• 제목/요약/키워드: Total Least Square Method

검색결과 110건 처리시간 0.024초

해외직접구매의 두 요소 : 자기효능감과 구매충동성 (Two Factors of Overseas Online Shopping : Self-Efficacy and Impulsivity)

  • 이한석
    • 유통과학연구
    • /
    • 제16권8호
    • /
    • pp.79-89
    • /
    • 2018
  • Purpose - This research aims to investigate the factors that influence consumer's overseas online shopping behavior. Consumers adopt overseas online shopping as a new buying way and more and more consumers prefer overseas online shopping than traditional shopping ways. Consumers' behaviors in this shopping experience can be different from other shopping experiences. With the increase of overseas online shopping, we need to find antecedents and results of overseas online shopping. Especially there would be positive or negative factors which influence overseas online shopping motivation. To find the relationship, this study examines self-efficacy and impulsivity as major factors which influence overseas online shopping. We also suggest that several attitude factors increase self-efficacy and it is positively related to customer satisfaction. On the other hand, we assume that overseas online shopping factors influence impulsivity of buying and it will decrease customer satisfaction. Research design, data, and methodology - This empirical study data were collected from Korean people who experience overseas online shopping. The subjects for this study were confined to shoppers who used overseas online shopping within the past six months. A total of 267 responses were gathered. SPSS 23.0, PLS 2.0 software were used in the data analysis. Descriptive statistics were used to show sample characteristics. We examined reliability, validity test for constructs. All measurement items used seven-point scales(1= very strong disagree, 7 = very strongly agree) drawn from previously published papers. Partial Least Square method was applied to find the relationship between antecedent factors and dependent factors and hypotheses were estimated. Results - Results show that perceived superiority, perceived ease of use, perceived transaction safety, perceived behavioral control positively affect self-efficacy. Self-efficacy influences positively to consumer's post purchase satisfaction. Perceived monetary benefit and perceived uniqueness motivated impulse buying. This can make consumer's post purchase dissatisfaction. Conclusions - This paper attempted to confirm the existence of both the positive and negative faces of overseas online shopping. The result reveals that self-efficacy is a major factor which may increase satisfaction in the overseas online shopping. Usually, we can think monetary benefit and uniqueness of products motivate overseas online shopping. But it can also intrigue impulse buying and negatively affect customer relationship. Therefore companies should provide enough products information to their potential customers and they might apply adequate processes such as recommendation, comparing systems to build long term relationship with their customers.

동해 해수면의 계절적인 변동에 대하여 (Seasonal sea Level oscillations in the East Sea (Sea of Japan))

  • 오임상;알렉산더 비 라뷔노비치;박명숙;로알드 엔 만수로브
    • 한국해양학회지
    • /
    • 제28권1호
    • /
    • pp.1-16
    • /
    • 1993
  • 해수면의 계절적인 변동성을 조사하기 위하여 한국의 황해, 남해 및 동해안의 조위 관측점과 러시아, 일본의 동해에 연한 총 48개 관측점의 월평균해수면 자료를 분석 하였다. 해수면의 강한 계절적인 변화는 한국 서안의 군산(42.1 cm)과 대한 해협, 그리고 Primorye 지역의 남부 가까이(30-33 cm)에서 기록되었으며, 비교적 약한 변화는 사할린 남서해안에서 발견되었다. 남서 사할린을 제외한 전 연구지역에서 계절적인 해 수면 변동 양상이 거의 같다. 즉 여름과 가을에 상승하고 겨울과 봄에 감소하는 양상 이다. 이들 해수면자료의 스펙트럼 분석의 결과로 계절적인 진동이 해수면의 변위 중 에 가장 우세하며 연구해역의 함부에서는 전체 에너지의 80%에 달하고 북부에서도 50-70%에 달했다. 또, 대부분의 관측점에서 연주기 성분이 현저히 우세하며, 반년주기 성분도 명백히 나타났으나 그 이상의 고주파 성분은 단지 몇몇 관측점에서만 보일 정도이었다. 최소자승법을 사용하여 계산한 년수기 성분(A1)의 최대 진촉은 한국의 서안에서 20-21cm에 달하였다. 발년주기 성분은 사할린섬의 남단과 남서 해안에서 최대치 3-4cm인 것으로 밝혀졌다. 이지역의 년주기 해수면 변동폭은 여타지역보다 훨씬 작아서 전 에너지 수지에 대한 계절적 변도의 상대적 크기는 단지 35-40%에 지나지 않으며, 년수기와 발년주기의 진폭비(계절변동 계수 R=A1+A2)는 0.9-1.2로서 같은 크기임을 알수 있다. 이와 같은 해수면 자료의 분석과 Tomizawa et al.(1984)의 연구결과를 근거로하여 본 연구해역을 10개의 해역으로 나눌수 있다. 즉 황해와 한국의 남해 서부해안을 Y1과 Y2해역으로 동해를E1에서 E8까지 8개의 해역으로 나눌수 있다.

