• 제목/요약/키워드: Total Harmonic Distortion(THD)

검색결과 259건 처리시간 0.028초

The Evaluation of Medium Voltage Motor's Current and Voltage Harmonics during Loading

  • Alboyaci, Bora;Yorukeren, Nuran
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.35-41
    • /
    • 2007
  • This paper presents the results of investigating harmonic levels on medium voltage motors at loading conditions in air separation plant. The essential results of the measurements of the medium voltage motor harmonics are summarized in the values for the total harmonic distortion (THD). Motors loading case is used to assess the current and voltage harmonic distortions. Proper system analysis is important when adding a new motor starting and controlling the equipment. With the result of the paper it is possible to suggest the most appropriate starting and control method. Two medium voltage motors of air separation unit measurement results and simulations are summarized. Both current and voltage harmonic distortions are fitted by using a linear and exponential regression model. The prediction of THD values can be used for this kind of process for future planning by utilities.

A Power Regulation and Harmonic Current Elimination Approach for Parallel Multi-Inverter Supplying IPT Systems

  • Mai, Ruikun;Li, Yong;Lu, Liwen;He, Zhengyou
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1245-1255
    • /
    • 2016
  • The single resonant inverter is widely employed in typical inductive power transfer (IPT) systems to generate a high-frequency current in the primary side. However, the power capacity of a single resonant inverter is limited by the constraints of power electronic devices and the relevant cost. Consequently, IPT systems fail to meet high-power application requirements, such as those in rail applications. Total harmonic distortion (THD) may also violate the standard electromagnetic interference requirements with phase shift control under light load conditions. A power regulation approach with selective harmonic elimination is proposed on the basis of a parallel multi-inverter to upgrade the power levels of IPT systems and suppress THD under light load conditions by changing the output voltage pulse width and phase shift angle among parallel multi-inverters. The validity of the proposed control approach is verified by using a 1,412.3 W prototype system, which achieves a maximum transfer efficiency of 90.602%. Output power levels can be dramatically improved with the same semiconductor capacity, and distortion can be effectively suppressed under various load conditions.

전기추진선박의 토크 및 속도변화에 따른 전력변환장치의 고조파 분석 (Harmonic Analysis of Power Conversion System for Torque and Speed Changing of Electric Propulsion Ship)

  • 김종수;김성환
    • 해양환경안전학회지
    • /
    • 제17권1호
    • /
    • pp.83-88
    • /
    • 2011
  • 근래에 전기추진선박의 필요성이 대두되고 있으며 특수선박을 시작으로 건조가 증가되고 있는 실정이다. 하지만 선박은 운항 환경에 따라 추진기의 출력 토크 및 속도의 변동이 심하므로 전기추진시스템에 큰 영향을 미친다. 대표적으로 출 입항시, 정상상태의 대양 항해시, 황천 항해시에 선박 추진시스템의 토크 및 속도 변동이 짧지만 빈번하게 변동하게 되므로 전기추진시스템의 전력변환장치에서 전류 및 전압파형에 고조파가 크게 포함되어 발전기, 변압기, 컨버터, 인버터 및 추진전동기에 손실의 증가, 기기의 열화 및 토크 맥동 발생 등의 좋지 않은 영향을 미치게 된다. 본 연구에서는 선박의 운항 환경에 따른 추진시스템의 전류 및 전압파형에 포함되는 고조파 함유율을 분석하였다. 분석 결과 저속 영역에서의 잦은 속도 및 부하 변동에 따라서 전동기에 공급되는 전류 및 전압 파형에 포함된 총 고조파 왜형율과 전동기의 토크 맥동이 증가됨을 확인할 수 있었다.

Multilevel Inverters Power Topologies and Voltage Quality: A Literature Review

  • Rehaoulia, Abir;Rehaoulia, Habib;Fnaiech, Farhat
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.83-93
    • /
    • 2016
  • Due to their performances and inherent benefits, especially in medium-voltage and high-power applications, multilevel inverters have received an increasing attention in real world industrial applications. The present paper deals with a review of the main multilevel inverter topologies as well their most common derived and hybrid structures quoted in previous research works. It also encompasses an investigation on voltage harmonic elimination and THD estimation. For that reason, the paper summarizes the most relevant modulation techniques used so far to enhance the output voltage quality. Theoretical formulas evoked in the literature, for calculating the output voltage THD upper and lower bounds are reported and verified by adequate simulations.

풍력 유도발전기의 여자 축전지에 따른 고주파 증폭에 관한 기술 동향 (Technical Trend on Excitation Capacitors on Harmonic Amplification of Wind Induction Generator)

  • 노상필;박정석;이영길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1976-1977
    • /
    • 2007
  • This paper introduce the electrical quantities of a three-phase-connected wind induction generator (WIG) under sudden connection of static loads. An intelligent power-system recorder/monitor is employed to measure threephase voltages and currents of the studied system at WIG's terminals and load's terminals for 5 minutes. A laboratory 300 W wound-rotor induction machine driven by a blushless DC motor is utilized as the studied WIG. Since the generated harmonic currents are randomly varied, total harmonic distortion (THD) of current using cumulative probability density function is employed to determine the penetration of harmonic distortion. The results show that the harmonic currents generated by the studied WIG may be severely amplified to a high level by the connected self-excited capacitance at the stator's terminals.

