• Title/Summary/Keyword: Tooth model

Search Result 571, Processing Time 0.031 seconds

Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners

  • Camardella, Leonardo T.;Ongkosuwito, Edwin M.;Penning, E. Willemijn;Kuijpers-Jagtman, Anne Marie;Vilella, Oswaldo V.;Breuning, K. Hero
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.13-25
    • /
    • 2020
  • Objective: The aim of this study was to compare the accuracy and reliability of measurements performed using two different software programs on digital models generated using two types of plaster model scanners (a laser scanner and a computed tomography [CT] scanner). Methods: Thirty plaster models were scanned with a 3Shape laser scanner and with a Flash CT scanner. Two examiners performed measurements on plaster models by using digital calipers and on digital models by using Ortho Analyzer (3Shape) and Digimodel® (OrthoProof) software programs. Forty-two measurements, including tooth diameter, crown height, overjet, overbite, intercanine and intermolar distances, and sagittal relationship, were obtained. Results: Statistically significant differences were not found between the plaster and digital model measurements (ANOVA); however, some discrepancies were clinically relevant. Plaster and digital model measurements made using the two scanning methods showed high intraclass coefficient correlation values and acceptable 95% limits of agreement in the Bland-Altman analysis. The software used did not influence the accuracy of measurements. Conclusions: Digital models generated from plaster casts by using laser and CT scanning and measured using two different software programs are accurate, and the measurements are reliable. Therefore, both fabrication methods and software could be used interchangeably.

A STUDY FOR THERMAL CONDUCTIVITY OF IRRADIATED CAVITY (와동내에 조사된 열의 전도양상에 관한 연구)

  • Baik, Byeong-Ju;Kim, Jae-Gon;Hur, Sun;Lee, Du-Cheol;Yun, Hyun-Du
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.583-597
    • /
    • 1998
  • The purpose of this study was to evaluate temperature change occurred in enamel, dentin and pulp due to the heat from cavity prepration with laser. We made three models had different cavity depth: cavity depth of model A was 3.52mm, model B was 2.32mm, model C was 1.16mm. We irradiated cavity base with thermal capacity of $30J,100J,300J/cm^2s$ during few seconds and studied the change of temperature in tooth during 10 seconds, and estimated change of thermal capacity by different irradiated site and exposure time. At $300J/cm^2$ irradiation for 2 seconds, the temperature of irradiated surface was elevated fast according to irradiated thermal energy during 1 second. In proportion to continuous exposure time, temperature elevated slowly. The surface temperature was $1370^{\circ}C$. After discontinue of thermal irradiation, the heat of irradiated surface was diffused in dentin and pulp and the greatest temperature was made. The greatest temperature was disappeared within 10 seconds The greatest temperature of the inner part of model brought about very severe change by different depth. Temperature in pulp was raised by the greater irradiated energy density and exposure time.

  • PDF

Analysis of the Transmission Error of Spur Gears Depending on the Finite Element Analysis Condition (스퍼 기어의 유한요소해석 조건에 따른 전달 오차 경향성 분석)

  • Jaeseung Kim;Jonghyeon Sohn;Min-Geun Kim;Geunho Lee;Suchul Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.121-130
    • /
    • 2023
  • Finite element analysis is widely used to predict the structural stability and tooth contact performance of gears. This study focused on the effect of finite element modeling conditions of a spur gear on the simulation result and the model simplification. The gear body and teeth, teeth width, configuration of mesh, frictional coefficient, and simulation time interval (gear mesh cycle division) were selected for model simplification for gear analysis. The static transmission error during a single-gear mesh cycle was calculated to represent the performance of the gear, and the elapsed time was measured as a simplification factor. Contact stress distribution was also checked. The differences in maximum transmission error and elapsed time depending on the model simplification methods were analyzed. After all simplification methods were estimated, an optimal combination of the methods was defined, and the result was compared with that of the most detailed modeling methods.

Analysis of Needs for Clinical Dental Hygienist's Performances Using Borich Needs Assessment and the Locus for Focus Model

  • Yang-Keum Han;An-Na Yeo
    • Journal of dental hygiene science
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • Background: This study aimed to identify the present level and needs of clinical dental hygienists and to present the Borich needs assessment and the locus for focus model as integrated priorities. Methods: The participants of this study were dental hygienists working in dental clinics (hospitals). The final data of the 194 participants were analyzed using frequency analysis and a paired sample t-test. To analyze the need for clinical dental hygienists to perform work, the Borich priority determination formula was used. The x-y plane consisting of four quadrants was used to analyze the need using the locus for focus model, which helps to determine the priority while showing visual effects. Results: "Scaling" was the highest required level for clinical dental hygienists, and "panorama taking" was the highest present level. The priorities of educational needs were systematically and visually derived from dental hygienists who were currently working through the Borich needs assessment and the locus for focus model for each task performed in the clinical field. Through the priorities of these two models, a total of 13 items appeared in the common high-level area; "oral health care (disability)," "oral health care (systemic disease)," "applying a rubber dam," "professional mechanical tooth cleaning," "root planing," "taking vital signs," "medication counseling," "wire cutting," "removing cement after removing band/bracket," "delivering bracket," "preparing mini-screw implantation," "dental insurance claim," and "patient reception." Conclusion: Based on the results, the department of dental hygiene should maintain and improve the standardized clinical practice curriculum and clinical dental hygienists' practical skills and contribute to the realization of the legal scope of dental hygienists, reflecting the requirements of clinical fields.

