• Title/Summary/Keyword: Tooth development

Search Result 601, Processing Time 0.033 seconds

Development of the High Power Turbo Blower Gear (터보블로워용 증속기어 개발)

  • Jeon, Eon-Chan;Lee, Woo-Hyun;Lee, Kwon-Hee;Park, Young-Chul;Sung, Jang-Hyun;Kim, Young-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.32-37
    • /
    • 2011
  • This study developed Gear Automatic Design Program that users with the basic knowledge about mechanical engineering can easily model spur gears and helical gears. The Gear Automatic Design Program used Visual LISP which is an user program based on Auto CAD and made it model the gears with involute tooth by the exact mathematic definition. Also, to verify these, the reliability was secured by comparing it with a gear generated in commercial software. And we will develop nitrocarburising process and solve problems which had been caused of SCM440's dimensional changing.

Prosthodontic management of worn dentition in pediatric patient with complete overlay dentures: a case report

  • Kumar, Prince;Rastogi, Jyoti;Jain, Chandni;Singh, Harkanwal Preet
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.239-242
    • /
    • 2012
  • Overlay complete dentures are simple, reversible and economical treatment modality for patients with congenital or acquired disorders that severely affect the tooth development. It satisfies both the esthetic and functional demands where the extraction of teeth is not generally indicated. In pediatric patients, the overlay dentures establish a relatively stable occlusion that improves patient's tolerance to the future treatment procedures for worn dentition. This clinical report highlights the imperative need of appropriate treatment strategy and application of maxillary and mandibular overlay dentures in a pediatric patient who suffered from congenitally mutilated and worn dentition.

A study on the mechanical properties of TiN/DLC based functionally graded coatings

  • Song, Young-Sik;Kim, J.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.59-59
    • /
    • 2003
  • In recent, various functional coatings on artificial tooth implants have been conducted to enhance the bonding strength between implants and bones. Despite of these efforts, some previous reports argued that an adhesion strength between titanium implant and the final coatings like hydroxyapatite(HA) is weaker than the strength between coating and bone. In order to increase the adhesion force between the final coating and implant surface, TiN/DLC based functionally graded coating, which has higher mechanical strength than the titanium implant, was applied as a middle layer between titanium implant and final coating. Particularly we finally coated a biocompatible hydroxyapatite film on the DLC layer and examined the mechanical properties. As a result, TiN/DLC based functionally graded coating showed the higher adhesion strength compared with hydroxyapatite single layer coating on the titanium implant.

  • PDF

Smart Toothbrush System Development Using Auto Tooth brushing Position Detection (자동 위치 검출을 이용한 지능형 칫솔 시스템 개발)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Kim, Dong-Jun;Yun, Tae-Ho;Yang, Heui-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1908-1909
    • /
    • 2007
  • The design of an intelligent toothbrush, capable of monitoring brushing motion, orientation through the grip axis, during toothbrushing is described. Inappropriate Toothbrushing styles, even in adults, sometimes cause dental problems, cavities, gingivitis, etc. This smart system provides user to monitor his or her brushing pattern using accelerometer and magnetic sensors for evaluation of toothbrushing style. Directional information of toothbrush with respect to earth's magnetic field and activity data were measured by a miniaturized low-power micro- controller, MSP430 and transmitted to personal computer by 2.4GHz radio transmitter, nRF2401. A personal computer provides an on-line display of activity and orientation measurements during toothbrushing. The signal trace is then analyzed to extract clinically relevant measurement. This preliminary study showed that the proposed monitoring system was conceived to aid dental care personnel in patient education and instruction in oral hygiene regarding brushing style.

  • PDF

Development of Automatic Support Structure Generation System for Effective Building of Stereolithographic Parts (광조형물의 효율적 성형을 위한 지지대 자동 생성 시스템 개발)

  • 최홍태;배용환;이석희
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.7
    • /
    • pp.7-17
    • /
    • 1998
  • Stereolithography is a process used to rapidly produce stereolithographic parts directly from three dimensional CAD models. However design methodologies to create components to be built by stereolithography are different from those required by conventional machining processes. As a typical case in point, the support structures are required to support a component at build stage, but are later removed once building and curing are complete. These structures are used to anchor the component to the platform and to prevent sagging or distortion. This paper deals with the Support Map data structure prepared to find the appropriate regions of supports. Interferences between supports and parts, and support structure themselves as well, are checked and thus the system are searching the statically stable regions to remove the surplus support structures. Cross shaped tooth profiles are designed for easy eliminating the support structures.