  • PDF

가시광선-근적외선 분광법을 이용한 유성분 측정 기술 개발 (Development of Measuring Technique for Milk Composition by Using Visible-Near Infrared Spectroscopy)

  • 최창현;윤현웅;김용주
    • 한국식품저장유통학회지
    • /
    • 제19권1호
    • /
    • pp.95-103
    • /
    • 2012
  • 본 연구는 원유의 실시간 휴대용품질측정 시스템 개발을 위한 기초 연구로서 원유 시료의 온도에 따른 가시광선-근적외선 스펙트럼을 측정하였으며, 다양한 수학적 전처리방법을 적용하여 유성분 예측모델을 개발하였다. 스펙트럼 측정은 원유 시료 180개에 대해 스펙트럼의 수학적 전처리 방법으로 평활화, 정규화, MSC, 1차 및 2차 미분을 사용하였고 예측모델은 부분최소자승법을 이용하였다. 유성분을 분석한 결과 함량 범위와 평균은 지방이 각각 2.44~6.42%, 4.05%, 단백질은 각각 2.44~4.28%, 3.35%, 무지고형분은 각각 7.85~9.57%, 8.76%로 나타났다. 또한 유당의 함량 범위와 평균은 각각 3.93~5.24%, 4.74%였으며 요소태질소의 경우에는 각각 4.6~15.1 mg/dl, 10.27 mg/dl로 대부분 권장 기준을 만족하였다. 원유 시료의 온도에 따른 스펙트럼은 1,400~2,500 nm에서 큰 차이를 보였으며 온도가 상승함에 따라 흡광도가 높아지는 것을 알 수 있었다. 원유 시료의 온도에 따른 유성분 예측모델을 400~2,500 nm의 영역에서 개발하였으며 예측성능은 지방과 무지고형분의 경우 온도변화와 무관하였다. 단백질과 유당, 요소태질소의 예측성능은 온도가 낮을수록 급격히 감소하여 스펙트럼 측정 시 원유 시료의 온도를 $40^{\circ}C$로 유지하는 것이 필요함을 알 수 있다. $40^{\circ}C$의 원유 스펙트럼에 대해 수학적 전처리를 수행한 결과 평활화를 수행하여 측정 장치 자체의 노이즈를 감소시킬 수 있었고 정규화를 수행하여 기준선을 일치시킬 수 있었다. 또한 MSC를 수행하여 빛의 산란에 의한 영향을 제거하여 스펙트럼간의 차이를 감소시킬 수 있었고 1차 및 2차 미분을 수행한 결과 기준선 일치와 기존 스펙트럼에서 나타나지 않았던 파장영역에 대한 분석이 가능함을 알수 있다. 다중회귀분석의 stepwise 방법을 이용하여 최적 파장영역을 선정하고 유성분 예측모델을 개발한 결과 요소태질소를 제외하고 대부분 근적외선 영역에서 우수한 상관관계를 보여주었다. 지방과 단백질은 원시 스펙트럼의 검증부 결정계수가 각각 0.93, 0.92에서 정규화를 수행한 결과 각각 0.98, 0.92로 원시 스펙트럼의 결과가 우수하여 큰 개선이 없었으나 RPD는 각각 4.10, 3.41에서 5.47, 3.73으로 높아져 정밀도가 향상됨을 알 수 있다. 무지고형분과 유당의 예측모델은 원시 스펙트럼의 경우 각각 0.82, 0.75로 예측모델로 사용하기에는 어려웠으나 각각 평활화와 MSC를 수행하였을 때 검증부 결정계수가 0.90, 0.80으로 크게 개선되어 유성분 예측모델의 신뢰성 향상에 기여할 수 있을 것으로 판단된다. 요소태질소의 경우 가시광선 영역에서 가장 우수한 상관관계를 보여주었으나 검증부 결정계수, 오차, RPD가 각각 0.61, 1.56%, 1.58로 다른 성분에 비해 매우 낮게 나타났다. 이를 개선하기 위해 수학적 전처리를 수행하였으나 크게 개선되지 않았으므로 요소태질소의 신뢰성 있는 모델을 개발하기 위해서는 부분최소자승법 외에 다양한 알고리즘의 적용이 필요할 것으로 판단된다.

