• Title/Summary/Keyword: Tooth model

Search Result 567, Processing Time 0.026 seconds

Changes in occlusal force depending on the movement of the adjacent and opposing teeth after loss of lower first molar: comparative study by using a strain gauge (하악 제1대구치 상실 시 인접 및 대합 치아들의 이동양상에 따른 교합력 변화: 스트레인게이지를 이용한 비교 연구)

  • Song, Myoung-Ja;Park, Ji-Man;Chun, Youn-Sic
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.47-59
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the changes in occlusal force after loss of the lower first molar depending on the inclination and extrusion of the adjacent and opposing teeth by using a strain gauge. Materials and Methods: Anatomic teeth were used to reconstruct the normal dental arch with loss of the lower right first molar. A uniformly thick layer of silicone was applied to the root to mimic the periodontal ligament. Four stages of dies with varying degrees of inclination and extrusion of the adjacent and opposing teeth were constructed and attached to master model interchangeably by using a CAD/CAM fabricated customized die system. The strain gauges were attached to teeth and a universal testing machine was used to determine the changes in occlusal force. An independent t-test and one-way ANOVA were performed (${\alpha}=.05$). Results: While simulating chewing food, the upper first, second premolar and lower second molar showed greater occlusal force than before extraction. When the change of adjacent teeth's occlusal force with their progressive movement after molar loss was evaluated, the difference among four die models was significant and was in the decreasing aspect (P < 0.05). Conclusion: When the lower first molar was lost and the adjacent teeth did not move yet, the occlusal force in adjacent teeth was higher than that when the lower first molar still existed. In addition, the occlusal force in the upper premolars and lower second molar decreased significantly with the progressive movement of adjacent teeth.

Influence of High Temperature of the Porcelain Firing Process on the Marginal Fit of Zirconia Core (도재 소성 과정에서의 고온이 지르코니아 코어의 변연적합도에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.135-141
    • /
    • 2013
  • One factor for successful prognosis of finished dental prosthesis is good marginal fit. The purpose of this study in vitro investigation was to compare the marginal fit of all-ceramic crown before and after porcelain veneering, to evaluate the influence of high temperature of the porcelain firing on the fit. For this experiment, model of abutment tooth of maxillary right central incisor was prepared. Ten working models were produced. Ten zirconia cores were made by dental computer aided design/computer aided manufacturing system. The marginal fit of specimens were examined using silicone replica technique. Silicone replicas were sectioned four times and were measured through a digital microscope (${\times}160$). Marginal fit is a distance connected between edge end part of specimen and abutment margin. Each specimens was measured twice, the first measurement was done prior to veneering porcelain firing, while the second measurement was done after the porcelain firing to evaluate this process. Statistical analyses were performed with paired t-test. $Mean{\pm}SD$ marginal fit was $60.8{\pm}14.2{\mu}m$ for zirconia core and $86.1{\pm}13.3{\mu}m$ for all-ceramic crown. They were statistically significant differences (p<0.001). But all specimens showed a marginal fit where the gap widths ranged within the clinical recommendation ($120{\mu}m$), all-ceramic crown production using the zirconia core was adequate.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

INFLUENCE OF IMPLANT-ABUTMENT INTERFACE DESIGN, IMPLANT DIAMETER AND PROSTHETIC TABLE WIDTH ON STRENGTH OF IMPLANT-ABUTMENT INTERFACE : THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (임플랜트의 지대주 연결방식, 임플랜트의 직경 및 지대주 연결부위의 직경 차이에 따른 응력분포에 관한 삼차원 유한요소분석)

