• 제목/요약/키워드: Torque measurements

검색결과 162건 처리시간 0.023초

분전반 내 차단기의 접속불량에 의한 이상발열에 관한 연구 (A Study on the Abnormal Heating of Circuit Breaker in Panel Board by Poor Connection)

  • 김향곤;김동우;최효상;최용성;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.10-14
    • /
    • 2008
  • In this paper, abnormal heating of circuit breaker in panel board by poor connection was studied. Firstly, calculation method of contact resistance shown in IEC 60943 was examined. Secondly, concerning abnormal heating of circuit breaker in panel board, field measurements were performed. Field measurements showed that locally abnormal heating by poor connection could be detected, therefore, in that case, immediate action was needed. Finally, experiments regarding abnormal heating between terminal of circuit breaker and electric wire were conducted. The results showed that abnormal heating above $180^{\circ}C$ was measured. Also, in the results of analysis of electrical waveforms according to load current, voltage drop occurred around poor connection, and the oxide was generated according to mechanical vibration. In order to prevent electrical disaster caused by poor connection, adequate torque should be applied to electrical connection, and periodic check-ups are needed.

  • PDF

IN VITRO COMPARATIVE STUDY BETWEEN ISQ AND $PERIOTEST^{(R)}$ VALUES ON THE IMPLANT STABILITY MEASUREMENTS ACCORDING TO THE INCREASED EFFECTIVE IMPLANT LENGTH

  • Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.625-632
    • /
    • 2001
  • Statement of Problem. Objective and quantitative measurement of implant stability is very important from implant installation to long-lasting maintenance period thereafter. Purpose of study. This study was to evaluate and compare two ISQ and PTVs on the implant stability measurements according to the increased effective implant length. Materials and methods. Twenty self-tapping fixtures were installed in the bovine scapula and in 10 of those for group I, ISQ and PTVs were obtained in the vertical/horizontal directions according to the increased effective implant length using $Osstell^{TM}$ and $Periotest^{(R)}$. After stability measurement, removal torques were measured between the after installation and after thread exposure group. Results. ISQ and PTVs showed decreased and increased values according to the increased abutment length. Apart from PTVs, ISQ values were shown higher in horizontal direction to the long axis of bone in both the after installation and the after thread exposure groups. Removal torque values were shown higher in after installation group. Conclusion. From the results of this study, implant stability measurement using resonance frequency analysis was more sensitive and discriminative than PTVs measurement.

  • PDF

컴퓨터를 이용한 치아크기 계측시 재현도와 정확도에 관한 연구 (Reproducibility and accuracy of tooth size measurements obtained by the use of computer)

