• Title/Summary/Keyword: Total Load

Search Result 2,605, Processing Time 0.028 seconds

An Analysis on the Audible Sound Due to Load and Cooling Fan for 154kV Power Transformers (154kV 전력용 변압기의 부하소음 및 냉각팬 소음 분석)

  • Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik;Kim, Gyeong-Tak;Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.298-304
    • /
    • 2010
  • Recently, the audible sound level of power transformer has been reduced due to development of new material and enhancement of manufacturing technology. There is lack of research on the audible sound of winding and cooling fan because the research on reduction of audible sound is concentrated on the core sound. Therefore this paper describes 3 kinds(core, winding and cooling fan) of transformer sound source. Also this paper analyzes the effect of load sound and cooling fan sound on the total transformer sounds. As the results, total sound level of 79dBA class transformer rises 0.2~0.3dB due to effect of load sound and rises 2.1~3.5dB due to effect of cooling fan sound. Also, total sound level of 55dBA class transformer rises 2.3~2.9dB due to effect of load sound and rises 1.9~3.5dB due to effect of cooling fan sound.

Development of Desktop-Based LDC Evaluation System for Effectiveness TMDLs (효과적인 오염총량관리를 위한 데스크탑 기반의 LDC 평가 시스템 개발)

  • Ryu, Jichul;Hwang, Ha-Sun;Lee, Sung-Jun;Kim, Eun Kyoung;Kim, Yong Seok;Kum, Donghyuk;Lim, Kyoung Jae;Jung, Younghun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.4
    • /
    • pp.67-74
    • /
    • 2016
  • Load Duration Curve (LDC) can be used as a method for load management of point and non-point pollution source because the LDC easily assesses the water quality corresponding to hydrological changes in a watershed. Recently, the application of LDC to total pollution load management is a growing interest in Korea. In this regard, A desktop-based LDC assessment system was developed in this study to provide convenience to users in water quality evaluation. The developed system can simply produce the LDC by using streamflow and water quality data involved in its database. Also, The system can quantitatively inform the success or failure of the achievement for a target water quality at monthly scale. Furthermore, seasonal water quality and point/non-point pollution load in a watershed can be estimated by this system. We expect that the developed system will contribute to establish local and national policies regarding water management and total pollution load management because of its advantages such as the pollution tracking investigation and the analysis of water quality and pollution loading amount in an ungauged watershed.

A Study on the Introduction of a Total Pollutant Load Management System in Gwangyang Bay, Korea (광양만 특별관리해역의 연안오염총량관리 도입에 관한 연구)

  • Kim, DoHee;Park, JongSick;Han, KiWon;Cho, HyeonSeo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.899-905
    • /
    • 2022
  • Seawater management via Total Pollutant Load Management System (TPLMS) is crucial because it enables local governments to optimally allocate pollutant loads in order to best reduce pollutant load burden while supporting reasonable development. This study analyzed the feasibility of introducing a TPLMS on Gwangyang Bay, a specially managed sea area. We researched the inflow of pollutants and analyzed the present state of seawater quality in Gwangyang Bay and then discussed our findings and reviewed other specially managed sea area with the Gwangyang Bay Advisory Committee. We conclude that TPLMS on Gwangyang Bay is needed and suggest checking economic feasibility, ef iciency, and conducting continuous monitoring of seawater quality indicators such as chemical oxygen demand (COD), total nitrogen (TN), total phosphorus (TP), heavy metals and polcyclic aromatic hydrocarbons (PAHs) prior to introducing a TPLMS in Gwangyang Bay.