  • PDF

Development of the Hydraulic Gear Pump for an Elevator (엘리베이터용 기어펌프 개발)

  • Jeong, Seok-Hoon
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.117-124
    • /
    • 2011
  • A gear pump is a type of pump that displaces a volume of fluid by physical or mechanical action, or positive displacement pump. Power is applied to one of the gears and transmitted to a second driven gear via meshing teeth. This paper describes the hydraulic gear pump for an elevator. In gear pump, since geometrically special forms of gear tooth, 'Pulsations' is always caused in the delivery pressure and quantity. In other words, it is found that the number of delivery pressure pulsation per each revolution is always equal to that of the gear-teeth of the gear, which is coincident with the pulsation of the ideal delivery quantity. Some experimental results are given to verify the effectiveness of the developed pump.

Application of CAD-CAM technology to surgery-first orthognathic approach (디지털 기술을 이용한 선수술 악교정치료)

  • Kim, Yoon-Ji;Gil, Byung-Gyu;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.622-630
    • /
    • 2018
  • For successful surgery-first approach, accurate prediction of skeletal and dental changes following orthognathic surgery is essential. With recent development of digital technology using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, attempts to provide more predictable orthodontic/orthognathic treatment have been made through 3D virtual surgery and digital tooth setup. A clinical protocol for the surgery-first orthognathic approach using virtual surgery is proposed. A case of skeletal Class III patient with facial asymmetry treated by the surgery-first approach using digital setup and virtual surgery is presented. Advantages and limitations of applying CAD/CAM technology to orthognathic surgery are discussed.

  • PDF

Treatment including orthognathic surgery of a patient with Hypohidrotic ectodermal dysplasia with cleft palate: A Clinical report (구개열을동반한저한성외배엽형성이상환자의 악교정수술을포함한치료: A Clinical report)

  • Kim, Jwa-Young;Park, In-Young;Song, Yun-Jung
    • The Journal of the Korean dental association
    • /
    • v.57 no.2
    • /
    • pp.93-99
    • /
    • 2019
  • Ectodermal dysplasia is a genetic disorder in which various clinical manifestations involve two or more of the differentiated tissues of the ectoderm. Facial deformity, which is frequently associated with ectodermal dysplasia, appears in the form of cleft lip or cleft palate, especially in the middle facial area.Cleft and tooth defects result in decreased alveolar bone development.This leads to severe skeletal incongruity. Facial features include frontal protrusion, malar bone hypoplasia, flat nose, mandibular prominence and long lower facial height. This clinical report presents treatment including orthognathic surgery of a patient with Hypohidrotic Ectodermal dysplasia with cleft palate.

  • PDF

Applications of Optical Imaging System in Dentistry

  • Eom, Joo Beom;Park, Anjin
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • Optical-based imaging technology has high resolution and can assess images in real time. Numerous studies have been conducted for its application in the dental field. The current research introduces an oral camera that includes fluorescent imaging, a second study examining a 3D intraoral scanner applying a confocal method and a polarization structure that identifies the 3D image of a tooth, and finally, an optical coherence tomography technique. Using this technique, we introduce a new concept 3D oral scanner that simultaneously implements 3D structural imaging as well as images that diagnose the inside of teeth. With the development of light source technology and detector technology, various optical-based imaging technologies are expected to be applied in dentistry.

Development of AI-based 5-axis tooth processing machine monitoring system (AI 기반의 5축치아가공기 모니터링 시스템 개발)

  • Kim, Hong-youn;Kim, Seu-hong;Piao, Hai-lian
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.753-755
    • /
    • 2021
  • 본 논문에서 기존의 치아가공기는 회전하는 모터를 사용하여 구성하였으나 이러한 모터는 정밀도, 반복정밀도가 50um 이하로 가공물 가공시에 치기공사나 치과의사가 사람에 맞추어 다시 작업을 해야하는 불편함과 시간적, 작업자의 피로도를 높일수 있는데 이러한 모터에 스크류나 밸트를 연결하여 선형적으로 움직일 수 있는 리니어모듈과 리니어모터를 적용하게되면 20um수준의 고정밀의 위치제어가 가능한 5축 치아가공기를 만들 수 있었다. 또한 MEMS센서를 이용하여 스핀들의 상태를 모니터링 하고 임계값을 지정하여 이상 신호 발생시 모터를 멈추어 위험상황에 대해서 인공지능기법을 이용하여 정지하거나 관리자에게 알림을 주어 효과적으로 5축치아가공기를 운영할 수 있도록 하였다.