• 제목/요약/키워드: Tooth rotation

검색결과 117건 처리시간 0.022초

임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향 (AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING)

  • 이태식;한중석;양재호;이재봉;김성훈
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).

계속구강건강관리(IDC) 성과에 관한 연구 (A study on the outcome of IDC (Incremental Dental Care))

  • 조민정
    • 한국치위생학회지
    • /
    • 제9권1호
    • /
    • pp.153-168
    • /
    • 2009
  • This study was executed to find out the outcome of Incremental Dental Care from September to November, 2004. 40 visitors to oral health center were examined on the oral conditions every week, seven times during above-mentioned period. Various tests were practiced in order to check their oral conditions before and after IDC such as tooth-brushing method/frequency/duration, calculus index, PHP index, halitosis and dental caries activity. Question and answer sheets were presented to student dental hygienists and 40 visitors respectively after IDC program. Results obtained are as follows. 1. Rotation method of toothbrushing increased from 27.8% to 88.9%. for men and increased from 27.3% to 95% for women. 2. Toothbrushing frequency increased from 2.8 times to 3.0 times a day for men and increased from 2.6 times to 3.1 times for women. Toothbrushing duration increased from 2.3 minutes to 2.8 minutes for men and increased from 2.1 minutes to 2.9 minutes for women. 3. Calculus index reduced from 0.5 to 0.1 for men and reduced from 0.7 to 0 for women. PHP index reduced from 3.7 to 3.0 for men and reduced 3.2 to 1.7 for women. However, halitosis didn't mark any significant difference before and after IDC. 4. Saliva buffering capacity of medium plus showed no change for men(94.5%), however increased from 95.4% to 100% for women. Dental caries activity of medium plus in S.mutans reduced by 4.3 times(72.2% to 16.7%) for men and reduced by 2 times(36.4% to 18.1%) for women. LB test results reduced by 1.5 times(50% to 33.3%) for men and reduced by 2.5 times(50% to 18.1%) for women. Alban's test results reduced by 1.4 times(83.3% to 61.1%) for men and reduced by 1.2 times(81.8% to 68.2%) for women. 5. All participants including visitors and students realized the importance of IDC and expressed a great satisfaction with IDC program. In conclusion, it is considered very necessary that IDC program should be maintained and extended to whole country so as to enhance the peoples' oral health conditions.

  • PDF

전신 질환을 동반한 환아에서 나타난 제1대구치 이소맹출의 처치 (TREATMENT OF ECTOPICALLY ERUPTING FIRST PERMANENT MOLAR IN CHRONIC MYELOGENOUS LEUKEMIA)

  • 김현정;김민정;노홍석;김신;정태성
    • 대한장애인치과학회지
    • /
    • 제7권1호
    • /
    • pp.33-37
    • /
    • 2011
  • 제1대구치의 이소맹출은 국소적 원인과 유전적 원인의 조합에 의한 다양한 요소에 의해서 유발된다. 주기적인 검진과 방사선학적 검사를 통해 비가역적 이소맹출로 판단 될 경우, 제2유구치 조기 상실에 의해 제1대구치의 근심경사나 회전 및 복잡한 교정적인 문제를 일으킬 수 있으므로 적절한 개입이 필요하다. 본 증례는 항암치료의 기왕력이 있는 만성 골수성 백혈병 환아에서 나타난 제1대구치의 이소맹출을 Halterman appliance를 이용하여 정상적인 맹출로 유도할 수 있었다.

임플란트 CT에서 방향 표시자의 방향과 잔존골을 고려한 임플란트 식립 방향의 관계에 관한 연구 (Study of the relationship between the indication rod of stent on implant CT and the real path of implant fixture insertion considering residual ridge)

  • 김도훈;허민석;이삼선;오성욱;최항문;전인성;최순철
    • Imaging Science in Dentistry
    • /
    • 제33권2호
    • /
    • pp.79-83
    • /
    • 2003
  • Purpose : To assess the relationship between the direction of the indicating rod of the radiographic stent for ideal prosthetic design and the actual possible path of implant fixture placement when residual ridge resorption is considered. Materials and Methods: The study materials consisted of 326 implant sites (male 214 cases and female 112 cases) from a total of 106 patients (male 65 patients and female 41 patients) who desired implant prostheses. Computed tomography of patients were taken and reformatted using ToothPix/sup (R)/ software. Bony defects, bony sclerosis, the change of the direction of indicating rod, and root proximity of the adjacent teeth were examined on the CT-derived images. Results: The rate of the irregular crestal cortex was relatively high on premolar and molar area of maxilla. Mandibular molar area showed relatively high rate of focal sclerosis on the area of implant fixture insertion. The position of the indicating rods were relatively acceptable on the molar areas of both jaws. However, the position of the indicating rods should be shifted to buccal side with lingual rotation of the apical end on maxillary anterior teeth and premolar area. Conclusion: Clinically determined rod direction and position of the indicating rod for implant placement was not always acceptable for insertion according to the reformatted CT images. The pre-operative treatment plan for implant should be determined carefully, considering the state of the alveolar bone using the reformatted CT images.