Analysis of vibration characterization of a multi-stage planetary gear transmission system containing faults

  • Hao Dong;Yue Bi;Bing-Xing Ren;Zhen-Bin Liu;Yue, Li
    • Structural Engineering and Mechanics
    • /
    • v.88 no.4
    • /
    • pp.389-403
    • /
    • 2023
  • In order to explore the influence of tooth root cracks on the dynamic characteristics of multi-stage planetary gear transmission systems, a concentrated parameter method was used to construct a nonlinear dynamic model of the system with 30-DOF in bending and torsion, taking into account factors such as crack depth, length, angle, error, time-varying meshing stiffness (TVMS), and damping. In the model, the energy method was used to establish a TVMS model with cracks, and the influence of cracks on the TVMS of the system was studied. By using the Runge- Kutta method to calculate the differential equations of system dynamics, a series of system vibration diagrams containing cracks were obtained, and the influence of different crack parameters on the vibration of the system was analyzed. And vibration testing experiments were conducted on the system with planetary gear cracks. The results show that when the gear contains cracks, the TVMS of the system will decrease, and as the cracks intensify, the TVMS will decrease. When cracks appear on the II-stage planetary gear, the system will experience impact effects with intervals of rotation cycles of the II-stage planetary gear. There will be obvious sidebands near the meshing frequency doubling, and the vibration trajectory of the gear will also become disordered. These situations will become more and more obvious as the degree of cracks intensifies. Through experiments, the theoretical results are in good agreement with experimental results, verifying the correctness of the theoretical model. This provides a theoretical basis for fault diagnosis and reliability research of the system.

A study of the arch length discrepancy and the diagnostic analysis (치열궁내 공간 부조화와 진단적 평가에 관한 연구)

  • Ryu, Young-Kyu;Ahn, Kwang-Seok
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.1-11
    • /
    • 2004
  • Predicting the arch length discrepancy by simply comparing the available arch perimeter with tooth materials is merely a 2-dimensional analysis of the teeth movement. However, the real teeth movement takes place 3-dimensionally and is affected by various factors such as, the arch fen the curve of Spee and the axis of the incisors. The purpose of this study is to clarify the relationship between the decrease in the arch perimeter and the horizontal positional change of the incisors after extraction of the 1st bicuspids, for more analytic evaluation of the arch length discrepancy at pre-treatment model analysis stage. In addition to that to evaluate the effect of the curve of Spee, teeth axis to the basal plane, and the incisional crowding to the treatment outcome. All patients were treated at the department of orthodontics, dental hospital, Yonsei university. Inclusion criteria for patients selection were as follows. $\cdot$ Angle classification I malocclusion with bialveolar protrusion $\cdot$ Extraction of 4 1st bicuspids $\cdot$ No tooth anomaly or prosthesis $\cdot$ No abnormal attrition $\cdot$ No ectopically erupted teeth $\cdot$ Angle classification I canine and molar relationship $\cdot$ Less than 3mm of crowding Model analysis of the above patients was performed and the following conclusions were obtained. 1. When the intercanine distance was maintained, the available space for the distal movement of the mandibular incisors after the extraction of the 4 1st bicuspids was larger than the space provided by the extraction of the 4 1st bicuspids. However the difference was less than 1mm. The more tapered the anterior arch form, the larger the difference. 2. Compared to the situation in which the intercanine distance was maintained, when the intercanine distance was expanded to meet the width of the Posterior teeth, the incisors could move about 3mm more distally. 3. The positional difference of the incisal tip was insignificant whether the central incisors were moved by tipping or bodily movement. 4. When the anterior crowding was solved without changing the intercanine distance, the larger the anterior arch length was, the more the anterior movement of the incisors. 5. When the curve of Spee was levelled, the increase in the arch perimeter was less than half of the deepest curve of Spee.

The establishment of orthodontic web server multimedia database system for continuing education (임상교정 교육용 멀티미디어 데이터베이스 웹서버 구축에 관한 연구)

  • Park, Jae-Woo;Lee, Jong-Ki;Chang, Young-Il;Nahm, Dong-Suk;Kim, Myung-Ki;Yang, Won-Sik;Kim, Tae-Woo;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.245-260
    • /
    • 2000
  • The Objective of this research was to construct the multimedia database system that was necessary for the education of the practitioners and the students. To establish this system, there were technical problems as follows 1) The processing of the images, 2) The rapid processing of the information with the computer network, 3) The development of diagnosis tools, 4) The technique to establish the database system, 5) The link between the database system and the internet, and 6) The method to educate through many cases. The analysis for diagnosis and treatment planning were provided as two parts : model analysis and cephalometric analysis. As a model analysis, arch length discrepancy and Bolton tooth ratio were provided for the part of patient information. Cephalometric analyses were provided in the part of initial diagnosis. The Cephalometric analysis ver 2.0 and the PowerCeph pro 3.3.5 were used to show Tweed, Steiner and Jarabak analysis. In the main part, Kim's analysis and some measurements were added. In the post-treatment or retention part, we show the superimposition of the cephalometrics with which you can find the effectiveness of the various orthodontic treatment The address of this home page is "http://damis.snu.ac.kr/orthodontics"

