• Title/Summary/Keyword: Total Load

Search Result 2,611, Processing Time 0.03 seconds

The Impact of Nuclear Power Generation on Wholesale Electricity Market Price (원자력발전이 전력가격에 미치는 영향 분석)

  • Jung, Sukwan;Lim, Nara;Won, DooHwan
    • Environmental and Resource Economics Review
    • /
    • v.24 no.4
    • /
    • pp.629-655
    • /
    • 2015
  • Nuclear power generation is a major power source which accounts for more than 30% of domestic electricity generation. Electricity market needs to secure stability of base load. This study aimed at analyzing relationships between nuclear power generation and wholesale electricity price (SMP: System Marginal Price) in Korea. For this we conducted ARDL(Autoregressive Distributed Lag) approach and Granger causality test. We found that in terms of total effects nuclear power supply had a positive relationship with SMP while nuclear capacity had a negative relationship with SMP. There is a unidirectional Granger causality from nuclear power supply to SMP while the reverse was not. Nuclear power is closely related to SMP and provides useful information for decision making.

A Study on the Hand Values of Hanji Paper Yarn Fabric Treated with Persimmon Juice (감즙 처리된 한지사 소재의 Hand Value에 관한 연구)

  • Choi, Kyeong-Eun;Rhie, Jeon-Sook;Jung, Woo-Young
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.12 no.4
    • /
    • pp.197-206
    • /
    • 2010
  • The purpose of this study is to dye hanji/cotton fabrics using persimmon juice and to investigate the change in the hand fabrics. Using the Kawabata Evaluation System, we have examined the changes in the physical properties, primary hand value and total hand value. The dynamic characteristics of hanji/cotton fabrics have been explored by tensile, shear, bending, compression, surface properties, thickness and weight. As a result, it can be seen that the linearity of load-extension and tensile resilience are increased with the increase of the concentration and dyeing times of persimmon juice and tensile energy is decreased in the same condition. These behaviors are shown in the compression properties. Although the mechanism of persimmon juice dyeing has been widely discussed, it means that the fabrics dyed with persimmon juice become stiffened and the elasticity is increased with the introduction of persimmon on the fabrics studied. Bending rigidity and hysteresis of the bending moment are increased with the increase of the concentration and dyeing times of persimmon juice. Also, Geometrical roughness, expressed in SMD is increased with increasing the concentration and dyeing times of persimmon juice, compared with as-received. It indicates that these results are due to the geometric structure of hanji yarn and the introduction of persimmon juice on the fabrics studied. The fullness and softness with the soft feeing are increased a little due to the tannin component of persimmon juice introduced on the fiber surface.

  • PDF

Effectiveness and Tolerance of a Locust Bean Gum-Thickened Formula: A Real-Life Study

  • Tounian, Patrick;Meunier, Leo;Speijers, Gerrit;Oozeer, Raish;Vandenplas, Yvan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.23 no.6
    • /
    • pp.511-520
    • /
    • 2020
  • Purpose: Thickened infant formulas reduce regurgitation frequency and volume. Because the digestive tolerance of locust bean gum-containing formulas is controversial, the effectiveness and tolerance of a locust bean gum-thickened formula in infants presenting with regurgitation was evaluated. No other interventions were allowed during the 1 month follow-up period. Methods: We conducted an open, prospective, observational study of a locust bean gum-thickened formula administered to infants presenting with moderate to severe regurgitation according to parents during 1 month. Effectiveness and tolerance were assessed by evaluating gastrointestinal symptoms and quality of life indicators. Results: A total of 2,604 infants with an average age of 9.3±4.3 weeks were included in this 1 month trial. Regurgitation frequency and estimated volume decreased significantly (p<0.001) and the episodes were resolved completely in 48% of the infants. A significant decrease in duration of crying and episodes of gas (p<0.001), with improvement in quality of life parameters, was observed. Stool frequency increased and stool consistency softened (p<0.001) to levels within the physiologic range, consistent with the increased fiber load (0.42 g/100 mL). Conclusion: Locust bean gum-thickened formula decreased infant regurgitation, was well tolerated, and improved parental quality of life. Stool composition and frequency of the infants remained within the physiologic range.

