• Title/Summary/Keyword: Torque assist

Search Result 56, Processing Time 0.026 seconds

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS (처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향)

  • Yang, Seoung-Wook;Lim, Heon-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

Characteristics of the Muscular Activities with Elbow Orthosis using Pneumatic Rubber Muscle (공압 고무 엑츄에이터를 장착한 주관절 보조기 착용에 따른 상지 근력 특성)

  • Hong, K.J.;Kim, K.;Kwon, T.K.;Kim, D.W.;Kim, N.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.825-831
    • /
    • 2007
  • An elbow orthosis with a pneumatic rubber actuator has been developed to assist and enhance upper limb movements and has been examined for the effectiveness. The effectiveness of the elbow orthosis was examined by comparing muscular activities during alternate dumbbell curl exercises with and without the orthosis. The subjects participated in the experiment were younger adults in their twenties. The subjects were instructed to perform dumbbell curl motion in a sitting position with and without orthosis in turn and a dynamometer was used to measure elbow joint torque outputs in an isovelocity mode. The measurements were done with four various dumbbell loads: 0 kg, 1 kg, 3 kg, and 5 kg. The orthosis was pneumatically actuated and controlled in a passive mode. The most comfortable air pressure to the pneumatic actuator was determined to be 0.294MPa. Electromyography(EMG) was also measured during curl exercises. The muscles of interest were biceps brachii(BB), triceps brachii(TB), brachioradialis(Bo), and flexor carpi ulnaris(FCU) in the upper limbs. The experimental results showed that the muscular activities themselves significantly reduced with elbow orthosis on in performing similar activities without orthosis. As a result of this experiment, the effectiveness of the developed upper limb orthosis was confirmed and the level of assistance was quantified.

Improving Fuel Efficiency of a Hybrid Excavator (하이브리드 굴삭기 연비 개선 연구)

  • Cho, Sungwoo;Yoo, Seungjin;Park, Cheol-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.211-217
    • /
    • 2015
  • Emission gas regulations and constantly increasing fuel costs call for the worldwide use of environmentally friendly and energy-efficient machines in industry. To meet these requirements, a hybrid excavator prototype has been developed that incorporates an electric swing motor, engine assist motor, and ultra-capacitor module into a conventional hydraulic excavator of the 22-ton class. This paper mainly describes a few techniques to optimize its energy efficiency. These include 1) controlling the engine speed in proportion to the load torque, 2) controlling the pump displacement when driving the electric swing system, 3) managing the ultra-capacitor voltage to minimize the electrical energy loss, and 4) reducing the cooling fan speed to improve the energy efficiency of the system.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

Analysis on the Assist Characteristics for the Knee Extension Motion of Lower Limb Orthosis Using Muscular Stiffness Force Feedback (근육 강성도 힘 피드백을 이용한 하지 보조기의 무릎 신전 운동 보조 특성 분석)

  • Kim, K.;Kang, S.R.;Jeong, G.Y.;Joo, S.J.;Kim, N.G.;Kwon, T.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.217-226
    • /
    • 2010
  • The lower limb orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of muscular activities of lower limbs was developed in this study. Compared to other knee extension assistive devices being developed by other researchers, our device is designed especially for the elderly people and intended only for slight assistance so that the subjects can keep their muscular strength. For the effectiveness of system, muscular activities of major muscles in lower limbs during sit-to-stand (STS) and squat motion were measured and analyzed. Subjects were performed the STS and squat motion with and without lower limb orthosis. We made comparison muscular activities between with and without lower limb orthosis. Lower limb orthosis was controlled using muscular stiffness force feedback that is controlled by muscular activities of the measured muscle from force sensor. For analysis of muscular activities, electromyography of the subjects was measured during STS and squat motion, and these were measured using MP 150(BIOPAC Systems, Inc.). Muscles of interest were rectus femoris(RF), vastus lateralis(VL), vastus medialis(VM) and vastus intermedius(VI) muscles in lower limbs of the right side. A biodex dynamometer was used to measure the maximal concentric isokinetic strength of the knee extensors of wearing and not wearing orthosis on right side. The test were performed using the concentric isokinetic mode of test with the velocity set at 60°/s for muscles around the knee joints. The experimental result showed that muscular activities in lower limbs wearing orthosis using muscular stiffness force of a vastus medialis muscle was reduced and knee extension torque of an knee joint wearing lower limb orthosis was increased. With this, we confirmed the effectiveness of the developed lower limb orthosis.