  • Oh Se-Woong;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.393-404
    • /
    • 2003
  • Statement of problem. Higher incidence of prosthetic complications such as screw loosening, screw fracture has been reported for posterior single tooth implant. So, there is ongoing research regarding stability of implant-abutment interface. One of those research is increasing the implant diameter and prosthetic table width to improve joint stability. In another part of this research, internal conical type implant-abutment interface was developed and reported joint strength is higher than traditional external hex interface. Purpose. The purpose of this study is to compare stress distribution in single molar implant between external hex butt joint implant and internal conical joint implant when increasing the implant diameter and prosthetic table width : 4mm diameter, 5mm diameter, 5mm diameter/6mm prosthetic table width. Material and method. Non-linear finite element models were created and the 3-dimensional finite element analysis was performed to see the distribution of stress when 300N static loading was applied to model at $0^{\circ},\;15^{\circ},\;30^{\circ}$ off-axis angle. Results. The following results were obtained : 1. Internal conical joint showed lower tensile stress value than that of external hex butt joint. 2. When off-axis loading was applied, internal conical joint showed more effective stress distribution than external hex butt joint. 3. External hex butt joint showed lower tensile stress value when the implant diameter was increased. 4. Internal conical joint showed lower tensile stress value than external hex butt joint when the implant diameter was increased. 5. Both of these joint mechanism showed lower tensile stress value when the prosthetic table width was increased. Conclusion. Internal conical joint showed more effective stress distribution than external hex joint. Increasing implant diameter showed more effective stress distribution than increasing prosthetic table width.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS FOR REACTION TO MOLAR UPRIGHTING SPRING (대구치 직립 스프링 적용시 반작용에 관한 삼차원 유한요소법적 연구)

  • Choe, Yoo-Kyung;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.61-74
    • /
    • 1998
  • The Purpose of this study was to investigate the stress distribution and tooth displacement at the initial phase produced by 5 types of molar uprighting springs using finite element method. The three dimensional finite element model of lower dentition, bone and springs was composed of 5083 elements and 2071 nodes. The results were as follows: 1. In case of helical spring and root spring, intrusion of lower canine and first premolar were observed md distal tipping, translation and extrusion of lower second molar were observed. 2. In case of T-loop, modified T-loop and box loop, intrusion and distal translation of lower second premolar were observed, and the largest crown distal tipping and translation of lower second molar were observed in T-loop and the smallest were observed in box loop. 3. In case of T-loop with cinch-bact crown distal tipping and translation of lower second molar were decreased, but extrusion was also decreased. 4. With increase of activation in T-loop, mesial translation and won distal tipping of lower second molar were increased and edentulous space was closing, but distal translation of second premolar was also increased. 5. With increase of tip-back bend in T--loop, distal tipping and translation of lower second molar were increased, but extrusion was also increased more largely.

  • PDF

Effect of caspases and RANKL induced by heavy force in orthodontic root resorption

  • Minato, Yukari;Yamaguchi, Masaru;Shimizu, Mami;Kikuta, Jun;Hikida, Takuji;Hikida, Momoko;Suemitsu, Masaaki;Kuyama, Kayo;Kasai, Kazutaka
    • The korean journal of orthodontics
    • /
    • v.48 no.4
    • /
    • pp.253-261
    • /
    • 2018
  • Objective: Orthodontic root resorption (ORR) due to orthodontic tooth movement is a difficult treatment-related adverse event. Caspases are important effector molecules for apoptosis. At present, little is known about the mechanisms underlying ORR and apoptosis in the cementum. The aim of the present in vivo study was to investigate the expression of tartrate-resistant acid phosphatase (TRAP), caspase 3, caspase 8, and receptor activator of nuclear factor kappa-B ligand (RANKL) in the cementum in response to a heavy or an optimum orthodontic force. Methods: The maxillary molars of male Wistar rats were subjected to an orthodontic force of 10 g or 50 g using a closed coil spring. The rats were sacrificed each experimental period on days 1, 3, 5, and 7 after orthodontic force application. And the rats were subjected to histopathological and immunohistochemical analyses. Results: On day 7 for the 50-g group, hematoxylin and eosin staining revealed numerous root resorption lacunae with odontoclasts on the root, while immunohistochemistry showed increased TRAP- and RANKL-positive cells. Caspase 3- and caspase 8-positive cells were increased on the cementum surfaces in the 50-g group on days 3 and 5. Moreover, the number of caspase 3- and caspase 8-positive cells and RANKL-positive cells was significantly higher in the 50-g group than in the 10-g group. Conclusions: In our rat model, ORR occurred after apoptosis was induced in the cementum by a heavy orthodontic force. These findings suggest that apoptosis of cementoblasts is involved in ORR.

