• Title/Summary/Keyword: Top-Base

Search Result 518, Processing Time 0.024 seconds

Earthquake-resistance Analysis of Piles Using Dynamic Winkler Foundation Model (동적 Winkler 보 모델을 이용한 말뚝의 내진해석)

  • 장재후;유지형;정상섬
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.39-49
    • /
    • 2002
  • This paper describes a numerical method for pile foundation subjected to earthquake loading using dynamic Winkler foundation model. To verify the numerical method, shaking table tests were carried out. In shaking table tests, accelerations and pile bending moments were measured for single pile and pile groups with a spacing-to-diameter ratio of 2.5 under fixed input base acceleration. In numerical analysis, the input base and free field accelerations measured from shaking table tests were used as input base motions. Based on the results obtained, free field acceleration was magnified relative to input base acceleration, whereas pile head accelerations reduced relatively to free field acceleration for soil-pile interaction. Measured and predicted bending moments for both cases have maximum value within the distance 10cm(4d) from the pile top. However, there are some differences between the results of numerical analysis and shake table test below 10cm(4d) from the pile top.

Binding Mode and Inhibitory Activity of Constituents Isolated from Sclerotium of Poria cocos with DNA Topoisomerase I (Poria cocos 균핵에서 분리한 성분들과 DNA Topoisomerase I의 반응양상 및 효소저해 활성)

  • Choi, Inhee;Kim, Ji-Hyun;Kim, Choonmi
    • YAKHAK HOEJI
    • /
    • v.49 no.5
    • /
    • pp.428-436
    • /
    • 2005
  • DNA topoisomerase I(TOP1) helps the control of DNA replication, transcription and recombination by assist­ing breaking and rejoining of DNA double strand. Camptothecin (CPT) and its derivative, topotecan, are known to inhibit TOP1 by intercalating into TOP1-DNA complex. Recently various non-CPT intercalators are synthesized for a new class of TOP1 inhibitors. In this study, six compounds isolated from Poria cocos were investigated for their interaction with TOP1­DNA complex using the flexible docking program, FlexiDock. The binding modes were analyzed and compared with the TOP1 inhibition activities. The compounds that showed potent activity were intercalated between the + 1/-1 base pairs of DNA, located near the active site phosphotyrosine723 and formed hydrogen bonds with active site residues. On the other hand, compounds with no activity were not docked at all. The binding modes were well correlated with the inhibition activity, suggesting the possibility that potent inhibitors can be designed from the information presented by the docking study.

Vxworks Base Java Virtual Machine Development (VxWorks Base Java Virtual Machine 개발)

  • 박상현;고재진;민수영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06c
    • /
    • pp.193-196
    • /
    • 2002
  • Nowadays, many users use internet and many set-top box needs browser for Internet. so we need to develop a Java Virtual Machine to improve browser's performance. This paper has been studied a Java Virtual Machine based on Real-Time 05 Vxwroks. Java Virtual Machine handles Java byte-code quickly in Browser So, this paper has designed module and interfaces for Embedded Browser and Implemented them.

  • PDF

Projecting Performance of a Daylighting Source Based on Its Architectura Applications in the Open-Top Surface Structure (고심도 공간의 건축적 특성에 따른 자연집광 시스템의 조명원적 성능분석)

  • Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A lightcourt design is typically used to address issues concerning aesthetics, feeling, and mood. From the view point of environmental aspect, as an ecological shaft space, it plays a key role in controlling inner quality. In particularly, the lightcourt concept allows the exploitation of daylighting by bring natural light into the center of the building, thus eliminating dark deep spaces. Additionally, the lightcourt shades the inner space in summer. The amount of light available at the base of the lightcourt depends on a number of factors; translucency of the top, reflectance and the geometry of the space. In this paper is to exemplify a lightcourt configuration with a sloped wall. It promises the maximized a sense of freedom and daylighting availability. It is a matter of course that the lightcourt with open-top plays a role as a light source for the adjacent space to the lightcourt. A series of lighting simulation provides performance data of daylighting with changing photometric factors. For the case that a skylight is not available, an electric lighting design with metal halide lamps has been established to create luminous ceiling. As expected, a sloped lightcourt with open-top exposes its superiority of daylighting source. Ancillary considerations to enhance of daylighting potential for the adjacent space have been issued with performance data.