벼 무경운 재배시 재배양식에 따른 생육 및 수량 (Rice Growth and Yield at Different Cultural Methods under No-tillage Condition)

  • 박홍규;김상수;백남현;석순종;박건호;이선용
    • 한국작물학회지
    • /
    • 제41권4호
    • /
    • pp.420-428
    • /
    • 1996
  • 획기적인 벼 생산비 절감 기술 확립을 위해1993~1995년 호남농업시험장인 전북통(미사질양토)에서 동진벼를 공시하고 무경운 기계이앙, 무경운 무논골뿌림, 무경운 표면조파, 무경운 산파, 경운 기계이앙 등 5가지로 하여 재배 양식간의 생육 및 수량성의 차이를 비교 검토한 결과는 다음과 같다. 1. 토양 경도는 무경운에서 높았고(토심 10cm의 경도 : 무경운 1.6kg/$cm^2$, 경운 1.0kg/$cm^2$), 토괴 심도가 깊을수록 경운과의 차이가 커지는 경향이었으며, 토양 물리성중 가비중은 무경운이 경운보다 높았으며 공극률은 경운에서 58.5~55.9로 무경운의 52.1~50.5보다 높았다. 2. 무경운 직파재배시 m$^2$당 입모수는 l13~133개였으며 이앙재배시 결주율은 경운 이앙 3%, 무경운 이앙 4.5%로 무경운 이앙에서 높았고, 유효경 비율은 경운 이앙이 높았으며, 무경운 재배 양식간에는 이앙>무논골뿌림>표면조파>산파의 순으로 높았다. 3. 잡초 발생량은 무경운에서 많았으며 경운에서는 피, 올양개, 방동사니가 우점하였고 무경운에서는 나도겨풀, 사마귀풀, 둑새풀이 우점하였 다. 4. 뿌리량은 경운 이앙에서 가장 많았고, 무경운재배 양식간에는 이앙>무논골뿌림>표면조파>산파의 순으로 많았으며, 뿌리 분포는 무경운에서 경운보다 표층 분포가 많았다. 특히 표면에 파종한 산파와 표면조파에서 표층 분포가많았다. 5. 하위 절간의 분포 비율은 도복이 심했던 무경운 표면조파와 산파에서 낮았고, 무경운 무논골뿌림, 무경운 이앙은 경운 이앙과 비슷하였으며, 중심고는 이앙재배에 비해 직파재배에서낮았고 줄기 매몰 심도는 경운(3.1cm)에 비해 무경운에서 낮았는데 무경운 표면조파, 산파에서는 0.6~0.7cm로 현저히 낮았다. 6. 도장 도복은 무경운재배시 산파>표면조파>무논골뿌림>이앙재배 순으로 높게 발생했으며, 특히 무경운 표면조파와 산파에서 뿌리도복이 심하게 발생되었다. 7. m$^2$당 수수는 경운 이아이 가장 많았고 무경운산파가 가장 적었으며, 등숙 비율은 포장도복이 심했던 무경운 표면조파, 산파에서 가장 낮았다. 벼 수량성은 경운, 무경운 이앙은 서로 비슷하였고 무경운 무논골뿌림은 경운 이앙의 약 93%였으며, 무경운 표면조파, 산파는 포장도복으로 크게 낮아 경운 이질의 87~81%정도였다.

