflectance glass, we can also obtain 5% reduction of the total cooling load for the common glass.

  • PDF

Identification of acrosswind load effects on tall slender structures

  • Jae-Seung Hwang;Dae-Kun Kwon;Jungtae Noh;Ahsan Kareem
    • Wind and Structures
    • /
    • v.36 no.4
    • /
    • pp.221-236
    • /
    • 2023
  • The lateral component of turbulence and the vortices shed in the wake of a structure result in introducing dynamic wind load in the acrosswind direction and the resulting level of motion is typically larger than the corresponding alongwind motion for a dynamically sensitive structure. The underlying source mechanisms of the acrosswind load may be classified into motion-induced, buffeting, and Strouhal components. This study proposes a frequency domain framework to decompose the overall load into these components based on output-only measurements from wind tunnel experiments or full-scale measurements. First, the total acrosswind load is identified based on measured acceleration response by solving the inverse problem using the Kalman filter technique. The decomposition of the combined load is then performed by modeling each load component in terms of a Bayesian filtering scheme. More specifically, the decomposition and the estimation of the model parameters are accomplished using the unscented Kalman filter in the frequency domain. An aeroelastic wind tunnel experiment involving a tall circular cylinder was carried out for the validation of the proposed framework. The contribution of each load component to the acrosswind response is assessed by re-analyzing the system with the decomposed components. Through comparison of the measured and the re-analyzed response, it is demonstrated that the proposed framework effectively decomposes the total acrosswind load into components and sheds light on the overall underlying mechanism of the acrosswind load and attendant structural response. The delineation of these load components and their subsequent modeling and control may become increasingly important as tall slender buildings of the prismatic cross-section that are highly sensitive to the acrosswind load effects are increasingly being built in major metropolises.

Characteristics of Pollutant Load from a Dam Reservoir Watershed - Case study on Seomjinkang Dam Reservoir - (댐저수지 유역의 오염부하 유출특성 - 섬진강댐 저수지를 중심으로 -)

  • Lee, Yo-Sang;Gang, Byeong-Su
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.757-764
    • /
    • 2000
  • The investigation of water quality was performed at the upstream of Seomjinkang dam reservoir for the examination of pollutant load characteristics of the reservoir watershed during flood and normal flow periods. The highest water quality concentration was occurred at Y ongsan during normal flow period where it has been more polluted by population and livestock than other sites. Pollutant load varied depending on the sampling site, rainfall intensity and antecedent precipitation during the rainy period. Based on the water quality data measured from 1998 to 1999, the average concentration during rainy period was much higher than that of non~rainy period: BOD was 1.2~1.4 times, COD 1.2~1.7 times, SS 2.6~5.4 times, T-N 2.3~3.0 times, and T-P 2.4~7.5 times respectively. When the pollutant load measured during 7 different rainy periods in 1999 was compared with total pollutant load in 1999, the BOD and COD load measured during the 7 different rainy periods were 28% that is about 1.6 times as high as those of 1999. On the other hand, the rainfall amount measured during the 7 different rainy periods was about 17.5% of total rainfall amount in 1999. The total pollutant load of TN and TP measured during the 7 different rainy periods was almost 50% of total TN and TP loads in 1999. In case of SS, it was 72.8%. It was concluded that the inflow of pollutants into the lake during the rainy period held a high portion of total inflow in 1999. It was suggested that long~term water quality monitoring be performed to better quantity pollutant load to the lake especially during rainy periods.eriods.

  • PDF

Seasonal Variation of Pollutant load flowing into Yeong-Il bay (영일만 유입오염부하량의 계절 변동에 관한 연구)

  • Yoon, Han-Sam;Lee, In-Cheol;Ryu, Cheong-Ro;Park, Jong-Hwa
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.100-107
    • /
    • 2002
  • This study investigates the seasonal variation and spatial distribution characteristics of pollutant load, as executing the quantity valuation of pollutant load inflowing into Yeong-Il bay from on-land including the Hyeong-san river. Annual total pollutant generating rate from Yeong-Il bay region are 202ton to BOD, 620ton to SS, 42ton to T-N, 16ton to T-P respectively, if expressly point out, pollutant generating rate from the Hyeong-san river is the greatest, which BOD ratio is 78.2%, SS 88.5%, T-N 62.5%, T-P 73.1%. As calculating Tank model with input value of daily precipitation and evaporation of 2001 year in drainage basin of the Hyeong-san river, Estimated result of the annual total river discharge effluencing from this river is $830{\times}106m^3$. As result to estimating annual total effluence rate outflowing at the rivers from each drainage basins, annual total inflow pollutant rate are BOD 10,633ton, SS 19,302ton, T-N 15,369ton, T-P 305ton. The III basin which is population congestion region of the Pohang-city drain away a good many pollutant load than the V basin including the Neang-Chun with wide drainage area. Especially, a great many T-N than T-P inflow into Yeong-Il bay. The accumulation of pollutant load effluenced from on-land will happen on at the inner coast region of Yeong-Il bay, finally we would make a prediction that the water quality will take a bad turn.

  • PDF