• Title/Summary/Keyword: Topology configuration

Search Result 181, Processing Time 0.023 seconds

A Study on Thrust Generation by Simultaneous Flapping Airfoils in Tandem Configuration (동시에 플래핑하는 직렬배치 익형의 추력 생성 연구)

  • Lee, Gwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.32-41
    • /
    • 2006
  • In this study, the thrust generation by simultaneous flapping airfoils in tandem configuration is parametrically studied with respect to flapping frequency, amplitude and relative location. Navier-Stokes solver with overset grid topology is employed to calculate the unsteady flowfields. The computation results indicate that when the two airfoils stroke in-phase - flapping phase lag is zero - the maximum propulsive efficiency and thrust can be obtained for most frequency and amplitude range. At a flapping amplitude of 0.2 chord and a reduced frequency of 0.75, the propulsive efficiency of aft airfoil is enhanced by about 37 % compared with that of forward airfoil. However, if flapping frequency exceeds some critical value, the strength of the leading edge vortex of aft airfoil is fortified by the trailing edge vortex of the forward airfoil, resulting in poor propulsive efficiency. It is also found that out-of-phase flapping has relatively low propulsive efficiency and thrust since vortical wake of the forward airfoil interacts with the leading edge vortex of aft airfoil in the unfavorable fashion. The total thrust and propulsive efficiency are shown to decrease with the horizontal miss distance of the aft airfoil. On the contrary, the vertical miss distance has little effect on the overall aerodynamic performance.

An evaluation of the pipe failure impact in a water distribution system considering subsystem isolation (상수관 파괴시 관망의 부분적 격리를 고려한 피해범위 산정)

  • Jun, Hw-Andon
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.2 s.163
    • /
    • pp.89-98
    • /
    • 2006
  • To evaluate the pipe failure impact, current methodologies consider only a broken pipe as the impacted area. However, these approaches are accurate if the broken pipe is the only area isolated from tile system. Depending on the number and locations of on-off valves, more pipes which are adjacent to a broken pipe may be isolated. Using the concept of Segment suggested by Walski, the methodology evaluating the pipe failure impact incorporated with on-off valve locations has been suggested by Jun. However, a segment cannot account for all possible pipe failure impacted areas since it does not consider additional failures, namely the network topological failure and the hydraulic pressure failure. For this reason, a methodology which can consider the network topology and hydraulic pressure limitation as well as on-off valve locations is suggested. The suggested methodology is applied to a real network to verify its applicability As results, it is found that a single pipe failure can affect huge areas depending on the configuration of on-off valves and the network topology. Thus, the applicability of the suggested methodology for evaluating the pipe failure impacts on a water distribution network is proved.

Design of a Nuclear Fuel Spacer Grid Considering Impact and Wear (충격과 마모를 고려한 원자로 핵연료봉 지지격자의 설계)

  • Lee, Hyun-Ah;Kim, Chong-Ki;Song, Kee-Nam;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.10
    • /
    • pp.999-1008
    • /
    • 2007
  • The spacer grid set is a component in the nuclear fuel assembly. The set supports the fuel rods safely. Therefore, the spacer grid set should have sufficient strength for the external impact forces such as earthquake. The fretting wear occurs between the spring of the fuel rod and the spacer grid due to flow-induced vibration. Conceptual design of the spacer grid set is performed based on the Independence Axiom of axiomatic design. Two functional requirements are defined for the impact load and the fretting wear, and corresponding design parameters are selected. The overall flow of design is defined according to the application of axiomatic design. Design for the impact load is carried out by using nonlinear dynamic analysis to determine the length of the dimple. Topology optimization is carried out to determine a new configuration of the spring. The fretting wear is reduced by shape optimization using the homology theory. The deformation of a structure is called homologous if a given geometrical relationship holds before, during, and after the deformation. In the design to reduce the fretting wear, the deformed shape of the spring should be the same as that of the fuel rod. This condition is transformed to a function and considered as a constraint in the shape optimization process. The fretting wear is expected to be reduced due to the homology constraint. The objective function is minimizing the maximum stress to allow a slight plastic deformation. Shape optimization results are confirmed through nonlinear static analysis.

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

Design of MMIC Variable Gain LNA Using Behavioral Model for Wireless LAM Applications (거동모델을 이용한 무선랜용 MMIC 가변이득 저잡음 증폭기 설계)

  • Park, Hun;Yoon, Kyung-Sik;Hwang, In-Gab
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.6A
    • /
    • pp.697-704
    • /
    • 2004
  • This paper describes the design and fabrication of an MMIC variable gain LNA for 5GHz wireless LAN applications, using 0.5${\mu}{\textrm}{m}$ gate length GaAs MESFET transistors. The advantages of high gain and low noise performance of E-MESFETS and excellent linear performance of D-MESFETS are combined as a cascode topology in this design. Behavioral model equations are derived from the MESFET nonlinear current voltage characteristics by using Turlington's asymptote method in a cascode configuration. Using the behavioral model equations, a 4${\times}$50${\mu}{\textrm}{m}$ E-MESFET as a common source amplifier and a 2${\times}$50${\mu}{\textrm}{m}$ D-MESFET as a common gate amplifier are determined for the cascode amplifier. The fabricated variable gain LNA shows a noise figure of 2.4dB, variable gain range of more than 17dB, IIP3 of -4.8dBm at 4.9GHz, and power consumption of 12.8mW.