  • PDF

상자성 복합체의 분자량에 따른 T1 및 T2 자기이완시간에 관한 연구 (The Molecular Weight Dependance of Paramagnetic Gd-chelates on T1 and T2 Relaxation Times)

  • 김인성;이영주;김주현;;김숙경;김태정;강덕식;장용민
    • 한국의학물리학회지:의학물리
    • /
    • 제17권2호
    • /
    • pp.61-66
    • /
    • 2006
  • 상자성 복합체의 분자량에 따른 물분자의 T1 및 T2 자기이완 특성을 조사해 보고자 하였다. DMF (15 ml)와 DTPA-bis-anhydride (0.71 g, 2 mmol) 용액에 4-aminomethylcyclohexane carboxyilc acid를 넣어 리간드를 합성한 후 $Gd_2O_3$ (0.18g, 0.5 mmol)을 넣어 최종적인 Gd 착화물을 합성하였다. 상자성 복합체의 자기이완율을 측정하기 위해 상자성 복합체를 3차 증류수를 사용하여 1 mM로 희석시켰으며 1.5T(64 MHz)에서 자기이완 시간을 측정하였다. T1 자기이완시간을 측정하기 위하여 반전 회복(Inversion-recovery) 펄스열을 사용하였다. 반전 회복 펄스열의 경우 반전시간(Inversion time, T1)은 50 msec에서부터 최대 1,750 msec까지 총 35개의 반전시간에서 영상을 획득하였다. T2 자기이완시간은 CPMG(Carr-Purcell-Meiboon-Gill) 펄스열을 사용하였다. 자기이완 시간을 구하기 위해 각각의 샘플에 관심영역(region of Interest)을 설정하여 영상의 신호강도를 측정한 후 비선형 곡선 맞춤을 실행하여 T1 및 T2값을 얻어낸 후, 이를 통해서 R1 및 R2를 계산하였다. 분자량이 587 달톤인 Omniscan의 1.5T에서의 T1, T2값이($205.1{\pm}2.57$) msec, ($209.4{\pm}4.28$) msec 임에 비해 새로이 합성된 상자성 Gd 화합물의 경우 모두 T1, T2값이 T1의 경우 분자량에 따라 $(96.35{\pm}2.04)-(79.38{\pm}1.55)$ msec, T2의 경우 $(91.02{\pm}2.08)-(76.66{\pm}1.84)$ msec로 감소한 결과를 얻었다. 새로이 합성된 Gd 화합물 간에도 분자량에 따라 R1 및 R2값이 증가하는 경향을 나타내었다. 상자성 복합체의 분자량이 증가함에 따라 T1 및 T2 자기이완 시간이 단축되고 결과적으로 자기이완율 R1, R2가 분자량에 비례하여 증가하였다.

  • PDF

근적외 분광분석법을 이용한 국내 유통 식품 함유 탄수화물, 단백질 및 지방의 정량 분석 (Quantitative Analysis of Carbohydrate, Protein, and Oil Contents of Korean Foods Using Near-Infrared Reflectance Spectroscopy)

  • 송이슬;김영학;김기쁨;안경근;황영선;강인규;윤성원;이준수;신기용;이우영;조영숙;정명근
    • 한국식품영양과학회지
    • /
    • 제43권3호
    • /
    • pp.425-430
    • /
    • 2014
  • 식품의 3대 영양소인 탄수화물, 단백질 및 지방의 일반적인 분석 방법은 Kjeldahl 및 Soxhlet 시험법과 같은 기존의 화학 분석 방법으로 분석하였다. 그러나 이러한 분석 방법은 시료의 전처리 과정이 필요하고 많은 비용과 분석 시간이 소모되며 복잡한 추출과정을 거친다는 단점이 있다. 따라서 본 연구에서는 국내 유통 식품 및 농산물 자원에 함유된 탄수화물, 단백질 및 지방의 함량을 근적외 분광분석법(near-infrared reflectance spectroscopy, NIRS)으로 신속하고 정확하게 동시에 측정할 수 있는 방법을 검토하였다. 분석시료는 517종의 다양한 식품 시료를 예측모델 개발용(calibration set) 412종과 예견치 분석용(validation set) 162종으로 구분하여 사용하였다. 기존의 화학 분석 방법에 의해 측정된 성분들의 분석 결과와 근적외 스펙트럼 데이터간의 상관관계를 조사하여 각 성분별 예측모델을 검토하였으며, 변형부분최소자승법(MPLS) 및 다양한 수처리와 산란보정을 이용한 결과, 탄수화물, 단백질 및 지방의 산란방식은 각각 weighted MSC, standard MSC 및 SNV only로 수처리는 각각 1차 미분(1st derivative, 4 nm gap, 5 points smoothing, 1 point second smoothing), 2차 미분(2, 5, 5, 3) 및 1차 미분(1, 1, 1, 1)을 적용하여 예측모델을 검토한 결과 $R^2$값이 0.971, 0.974 및 0.937로 높고 SEC값은 4.066, 1.080 및 1.890으로 낮은 최적의 예측모델을 개발하였다. 세 성분의 최적 예측모델에 의한 상관도와 잔차 히스토그램을 검토한 결과 세 성분 모두 근적외 분광분석법 예측모델로 적합함을 확인할 수 있었으며, 최적의 예측모델을 미지의 식품 시료 162종에 적용한 결과, 탄수화물, 단백질 및 지방의 $r^2$(SEP)값은 0.987(2.515), 0.970(1.144) 및 0.947(1.370)로 $r^2$값은 높으며 SEP값은 낮은 양호한 양상을 나타내었다. 그러나 지방의 결정계수($R^2$, $r^2$)값은 탄수화물, 단백질에 비해 다소 낮은 양상을 나타내므로 추후 식품 검체에 적용 시 탄수화물 및 단백질 성분에 비해 예측결과의 정확성이 다소 낮을 수 있다고 판단되어진다. 이상의 결과에서 전처리 단계에서 복잡한 추출과정, 많은 비용소모, 분석시간 및 고도의 분석기술을 요하는 기존 습식 화학분석 방법의 단점을 보완하고자 검토되었던 근적외 분광분석법은 다량의 식품분석 시료를 분석하기에는 매우 효율적이라고 생각되며, 이런 점들을 고려해 보면 근적외 분광분석 예측모델들은 추후에 미지 식품시료에 함유된 탄수화물, 단백질 및 지방의 기존 분석법을 대체하여 편리하고 빠르게 함량을 예측 가능할 것으로 판단된다.