IN VITRO STUDY ON CARIOGENIC POTENTIAL OF SYRUP-FORM MEDICINES FOR CHILDREN (어린이용 시럽제의 우식유발능에 대한 생체 외 연구)

  • Lim, Hwa-Shin;Lee, Kwang-Hee;La, Ji-Young;An, So-Youn;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.2
    • /
    • pp.146-154
    • /
    • 2011
  • An in vitro study on cariogenic potential of 8 over-the-counter syrups for children was performed. The experimental groups were 8 over-the-counter syrups. The positive control group was 10% sucrose solution, and the negative control group was artificial saliva. The pH of each group was determined. The buffering capacity was measured by the volume of 2 N NaOH adding to equalize the pH of 20 ml of experimental solution to pH 7. The consistency was measured by the time to pass Ostwald pipette for 2 ml of the experimental solution. The experimental solutions were inoculated with S. mutans and cultured in $37^{\circ}C$ anaerobic condition for 48 hours. To estimate acid production, pH of the experimental solutions were measured before and after the culture. The primary teeth specimens were soaked in the experimental solutions for 20 minutes three times a day. Except on those hours the specimens were stored in artificial saliva. After 5 days, the microhardness changes of the specimens were measured. These results show that most of syrup-form medicines for children tend to have cariogenic potential partially in endogenous pH, buffering capacity, consistency, acid production and erosive ability of enamel. For the oral health of children, the alternative sweeteners (ex. xylitol) may be substituted for the cariogenic sweeteners of syrups. Additionally, It may be helpful that the chewable tablet replace liquid or syrup in term of dose form.

Advanced airway management for the prehospital traumatic patient (병원 전 환경의 외상성 응급환자를 위한 전문기도관리)

  • Shim, Gyu-Sik;Kim, Eun-Mee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2360-2367
    • /
    • 2013
  • The purpose of this study was to improve the paramedics skills to manage advanced airway by comparing speed and success rate between endotracheal intubation and laryngeal mask airway(LMA) insertion in a moving ambulance. Sixty subjects were randomly recruited and samely divided into control group and experimental group. And they were asked to join a practical experiment using dummy model. Data analysis was done by SPSS WIN 14.0 Version. As a result of this research, in terms of difference in speed according to patient's intubation posture, the speed of control group was indicated to be good in sniffing position(t=-4.038, p<.001). There was no difference in speed between two groups in neutral position. In the neutral posture given the endotracheal intubation, tooth fracture occurred in 16 people(53.3%). There was no difference in success rate between two groups. As for a change in self-confidence before and after experiment, the post self-confidence was indicated to have been enhanced in both groups. In conclusion, it is effective to use LMA in the traumatic patient who is unable to receive endotracheal intubation in sniffing position. It is very important for the paramedics to receive the continuous training of the airway management skills.

Effects of Pulsed Nd:YAG Laser Irradiation and Fluoride Compound Applicatin on Acid Resistance of Bovine Teeth (Pulsed Nd:YAG 레이저 조사와 불소화합물 도포가 치아 내산성에 미치는 영향)