  • PDF

LC 병렬공진을 이용한 고효율 장수명 LED 구동회로 설계 (The Design of Long-life and High-efficiency Passive LED Drivers using LC Parallel Resonance)

  • 이은수;최보환;천준필;김봉철;임춘택
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.397-402
    • /
    • 2013
  • This paper proposes a new passive type LED driver which satisfies the standard of power factor (PF) and total harmonic distortion (THD). The proposed passive LED driver also has high-efficiency and long-life time characteristics compared to active LED driver which is composed of op-amp, switches and so on. By using just passive components such as inductor, capacitor, and diode, it has resolved extremely short-life time and low-efficiency problems of previous LED drivers. It has achieved PF of 0.99, THD of 16.4 %, and the total efficiency of 95 %. The proposed passive LED driver is fully analyzed and verified by simulations and experiments, which results are in good agreement each other.

한국형 고속열차 주행에 따른 전철변전소 전력공급 상태에 관한 연구 (A Study on the Power Supply Condition in the Railway Substation with Operating HSR350x)

  • 임용찬;이태형;한영재;박춘수;김기환;신명철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.495-498
    • /
    • 2008
  • PCC(Point of Common Coupling) is measured by waveform in power system. Analyzing their frequency, it is possible to get various indices such as THD(Total Harmonic Distortion), TDD(Total Demand Distortion), and VF(Voltage Flicker), and then the harmonic can be evaluated from them. In this paper, the harmonic effect on the power supply which is generated by the vehicle is presented by comparing harmonics with the substation and the vehicle.

  • PDF

Chopper 방식을 이용한 형광등의 집단조광제어 시스템 개발 (Dimming Control System for Multi-Fluorescent Lamp Using Chopper Technique)

  • 전경준;임병노;박종연
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1584-1588
    • /
    • 2007
  • This paper proposed the voltage compulsion method that used chopper for light dimming control of fluorescent lamp. During the dimming period, electronic ballasts have the bad characteristics such as low power factor, high THD(Total Harmonic Distortion) and etc. The proposed dimmer improves power factor, THD of electronic ballast and has benefit such as low cost, simple build up.

FPGA Implementation of Diode Clamped Multilevel Inverter for Speed Control of Induction Motor

  • Kuppuswamy, C.L.;Raghavendiran, T.A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.362-371
    • /
    • 2018
  • This work proposes FPGA implementation of Carrier Disposition PWM for closed loop seven level diode clamped multilevel inverter in speed control of induction motor. VLSI architecture for carrier Disposition have been introduced through which PWM signals are fed to the neutral point seven level diode clamped multilevel using which the speed of the induction motor is controlled. This proposed VLSI architecture makes the power circuit to work better with reduced stresses across the switches and a very low voltage and current total harmonic distortion (THD). The output voltages, currents, torque & speed characteristics for seven level neutral point diode clamped multilevel inverter for AC drive was studied. It has observed the proposed scheme introduces less distortion and harmonics. The results were validated using real time results.

배전 시스템의 고조파 분석 및 모델링에 관한 연구 (A Study on Harmonics Analysis and Modelling for Distribution System)

  • 왕용필;정종원;정동일
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.62-68
    • /
    • 2007
  • 최근 전력 전자 응용 기기의 사용증가로 비선형 특성 부하에 의한 고조파가 상당히 발생하고 있으며, 이에 의한 영향으로 배전시스템의 변압기 열화, 소자의 고장, 통신 간섭 등의 여러 가지 문제를 발생시키고 있다. 따라서 배전 시스템에서의 고조파 수준과 전달특성을 정확하게 분석하기 위하여 배전시스템의 효과적인 실측정과 모델링에 관한 연구가 필요한 실정이다. 본 논문에서는 고조파 관리기준 IEC61000-3-6 토대로 배전 시스템의 고조파 특성을 해석하기 위하여 공통 결합점(Point of Common Coupling : PCC)을 선택하였다. 실 배전 시스템의 PCC 지점에서 고조파 전압, 전류를 측정하여, 고조파 분포, 비선형 부하 성분 및 고조파 전압, 전류 왜형률 (Voltage/Current Total Harmonic Distortion: VTHD/ITHD)을 분석하였다. 또한 정상상태에서 고조파 임피던스, 전압, 전류을 해석을 통하여 실 배전시스템을 효과적이고 정확하게 모델링 되었을 확인하였다. 또한 고조파 전류원 발생시에 고조파 전압, 전류를 비교 분석하여 고조파 전달특성을 조사하였다.