  • 김은정;황현식
    • 대한치과교정학회지
    • /
    • 제29권5호
    • /
    • pp.563-573
    • /
    • 1999
  • 본 연구는 치아크기 측정시 버니어 캘리퍼스를 사용한 계측치와 석고모형을 촬영하여 컴퓨터를 사용한 계측치를 서로 비교함으로써 석고모형 분석시 컴퓨터 이용 가능성을 알아보고자 시행되었다. 치아밀집치열 특징을 지니며 모든 치아의 맹출이 완료된 상하악 20조의 석고 모형의 좌측 중절치부터 제 1대구치까지 12개의 치아를 대상으로 하여, 각 치아의 근원심폭경을 버니어 캘리퍼스와 컴퓨터를 이용하여 2주 간격으로 2회 측정하여 실험측정치를 얻은 다음, 측정에 이용된 석고모형을 근원심접촉점 부위에서 개개치아로 분리한 후, 마이크로미터를 이용하여 측정한 표준치와 비교분석하였다. 계측시 오차의 원인을 알아보기 위하여 상하악의 occlusogram을 얻어 각 치아의 접촉점 이탈유무 및 정도를 구하고, TARG (Torque Angulation Reference Guide)를 이용하여 각 치아의 근원심경사도를 계측한 결과 다음과 같은 결론을 얻었다. 1. 2회 측정에 대한 재현도 비교시 버니어 캘리퍼스를 사용한 경우 12 개 치아 중 3개의 치아에서 유의한 차이가 나타났으며 컴퓨터의 경우에는 1 개의 치아에서 차이가 나타났다. 2. 치아크기 계측의 정확도를 알아보기 위하여 표준치와 비교한 결과, 버니어 캘리퍼스를 사용한 경우 12개 중 3개의 치아에서 유의한 차이가 있었으며 컴퓨터의 경우에는 12 개 중 2 개의 치아에서 차이가 나타났다. 3. 버니어 캘리퍼스를 사용한 경우 상악 제 1 대구치는 표준치에 비해 크게, 하악 제 1 대구치는 표준치에 비해 작게 재는 경향을 보였으며 컴퓨터의 경우 상하 제 1 대구치 모두 표준치에 비해 크게 재는 경향을 보였다. 4. 버니어 캘리퍼스로 계측시에는 하악 제 1 대구치가 가장 큰 오차를 보였으며 치아별로 오차정도가 다양하게 나타난 반면, 컴퓨터의 경우 치아별 오차정도의 차이를 보이지 않았다. 5. 접촉점 이탈정도 및 치관의 근원심 경사도와 오차정도의 상관성을 살펴본 결과 버니어 캘리퍼스로 측정한 경우 유의한 상관관계를 보이지 않았으나 컴퓨터로 계측한 경우 약한 순상관관계를 보였다. 이상의 결과는 모형분석을 위한 치아크기 계측시 컴퓨터 이용이 가능함을 시사하였다.

  • PDF

A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae

  • Di Stefano, Danilo Alessio;Arosio, Paolo;Piattelli, Adriano;Perrotti, Vittoria;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.51-55
    • /
    • 2015
  • PURPOSE. Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them. MATERIALS AND METHODS. A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data. RESULTS. The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement. CONCLUSION. The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제51권6호
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

고속 전동기용 2 패드 빔 타입 가스 포일 저널 베어링의 회전체동역학 성능 측정 (Rotordynamic Performance Measurements of a Two-Pad Beam-Type Gas Foil Journal Bearing for High Speed Motors)

  • 정권종;황성호;백두산;김태영;김태호
    • Tribology and Lubricants
    • /
    • 제38권5호
    • /
    • pp.205-212
    • /
    • 2022
  • This paper presents experimental measurements of the structural characteristics of a two-pad beam-type gas foil journal bearing and its rotordynamic performance for a high-speed motor-driven turbocompressor. The test bearing had two top foils and two beam foils, each with an arc length of ~180°. Each beam foil was etched to obtain 40 beams with six geometries of different lengths and widths. The insertion of beam foils into the bearing housing produces equivalent beam heights. The structural tests of the bearing with a non-rotating journal revealed a smaller bearing clearance and larger structural stiffness for the load-on-pad configuration than for the load-between-pads configuration. Rotordynamic performance measurements during driving tests up to 100 krpm demonstrated synchronous vibrations and subsynchronous vibrations with large amplitudes. The test was repeated after inserting the shim between the top foil and beam foil to reduce the bearing radial clearance. The reduced bearing clearance resulted in a reduction in the peak amplitude of the synchronous vibrations and an increase in the speed at which the peak amplitude occurred. In addition, the onset speed and amplitude of the subsynchronous vibrations were dramatically increased and diminished, respectively. The rotor coast-down tests at 100 krpm show that the reduction in the bearing clearance extends the time to rotor stop, thus implying an improvement in hydrodynamic pressure generation and a reduction in bearing frictional torque.

