• 제목/요약/키워드: Total Load

검색결과 2,605건 처리시간 0.03초

금강수계에서 총인관리의 확대 필요성 (Necessity for Expansion of Total Phosphorus Management in the Geum River Watershed)

  • 박재홍;이재관;오승영;류덕희
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.400-408
    • /
    • 2013
  • Total phosphorus was set as a target indicator to prevent eutrophication and algae growth, etc., in three major rivers (Nakdong River, Geum River and Yeongsang/Seomjin River) for the second phase (2011 ~ 2015) in total maximum daily loads (TMDLs) system. However, total phosphorus management was restrictively introduced, i.e., upstream of the Lake Daechung, in the Geum River watershed. Total phosphorus concentration and trophic levels in downstream of the Lake Daechung (include Mangyeong and Dongjin rivers) were increased more than upstream. Therefore, it is necessary to expand total phosphorus management in all watersheds of the Geum River. If total phosphorus was managed in all area of the Geum River watershed, it is possible to decrease total phosphorus concentration and trophic levels, and solve the unbalanced water quality between up and downstream of the Lake Daechung.

낙동강수계 수질오염총량관리를 위한 유량조사 평가 (Evaluation on Actual Discharge Data for TMDL in Nakdong River Basin)

  • 김경훈;김용석;박배경;윤종수;신찬기
    • 환경위생공학
    • /
    • 제23권4호
    • /
    • pp.65-71
    • /
    • 2008
  • To drive efficiently total water pollution load management, needs to calculate the exact load emissions, pollution load allocation and implementation evaluation in each unit area of watershed and accurate and regular flow of data. For these reasons, the Nakdong River TMDL Research Center has produced directly or indirectly in the average interval of eight days (30 times or more / year) 41 points for unit area of the total water pollution load management and 8-point of municipal requirement for a total of 49 branches as a flow data in 2004 from August. This acquired the survey flow is evidence of trends and changes each point in the Nakdong River based on time, such as 10 years based on average design flow available to the foundation of the summit as the major water policy is to be utilized. This study was performed on actual discharge measuring data and introduced performance results each drainage basin of Nakdong River from 2004 to 2008 over the total of past five years.

하천관개지역 광역논에서의 영양물질의 물질수지 (Nutrient Balance in the Paddy Fields Watershed with a Source of River Water)

  • 이정범;이재용;이사굉;장정렬;장익근;김진수
    • 한국농공학회논문집
    • /
    • 제56권5호
    • /
    • pp.11-19
    • /
    • 2014
  • The objective of this research was to investigate concentration and load of nutrients such as total nitrogen (TN), nitrate nitrogen ($NO_3$-N) total phosphorous (TP), and phosphate phosphorous ($PO_4$-P) in a 23.4-ha paddy fields watershed with river water source. Water samples for irrigation water, drainage water, ponded water and groundwater were collected, and irrigation and drainage water were measured at 5~10 day intervals during normal days and at 2~6 hours intervals during three storm events. The amount of irrigation water in the study area was over 2,000 mm, which is almost identical to that in the area irrigated from a large reservoir but much more than that in the area irrigated from a pumping station. Mean flow-weighted concentrations of TN and TP in irrigation water were 2.8 and 0.15 mg/L, respectively, higher than those in the area irrigated from a large reservoir or a pumping station. The ratios of irrigation load to total inflow load for TN and TP were 88 %, and the ratios of surface outflow load to total outflow load for TN and TP were over 90 %, indicating that total nutrient load may be greatly affected by water management. The nutrient loads per area in the study area were estimated as TN 21.1 kg/ha and TP 1.1 kg/ha. Especially, the TP load per area in the study area was smaller than that in the area irrigated from a large reservoir or a pumping station. This may be because outflow load is not high likely due to sedimentation of particulate P and irrigation water load is high due to high TP concentration in irrigation water and high amount of irrigation water.