A study on the characteristics of planar type inductively coupled plasma and its applications on the selective oxide etching (평면형 유도결합 플라즈마의 특성 및 선택적 산화막 식각 응용에 관한 연구)

  • 양일동;이호준;황기웅
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.1
    • /
    • pp.91-96
    • /
    • 1997
  • The electrical characteristics and the plasma parameters of planar inductively coupled plasmas (ICP) have been measured. The resistance of the total load including the coil and the plasma varied from 1 to 4 W and the inductance from 1.5 m to 2 mH when the power was changed from 100 to 1000 W and the pressure from 1 to 10 mTorr. The density of electron measured by Langmuir probe was over $10^{11}/\textrm{cm}^3$ and the temperature varied between 3 and 5 eV as the process conditions were changed. Bias modulation was adopted as a new method to improve the selectivity of $SiO_2$on Si in $C_4F_8$ (octafluorocyclobutane) plasma. The selectivity was improved as the duty ratio decreased, but the etch rate of $SiO_2$decreased below 400$\AA$/min. $H_2$addition to $C_4F_8$ plasma showed that the etch selectivity could be higher than 50 and the etch rate of $SiO_2$over 2000$\AA$/min when 60% $H_2$was added.

  • PDF

Determination of First Flush Criteria in Highway Stormwater Runoff using Dynamic EMCs (동적 EMC를 이용한 고속도로 초기우수 처리 기준 산정)

  • Kim, Lee-Hyung;Lee, Eun-Ju;Ko, Seok-Oh;Kim, Sung-Gil;Lee, Byung-Sik;Lee, Joo-Kwang;Kang, Hee-Man
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.294-299
    • /
    • 2006
  • The Ministry of Environment in Korea has introduced Total Pollution Load Management System (TPLMS) in major 4 large rivers to protect the water quality from possible pollutants. In order to successfully achieve the TPLMS, the nonpoint source should be controled by applying the best management practices in highly polluted areas. Of the various nonpoint sources, the highways are stormwater intensive landuses because of its high imperviousness and high pollutant mass emissions. The EMC (Event Mean Concentration) is an important parameter to correctly determine the pollutant mass loadings from nonpoint sources. However, it has wide ranges because of various reasons such as first flush phenomenon, rainfall and watershed characteristics. Even though the EMC is closely related to the first flush phenomenon, the relationship have not proven until present. Therefore, in this paper, the dynamic EMC method will be introduced to clearly make the relationship between EMC and first flush phenomenon. Also by applying the dynamic EMC method to monitored data, we found that the highly concentrated stormwater runoff was washed off within 20~50 minutes storm duration. The first flush criteria for economical treatment was also determined to 5~10 mm (mean=7.4 mm) as a cumulative rainfall.

Estimation of TOC Concentration using BOD, COD in Runoff from Paddy Fields (영농기간동안 논 유출수 BOD, COD 자료를 이용한 TOC 농도 추정)

  • Choi, Dongho;Jung, Jaewoon;Yoon, Kwangsik;Lee, Kyoungsook;Choi, Woojung;Lim, Sangsun;Park, Hana;Yim, Byungjin;Hwang, Taehee
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.813-818
    • /
    • 2012
  • BOD and COD are currently used for water quality indices, but adoption of TOC for TMDL (Total Maximum Daily Load) is being suggested. Estimation of TOC using existing BOD and COD data is very important to diagnosis water quality trend when TOC is used for water quality index of organic matter in the future. The relationships between BOD COD and TOC in runoff from paddy fields were investigated during 2008-2011. The observed mean concentration of EMCs (Event Mean Concentration) for BOD, COD, TOC were 3.87, 10.97, 7.26 mg/L respectively. The correlation coefficients between BOD-TOC and COD-TOC were 0.42, 0.73, respectively. The coefficient of determination of regression equation for BOD-TOC and COD-TOC were 0.18, 0.53 respectively. Even though, conversion of COD data to TOC seems to be rather reliable than that of BOD-TOC, further monitoring is recommended to ensure better interpretation of relationship among BOD, COD and TOC.

Research on the Evaluation of Impaired Waterbody using the Flowrate Group at TMDL Unit Watershed in Nakdong River Basin (수질오염총량관리 단위유역 유량그룹별 수체 손상 분석)

  • Hwang, Ha-Sun;Kim, Sang-Soo;Kim, Jin-Lee;Park, Bae-Kyung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.933-942
    • /
    • 2012
  • The purpose of this study is to evaluate the degree of waterbody impairment according to the flow conditions and present to the appropriate water quality improvement alternatives using observed water quality and flow for Total Maximum Daily Load (TMDL) implementation at 39 unit watersheds the nakdong river basin. Observed water quality data for 7 years are divided into five cumulative flow frequency group and comparing the each observed water quality data and TMDL Target water quality (TWQ) the last evaluate the water quality is impaired group. We found that the cumulative flow frequency group-specific the average excess rate of V group was the highest (32.86%), followed by the IV group (26.04%), group III (23.36%), II group (22.67%), I group (20.70%), the degree of impaired waterbody tended to be inversely proportional to the flow rate. Resulted from cumulative flow frequency group of impaired water quality assessment, 13 unit watersheds are impaired from a group IV and group V affected by point sources. Therefore, improvement of sewage discharge and the initial composition of the riparian buffer zone are needed. Nakbon F, Namkang D and Namkang E within 13 unit watersheds are impaired from group II and III affected by non-point sources. Therefore, application of Best Management Practices (BMPs) is needed for these watersheds. Evaluation of impaired waterbody using Cumulative flow frequency group is able to determine the extent of the judgment to TWQ exceeded by the flow conditions and helps proper setting Standard flow and planning pollutant reduction for TMDL.