호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구 (A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE)

  • 조수미;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

임플란트 healing abutment 높이와 타진각도에 따른 타진방식 임플란트 안정성 측정기기의 수치 차이 (Differences in percussion-type measurements of implant stability according to height of healing abutments and measurement angle)

  • 박양훈;이성복;이석원;백장현;이정열
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.278-286
    • /
    • 2018
  • 목적: 인조골에 동일한 조건으로 식립한 임플란트에 대하여 타진방식의 임플란트 안정성 측정기기인 Periotest와 AnyCheck을 사용하여 안정성 수치를 측정함에 있어서, healing abutment의 높이와 타진각도의 변화에 따른 각 측정기기의 안정성 수치 차이를 조사하는 것이다. 재료 및 방법: 총 60개의 임플란트를 주문제작한 인조골 블록에 식립하고 2, 3, 4, 5 mm 높이의 healing abutment를 각각 15개씩 네 그룹으로 나누어 체결하였으며, 각각 식립 토크, implant stability test, Periotest value를 측정했다. 임플란트 식립 시 45 - 55 Ncm의 토크를 유지하였다. 임플란트 장축에 수직인 지면을 기준으로, implant stability test는 AnyCheck을 사용하여 $0^{\circ}$, $30^{\circ}$의 기울기로 측정했으며 Periotest value는 Periotest M을 사용하여 $0^{\circ}$, $30^{\circ}$의 기울기로 측정하였다. 측정값은 통계적으로 비교 분석하였다. 결과: 식립 토크는 그룹 간 통계적 유의차가 없었다. AnyCheck과 Periotest M으로 측정했을 때, healing abutment의 높이가 증가할수록 안정성 수치가 낮게 측정되었다. 또한 AnyCheck과 Periotest M을 $0^{\circ}$$30^{\circ}$ 기울기로 측정 시 $0^{\circ}$로 측정한 그룹에서 안정성 수치가 더 낮게 측정되었다. 결론: 임플란트의 안정성 수치를 타진방식으로 측정할 때에는 healing abutment 높이와 타진각도의 변화에 따른 차이를 고려하여 측정해야 표준화된 평가를 할 수 있으며, 이에 대한 더욱 세밀한 사용법을 인지할 필요가 있다고 사료되었다.

포트형상에 따른 정상상태 조건하에서의 희박엔진 연소실내의 유동특성 (In-Cylinder Flow Characteristics of a Lean Burn Engine under Steady Conditions for Different Port Shapes)

  • 박상봉;이은현;유정열;이준식;최해천
    • 한국자동차공학회논문집
    • /
    • 제6권3호
    • /
    • pp.26-33
    • /
    • 1998
  • An experimental study has been conducted for the three-dimensional in-cylinder swirl flow under steady conditions. Velocity fields are measured by using an LDV at various valve lifts. Effects of geometry of inlet ports on swirl flows are investigated for standard and helical ports. Swirl distributions evaluated from velocity measurements are compared with those obtained from an impulse torque swirl meter. Results show that the helical port generates more intensive swirl than the standard one but it causes red- uction in air flow coefficient. At the lower valve lift, no significant difference is observ- ed in non-dimensional swirl values between two ports because of limited pre-swirl effect, while it becomes significant as the valve lift increases.

  • PDF

Analysis and Comparison of a Permanent-Magnet DC Motor with a Field-Winding DC Motor

  • Kiyoumarsi, Arash
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.370-376
    • /
    • 2009
  • The influence of magnetic saturation on electromagnetic field distribution in both a permanent-magnet direct-current (PMDC) motor and a field-winding (wound-field) direct-current (FWDC) motor, with the same output mechanical power, has been studied. In this paper, an approximate analytical method and time-stepping Finite Element Method (FEM) are used for prediction of Back-EMF and electromagnetic torque. No-load and rotor-lucked conditions, according to experimental measurements, and the FEM and analytical method studies of the motors have been considered. A sensitivity analysis has also been successfully accomplished on the major design parameters that affect motor performance. At last, these two DC motors are compared, in spite of their differences, on the basis of measured output characteristics.