사무소 건물에서 냉동기의 대수제어를 통한 냉동기 거동 특성 및 에너지 절감 효과 분석 (Detailed Analysis on Operation Characteristics and Cooling Energy Saving Effect of Chiller Staging in an Office Building)

  • 서병모;손정은;이광호
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.137-144
    • /
    • 2016
  • Commercial buildings account for a significant proportion of the total building energy use in Korea, and cooling energy, in turn, accounts for the largest proportion of total energy consumption in commercial buildings. Under this circumstance, chiller staging is considered to be a reasonable and practical solution for cooling energy saving. In this study, the part-load ratio and the operating characteristics of a vapor compression chiller were analysed within an office building. In addition, energy consumption among different chiller staging schemes was comparatively analysed. As a result, significant proportions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range from 0% through 50%, and thus energy consumption was significantly affected by the chiller COP at low part-load conditions, indicating that the chiller operation at the part-load is an important factor in commercial buildings. In addition, utilizing a sequential chiller staging scheme can reduce the annual cooling energy usage by more than 10.3% compared to operating a single chiller.

오염부하지속곡선(LDC)을 이용한 수질오염총량관리 단위유역 목표수질 달성여부 평가방법 (Methodology for the Identification of Impaired Waters Using LDC for the Management of Total Maximum Daily Loads)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.693-703
    • /
    • 2012
  • Load Duration Curve(LDC) is a useful tool for analyzing water quality characteristics under various stream flow conditions. This study investigated the methods to identify impaired waterbodies in the assessment of water quality goal attainment by using LDC for the management of Total Maximum Daily Loads (TMDLs). Three methods were proposed. Non-typical regime exclusion method is a method to exclude water quality observations in the non-typical extreme flow conditions in order to minimize the influence of non-ordinary water quality. Flow regime weighted average method is a method to calculate weighted mean water quality instead of arithmetic mean in order to consider water characteristics properly on stream flow regime in addition to the effect of Non-typical regime exclusion method. Load exceeded interval comparison method is a method to compare the intervals between the attained and non-attained load duration periods on the LDC. The assessment of water quality goal attainment can be performed more reasonably and precisely considering water quality variations on stream flow conditions by applying these proposed methods.

성별 및 연령별 손 위생관리의 비교 (Gender and Age Differences in Hand Hygiene Practices among the General Population)

  • 김종규
    • 한국환경보건학회지
    • /
    • 제45권3호
    • /
    • pp.213-221
    • /
    • 2019
  • Objective: This study was performed to evaluate gender and age differences in hygienic behavior among the general population, focusing on hand-washing habits and the microbial load of hands. Methods: A self-administered questionnaire survey and a separate microbial examination were performed. The Pearson's correlation between hand-washing habits and microbial load was analyzed. Results: In the questionnaire survey on hand-washing habits, gender differences were found in hand-washing frequency, use of hand-washing agents, and hand drying methods (p<0.05). Age differences were found in numbers of washing parts of the hands and also in hand drying methods (p<0.05). Females showed better habits washing hands than did males, as did older people compared to younger. In the microbial examination of indicator bacteria on their hands, younger people tended to show a higher load of total aerobic bacteria than did the older, and females showed a higher load of total coliforms than did males (p<0.05). There were significant relationships between the load of total aerobic bacteria and hand-washing frequency, duration, and method of turning-off water (p<0.05). Conclusions: Although females were expected to show a better practice of hand-washing than were males based on the survey results, they showed a higher level of total coliforms in the hand examination. The older age group showed better hand-washing habits than did the younger age group and had less total aerobic bacteria on their hands. These inter-gender and age differences highlight the need for development and implementation of gender-and age-specific educational programs or campaigns.

오염원 공간분석 및 오염부하지속곡선을 통한 맞춤형 수질오염총량제 추진방안 연구 (Study on the Application of Spatial-analysis of Pollutants and Load Duration Curve for Efficient Implementation of TMDLs system)

  • 박배경;류지철;나은혜;서지연;김용석
    • 대한환경공학회지
    • /
    • 제39권12호
    • /
    • pp.655-663
    • /
    • 2017
  • 현재 수질오염총량제(이하 총량제)에서는 단위유역 말단의 목표수질만 만족할 수 있는 조건에서의 유역 관리를 진행해 왔으며 이로 인해 우선관리가 필요한 지류에 대한 집중적 관리와 오염원 공간분포 특성을 고려한 삭감대책을 마련하는데 제한점이 있다. 본 연구에서는 이러한 문제를 해결하기 위하여 장기적으로 조사된 유량 및 수질자료를 이용한 오염부하지속곡선 기법과 오염원 및 오염부하량 공간분포 특성 분석 방법을 현행 총량제 이행평가 방법으로 적용하였다. 적용유역은 기존 총량제가 시행되고 있는 진위천 수계를 대상으로 하였다. 본 연구방법 적용 결과, 진위천 수계에서는 황구지천 지류가 집중 관리 되어야 하며 진위천 지류는 우선관리에서 제외되는 것으로 나타났다. 또한 황구지천 중류 구간에서 추가적으로 비점삭감계획이 필요하며, 하류 구간에서는 축산에 대한 저감대책이 필요할 것으로 분석됐다. 본 연구에서 제안한 새로운 방법은 향후 총량제에서 유역 전체의 건강성을 높이는데 매우 효과적으로 사용될 수 있을 것으로 판단된다.

