A PORTABLE TORQUE AND POWER MEASUREMENT SYSTEM FOR SMALL FARM EQUIPMENT BASED ON AN INSTRUMENTED PULLEY

  • Pasikatan, M.C.;Quick, G.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.298-306
    • /
    • 1993
  • A portable torque and power measurement system for small farm equipment based on instrumented pulley was developed. The prototype pulley was machined from mild steel, with spokes serving as strain beams. Strain gages mounted to the spokes sense the bending strain due to the torque and convert this into millivolt output. Calibration results showed the torque-millivolt relationship was linear, while hysterisis and error were less than 1% fs. For power measurements, an additional tachmeter with dcvoltage output is necessary. With the tachometer , error in power measurement was +-1.03W or 0.2% fs. Field tests showed that for ease of installation, no machine alteration needed and safety, this system had advantage over other methods for small farm equipment.

  • PDF

Nonlinear Robust Control of Passenger Car Torque Converter Bypass Clutch (승용차용 토크컨버터 바이패스 클러치의 비선형 견실제어)

  • Han, Jin-Oh;Kang, Soo-Joon;Lee, Kyo-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1251-1258
    • /
    • 2003
  • This paper presents a nonlinear robust approach to the slip control problem for a torque converter bypass clutch in a passenger car. The proposed nonlinear robust controller builds upon only the measurements avail-able from inexpensive sensors that are already installed in passenger cars for control. The issue of torque estimation problems for the implementation of the proposed controller is addressed. The stability of the internal dynamics is investigated, upon which a nonlinear robust controller is designed using input-output feedback linearization and Lyapunov redesign technique. The performance of the designed controller is validated by simulation studies.

Development of High Precision Forward Slip Model By Using Roll Torque in Hot Strip Finishing Mill (압연롤 토크를 이용한 열연박판 마무리압연 선진율 예측 정밀도 개선연구)

  • 문영훈;김영환
    • Transactions of Materials Processing
    • /
    • v.8 no.6
    • /
    • pp.583-590
    • /
    • 1999
  • New forward slip model has been developed for the precise prediction of rolling speed in the hot strip finishing mill. Besides those influential factors such as neutral point, work roll diameter, friction coefficient, bite angle and the thickness at each side of entry and delivery of the rolls, roll torque was specifically taken into account in this study. To consider the effect of width change on forward slip, calibration factors obtained from rolling torque has been added to new prediction model and refining method has also been developed to reduce the speed unbalance between adjacent stands. The application of the new model showed a good agreement in rolling speeds between the predictions and the actual measurements, and the standard deviation of prediction error has also been significantly reduced.

  • PDF

Experimental Verification and Prediction of Generating Performance of PMG with Multi-Pole Rotor based on Electromagnetic Analysis and Parameter Estimation considering Skew Effects (스큐를 고려한 다극 영구자석 발전기의 전자기 특성해석/제어정수 도출을 통한 발전특성 예측 및 실험적 검증)

  • Jang, Seok-Myeong;Choi, Jang-Young;Ko, Kyoung-Jin;Park, Ji-Hoon;Lee, Sung-Ho;Kim, Ii-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.752-753
    • /
    • 2008
  • The analytical expressions for magnetic field distributions considering slotting effects, cogging torque and back-emf considering skew effects are established. On the basis of magnetic field solutions, electrical parameters such as back-emf constant and winding inductance are obtained. The predicted results are validated extensively by non-linear finite element (FE) analyses. In particular, test results such as back-emf, cogging torque, inductance and resistance measurements are given to confirm the analyses. Finally, generating performances are investigated by applying estimated parameters to equivalent circuit (EC) of the permanent magnet generator (PMG) and validated extensively by FE calculations and measurements.

  • PDF

Experimental Analyses of Flow in a Production Torque Converter Using LDV (LDV를 이용한 토크컨버터 내 유동의 실험적 분석)

  • Yoo, S.C.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.757-762
    • /
    • 2018
  • LDV(laser Doppler velocimetry) measurements were conducted on the exit region of the impeller passage and the gap between the impeller and turbine blades under 0.8 speed ratio. The 0.8 speed ratio has an impeller speed of 2000rpm and a turbine speed of 1600rpm. A periodic variation of the mass flow rate is present in many of the measurements made. The frequency of this variation is the same as the frequency of the turbine blades passing the impeller passage exit. It is found that the instantaneous position of the turbine had effect on fluid flow inside the impeller passage and gap region. This study would aid in the construction of higher accuracy CFD models of this complex turbomachinery device.

