• Title/Summary/Keyword: Total Energy Consumption

Search Result 992, Processing Time 0.028 seconds

A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans (아파트 단위세대 평면 형태에 따른 건물에너지효율 평가)

  • Kim, Chang Sung;Seo, Kyung Wook
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.

A Study of applying VAV and VWV System to reduce Energy Consumption of Office building (VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구)

  • Song, Ji-Yong;Hong, Won-Hwa;Kim, Ji-Yeon;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.

The Influence of Unit Plan Shapes to the Energy Efficiency of Collective Housing Simulated by ECO2 Software (ECO2 프로그램을 이용한 공동주택의 단위세대 평면 형태에 따른 에너지 효율 평가)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: Various policies to reduce the energy consumption have been carried out to save Earth environment against global warming and environmental pollution in many countries. Energy consumption of buildings in Korea has reached 24% of total energy consumption, and energy consumption of apartment has been continuously increasing. Therefore, Korea government has executed building energy efficiency rating certification system to control energy consumption of buildings. Method: This study was conducted to evaluate the energy performance of apartment unit plans according to the increasement of front width of unit plans, and tried to present the basic data to design more energy conscious unit plans for apartments. For the study, three shapes of unit plans -the 2Bay, 3Bay and 4bay unit- were selected for imput models. They were simulated using ECO2 software to assess building energy efficiency rating certification in Korea. Result: According to the results, in cases that balcony windows were not installed, the primary energy consumption of the 3Bay and 4Bay units were less than 2Bay unit, respectively, 0.1% and 2,5%. The primary energy consumption of the 3Bay and 4Bay units, in cases that balcony windows were installed, was less than 2Bay unit, respectively, 1.7% and 3.2%.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Decomposition of Direct and Indirect Energy Consumption Growth in Korea from 1990 to 2000 (한국 가정부문 직간접 에너지소비의 증가요인 분석: 1990~2000)

  • Park, Hi-Chun
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.531-553
    • /
    • 2006
  • As energy conservation can be realized through changes in the composition of goods and services consumed, there is a need to assess indirect and total household energy requirements. The Korean household sector was responsible for about 55% of the country's primary energy requirement in the period from 1990 to 2000. And more than 60% of household energy requirement was indirect. Thus, indirect and total rather than direct household energy requirements should be the target of energy conservation policies. Increases in household consumption expenditure were responsible for a relatively high growth of energy consumption. Switching to consumption of less energy intensive products and decrease in energy intensities of products contributed substantially to reduce the increase in total household energy requirement.

  • PDF

An Energy Saving Method Using Cluster Group Model in Wireless Sensor Networks (무선 센서 네트워크에서 클러스터 그룹 모델을 이용한 에너지 절약 방안)

  • Kim, Jin-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4991-4996
    • /
    • 2010
  • Clustering method in wireless sensor network is the technique that forms the cluster to aggregate the data and transmit them at the same time that they can use the energy efficiently. Even though cluster group model is based on clustering, it differs from previous method that reducing the total energy consumption by separating energy overload to cluster group head and cluster head. In this thesis, I calculate the optimal cluster group number and cluster number in this kind of cluster group model according to threshold of energy consumption model. By using that I can minimize the total energy consumption in sensor network and maximize the network lifetime. I also show that proposed cluster group model is better than previous clustering method at the point of network energy efficiency.

Study on the elements affecting energy consumption of general hospitals in Korea (국내 종합병원의 에너지 사용량에 영향을 미치는 요인 도출)

  • Jeong, Dawoon;Kim, Sunsook;Kim, Hyegi;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.63-71
    • /
    • 2020
  • Purpose : The purpose of this study is to analyze the elements that affect the energy consumption of general hospitals in Korea. Methods : Factors affecting energy consumption in general hospitals include facility elements and operating elements. The effects of these elements on energy consumption of general hospitals were analyzed by statistical methods such as t-test, anova, correlation analysis, and regression analysis. Results : Total floor area, number of operating rooms, number of MRI, number of staffs, and number of outpatients can be said as useful variables that can explain energy consumption in general hospitals. Implication : It is possible to save energy consumption in general hospitals by adjusting major variables that affect the energy consumption of general hospitals.

Reinforcement Learning Based Energy Control Method for Smart Energy Buildings Integrated with V2G Station (강화학습 기반 V2G Station 연계형 스마트 에너지 빌딩 전력 제어 기법)

  • Seok-Min Choi;Sun-Yong Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.3
    • /
    • pp.515-522
    • /
    • 2024
  • Energy consumption is steadily increasing, and buildings in particular account for more than 20% of the total energy consumption around the world. As an effort to cost-effectively manage the energy consumption of buildings, many research groups have recently focused on Smart Building Energy Management Systems (BEMS), which are deepening the research depth by applying artificial intelligence(AI). In this paper, we propose a reinforcement learning-based energy control method for smart energy buildings integrated with V2G station, which aims to reduce the total energy cost of the building. The results of performance evaluation based on the energy consumption data measured in the real-world building shows that the proposed method can gradually reduce the total energy costs of the building as the learning process progresses.

A Study on the Development of the Advanced Energy Performance Indicator for the Manufacturing Companies (제조업체의 에너지성과지표 고도화에 관한 연구)

  • Rho, Kyung-Wan;Song, Myung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.31-38
    • /
    • 2015
  • It is important to improve the energy performance in the industrial sector, and therefore most of the manufacturing companies need the energy performance indicators to identify the target and to verify the energy savings. However, the conventional energy performance indicators such as the total energy consumption and the energy intensity are not proper to use. The reason is that they do not consider adequate relevant variables including productions in the boundary of the manufacturing companies. Therefore, the study provides the advanced energy performance indicator using by the linear regression model according to each energy source to manage the target and to verify the energy performance properly.

The Relationship between Energy Consumption and Factors Affecting Heating and Cooling

  • Park, Kwon Sook;Kim, Seiyong
    • Architectural research
    • /
    • v.19 no.1
    • /
    • pp.7-11
    • /
    • 2017
  • Energy consumption in university building has steadily increased over the last decade, and a strong upward trend in recent years. This study was undertaken to analyze the relationship between energy consumption and their affecting factors, six academic buildings were considered. The factors limited to heating and cooling, which is the main end use (nearly 60 per cent of total energy consumption in university buildings), encompassing system and operating schedules (user activity) and area use. To understand how to building is used, operated and managed, walk-through assessment was conducted as well as interview with university staff. The results show that the energy consumption of the humanities building was somewhat smaller than the consumption of the science and engineering building, and its range was from $31.26kgoe/m^2$ to $23.52kgoe/m^2$, depending on heating and cooling system and area use. And the energy consumption of the science and engineering building was related to operating schedules (user activity) as well as laboratory equipment characteristics. More analysis on a larger number of buildings is required in the future, including building form and material performance level to generalize the significant factors influencing building energy consumption.