• Title/Summary/Keyword: Total Load

Search Result 2,605, Processing Time 0.031 seconds

A Study on the Implementation Method of Total Water Quality Load Management in Sapkyo Lake Watershed (삽교호수계의 수질총량관리제 시행방안 연구)

  • Yi, Sang-jin;Oh, Hye-jeong;Lee, Eun-hyoung;Jung, Jong-Gwan
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.807-814
    • /
    • 2006
  • Sapkyo Lake Watershed occupies about 19.3% of total area of Chungnam Province, and it is necessary to make a plan of counter-measure for the maintenance of public waterbody sound as well as to ensure water resources due to urbanization and industrialization in this area so densely populated and excessively developed. Conventionally water quality management has been enforced by concentration-based system which is not considered the carrying capacity of receptors, hence there are no proper measures for the prevention of an excessive pollutant load over a waterbody. So even though emission sources abide by the conventional permission regulation, then the quantity of wastewater is increased continuously and encountered water shortage to use finally. Therefore this research focused on the review of introduction of total water quality management system in Sapkyo Lake watershed to maintain public waterbody sound and to ensure water resources. By doing this research in introduction of the system in advance, it can contribute to establish the methodology on systematic water quality management. Also the application of this system in Sapkyo Lake watershed can promote the sustainable development of the area by harmonizing the environment and regional economy ultimately.

Monitoring of Pollutant load from a Subwatershed in the Jooam lake (주암호 유입 소유역 오염부하 모니터링)

  • Yoon, Kwang-Sik;Choi, Soo-Myung;Han, Kuk-Heon;Cho, Jae-Young
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.475-478
    • /
    • 2001
  • Runoff and nutrient concentrations were monitored to identify pollutant load characteristics of a subwatershed in the Jooam lake. Observed concentrations of T-N and T-P were $1.445{\sim}3.980mg/{\ell}\;and\;0{\sim}0.273mg/{\ell}$, respectively. Runoff load of T-N, T-P by single storm occurred June 24th 2001 contributed 55% of T-N and 41% T-P of total pollutant load during study period.

  • PDF

Influence of Crop Load on Bitter pit incidence and Fruit Quality of 'Gamhong'/M.9 Adult Apple Trees (성목기 '감홍'/M.9 사과나무의 착과수준이 고두증상 및 과실품질에 미치는 영향)

  • Kweon, Hun-Joong;Park, Moo-Yong;Song, Yang-Yik;Lee, Dong-Yong;Sagong, Dong-Hoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.3
    • /
    • pp.145-153
    • /
    • 2019
  • BACKGROUND: The 'Gamhong' cultivar, middle season apple with big fruit size and high soluble solid content, has been bred in Korea. However, it was hard to cultivate the cultivar in Korea by serious bitter pit. The relationships between shoot growth, fruit size, and bitter pit may be affected by crop load. This study was conducted for 2 years (7~8 years after planting) to investigate vegetative growth, fruit quality, bitter pit incidence, return bloom, and gross income for optimum crop load of 'Gamhong'/M.9 adult apple tree. METHODS AND RESULTS: The crop load was assigned to 4 different object ranges as follow: 45~64, 65~84, 85~104, and 105~124 fruits per tree. The vegetative growth, average fruit weight, percentage of fruits heavier than 375 g, soluble solid content, and return bloom increased significantly at the crop load range of 45~64 fruits. However, the lowest total gross income per tree may have been caused by the highest bitter pit incidence and the lowest yield per tree in any other crop load range. The total gross income and yield per tree increased significantly at the crop load range of 105~124 fruits and return bloom dropped to 40%, and hence it was possible to occur biennial bearing. It was 85~104 fruits that biennial bearing did not occur and total gross income was as high as the crop load range of 105~124 fruits. Also, the yield of high grade fruits per tree, with fruit weight of 400~499 g and none bitter pit on fruit surface, was highest at the crop load range of 85~104 fruits, compared to other crop load range. CONCLUSION: In considering fruit size, bitter pit incidence, return bloom, and gross income, the optimum crop load range of 'Gamhong'/M.9 adult apple tree in high density orchard was 85~104 fruits per tree.

Load-Transfer Analysis by Considering Coupled Soil Resistance (말뚝-지반 상호작용을 고려한 수정된 하중전이함수법 제안)

  • Seol, Hoon-Il;Jeong, Sang-Seom;Kim, Young-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6C
    • /
    • pp.359-366
    • /
    • 2008
  • The load distribution and deformation of pile subjected to axial loads are evaluated by a load-transfer method. The emphasis is on quantifying the effect of coupled soil resistance that is closely related to the ratio of pile diameter to soil modulus $(D/E_s)$ and the ratio of total shaft resistance against total applied load $(R_s/Q)$, in rock-socketed drilled shafts using the coupled load-transfer method. The proposed analytical method that takes into account the soil coupling effect was developed using a modified Mindlin's point load solution. Through comparisons with field case studies, it was found that the proposed method in the present study estimated reasonable load transfer behavior of pile and coupling effects due to the transfer of shaft shear loading, and thus represents a significant improvement in the prediction of load deflections of drilled shafts.