A Study on the Selection of the Total Pollution Load Management at Tributaries by Evaluation of Water Quality Volatility: Case Study for Chungcheongnam-do (수질변동성 평가를 통한 지류총량제 도입 대상유역 선정에 관한 연구: 충청남도를 중심으로)

  • Jeongho Choi;Hongsu Kim;Byunguk Cho;Sanghyun Park;Mukyu Lee;Byeonggu Lee;Uram Kang
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.5
    • /
    • pp.377-389
    • /
    • 2023
  • Chungcheongnam-do has been measuring the flow rate and water quality of streams in the province once a month since 2011 in order to water environment policies. Based on the results, after evaluating the coefficient of variation and the tendency of the water quality trend by using the Mann-Kendall test and Sen's Slope for each stream, the streams subject to priority introduction of Total Pollution Load Management at Tributaries were selected through the Stream Grouping Method. The water quality trend analysis results for 125 streams using the Mann-Kendall test and Sen's Slope were evaluated as streams showing a tendency of deteriorating water quality Biochemical oxygen demand (BOD): 13 streams, Total Phosphorus (T-P): 16 streams). Streams with deteriorating water quality were classified into A-D groups using the Stream Grouping Method. Group A, which has a high flow rate and high water quality, is a stream that requires priority management, and was selected as a stream for introduction of Total Pollution Load Management at Tributaries. There are 7 streams that need to be introduced into the BOD category, and there are 7 streams that need to be introduced into the T-P category. In this study, based on flow and water quality monitoring data accumulated over a long period of time (2011-2022), statistical techniques are used to select watersheds in which water quality is deteriorating. Accordingly, it is expected that it will be useful in establishing a water quality improvement plan in the future.

A Study on the Analysis of the Total Load by the Unit Stream Power (Unit Stream Power에 의한 총유사량해석(總流砂量解析)에 관한 연구(研究))

  • Lee, Won Hwan;Chun, Min Woo;Park, Sang Deog
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.79-92
    • /
    • 1984
  • The analysis of total load was carried out by using the theory of unit stseam power (USP). The dimensionless USP equation of $S_R$ which was the rate of suspended load and bed load was derived from the USP function by applying the Einstein's reference concentration and Stokes' fall velocity. And the R relationship between the water discharge and Reynolds number (Re) was discussed, and it was shown that USP was closely related with Re. The value of $S_R$ was determined from the experimental data of Han River downstream and Mantz. And it was tested to several observatories of Korean Rivers. A good correlation among USP, suspended load and $S_R$ was shown and USP was increased with the increment of the turbulent intensity. Judging from the above results, it is considered this study can be contributed to estimate the total load.

  • PDF

Unit-load Method for the Estimation of Non-point Pollution Loads by Subcategorizing the Land-use Category Reflected in the National Land Register Data : A Case Study of Kyeongan Watershed in South korea (경안천 유역 지적공부에 나타난 특정지목의 토지이용 특성 세분화를 통한 비점오염 부하량 산정 개선방안)

  • Lee, Bum-Yeon;Lee, Chang-Hee;Ha, Do;Lee, Su-Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.598-607
    • /
    • 2010
  • One of constraints in the application of unit-load method to estimate non-point pollution loads in the total water pollutant load management system (TWPLMS) is the limited numbers of applicable unit-loads. Since only 7 unit-loads are currently available for total 28 land-use categories in the national land register data, each unit-loads inevitably have to represent several land-use categories regardless of their actual land coverage characteristics. As a way to minimize the problem, this study suggested a nested application of the available unit-loads based on the analysis of high resolution aerial images taken in the Kyeongan watershed. Statistical analysis of three selected land-use categories such as school, apartment complex, and golf course showed that there exit significant (95% confidence level) relationships between the registered land-uses and actual land coverages. The school and apartment complex currently considered as 100% ground have only 65% and 80% of ground characteristics, respectively. Golf course, which is considered as 100% pasture, has about 5% of ground area. This indicates that the unit-load method using in TWPLMS can give over estimated non-point pollutant loads for the school and apartment complex (19.8~54.4%) but under estimation for the golf course (80.9%).