Development of TDMA-Based Protocol for Safety Networks in Nuclear Power Plants (원전 안전통신망을 위한 TDMA 기반의 프로토콜 개발)

  • Kim, Dong-Hoon;Park, Sung-Woo;Kim, Jung-Hun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.303-312
    • /
    • 2006
  • This paper proposes the architecture and protocol of a data communication network for the safety system in nuclear power plants. First, we establish four design criteria with respect to determinability, reliability, separation and isolation, and verification/validation. Next we construct the architecture of the safety network for the following systems: PPS (Plant Protection System), ESF-CCS (Engineered Safety Features-Component Control System) and CPCS (Core Protection Calculator System). The safety network consists of 12 sub-networks and takes the form of a hierarchical star. Among 163 communication nodes are about 1600 origin-destination (OD) pairs created on their traffic demands. The OD pairs are allowed to exchange data only during the pre-assigned time slots. Finally, the communication protocol is designed in consideration of design factors for the safety network. The design factors include a network topology of star, fiber-optic transmission media, synchronous data transfer mode, point-to-point link configuration, and a periodic transmission schedule etc. The resulting protocol is the modification of IEEE 802.15.4 (LR-WPAN) MAC combined with IEEE 802.3 (Fast Ethernet) PHY. The MAC layer of IEEE 802.15.4 is simplified by eliminating some unnecessary (unctions. Most importantly, the optional TDMA-like scheme called the guaranteed time slot (GTS) is changed to be mandatory to guarantee the periodic data transfer. The proposed protocol is formally specified using the SDL. By performing simulations and validations using Telelogic Tau SDL Suite, we find that the proposed safety protocol fits well with the characteristics and the requirements of the safety system in nuclear power plants.

A Study on Security Routing using MD5 in MANET Environments (MANET 환경에서 MD5를 이용한 보안 라우팅에 관한 연구)

  • Lee, Cheol-Seung;Jung, Sung-Ok;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.728-731
    • /
    • 2008
  • Recently demands in construction of the stand-alone networks and interconnection between convergence devices have led an increase in research on IETF MANET working group, Bluetooth, and HomeRF working group and much attention has been paid to the application of MANET as a Ubiquitous network which is growing fast. With performance both as hosts and routers, easy network configuration, and fast response, mobile nodes participating in MANET are suitable for Embedded computing, but have vulnerable points, such as lack of network scalability and dynamic network topology due to mobility, passive attacks, active attacks, which make continuous security service impossible. For perfect MANET setting, routing is required which can guarantee security and efficiency through secure routing. In routing in this study, hashed AODV is used to protect from counterfeiting messages by malicious nodes in the course of path 'finding and setting, and disguising misrouted messages as different mobile nodes and inputting them into the network.

  • PDF

Optimization of a Nuclear Fuel Spacer Grid Using Considering Impact and Wear with Homology Constraints (호몰로지 조건을 이용하여 충격과 마모를 고려한 원자로 핵연료봉 지지격자의 최적설계)

  • Lee, Hyun-Ah;Kim, Chong-Ki;Song, Kee-Nam;Park, Gyung-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.145-150
    • /
    • 2007
  • The spacer grid set is a component in the nuclear fuel assembly. The set supports the fuel rods saftely. Therefore, the spacer gl1d set should have sufficient strength for the external impact forces. The fretting wear occurs between the spring of the fuel rod and the spacer grid due to tile flow-induced vibration. The conceptual design of the spacer grid set is performed based on the Independence Axiom of axiomatic design. Two functional requirements are defined and corresponding design parameters are selected. The overall flow of the design is defined according to the application of axiomatic design. The design for the impact load is carried out by using nonlinear dynamic analysis to determine the length of the dimple. Topology optimization is carried out to determine a new configuration of the spring. The fretting wear is reduced by shape optimization using the homology theory. In the design to reduce the fretting wear, the deformed shape of the spring should be the same as that of the fuel rod. This condition is transformed to a function and considered as a constraint in the shape optimization process. The fretting wear is expected to be reduced due to the homology constraint. The objective function is minimizing the maximum stress to allow a slight plastic deformation. Shape optimization results are confirmed through nonlinear static analysis because the contact area becomes wider.

  • PDF

A Case Study on Logical Network Separation through HCI method (HCI 방식을 통한 논리적 망분리 사례 연구)

  • Choi, Seoung Pyo;Shin, Sang Uk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.747-749
    • /
    • 2017
  • To protect financial services against danger of financial accidents and customer information leakage caused by malware, injection attack and so on, Financial Services Commission announced "Financial Networks Security Enhancement Comprehensive Plan", which suggests the guideline of protecting customer information and providing secure financial services by separating network topology and then makes the financial company use network partitioning system. In consequence of this policy, financial companies respectively chose between the physical partitioning mechanism or the logical partitioning mechanism according to their IT environment. This paper suggests an efficient infrastructure configuration plan for making the logical network partition, by comparison of a construction of traditional general equipment and an integrated HCI(Hyper Converged Infrastructure) through 'Hyper Converged' which is one of virualization techniques for developing currently, and the case study of the integrated HCI method.

  • PDF

A Building Method of High Availability Protection Architecture in Next Generation Network (NGN) Information Security System (차세대통신망(NGN) Infrastructure에서의 정보보호시스템 고가용성 차단구조 설계)

  • Noh, Si-Choon;Bang, Kee-Chun
    • Journal of Digital Contents Society
    • /
    • v.8 no.4
    • /
    • pp.483-489
    • /
    • 2007
  • The high availability of information security system shall be primarily studied in relation to the Next Generation Network(NGN) Information Security infrastructure, because it is very important to maintain availability at each moment as a variety of intrusions occur continuously. The high availability of the security system can be realized with the topology and configuration properly defined to fully utilize the recovery function of the security system in the thoroughly planned optimized method. The active-active high availability on the NGN information security infrastructure system in is assured by letting the failover mechanism operate upon the entire structure through the structural design and the implementation of functions. The proposed method reduces the system overload rating due to trouble packets and improves the status of connection by SNMP polling trap and the ICMP transport factor by ping packet.

  • PDF