Improvement of Channel Water Quality Module in SWAT (SWAT 모형의 하도 수질 모듈의 개선)

  • Kim, Nam-Won;Shin, Ah-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.902-909
    • /
    • 2009
  • With various reservoirs, dams and reduction of water velocity in downstream, rivers in Korea often have characteristics of accumulation of pollutants. Therefore, the main focus of water quality modeling in Korea needs to be shifted from DO to algae and organic matter. Moreover the structures of water quality models should be modified to have capability of simulating BOD which is a key factor of total water pollution load management in Korea as laboratory experiment BOD (Bottle $BOD_5$). In the SWAT model which is one of the widely used water quality models in Korea, the channel water quality module is using main algorithm of the QUAL2E model which has limitations in simulating algae, organic matter and Bottle BOD5 etc. To overcome this hindrance, in this study, the improved channel water quality module of the SWAT model (Q-SWAT) was proposed by linking the algorithms of the QUAL-NIER model which was developed based on the QUAL2E model to the SWAT model. The algorithms estimating the increase of internal organic matter by fractionization algal metabolism process and calculating Bottle $BOD_5$ were added and the results of proposed model were compared to those of the original SWAT model. The results of comparison test are showing that more accurate BOD values can be obtained with the Q-SWAT model and it is anticipated that the Q-SWAT model can be used as an effective tool of decision support through the water quality simulation and long term pollution source analysis.

Enhancing the Applicability and Improvement Direction of Integrated Environmental Permit System (통합환경허가시스템의 활용도 제고 및 개선방향)

  • Park, Jae Hong;Shin, Su Jeong;Lee, Dae Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.339-345
    • /
    • 2018
  • The integrated environmental permit system is currently in operation online. It carries out various functions of postmanagement such as the submission of annual reports containing operations management data onto integrated management workplaces, the operation and management of emission facilities and prevention facilities, and the disclosure of information on the integrated permission. On the other hand, the integrated environmental permit system needs to perform various roles in order to stably manage and smoothly perform the permitting work. It is necessary to utilize this system to establish policies by using diverse operations management data onto integrated management workplaces collected in the integrated environmental permit system. This system can also play a role in improving the post-management system and user convenience after the permission review and approval processes. The integrated environmental permit system can be effectively used to set up the BAT-AEL because it collects all of the cross-media data and identifies the overall status of the workplace. In order to establish a post management system after the approval, it is necessary to provide performance management and performance evaluation functions as conditions of the permit after approval. In addition, a variety of support functions should be provided to enable the permission authority and the environmental expert examination agency to facilitate the review of permits. It will be necessary to provide an evaluation system and a proactive diagnostic function to determine whether permission conditions and permit emission standards will change in the future. Also, it is important to adopt an information exchange platform that can be used to collect the status data onto the workplaces; the platform can also be used as an information exchange site for technical working groups (TWG), and for collecting field experts' opinions.

Analyzing Flow Variation and Stratification of Paldang Reservoir Using High-frequency W ater Temperature Data (고빈도 수온 자료를 이용한 팔당호의 성층과 흐름 변화 분석)

  • Ryu, In-Gu;Lee, Bo-Mi;Cho, Yong-Chul;Choi, Hwang-Jeong;Shin, Dong-Seok;Kim, Sang-Hun;Yu, Soon-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.392-404
    • /
    • 2020
  • The focus of this study was to quantify the thermal stratification and analyze the relationship between the stratification structure and the tributaries to understand flow variations in the Paldang Reservoir. The vertical distribution of the temperature and density gradients, and the depth and thickness of the thermocline were quantitatively calculated using a lake physics tool (rLakeAnalyzer) and high-frequency monitoring data. Based on a density gradient of 0.2 kg/㎥/m, the thermocline was formed from mid-May to early-September 2019 and the other periods were weakly stratified or mixed. The thickness of the thermocline was developed until 4.7 m and the depth of the thermocline was formed at a depth of 3 - 6 m at the front of the Paldang Reservoir. During the formation of the thermocline, the Namhangang and Gyeongancheon tributaries with relatively high water temperature (low-density) flowed into the upper layer of the reservoir, and the Bukhangang tributary with low water temperature (high-density) mainly affected the lower layer of the reservoir. This is because the density currents were formed due to the difference in the water temperature of the tributaries. The findings of this study may be used for constructing high-frequency monitoring and quantitative data analyses of reservoirs.