노천굴착에서 발파진동의 크기를 감량 시키기 위한 정밀파실험식 (On the vibration influence to the running power plant facilities when the foundation excavated of the cautious blasting works.)

  • 허진
    • 화약ㆍ발파
    • /
    • 제9권1호
    • /
    • pp.3-13
    • /
    • 1991
  • 발파에 의한 지반진동의 크기는 화약류의 종류에 따른 화약의 특성, 장약량, 기폭방법, 전새의 상태와 화약의 장전밀도, 자유면의 수, 폭원과 측간의 거리 및 지질조건 등에 따라 다르지만 지질 및 발파조건이 동일한 경우 특히 측점으로부터 발파지점 까지의 거리와 지발당 최대장약량 (W)간에 깊은 함수관계가 있음이 밝혀졌다. 즉 발파진동식은 $V=K{\cdot}(\frac{D}{W^b})^n{\;}{\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots}$ (1) 여기서 V ; 진동속도, cm /sec D ; 폭원으로부터의 거리, m W ; 지발 장약량, kg K ; 발파진동 상수 b ; 장약지수 R ; 감쇠지수 이 발파진동식에서 b=1/2인 경우 즉 $D{\;}/{\;}\sqrt{W}$를 자승근 환산거리(Root scaled distance), $b=\frac{1}{3}$인 경우 즉 $D{\;}/{\;}\sqrt[3]{W}$를 입방근환산거리(Cube root scaled distance)라 한다. 이 장약 및 감쇠지수와 발파진동 상수를 구하기 위하여 임의거리와 장약량에 대한 진동치를 측정, 중회귀분석(Multiple regressional analysis)에 의해 일반식을 유도하고 Root scaling과 Cube root scaling에 대한 회귀선(regression line)을 구하여 회귀선에 대한 적합도가 높은 쪽을 택하여 비교, 검토하였다. 위 (1)식의 양변에 log를 취하여 linear form(직선형)으로 바꾸어 쓰면 (2)式과 같다. log V=A+BlogD+ClogW ----- (2) 여기서, A=log K B=-n C=bn (2)식은 다시 (3)식으로 표시할 수 있다. $Yi=A+BXi_{1}+CXi_{2}+{\varepsilon}i{\;}{\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots}$(3) 여기서, $Xi_{1},{\;}Xi_{2} ;(두 독립변수 logD, logW의 i번째 측정치. Yi ; ($Xi_1,{\;}Xi_2$)에 대한 logV의 측정치 ${\varepsilon}i$ ; error term 이다. (3)식에서 n개의 자료를 (2)식의 회귀평면으로 대표시키기 위해서는 $S={\sum}^n_{i=1}\{Yi-(A+BXi_{1}+CXi_{2})\}\^2$을 최소로하는 A, B, C 값을 구하면 된다. 이 방법을 최소자승법이 라 하며 S를 최소로 하는 A, B, C의 값은 (4)식으로 표시한다. $\frac{{\partial}S}{{\partial}A}=0,{\;}\frac{{\partial}S}{{\partial}B}=0,{\;}\frac{{\partial}S}{{\partial}C}=0{\;}{\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots}$ (4) 위식을 Matrix form으로 간단히 나타내면 식(5)와 같다. [equation omitted] (5) 자료가 많아 계산과정이 복잡해져서 본실험의 정자료들은 전산기를 사용하여 처리하였다. root scaling과 