A Study on Selection Method of Management Watershed for Total Pollution Load Control at Tributary (지류총량관리를 위한 관리유역 선정 방법에 관한 연구)

  • Hwang, Ha Sun;Lee, Sung Jun;Ryu, Jichul;Park, Ji Hyung;Kim, Yong Seok;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.528-536
    • /
    • 2016
  • The purpose of Total Pollution Load Control at Tributary is to obtain maximum improvement effect of water quality through finding the most impaired section of water-body and establishing the proper control measure of pollutant load. This study was implemented to determine the optimal management of reach, period, condition, watershed, and pollution source and propose appropriate reduction practices using the Load duration curve (LDC) and field monitoring data. With the data of measurement, LDC analysis shows that the most impaired condition is reach V (G4~G5), E group (flow exceedance percentile 90~100%) and winter season. For this reason, winter season and low flow condition should be preferentially considered to restore water quality. The result of pollution analysis for the priority reach and period shows that agricultural nonpoint source loads from onion and garlic culture are most polluting. Therefore, it is concluded that agricultural reuse of surface effluent (storm-water runoff with non-point sources) and low impact farming that includes reducing fertilization and controlling the height of drainage outlet are efficient water quality management for this study watershed.

Research on the Applicability of the Load Duration Curve to Evaluate the Achievement of Target Water Quality in the Unit Watershed for a TMDL (수질오염총량 단위유역의 목표수질 달성여부 평가를 위한 부하지속곡선 적용성 연구)

  • Hwang, Ha-Sun;Park, Bae-Kyung;Kim, Yong-Seok;Park, Ki-Jung;Cheon, SeUk;Lee, Sung-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.885-895
    • /
    • 2011
  • The purpose of this study was evaluated on achievement of the Target water quality (TWQ) with Load Duration Curve (LDC) as well as materials collected through the implementation of Total Maximum Daily Load (TMDL), targeting 41 unit watersheds in the Nakdong River Basin in korea, and examines the adequacy of the LDC method to evaluate the TWQ by comparing methods through current regulations. It aims to provide basic materials for TMDL development in Korea. This determination resulted from the fact that the measured data placed on the LDC mean that they are beyond TWQ in a certain condition of water flow when actually measured load values were displayed in a form of LDC. In addition to water quality surveys, it is considered that information on the level of damage in a water body by water flow grade can be utilized as a basic material to identify compliance with the total admitted quantity, and establish rational plans to improve water quality. This information helps in the identification of the degree of damage in water quality according to water flow.

Agent-based Shipment Algorithm for Capacitated Vehicle Routing Problem with Load Balancing (CVRP를 위한 에이전트 기반 Shipment 알고리듬 개발)

  • Oh, Seog-Chan;Yee, Shang-Tae;Kim, Taioun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.3
    • /
    • pp.200-209
    • /
    • 2006
  • Load building is an important step to make the delivery supply chain efficient. We present a family of load makeup algorithms using market based control strategy, named LoadMarket, in order to build efficient loads where each load consists of a certain number of finished products having destinations. LoadMarket adopts Clark-Wright algorithm for generating initial endowment for Load Traders who cooperate to minimize either total travel distance or the variance with respect to the travel distances of loads by means of the spot market or double-sided auction market mechanism. The efficiency of the LoadMarket algorithms is illustrated using simulation based experiments.

Development of Odinary GIS and Database for Calculation of Pollutant Load in Rural Areas (농촌유역의 오염부하량산정을 위한 범용적 GIS 및 데이터베이스의 구축)

  • Yang, Young-Min;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.460-465
    • /
    • 2001
  • Pollutant load using unit load method is calculated by simply equation, especially, very useful in the area that didn't exist about water quality data. However, it takes long time to calculate pollutant load with area in which there is various pollutants and if the boundary of a basin altered, the work of calculation about pollutant load must be begun from the first again. Therefore, a Total Daily Load Program(TDLP) was developed to calculate pollutant load automatically in rural area. The TDLP includes a geographic information system(GIS), relational database system(RDBS), User Interface. This Program can provide user with creating a boundary of the basin that user is concerned with to satisfy the water quality regulations and calculating daily load for various pollutants. The effort was conducted to apply the developed TDLP to calculating pollutant load in rural basin called Bok-ha river.

  • PDF