수질오염총량관리 단위유역별 오염물질 배출부하량 특성분석 - 금강수계를 대상으로 (Characterization on the Pollution Discharge Load at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin)

  • 박준대;최옥연;오승영
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.786-795
    • /
    • 2012
  • Water quality management should be focused on the pollution concentrated area so that the improvement of water quality can be achieved effectively for the management of Total Maximum Daily Loads (TMDLs). It is necessary to consider discharge characteristics in the TMDL plan. This study analysed discharge characteristics such as pollution generation and discharge load density, and reduction potential by each unit watershed, and categorized the unit watershed into four groups according to its discharge load characteristics. This analysis can be used as helpful information for the prioritization of pollution reduction area and selection of pollution reduction measures in the development of TMDL plans.

Behavior of piled rafts overlying a tunnel in sandy soil

  • Al-Omari, Raid R.;Al-Azzawi, Adel A.;AlAbbas, Kadhim A.
    • Geomechanics and Engineering
    • /
    • 제10권5호
    • /
    • pp.599-615
    • /
    • 2016
  • The present research presents experimental and finite element studies to investigate the behavior of piled raft-tunnel system in a sandy soil. In the experimental work, a small scale model was tested in a sand box with load applied vertically to the raft through a hydraulic jack. Five configurations of piles were tested in the laboratory. The effects of pile length (L), number of piles in the group and the clearance distance between pile tip and top of tunnel surface (H) on the load carrying capacity of the piled raft-tunnel system are investigated. The load sharing percent between piles and rafts are included in the load-settlement presentation. The experimental work on piled raft-tunnel system yielded that all piles in the group carry the same fraction of load. The load carrying capacity of the piled raft-tunnel model was increased with increasing (L) for variable (H) distances and decreased with increasing (H) for constant pile lengths. The total load carrying capacity of the piled raft-tunnel model decreases with decreasing number of piles in the group. The total load carrying capacity of the piles relative to the total applied load (piles share) increases with increasing (L) and the number of piles in the group. The increase in (L/H) ratio for variable (H) distance and number of piles leads to an increase in piles share. ANSYS finite element program is used to model and analyze the piled raft-tunnel system. A three dimensional analysis with elastoplastic soil model is carried out. The obtained results revealed that the finite element method and the experimental modeling are rationally agreed.

고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구 (A FINITE ELEMENT ANALYSIS ON THE 3-UNIT FIXED PROSTHESIS SUPPORTED WITH A NATURAL TOOTH AND ANGLE VARIABLE IMPLANT)

  • 고현;우이형;박남수
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.580-610
    • /
    • 1993
  • The purpose of this study was to analyse the deflection and stress distribution at the supporting bone and it's superstructure by the alteration of angulation between implant and it's implant abutment. For this study, the free-end saddle case of mandibular first and second molar missing would be planned to restore with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder type osseointegrated implant was placed at the site of mandibular second molar for abutment. The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were created, a standard model at $0^{\circ}$ and 12 models created by changing the angulation between implant and implant abutment as increasing the angulation mesially and distally with $5^{\circ}$ unittill $30^{\circ}$. The preprocessing decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and SUN-SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load 1) and distributed load(load 2) at the reference points. The results were as follows : 1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under concentrated load was largest of all, and that at the apex of implant was least of all, and the amount of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all, and that at the apex of implant was least of all. 2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased according to the reference points. But the order according to the amount of total deflection was not changed except apex of second premolar and central fossa of implant abutment under concentrated load during distal inclination. 3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the distal margin of second premolar under distributed load was largest of all, and that at the apex of Implant was least of ail. 4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant were increased under concentrated load and distributed load, but those were increased remarkably under distributed load and so that at $30^{\circ}$ mesial inclination was largest of all. 5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant were increased remarkably under concentrated load and distributed load, and so those at $30^{\circ}$ distal inclination were largest of all.

  • PDF