Modeling of High-speed Tapping Touque Considering Friction Force (마찰력을 고려한 고속탭핑 토크 모델링)

  • Lee, Don-Jin;Gang, Ji-Ung;Jeon, Hyeon-Bae;Kim, Seon-Ho;An, Jung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.67-73
    • /
    • 2001
  • This paper aims at developing a torque model for the high-speed tapping with small-diameter taps. As recent industries such as automobile and information technology grows, taps smaller than 5mm in diameter are needed much more. In that occasion, the friction force between a tap surface and a workpiece plays much more important role in the tapping torque than in he larger tapping. Tapping mechanism was analysed based on the tap geometry. It has two steps : one is a forward cutting composed of the chamfered threading and full threading and the other is the backward cutting. The torque by the cutting force in the chamfered threading is calculated using the cutting area and the specific cutting force while the torque by the friction force, which is rather dominant than the cutting force both in the full threading and in the backward cutting, is calculated using the normal force on the threads and the friction coefficient. The experiment has shown that the results by the proposed torque model fit quite well with the acutal measurements within the error of 10%.

  • PDF

Study on engine performance and emissions using alcohol-gasoline blend as a fuel (Alcohol-gasoline 기관의 성능과 배출물에 관한 연구)

  • 김응서;김효경;유재석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.51-60
    • /
    • 1980
  • Experiments about engine performance using alcohol-gasoline blend as a fuel are studied. A conventional 4cycle 4cylinder gasoline engine is used. Measurements on torque, output, specific fuel consumption, and emissions are made over ignition timing and mixing ratio. Up to vol. 15% of alcohol, torque and output using alcohol-gasoline blend are almost same with using only gasoline, and specific fuel consumption is improved about 7%. In emissions alcohol-gasoline blend is more effective than gasoline.

  • PDF

MEASUREMENT OF FIELD PERFORMANCE FOR TRACTOR

  • M. J. NahmGung;Park, C. H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.819-826
    • /
    • 2000
  • This study was performed to develop a measurement system of tractor field performance for plow and rotary operations. Measurement system for tractor consisted of torque sensors to measure torque of drive axles and PTO axle, speed sensors to measure rotational speed of drive axles and engine, microcomputer to control data logger, and data logger as I/O interface system. The measurement system was installed on four-wheel-drive tractor. Four-element full-bridge type strain gages were used for torque measurement of drive axles and optical encoders were used to measure speeds of drive axles and engine. Slip rings were mounted on the rotational axles. Signals from sensors were inputted to data logger that was controlled by microcomputer with parallel communication. Sensors were calibrated before the field tests. Regression equations were found on completion of the calibrations. The field experiment was performed at paddy fields and uplands. Rotary and plow were used when the tractor was operated in the field. Travelling speeds of the tractor were 1.9 km/h, 2.7 km/h, 3.7 km/h, 5.5 km/h, 8.2 km/h, and 11.8 km/h. Operating depths of implements were maintained approximately 20cm during the tests. Torque data of drive axles were different at each location during plow and rotary operations. Results showed that torque of rear axles were greater than those of front axles. Total torque were 6860 - 11064 Nm at the upland and 7360 - 14190 Nm at the paddy field for plow operations. It was found that torque at the paddy field were about 20% greater than those at the upland for plow operations. Torque data showed that rotary operations required less power than plow operation at the paddy field and the upland. Torque measurements at each axle for rotary operations were only 8 - 16% of plow operations in the upland and 15 - 20% in the paddy field.

  • PDF

Measurement of outgassing rates of Kevlar and S-Glass materials used in torque tubes of High Tc Superconducting (HTS) Motors

  • Thadela, S.;Muralidhar, BVAS;Kalyani, B;Choudhury, UK;Yadav, SN;Rao, V.V.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.11-15
    • /
    • 2018
  • Torque tubes in High Temperature Superconducting (HTS) motor transfer torque from superconducting field winding rotor to the room temperature shaft. It should have minimum heat conduction property for minimizing the load on cryo-refrigerator. Generally, these torque tubes are made with stainless steel material because of high strength, very low outgassing and low thermal contraction properties at cryogenic temperatures and vacuum conditions. With recent developments in composite materials, these torque tubes could be made of composites such as Kevlar and S-Glass, which have the required properties like high strength and low thermal conductivity at cryogenic temperatures, but with a reduced weight. Development and testing of torque tubes made of these composites for HTS motor are taken up at Bharat Heavy Electricals Limited (BHEL), Hyderabad in collaboration with Central Institute of Plastics and Engineering Technology (CIPET), Chennai and Indian Institute of Technology (IIT), Kharagpur. As these materials are subjected to vacuum, it is important to measure their outgassing rates under vacuum conditions before manufacturing prototype torque tubes. The present study focusses on the outgassing characteristics of Kevlar and S-Glass, using an Outgassing Measurement System (OMS), developed at IIT Kharagpur. The OMS facility works under vacuum environment, in which the test samples are exposed to vacuum conditions over a sufficient period of time. The outgassing measurements for the composite samples were obtained using pressure-rise technique. These studies are useful to quantify the outgassing rate of composite materials under vacuum conditions and to suggest them for manufacturing composite torque tubes used in HTS motors.