• Title/Summary/Keyword: Tooth-colored material

Search Result 20, Processing Time 0.025 seconds

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)

COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN (4종의 간접법용 복합 레진의 기계적 특성 비교)

  • Kim, Kil-Soo;Yoon, Tae-Ho;Song, Kwang-Yeob;Ahn, Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

Fracture load and marginal fitness of zirconia ceramic coping by design and coloration (유색 및 백색 지르코니아 세라믹 코핑의 코핑 디자인에 따른 파절 하중과 변연 적합성)

  • Shin, Mee-Ran;Kim, Min-Jeong;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.406-415
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the marginal fitness and fracture load of the zirconia copings according to the design with different thickness and coloration. Material and methods: The evaluation was based on 80 zirconia copings. Zirconia copings were fabricated in design with different thicknesses using CAD/CAM system (Everset, KAVO dental GmbH, Biberach, Germany). The designs of copings were divided into four groups. The first group consisted of copings with uniform thickness of 0.3 mm. The thickness in the second group was 0.3 mm on the buccal surface and 0.6 mm on the lingual surface. The third group consisted of coping with uniform thickness of 0.6 mm. The thickness in the fourth group was 0.6 mm on the buccal surface and 1mm on the lingual surface. Each group consisted of 10 colored and 10 uncolored copings. Half of the copings (40) processed with a milling system according to the specific design were sent to be given a color (A3) through saturation in special dye by a manufacturing company. Just after sintering, the marginal discrepancies of copings were measured on the buccal, lingual, mesial and distal surfaces of metal die, under a Video Microscope System (sv-35, Sometech, Seoul, Korea) at a magnification of $\times$ 100. It was remeasured after the adjusting of the inner surface. Next, all copings were luted to the metal dies using reinforced cement {GC FujiCEM (GC Corp. Tokyo, Japan)} and mounted on the testing jig in a Universal Testing Machine (Instron 4467, Norwood, MA, USA). The results were analyzed statistically using the one-way ANOVA test. Results: The obtained results were as follow: 1. The measured value of marginal discrepancy right after sintering was the greatest in the contraction of the buccal area in all groups, except for group I2. 2. There was no significant difference of marginal fitness among the groups in the colored zirconia group (P<.05). 3. When the marginal fitness among the groups in the uncolored zirconia group was considered, group II2 had the smallest marginal discrepancy. 4. When the colored and uncolored groups with the same design were compared, there was a significant difference between I1 and II1 groups. In group 2, 3, and 4, the uncolored zirconia had the greatest marginal fitness (P<.05). 5. After adjustment of inner surface, there was no significant difference in the marginal fitness in all groups when color and design of the zirconia coping were compared. 6. The fracture load of CAD/CAM zirconia copings showed significant difference in group 1, 2, 3, and 4. I4 and II4 had the strongest fracture load. 7. When groups with different color and same design were compared, all colored groups showed greater fracture load (P>.05), with no significance. Conclusion: There was difference in the marginal fitness according to the design and coloration of zirconia copings right after sintering, but it was decided that the copings may well be used clinically if the inner surface are adjusted. The copings should be thick enough for the reinforcement of fracture strength. But considering the esthetics of the visible surfaces (labial and buccal surface), the thickness of copings may be a little thin, without giving any significant effect on the fracture strength. This type of design may be considered when giving priority to preservation of tooth or esthetics.

Dimensional Changes of Ceromer Crown by Water Absorption (치과용 심미수복재료 세로모에서 수분흡수와 체적 변화에 관한 연구)

  • Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.119-124
    • /
    • 2009
  • Statement of problem: The increasing demand for esthetic restorations has been required developing new materials for tooth colored restoration. Ceromer(Ceramic Optimized Polymer) has some advantages over porcelain, and has gained increasing popularity in restorative dentistry. However, there is little information on the dimensional changes in a clinical restoration in moist conditions. Purpose: This study examined the dimensional changes in Ceromer restorations with a clinical crown shape that were fabricated in a clinical manner. Material and methods: The crowns for the maxillary central incisor were fabricated with two Ceromers($BelleGlass^{(R)}$ and $Targis^{(R)}$) using a similar clinical restoration manufacturing technique. A total of twenty specimens were prepared and immersed in distilled water at room temperature to allow for water absorption. The weight, height and width were measured at 24, 72 and 168 hours. The accumulated ratios of the changes were calculated and evaluated using a paired t-test and an independent independent t-test. Results: The dimensions and weight increased with increasing soaking time. $Targis^{(R)}$ showed significant differences in height and weight between 24 hours and the other times(P<.05). $BelleGlass^{(R)}$ showed significant differences in width and weight between 24 hours and the other times. The two materials showed different changing patterns of the dimensions but there were no statistically significant differences between them. Conclusion: The dimensions and weight of the Ceromer restorations were changed by water absorption. The clinical crown shaped specimen showed more complicated dimensional changes than the simplified specimens.