Cube root scaling의 경우 각각 $logV=A+B(logD-\frac{1}{2}W){\;}logV=A+B(logD-\frac{1}{3}W){\;}\}{\;}{\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots}$ (6) 으로 (2)식의 특별한 형태이며 log-log 좌표에서 직선으로 표시되고 이때 A는 절편, B는 기울기를 나타낸다. $\bullet$ 측정치의 검토 본 자료의 특성을 비교, 검토하기 위하여 지금까지 발표된 국내의 몇몇 자료를 보면 다음과 같다. 물론, 장약량, 폭원으로 부터의 거리등이 상이하지만 대체적인 경향성을 추정하는데 참고할수 있을 것이다. 금반 총실측자료는 총 88개이지만 환산거리(5.D)와 진동속도의 크기와의 관계에서 차이를 보이고 있어 편선상 폭원과 측점지점간의 거리에 따라 l00m말만인 A지역과 l00m이상인B지역으로 구분하였다. 한편 A지역의 자료 56개중, 상하로 편차가 큰 19개를 제외한 37개자료와 B지역의 29개중 2개를 낙외한 27개(88개 자료중 거리표시가 안된 12월 1일의 자료3개는 원래부터 제외)의 자료를 computer로 처리하여 얻은 발파진동식은 다음과 같다. $V=41(D{\;}/{\;}\sqrt[3]{W})^{-1.41}{\;}{\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots}$ (7) (-100m)(R=0.69) $V=124(D{\;}/{\;}\sqrt[3]{W})^{-1.66){\;}{\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots\cdots}$ (8) (+100m)(R=0.782) 식(7) 및 (8)에서 R은 구한 직선식의 적합도를 나타내는 상관계수로 R=1인때는 모든 측정자료가 하나의 직선상에 표시됨을 의미하며 그 값이 낮을수록 자료가 분산됨을 뜻한다. 본 보고에서는 상관계수가 자승근거리때 보다는 입방근일때가 더 높기 때문에 발파진동식을 입방근($D{\;}/{\;}\sqrt[3]{W}$)으로 표시하였다. 특히 A지역에서는 R=0.69인데 비하여 폭원과 측점지점간의 거리가 l00m 이상으로 A지역보다 멀리 떨어진 B지역에서는 R=0.782로 비교적 높은 값을 보이는 것은 진동성분중 고주파성분의 상당량이 감쇠를 당하기 때문으로 생각된다.

  • PDF

인터넷쇼핑몰의 VMD 구성요인에 대한 탐색적 연구 (An Exploratory Study on the Components of Visual Merchandising of Internet Shopping Mall)

  • 김광석;신종국;구동모
    • 마케팅과학연구
    • /
    • 제18권2호
    • /
    • pp.19-45
    • /
    • 2008
  • 본 연구는 인터넷쇼핑몰 비주얼 머천다이징의 주요차원을 고객이 쇼핑몰에 진입한 후 정보탐색과 대안평가를 거치는 등의 쇼핑과정을 토대로 AIDA모형 관점에서 점포, 제품, 촉진에 초점을 맞추었다. VMD의 주요차원(primary dimensions)으로는 점포디자인, 머천다이징, 그리고 머천다이징단서로 구분하였다. 선행연구 결과를 토대로 점포다자인의 하위차원으로는 차별성, 간결성, 위치확인성을, 머천다이즈의 하위차원으로는 제품구색, 명성, 정보성을, 그리고 머천다이징단서의 하위차원으로는 제품추천 및 링크를 설정하여 VMD태도와의 관계를 탐색적으로 조사하였다. 연구결과 이들 세 차원은 종속변수에 유의한 정의 영향을 미치는 것으로 나타났다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF