• Title/Summary/Keyword: Torque distribution

Search Result 320, Processing Time 0.038 seconds

Characteristic Analysis of Hi9h Torque Hybrid PM Step Motor for the Optimum Design (고 토크형 Hybrid PM 스텝모터의 최적설계를 위한 특성해석)

  • Lee, Tae-Hwa;Kong, Jeong-Sik;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.870-872
    • /
    • 2000
  • This paper deals with the effect of rotor thickness variation and winding method in high torque hybrid Permanent Magnet(PM) step motor. As these parameters vary. The flux distribution in airgap and torque characteristics are influenced, which is related to output power. efficiency and cost. These parameters and characteristic variations were evaluated by using Finite Element Method (FEM) and experiment method. From these results. Characteristic analysis for the optimum design was studied and prototype motor was made to test performance analysis.

  • PDF

Effect of Implant Designs on Insertion Torque and Stress : Three-Dimensional Finite Element Analysis (임플란트 디자인이 식립 회전력과 응력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Kim, Jang-Eung;Choi, Yu-Sung;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.205-220
    • /
    • 2010
  • Purpose : To analyze the effect of implant designs on insertion torque and stress by performing a comparative study on von Mises stress, torque and normal force through a three-dimensional finite element analysis. Materials and methods : Models of the screw type implant were used to model the implant as a form placed in the mandibular premolar region applying a three-dimensional finite element method. Screw type implant designs were classified into 4 types of parallel ones and 7 types of tapered ones. Other factors were simulated to represent clinical environment. Results : In parallel implant designs, higher and wider threads resulted in higher insertion torques and higher stress distributions. In tapered implant designs, changes in the taper led to remarkable differences in the insertion torques. It was difficult to determine a certain tendency of stress distribution around the implants since the stress level was too high around them. In tapered implant designs, smaller implants demonstrated lower insertion torques than the original type and were relatively less dependent on the degree of taper. Tapered implants showed higher insertion torques and higher stress distributions than parallel implants. Conclusion : According to this study, although the tapered implant demonstrated a higher insertion torque than the parallel implant, stress tended to be concentrated in the entire fixture of the tapered implant due to the inefficient stress distribution.

Torque Distribution Algorithm of Independent Drive Articulated Vehicle for Small Radius Turning Performance (독립 구동 굴절차량의 회전반경 감소를 위한 토크분배 알고리즘)

  • Lee, Kibeom;Hwang, Karam;Tak, Junyoung;Suh, In-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.336-341
    • /
    • 2014
  • The articulated structures seen in train or tram applications are being applied in road transportation systems, for use in mass passenger transit. When articulated vehicles are driven on public roads, they no longer follow a guided track. Therefore, there are a lot of control elements that need to be considered, such as turning radius, swept path width, off-tracking, and swing-out. Some of the currently available articulated vehicles on roads are equipped with an independent drive system; a system that has one motor at each wheel. Through this drive system, each wheel can be independently controlled, making precise and quick dynamic stability control possible. In this paper, we propose a torque distribution algorithm that can reduce the overall turning radius of the articulated vehicle, which has been verified through dynamic simulation.

The Effect of Dynamic Lumbar Stabilization Exercise to Be Affected with Improvement and Maintenance of Trunk Stability after Opened Microscopic Laser Discectomy (개방형 현미경적 요추간판 제거술 후 동적 요부 안정화 운동에 따른 체간 안정성의 개선과 유지)

  • Nam, Kun-Woo;Kim, Jong-Soon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.37-48
    • /
    • 2005
  • Objects: This study is designed to analysis improvement and maintaince of trunk stability targeting patients who need post operative rehabilitation exercise after undergoing opened microscopic laser discectomy(OMLD) due to HNP. Method: Between March 2004 and February 2005 a total sixty patients who underwent OMLD due to $L_4/L_5$, $L_5/S_1$ HNP and who agreed to the experiment were subject for this study. Experimental group consisted of 18 subjects, and they underwent 45 minutes dynamic lumbar stabilization exercise And control group consisted of 18 subjects who conducted conservative physical therapy based on the use of physical modality for 45 minutes except to exercise. Results: Experimental group that was lumbar extensor's isometric peak torque, weight distribution of both leg, trunk muscle balance and Oswestry LBP disability index increased during 12 weeks in a statistically significant manner compared to before exercise (p<.05). When re-test was tried, isometric peak torque (p>.05) and Oswestry LBP disability index(p<.05) maintained 12th week level or improved. Weight distribution rate of both leg and trunk muscle balance maintained the level of 8th week of exercise execution(p<.05). Control group that was lumbar extensor's isometric peak torque, weight distribution rate of both leg and trunk muscle balance aggravated during 12 weeks compared to pre-test(p>.05) But, Oswestry LBP disability index increased in a statistically significant level compared to pre-test(p<.05). When re-test was tried, isometric peak torque increased slightly compared to pre-test, but decreased when at least $60^{\circ}$ flexion angle(p>.05). Weight distribution rate of both leg and trunk muscle balance also aggravated compared to pre-test(p>.05), and Oswestry LBP disability index was similar to the 4th week of physical therapy execution(p>.05). Conclusion: Successive postoperative Especially, Application of dynamic lumbar stabilization exercise program is important than traditional lumbar strengthening exercise program in the maintaince of spinal stability.

