• 제목/요약/키워드: Top heat loss coefficient

검색결과 5건 처리시간 0.019초

Effect of Air Gap Thickness on Top Heat Loss of a Closed-loop Oscillating Heat Pipe Solar Collector

  • Nguyen, Kim-Bao;Choi, Soon-Ho;Yoon, Doo-Ho;Choi, Jae-Hyuk;Oh, Cheol;Yoon, Seok-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권7호
    • /
    • pp.994-1002
    • /
    • 2009
  • In this paper, effect of air gap thickness between absorber plate and glass cover on top heat loss of a closed loop oscillating heat pipe (CLOHP) solar collector was investigated. The CLOHP, which is made of copper with outer diameter of 3.2mm and inner diameter of 2.0mm, comprises 8 turns with heating, adiabatic and cooling section. The heating section of the heat pipe was attached to absorber plate which heated by solar simulator simulated by halogen lamps. The cooling section of the heat pipe was inserted into collector's cooling section that made of transparent acrylic. Temperatures of absorber plate, glass cover, and ambient air measured by K-type thermocouple and were recorded by MV2000-Yokogawa recorder. Top heat loss coefficients and top heat loss of the collector corresponding to some cases of air gap thickness were determined. The result of experiment shows the optimal air gap thickness for minimum top heat loss of this solar collector.

태양열 이용 냉난방 공조시스템중 평판형 집열기의 동계 상부 열손실 해석 (Analysis of the Top Loss Coefficient for Flat Plate Collector in a Solar Air-Conditioning System during Winter)

  • 김보철;최광환;금종수;김종렬
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.15-24
    • /
    • 1998
  • 태양열 집열기의 열손실은 크게 3가지 즉 상부 열손실, 하부 열손실, 측부 열손실로 대별되나 단열이 양호한 집열기에서는 일반적으로 측면으로의 열손실은 무시한다. 측부 열손실을 제외한 두 열손실 중에서도 상부 열손실은 집열기의 대부분의 열손실을 차지하는 지배적인 요소이다. 따라서 태양열 집열기의 집열 성능을 정확하게 파악하기 위해서는 상부 열손실 계수를 정확하게 계산할 필요가 있다. 본 연구에서 사용한 평판형 태양열 집열기(재생기)는 하계에는 제습 및 냉방을 행하고 동계에는 난방을 행하는 전천후 집열판으로 제작되었다. 따라서 장치의 전환없이 겨울에 난방용으로 사용하였을 경우의 집열 성능을 파악하기 위하여 옥외에서 실험을 하였다. 동계 기간 실험을 통하여 본 집열기의 상부 열손실 계수는 약 $3{\sim}4.5W/m^2^{\circ}C$임을 알 수 있었다. 그리고 집열표면에 선택흡수막을 입혀서 난방용으로 사용하면 주위와의 복사 열손실을 크게 줄일 수 있기 때문에 본 집열기의 집열 성능을 향상시킬 수 있을 것으로 사료된다.

  • PDF

마이크로핀관과 평활관에서의 증발열전달과 압력손실 특성 (Evaporation heat transfer and Pressure loss in micro-fin tubes and a smooth tube)

  • 장세환;정시영;홍영기
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.215-223
    • /
    • 1999
  • Evaporation heat transfer coefficient and pressure loss were measured for three different micro-fin tubes and a smooth tube. The experiments were carried out with R-22 over a wide range of vapor Quality, mass velocity and heat flux. Heat transfer coefficient of the tube with slightly modified fin shape was found to be higher than that of the commercial reference tube by 60%. The improvement of heat transfer has been achieved without noticeable increase of pressure loss. Heat transfer coefficient was increased with increasing quality, refrigerant mass flux, and heat flux. However, the effect of refrigerant mass flux and heat flux was not great. Heat transfer coefficient at bottom was lower than that at top of the tube in low quality region, which suggested the existence of stratification in the micro-fin tube. Pressure drop was linearly increased with increasing refrigerant quality and was proportional to about square of mass flux.

  • PDF

주위의 열대류계수가 다를때 사각핀으로부터의 열손실에 대한 비대칭적인 핀바닥온도의 영향 (Effect of Asymmetric Root Temperature on the Heat Loss From a Rectangular Fin Under Unequal Surrounding Heat Convection Coefficient)

  • 강형석;김성준
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1567-1571
    • /
    • 1994
  • Under the assumption that thermal conductivity of the fin is constant and the conditions ate steady state, effects of non-constant and thermally asymmetric root temperature and unequal surrounding convection coefficients of the fin on the heat loss from a fin of rectangular profile are investigated. The heat loss form a rectangular fin becomes maximum when the highest root temperature deviates from the fin center to the fin side which has a higher convection coefficient as surrounding convection coefficients of the fin increase and as the difference between the convection coefficient of fin top side and that of fin bottom side increases.

수조내 증기제트 응축현상 제고찰 (Review of Steam Jet Condensation in a Water Pool)

  • 김연식;송철화;박춘경
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.74-83
    • /
    • 2003
  • APR1400과 같은 차세대 원자력발전소에서는 원자로 안전성을 증진시키기 위하여 SDVS와 같은 계통을 도입하고 있다. 완전급수상실사고와 같은 경우는 POSRV가 개방되어 수조내 Sparger를 통하여 증기가 방출·응축되게 된다 증기가 응축함에 있어서 설계에서 고려해야 될 사항은 하중과 수조 혼합이며 증기제트 응축의 물리적 현상 이해를 통하여 적절한 대처를 마련할 수 있다. 수조내 Sparger를 통하여 분사되는 증기 응축에 대하여 하중과 수조 혼합 검토에 도움이 될 수 있도록 증기제트 응축의 물리적 현상 이해에 대한 검토와 평가를 수행하였다.