Design and calibration of a semi-active control logic to mitigate structural vibrations in wind turbines

  • Caterino, Nicola;Georgakis, Christos T.;Spizzuoco, Mariacristina;Occhiuzzi, Antonio
    • Smart Structures and Systems
    • /
    • v.18 no.1
    • /
    • pp.75-92
    • /
    • 2016
  • The design of a semi-active (SA) control system addressed to mitigate wind induced structural demand to high wind turbine towers is discussed herein. Actually, the remarkable growth in height of wind turbines in the last decades, for a higher production of electricity, makes this issue pressing than ever. The main objective is limiting bending moment demand by relaxing the base restraint, without increasing the top displacement, so reducing the incidence of harmful "p-delta" effects. A variable restraint at the base, able to modify in real time its mechanical properties according to the instantaneous response of the tower, is proposed. It is made of a smooth hinge with additional elastic stiffness and variable damping respectively given by springs and SA magnetorheological (MR) dampers installed in parallel. The idea has been physically realized at the Denmark Technical University where a 1/20 scale model of a real, one hundred meters tall wind turbine has been assumed as case study for shaking table tests. A special control algorithm has been purposely designed to drive MR dampers. Starting from the results of preliminary laboratory tests, a finite element model of such structure has been calibrated so as to develop several numerical simulations addressed to calibrate the controller, i.e., to achieve as much as possible different, even conflicting, structural goals. The results are definitely encouraging, since the best configuration of the controller leaded to about 80% of reduction of base stress, as well as to about 30% of reduction of top displacement in respect to the fixed base case.

In-Cylinder Flow Analysis in a Spark-ignited Direct Injection Engine using CFD (CFD를 이용한 직접 분사식 스파크 점화 엔진의 실린더 내부 유동 해석)

  • 김명환;이내현;최규훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.22-30
    • /
    • 1999
  • Optimization of in-cylinder flow is regarded as one of the most important factors to realize stable stratified charge combustion in a Spark-ignited Direct Injection(SDI) engine. Therefore, Computational Fluid Dynamic(CFD) simulation technique were used to clarify the characteristics of in-cylinder flow of a SDI engine with top entry intake port. Also, CFD results were compared to experimental results using Laser Doppler Velocimetry(LDV), Particle Image Velocimetry(PIV) and good validations were met. As the results reverse tumble flow generated during intake process was preserved by configuration of curved piston while base and reverse tumbles were diminished at the end of compression stroke in case of flat top piston. In addition, it will be needed to optimize the fuel mixture distribution based on these results.

  • PDF

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • v.18 no.2
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

Design theory and method of LNG isolation

  • Sun, Jiangang;Cui, Lifu;Li, Xiang;Wang, Zhen;Liu, Weibing;Lv, Yuan
    • Earthquakes and Structures
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • To provide a simplified method for the base isolation design of LNG tanks, such as $16{\times}104m^3$ LNG tanks, we conducted a derivation and calculation example analysis of the dynamic response of the base isolation of LNG storage tanks, using dynamic response analysis theory with consideration of pile-soil interaction. The ADINA finite element software package was used to conduct the numerical simulation analysis, and compare it with the theoretical solution. The ground-shaking table experiment of LNG tank base isolation was carried out simultaneously. The results show that the pile-soil interaction is not obvious under the condition of base isolation. Comparing base isolation to no isolation, the seismic response clearly decreases, but there is less of an effect on the shaking wave height after adopting pile top isolation support. This indicates that the basic isolation measures cannot control the wave height. A comparison of the shaking table experiment with the finite element solution and the theoretical solution shows that the finite element solution and theoretical solution are feasible. The three experiments are mutually verified.