  • PDF

매복 정중치의 진단영상분석 (Diagnostic imaging analysis of the impacted mesiodens)

  • 노정준;최보람;정환석;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제40권2호
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose : The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Materials and Methods : Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. Results : The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. Conclusion : It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

방사광 X-선을 이용한 고해상도 영상획득과 응용 (Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.51-58
    • /
    • 2001
  • 물질의 X-선 흡수도에 의해 영상을 얻는 일반 X-선 시스템과 달리 방사광 X-선은 위상이 일치하고 평행하며 진동방향이 일치하는 특성들을 이용하면 고 분해능, 고 대조도의 투사영상을 얻을 수 있다. 국내에서는 포항 방사광 가속기 연구소에 최근 건설된 5C1 빔라인에 미세구조 X-선 영상 획득을 위한 영상시스템을 구축하여 여러 기초 생물, 의학연구분야의 고 분해능 영상획득이 가능하게 되었다. 방사광 X-선을 이용하여 얻은 고 해상도 투사영상들 및 단층 재구성 영상들을 일반 X-선을 사용하는 유방찰영시스템, 치아 X-선 찰영시스템, 전신측정용 CT 시스템에서 각각 획득한 동일한 대상의 영상들과 비교하였다. 실험에 사용한 방사광 X-선은 6 ~30 keV 사이의 연속적인 에너지 분포를 가지며, 실험의 대상에 따라서 실리콘웨이퍼 필터들을 사용하여 빔의 세기와 에너지 스펙트럼 분포를 조절하여 사용하였다. 실험 대상 물체를 통과한 방사광 X-선의 투사영상은 형광판 (CdWO$_4$ scintillator)과 반응하여 가시광선으로 바뀐 후, 금도금된 거울을 통해 90$^{\circ}$ 반사되어 CCD 카메라로 획득하며, 이러한 디지털 영상정보는 PC로 전송되어 저장된다. 방사광 X-선의 공간 분해능 특성은 X-선 시험패턴(25 $\mu$m)과 초 고해상도 패턴 (13.5 $\mu$m)을 방사광 X-선 영상획득시스템 과 일반 X-선을 사용하는 유방촬영시스템에서 획득하여 분석하였다. 영상획득 실험대상으로는 일반 구조물로 커패시터, 생체조직으로 성인치아, 유아치아, 생쥐 척추뼈 및 유방암조직을 대상으로 실험하였다. 단층영상은 각각의 샘플을 0.72$^{\circ}$ 간격으로 180$^{\circ}$ 회전시켜 250개의 투과영상들로부터 재구성한 후 컴퓨터 단층촬영기에서 얻은 영상과 비교하였다. 포항 방사광가속기연구소 5C1 빔라인에 간단하고, 경제적인 방사광 X-선 영상획득시스템을 성공적으로 구축할 수 있었고, 획득한 투사 영상과 재구성한 단층영상을 기존 X-선을 사용한 시스템으로 획득한 단층영상들과 분해능, 대조도의 특성들을 비교, 분석하였다. 방사광 X-선을 사용하여 획득한 영상들은 일반 시스템에서 얻은 영상보다 고 해상도의 영상 질을 보여주었고, 기초 의학영상 연구 측면에서 많은 정보를 제공해 주었다. 방사광 X-선을 이용한 영상획득시스템은 고 분해능과 고 대조도로 미세구조의 상세한 의학영상을 얻기 위한 유용한 방법으로 활용될 수 있을 것으로 기대된다. 향후 해부학적, 병리학적 및 임상학적 의료영상 분야에 효과적으로 응용하기 위하여 X-선 선량 정량 분석과 수치적 영상 해석연구가 계속되어야 할 것으로 사료된다.

  • PDF

유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상 (The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA)

  • 최인호;차경석;정동화
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.213-230
    • /
    • 2008
  • 최근 치료기간의 단축과 심미성을 동시에 충족시키는 6전치를 설측에서 견인하는 레버암을 이용한 견인방법이 사용되고 있다. 본 연구에서는 상악골의 고전적인 2가지 물성으로 구성된 유한 요소 모델 (단순모델)과 새로이 개발된 24가지 물성으로 구성된 모델 (복합모델)을 생성하여 상악 6전치를 후방 견인 시, 각 치아와 치주인대에 나타나는 초기 이동량과 응력분포를 분석하였다. 23세 성인 남자의 CT 촬영으로 얻은 DICOM 영상정보를 3차원 리버스 엔지니어링 컴퓨터영상프로그램 Mimics를 이용하여 상악골 및 상악 전치부의 3차원 입체영상모델로 재구성하여 finite element analysis (FEA) 모델을 완성하였다. 모델은 상악골, 상악 전치부 각 치아의 치주인대, lingual traction arm의 부분으로 구성되었다. 상악 6전치의 저항중심 부위를 지나도록 교합면에 대하여 평행하게 200g의 후방견인력을 적용한 후 나타나는 초기 이동량 및 응력 분포를 3차원 유한 요소법을 이용한 해석을 통해 비교하였다. 실험 결과 24가지 물성으로 구성된 복합모델이 2가지 물성으로 구성된 단순 모델에 비해 상악 중절치에서 보다 후방 이동되는 양상이 크게 나타났으며 수직적인 회전 양상 역시 크게 나타났다. 두 모델 모두 중절치와 측절치는 조절성 경사이동의 형태로 후방이동양이 견치보다 크게 나타났으나 견치는 이동량이 적은 대신 치근의 이동이 더 크게 나타났다. 수직적 이동양상에 있어 두 모델 모두 측절치와 견치의 접촉점을 중심으로 절치는 하방으로 견치는 상방으로 움직이는 회전양상을 나타났다. 응력의 비교에서는 단순 모델과 복합 모델에서 유사한 결과를 보였다. 비록 각기 다른 물성으로 인해 후방 이동량에서는 차이가 나타났으나 기본적인 치아의 이동양상은 두 모델에서 모두 같게 나타났다.