Spectrophotometric analysis of the influence to shade of zirconia core on the color of ceramic (지르코니아 코아의 색조부여가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석)

  • Baek, Ki-Hyun;Woo, Yi-Hyung;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.409-419
    • /
    • 2008
  • Statement of problem: At all times people have tried to fabricate tooth restorations using tooth colored materials. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. The basic color of zirconia is white to ivory. The color can be partially adapted by veneering it with ceramic materials. However, it would be better if the substructure could already be adapted to the basic color shade of neighboring teeth. By adaptation to the basic shade, it can help to reduce the necessary layer thickness of the veneer ceramic to achieve the desired color. Purpose: The purpose of this study was to spectrophotometrically evaluate the influence of shading of zirconia core on the final shade of all-ceramic restorations using the CIE $L^{*}a^{*}b^{*}$ system. Material and methods: Core specimens (n = 20 per group) of Lava Frame Zirconia, KaVo Everest Zirconia, Digident CAD/CAM Zirconia were fabricated at 20 mm in diameter and 0.5 mm in thickness. Halves of each groups were shaded in A3 color. These core specimens were veneered with A3 porcelain of the recommended manufacturer at thickness of 0.5 mm. CIE $L^{*}a^{*}b^{*}$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan) at 0.5 mm, 0.4 mm, 0.3 mm in thickness. Color differences were calculated using the equation ${\Delta}E^{*}=[({\Delta}L^{*})2+({\Delta}a^{*})2+({\Delta}b^{*})2]1/2$. Results: 1. In the case where porcelain layer has a thickness of 0.5 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, however Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 2. When the thickness of porcelain layer decreased from 0.5 mm to 0.4 mm, Lava Frame Zirconia and KaVo Everest group did not show clinically perceived color difference, on the other hand Digident CAD/CAM Zirconia group showed clinically perceived color difference according to shade allowed on core. 3. When the thickness of porcelain layer decreased from 0.5 mm to 0.3 mm, clinically perceived color differences were observed from all three groups. Conclusions: Ziroconia system, which is possible to allow shade on core, are thought to be much more favorable to reproduce natural shade compared to systems that is impossible to give shade. Therefore, clinicians ought to choose adequate system for certain clinical situation by considering above specific character.

A STUDY ON THE EFFECTS OF FINISHING/POLISHING TIMING ON SURFACE FEATURES OF COMPOSITE RESTORATION (연마시기에 따른 복합레진의 표면 특성에 관한 연구)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Park, Eun-Hae;Lee, Young-Jun;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2004
  • Proper finishing/polishing of dental restorations are critical clinical procedures that enhance both esthetics and longevity of restored teeth. This study was to compare the effects of immediate and delayed finishing/polishing procedures on the surface roughness and surface hardness of tooth-colored restoratives including two microfilled composite resins, such as Filtek A110 and Silux Plus, two hybrid composite resins, such as Revolution formular2 and Palfique Estelite. A total of 48 specimens were made for each material. The first 16 specimens served as the control group and the remaining 32 specimens were randomly divided into two equal groups. The control group was stored in distilled water at $37^{\circ}C$ for 1 week after light polymerization against the Mylar sheet. The first experimental group was finished/polished immediately after light polymerization and stored for 1 week in distilled water at $37^{\circ}C$, whereas the while the second group was finished/polished 1 week after light polymerization and stored in distilled water at $37^{\circ}C$. The results were as follows: 1. The smoothest surface was produced by Mylar sheet and finishing/polishing procedure increased the surface roughness. However, the surface roughness of composite resins were not influenced by the finishing/polishing timing. 2. There were significant differences about surface roughness between Revolution formular 2 and Silux Plus, regarding immediate finishing/polishing, and between Palfique Estelite and Silux Plus regarding delayed finishing/polishing(p<0.05). 3. The sequence of the surface hardness was ascending order by Revolution formular 2, Silux Plus, Filtek A110 and Palfique Estelite. However there were no significant differences about hardness among the control group and two finishing/polishing timing groups. 4. The effects of finishing/polishing time on surface roughness and hardness appeared to be material-dependent.

  • PDF

RADIOPACITY COMPARISON OF TOOTH COLORED RESTORATIVE MATERIALS WITH DIGITAL RADIOGRAPHY (디지털 방사선사진술을 이용한 치아색 수복물의 방사선불투과도 비교)

  • Kim, Hyo-Jung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.499-508
    • /
    • 2000
  • The purposes of this study were to evaluate the validity of 2 kinds of digital radiography techniques in evaluating the radiopacity comparison of restorative materials and to determine the relative radiopacities of several kinds of compomer and flow able resin using these techniques. After taking radiographs of an aluminum step wedge, con-elation of optical density calibration curves were evaluated between conventional radiography with transmission densitometer and CD-Dent digital radiography (storage phosphor system) and between conventional one and RVG$^{(R)}$ digital radiography (CCD system). Compomers such as Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Dyract flow$^{(R)}$, and flowable resins such as Ultraseal-XT$^{(R)}$ plus$^{TM}$, Revolution$^{TM}$, Aeliteflo$^{TM}$ and Tetric-flow$^{(R)}$ were used. Five specimens of 5mm in diameter and 2 mm thick were fabricated with each material. Radiopacities of the materials were measured using the above radiographic techniques and compared. The results were as follows: 1. When the optical density calibration curves were compared, conventional radiography and both CD-Dent and RVG$^{(R)}$ digital radiographies showed very high inverse correlations (${\gamma}$=-0.95, ${\gamma}$=-0.98 ; p<0.05). 2. All the tested restorative materials showed levels of radiopacity the same as or greater than that of dentin (p<0.05), Radiopacities of Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Tetric flow$^{(R)}$ were greater than those of Revolution$^{TM}$, Aeliteflo$^{TM}$, or dentin (p<0.05). 3. Radiopacities of Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Tetric flow$^{(R)}$ were shown to be greater than that of enamel when conventional radiography and CD-Dent digital radiography were used (p<0.05). Radiopacity of Dyract flow$^{(R)}$ was shown to be greater than that of Enamel when conventional radiography was used (p<0.05).

  • PDF

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.