Effects of Higher Modes on the Response Spectra of High-rise Buildings considering the Kinematic Interaction of a Foundation System (기초체계의 운동학적 상호작용을 고려한 고층건물의 응답스펙트럼에 미치는 고차모드의 영향)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.85-92
    • /
    • 2015
  • Response spectra of a building are made with a SDOF system taking into account a first mode shape, even though higher modes may affect on the dynamic responses of a high-rise building. A soft soil layer under a building also affects on the responses of a building. In this study, seismic responses of a MDOF system were investigated to examine the effects of higher modes on the response of a tall building by comparing them with those of a SDOF system including the kinematic interaction effect. Study was performed using a pseudo 3D finite element program with seven bedrock earthquake records downloaded from the PEER database. Effects of higher modes on the seismic responses of a tall building were investigated for base shear force and base moment of a MDOF system including story shear forces and story moments. Study results show that higher modes of a MDOF system contribute to a reduction of base shear force up to 1/4-1/5 of KBC and base moment. The effect of higher modes is more significant on the base shear force than on the base moment. Maximum story shear force and moment occurred at the top part of a building rather than at a base in the cases of tall buildings differently from short buildings, and higher modes of a tall building affected on the base forces making them almost constant at the base. A soft soil layer also affects some on the base shear force of a high-rise building independently on the soft soil type, but a soft soil effect is prominent on the base moment.

Horizontal only and horizontal-vertical combined earthquake effects on three R/C frame building structures through linear time-history analysis (LTHA): An implementation to Turkey

  • Selcuk Bas;Mustafa A. Bilgin
    • Computers and Concrete
    • /
    • v.34 no.3
    • /
    • pp.329-346
    • /
    • 2024
  • In this study, it is aimed to investigate the vertical seismic performance of reinforced concrete (R/C) frame buildings in two different building stocks, one of which consists of those designed as per the previous Turkish Seismic Code (TSC-2007) that does not consider the vertical earthquake load, and the other of which consists of those designed as per the new Turkish Seismic Code (TSCB-2018) that considers the vertical earthquake load. For this aim, three R/C buildings with heights of 15 m, 24 m and 33 m are designed separately as per TSC-2007 and TSCB-2018 based on some limitations in terms of seismic zone, soil class and structural behavior factor (Rx/Ry) etc. The vertical earthquake motion effects are identified according to the linear time-history analyses (LTHA) that are performed separately for only horizontal (H) and combined horizontal+vertical (H+V) earthquake motions. LTHA is performed to predict how vertical earthquake motion affects the response of the designed buildings by comparing the linear response parameters of the base shear force, the base overturning, the base axial force, top-story vertical displacement. Nonlinear time-history analysis (NLTHA) is generally required for energy dissipative buildings, not required for design of buildings. In this study, the earthquake records are scaled to force the buildings in the linear range. Since nonlinear behavior is not expected from the buildings herein, the nonlinear time-history analysis (NLTHA) is not considered. Eleven earthquake acceleration records are considered by scaling them to the design spectrum given in TSCB-2018. The base shear force is obtained not to be affected from the combined H+V earthquake load for the buildings. The base overturning moment outcomes underline that the rigidity of the frame system in terms of the dimensions of the columns can be a critical parameter for the influence of the vertical earthquake motion on the buildings. In addition, the building stock from TSC-2007 is estimated to show better vertical earthquake performance than that of TSCB-2018. The vertical earthquake motion is found out to be highly effective on the base axial force of 33 m building rather than 15 m and 24 m buildings. Thus, the building height is a particularly important parameter for the base axial force. The percentage changes in the top-story vertical displacement of the buildings designed for both codes show an increase parallel to that in the base axial force results. To extrapolate more general results, it is clear to state that many buildings should be analyzed.