A Study on Multi Level Load Shedding Control Scheme Strategy for Stabilization of the Korean Power System (국내 전력계통 안정화를 위한 다단계 부하차단 제어전략 수립에 관한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • Korean Power System are operating a load shedding system to prevent voltage instability phenomenon caused by severe line contingencies. In order to apply the load shedding scheme should be selected a location, amount, delay time. Current load shedding system is load shedding amount that has been calculated in the steady-state analysis to load shed the total amount in first level, load shedding amount calculated in advance, it is possible to perform an unnecessary load shedding. In this paper, set a multi-level load shedding control strategy step-by-step selection of load shedding amount for the prevention of excessive load shedding. In addition, through a voltage resilience analysis of the power system by applying motor load ratio and sensitivity parameter to selection the multi level load shedding ratio and delay time. For this reason, to take advantage of the limit data of interchange power, by utilizing interface power flow data to set a multi-level load shedding control strategy for the stabilization of the Korean Power System.

A Stochastic Pplanning Method for Semand-side Management Program based on Load Forecasting with the Volatility of Temperature (온도변동성을 고려한 전력수요예측 기반의 확률론적 수요관리량 추정 방법)

  • Wi, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.852-856
    • /
    • 2015
  • Demand side management (DSM) program has been frequently used for reducing the system peak load because it gives utilities and independent system operator (ISO) a convenient way to control and change amount of electric usage of end-use customer. Planning and operating methods are needed to efficiently manage a DSM program. This paper presents a planning method for DSM program. A planning method for DSM program should include an electric load forecasting, because this is the most important factor in determining how much to reduce electric load. In this paper, load forecasting with the temperature stochastic modeling and the sensitivity to temperature of the electric load is used for improving load forecasting accuracy. The proposed planning method can also estimate the required day, hour and total capacity of DSM program using Monte-Carlo simulation. The results of case studies are presented to show the effectiveness of the proposed planning method.

The Prediction of Energy Consumption by Window Inclination (창의 기울기에 따른 건축물 에너지 소비량 예측)

  • Cho, Sung-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.27-32
    • /
    • 2011
  • Most of domestic building generally don't have fixed shading devices considering of appearance and aesthetic issues. In this study is suggested that tilt window simultaneously has a role of shading and blocking solar radiation. The tilt window thermal performance is investigated by relation ship between inclination and heating cooling road. As comparing vertical window with $5^{\circ}$ and $7^{\circ}$ of tilt window respectively, the heating load is increased by 3.6% and cooling load is reduced by 8.1% on $5^{\circ}$ tilt window and the heating load is increased by 5.3% and cooling load is reduced by 11.5% on $5^{\circ}$ tilt window. Especially, the total load of alternative tilt window is showed the reduction rate 2.6% and3.6% compared of vertical window. Therefore, the tilt window is possible to role of shading of solar radiation and reduction of heating and cooling load.

A Study on Indirect Estimating Methods for Yearly Maximum Cooling Load (연 최대 냉방부하의 간접추정 방법론에 관한 연구)

  • Yang, Moon-Hee
    • IE interfaces
    • /
    • v.16 no.1
    • /
    • pp.16-26
    • /
    • 2003
  • In Korea, cooling power load, which occupies about 20% of peak load in 2000 and fluctuates depending on the popular usage of air conditioning systems, has been recently the focus of the load management. The first work of KEPCO (Korea Electric Power Corporation) to regulate cooling load as low as possible was to estimate its approximate scale and to develop the indirect methods to estimate it from the available time series data for the average hourly loads. However, KEPCO would like to have their methods improved both theoretically and practically. In this paper, we analyze their current indirect methods and detect their faults to design better indirect estimation methods. Under one of the assumptions of "no cooling load in April or May", the linear relationship between basic loads and GDP's, and the normalized seasonal factors of the Winters' multiplicative seasonal model, we provide ten indirect estimation methods in total and suggest the estimated cooling load(1988-1999) based on our various indirect methods.

Design of Drilled Shafts Foundation by LRFD in Incheon Bridge Project (인천대교 민자구간의 대구경 현장타설 말뚝기초의 LRFD 설계 적용 사례)

  • Kim, Jeong-Hwan;Lee, Hyun-Gun;Shin, Hyun-Yang;Youn, Man-Geun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.551-561
    • /
    • 2006
  • Incheon bridge project is to construct total 12km long bridges on the sea consist of 800m span length cable stayed bridge, approach bridge and viaduct bridge based on LRFD design specification. To design pile foundations by RCD of each bridge unit, total 4 number of preliminary full scale pile load tests with Osterberg cell method were carried out on the piles for testing. The test load was planned to more than the expected design ultimate capacity and about 29,000tons maximum load was recorded. From the interpretation of test results, design parameters are evaluated and applied to the design. Preliminary pile load test plan and detailed execution of pile load tests are introduced and summarized. The resistance factors are presented for pile design of Incheon Bridge Project in LRFD considering variation of ground conditions and number of test piles.

  • PDF

A Study on the AE Characteristics of the Carbon Fiber Composite Material (탄소섬유 복합재료의 AE 특성에 관한 연구)

  • 옹장우;이영신;심봉식;지용관;주영상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.105-114
    • /
    • 1989
  • This study was carried out to measure the mechanical properties and the acoustic emission (AE) characteristics of the carbon fiber reinforced composites of several types of the stacking sequence. AE signals were detected during the tensile tests. The number of ringdown counts, total ringdown counts were plotted together with the load-displacement curves. The tensile load-displacement behavior of specimen is compared and discussed based on the measured AE properties in relation to the failure mechanism. With the increase of load, AE signals increased. This showed that failure had being propagated by matrix deformation and cracking, delamination, fiber debonding and breakage. Felicity ratio has been obtained by observation of ;the Kaiser effect according to the variation of load ratio. The reloading tests showed that the felicity ratio decreased obviously when the load ratio or damage increased. These AE characteristics are hopeful to be employed as the criteria to evaluate the failure processes of composites.