  • PDF

A COMPARATIVE STUDY OF BOND STRENGTH OF RECYCLED BRACKETS (재생 브라켓의 전단접착강도에 관한 비교 연구)

  • Shur, Cheong-Hoon;Choi, Eun-Ah
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.641-657
    • /
    • 1998
  • This study was undertaken to compare the bond strength and the fracture site of new and recycled brackets according to the base design. 252 sound premolars extracted for orthodontic treatment were collected and Type I, Type II, Type III brackets were divided into four groups by recycling method Each bracket was then bonded to an extracted premolar. Instron Universal Testing Machine(model W) was used to measure the shear bond strength, and the surface of the recycled brackets were viewed in SEM For the analysis of the results, one way ANOVA and Scheffe's multiple range test was executed using the SPSSWIN program. 1. The shear bond strength showed statistically significant difference according to the bracket base design(p<0.001). Type III bracket(round indentation base, micro-etched) showed the highest bond strength, Type I bracket(foil-mesh base) was second, and Type II bracket(grooved integral base, micro-etched) was last. 2. The effect of recycling on the bond strength was different according to bracket type. The shear bond strength of Type I, Type II brackets showed the smallist reduction when treated for 1 minute in Big Jane(p<0.05), but the shear bond strength of Type III brackets showed no statistically significant difference according to recycling method(p>0.05). 3. In Type I, Type II brackets, frequent fracture site was bracket-resin interface, but in Type III brackets, about half of the resin was retained on the tooth surface frequently. 4. The shear bond strength was highest when about half of the resin was retained on the tooth surface(p<0.05). 5. The resin remnant on the bracket base after recycling had no effect on the shear bond strength.

  • PDF

Influence of the length and location of implants on distal extension removable partial dentures: finite element analysis (후방연장 가철성 국소의치에서 임플란트의 길이와 위치가 응력분산에 미치는 영향)

  • Kim, Jin-Hee;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.186-194
    • /
    • 2015
  • Purpose: To evaluate the effects of implant location and length on stress distribution and displacement in osseointegrated-implants that were associated with mandibular distal extension removable partial dentures (DERPD). Materials and Methods: A sagittally cut model with the #33, #34 teeth and a removable partial denture of the left mandible was used. Seven models were designed with NX 9.0. Models A, B, C had implants with lengths of 11, 6, 4 mm, respectively, under the denture base of the #37 artificial tooth. Models D, E, F had implants with lengths of 11, 6, 4 mm, respectively, under the denture base of the #36 artificial tooth. Model G did not have any implants. Axial force (250 N) was loaded on #36 central fossa. The finite element analysis was performed with MSC Nastran. Von Mises stress maps were plotted to visualize the results. Results: The models of #37 implant placement showed much lower stress concentration on the surrounding bone of the implant compared with #36. The #36 implant position tended to reduce displacement more than #37. Conclusion: When an IARPD is designed, the distal positioning of implant placement has more advantages in the edentulous bone of DERPD on the prognosis of short implants and the stress distribution of edentulous alveolar bone. Using implants with longer lengths are important for stress distribution. However, Additional studies are necessary of the effects of length on implant survival.

Accuracy of interocclusal record established by different occlusal scans (교합스캔의 이용 방식에 따른 교합면간기록의 정확성)

  • Minjee Kang;Cheong-Hee Lee;Kyu-Bok Lee;So-Yeun Kim;Du-Hyeong Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.142-148
    • /
    • 2024
  • Purpose: The purpose of this study was to investigate the accuracy of digital mounting with occlusal scans in the interocclusal record for a full-mouth fixed prosthetic treatment condition. Materials and Methods: The entire maxillary teeth were prepared in a dentiform model and attached to an articulator in maximum intercuspation. Temporary crowns were fabricated and occlusion was adjusted. After scanning the arch with tooth preparation, digital mounting was performed using an occlusion scan of the anterior or posterior teeth areas. The accuracy of the positioned jaw relation was evaluated three-dimensionally through positional deviation and angular error of the occlusal plane. Afterwards, the same procedure was repeated on the partially edentulous model to evaluate the accuracy of digital interocclusal record. Kruskal-Wallis test and Mann-Whitney U test were used for statistical analysis, and the significance level was set at 0.05. Results: There was no significant difference in the positional error at the center of the arch in the digitally established jaw relation depending on the scan area used and remaining tooth conditions (P = 0.53). The angular error of the occlusal plane was larger when the anterior teeth were used as the overlapping area, and a smaller error value was observed when both posterior teeth were used as the overlapping area (P < 0.001). Conclusion: The use of bilateral posterior occlusal scans is recommended when digitally mounting the jaw relation established with temporary teeth during full-mouth fixed prosthetic treatment.