  • An-Hee Lee;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.429-447
    • /
    • 1995
  • This study was designed to determine the most effective concentration of fluoride and levels of laser irradiation for the remineralization of decayed teeth. After irradiation with a pulsed Nd:YAG laser and the topical application of fluoride, phosphate and fluoride concentration in enamel were measured. And then the changes on surface enamel using an scanning electron microscope were observed. Samples by extraction healthy, permanent, mandibular bovine teeth with no caries were obtained. Among them 371 healthy samples were selected and artificial carious lesions were made. 20 samples were assigned to each experimental group. After irradiation with a pulsed Nd:YAG laser with total energy densities of 10J/$\textrm{cm}^2$, 20J/$\textrm{cm}^2$ for each group. On the teeth, 2% NaF, 1.9% NH4F, 1.6% TiF4 Elmex gel(amine fluoride) and 1.23% APF gel were applied. After pH circulatory procedures, concentrations of fluoride with and Ionalyzer (Orion Research, Model 901, USA) and phosphates with an Uv/V is spectrophotometer (Uvikon 860, Kontrom Co, Switzerland) were measured. By etching the teeth in layers and measuring fluoride concentrations, a profile of fluoride penetration according to depth could be developed. And also the changes on the surface of the enamel using an electron scanning microscope were observed. The comparative analysis yielded the following results : 1. Phosphate concentration was low in all groups compared with the control group except for teeth treated Elmex gel, irradiated with 10J/$\textrm{cm}^2$ and 30J/$\textrm{cm}^2$ energy densities. Teeth treated with APF gel and 30J/$\textrm{cm}^2$ irradiation gad the lowest phosphate concentration. 2. Among all groups, fluoride concentrations in tooth enamel were highest in APF gel and NaF groups irradiated at 30J/$\textrm{cm}^2$. The APF gel group had the highest fluoride concentrations across all energy densities. 3. In the APF gel group, and the NaF group, the greater the energy density of the laser, the higher the fluoride concentrations in the enamel. 4. In all groups, the concentration of fluoride in the enamel by depth tended to decrease with depth. 5. Under the scanning electron microscope, under the condition of irradiation with 20J/$\textrm{cm}^2$, enamel crack was detected for the first time. In the NH4F group, spherical deposits were found on the surface of the enamel, and in the TiF4 group the surface of enamel was covered with an irregular, thin membranous mass in places. In the APF gel and NaF groups irradiated with 10J/$\textrm{cm}^2$, spherical and irregular particles covered the teeth. When these groups were irradiated at 20J/cm2, they were covered with amorphous crystals. These results suggest that one could obtain more effective anticariogenic effects without damage to teeth when less than 20J/$\textrm{cm}^2$ energy densities and APF gel are used.

  • PDF

A study for improving the surgical mess using palatal and buccal mucosal incisions in oral and maxillofacial area (구개점막과 협점막의 절개에 사용되는 칼의 개선을 위한 기초 연구)

  • Seo Byoung-Moo;Choi Jin-Young;Lee Jong-Ho;Kim Myung-Jin;Choung Pill-Hoon
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • Disposable blade is widely used for palatal and oral mucosal incision in oral and maxillofadal surgery nowadays, But its design and durability need for improvement, Especially, there are so many hard tissues intraoral area, such as bone and tooth, therefor the sharpness of the surgical blade was easily destroyed, The purpose of this study was to make basic data for developing new design of surgical blade using in oral and maxillofacial area including for the patients who have cleft lip and palate deformities, Some questionnaires about the usefulness of currently used surgical blades were sent to 150 dentists, the 54 of them made a reply, Secondly, The used-once blade and fresh new blade were examined under the scanning electron microscope with the 4000-times magnification, Lastly, the tissue reaction following the surgical incision with a fresh-new and a used blade on rat buccal cheek mucosa and hard palate was evaluated with light microscope with hematoxilin-eosin staining, The time interval from the surgical trauma to taking a sample were 1 day, 3 days, 7 days, and 14 days, At each time schedule, 2 Sprague-Dawley rats were sacrificed, Many dentists were agreed to need for changing the design of the surgical blades and also demand to improve the durability of the blades, They were also eager to adopt the new design of blade if it was available, The blade used in surgical extraction procedure was heavily damaged in its sharpe edge of number 15 blade, The histological differences were not prominent, but the delayed healing was detected in buccal mucosal defects especially in the surgical group with used blade, There are slight different changes in hard palatal defects between a used and a new blade group, In this study, we could find that there are imperative demanding on improvement of surgical blade design and durability for oral and maxillofadal area, The blade currently using in surgical extraction was easily damaged, The animal model of this study was not perfect for the purpose of this study.

  • PDF