  • PDF

A Study on Output and Design of Permanent Magnet Synchronous Motor with Dual-gap (300W급 이중 공극 구조 PMSM 설계 및 출력 특성에 관한 연구)

  • Kim, Seung-Joo;Kim, Youn-Hwan;Choi, Han-Suk;Moon, Jae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.80-87
    • /
    • 2014
  • This paper suggests the dual-gap for generating power and increasing the torque of a direct-drive permanent magnet synchronous motor in a hybrid-cycle. To consider easy coil winding, we applied a structure of dual-gap for the permanent magnet synchronous motor (PMSM). Because the torque of PMSM with the dual-gap is very large, we are designed the appropriate specifications of the PMSM by selected the appropriate dual-gap slot and poles combination. The prototype model is selected by design theory for increasing torque and maximizing output power of PMSM. And the detailed structure design of the model was designed by the loading distribution method. The PMSM models were analyzed by finite element method. Finally, we have suggested appropriate rotor structure has benefit to further increasing torque and prevent decreasing of the output power in PMSM with dual-gap.

Direct Torque Control of Squirrel Cage Typed Induction Motor Using Fuzzy Controller (퍼지제어기를 이용한 농형 유도 전동기의 직접 토크제어)

  • Han, Sang-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.122-129
    • /
    • 2008
  • The direct torque control method of an inverter fed squirrel cage typed induction motor using fuzzy logic controller has been proposed. This method is suitable for the traction which requires a fast torque response during the star-up and step change. The fuzzy control algorithm based upon the control principles of conventional DSC(Direct Self Controller) is developed. The fuzzy algorithm is tarried out by defuzzification strategy of the fuzzy output extracted from the possibility distribution of an inferred fuzzy control rule. The flux and torque of an induction motor are estimated by the dynamic model of the rotor flux field-oriented scheme which has decoupling characteristics and excellent dynamic response over a wide speed range. The proposed controller shows a good dynamic response. Moreover, since the fuzzy controller possesses highly adaptive capability, the performance of fuzzy controller is quite robust and insensitive to the motor parameters and change of operation conditions.

REMOVAL TORQUE OF BICORTICALLY STABILIZED RBM(RESORBABLE BLAST MEDIA) PIN IMPLANTS IN RABBIT TIBIA

  • Kim, Kwon-Sik;Suh, Kyu-Won;Lee, Richard Sung-Bok;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.722-733
    • /
    • 2006
  • Statement of problem. The use of small diameter implants having less than 3 mm in diameter were restricted because of lack of bonding strength to bone. Purpose. The purpose of this study was to observe how much resorbable blast media pin implants increase the binding force to the bone compared to machined transitional pin implants by measuring removal torque, and whether they can be used as final implants for replacement of small diameter teeth. Material and method. Fifteen rabbits were used in this study. Two kinds of implants (resorbable blast media pin implants and machined transitional pin implants) were inserted in each tibia bicortically. After healing time of 2, 4 and 8 weeks, the removal torque values were recorded and the rabbits were sacrificed for histological analysis. Linear finite element method analyses were conducted to compare bicortical fixation with monocortical fixation. Result and conclusion. Within the limitation of this in vivo study, the following conclusions were drawn: 1) The removal torque value of RBM pin implants showed statistically significant increase compared to machined pin implants at 2, 4, and 8 weeks respectively (p<0.05). 2) The removal torque value of RBM pin implants at 2, 4, and 8 weeks was increased statistically significantly with time (p<0.05). 3) Bicortical fixation showed better stress distribution compared with monocortical fixation in a linear finite element method analysis. 4) RBM pin implants are not recommended as transitional implants because they showed a lot of bone fracture in histologic specimens.

The Analysis of Space Flux Distribution in Squirrel-cage Induction Motor Driving the Unbalanced Voltage (불평형 전원에 의해 구동되는 3상 농형 유도 전동기의 공간 자속분포 해석)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Kim, Jong-Kyum;Kim, Il-Jung;Oh, Yung-Su;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.225-227
    • /
    • 1996
  • The paper is described the analysis of spacing flux distribution, EMF and torque pulsation in unbalanced voltage squirrell-cage induction motor using finite element method.

  • PDF

Reduction of Vibration and Noise of BLDC Motors by Realizing Sinusoidal Air-Gap Flux Density Distribution (BLDC 전동기의 정현적 공극 자속밀도 구현에 의한 진동.소음 저감)

  • Kim, Samuel;Jeong, Seung-Ho;Kwon, Byung-Il;Kim, Hong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.95-97
    • /
    • 2006
  • Cogging torque is often a principal source of vibration, noise and difficulty of control in BLDC motors. Therefore, this paper will present a design method of magnetization system with sinusoidal air-gap flux density distribution of Nd-Fe-B magnets in ring type for reduction of Vibration and Noise and low manufacturing cost.

  • PDF

Characteristics Analysis of Induction Motor by Operation of Non-linear Loads under the 3-Phase 4-Wire Grid System (3상 4선식에시 비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.54-62
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.