• Title/Summary/Keyword: Tooth crack

Search Result 50, Processing Time 0.03 seconds

A Study on Crack Initiation Measurement of Carburized Gear Tooth by Acoustic Emission (침탄치차의 AE법에 의한 크랙발생의 계측에 관한 연구)

  • 류성기
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.11-16
    • /
    • 1994
  • Acoustic emission technique is applied to the fatigue crack initiation in a carburized gear tooth. Acoustic emission test performed on carburized gear and three-point bending test equal to carburized gear hardness. The marked acoustic emission are detected at the early stage of crack initiation measured by a crack gauge and the final stage just before the tooth failure. The estimated acoustic emission energy rate are characteristic of the measured acoustic emission.

  • PDF

Early Diagnosis and Proper Treatment of Cracked tooth (Cracked tooth (금이 간 치아)의 조기 진단 및 적절한 치료)

  • Kim, Sin-Young
    • The Journal of the Korean dental association
    • /
    • v.57 no.7
    • /
    • pp.403-411
    • /
    • 2019
  • A cracked tooth is defined as an incomplete fracture initiated from the crown and extending subgingivally and usually directed mesiodistally. Cracked teeth were most frequently involved in mandibular and maxillary molars at the age of 50s. Cracks occurred mainly in nonbonded restorations such as gold and amalgam, and majority of cracks were found in intact teeth. A pulpal and periapical diagnosis is dependent on the extent of the crack and duration of the symptom. The pulp of a cracked tooth might become inflamed because of microleakage, which induces thermal sensitivity. Once the crack has extended and exposed the pulp, severe pulp and periapical pathosis will likely be present. In addition, the extended crack can cause a bony dehiscence with a resulting narrow and deep periodontal pocket. Therefore, early diagnosis of the cracked tooth and proper treatment planning are important for clinician.

  • PDF

Tooth fracture during or after dental treatment (임상가를 위한 특집 3 - 치료 중 혹은 치료 후에 발생하는 치아의 파절)

  • Roh, Byoung-Duck
    • The Journal of the Korean dental association
    • /
    • v.52 no.2
    • /
    • pp.75-84
    • /
    • 2014
  • During dental treatment, if a tooth were fractured suddenly by unnoticed tooth crack or vertical root fracture, it would be very embarrassing and frustrating experiences to dentists. But if it were once diagnosed as one of these teeth fracture, dentist should know about the etiology, course of fracture development, treatment modality to avoid argument with patient. In here cases and diagnostic skills, etiology and treatement methods of tooth fracture originated by internal stress and masticatory force were discussed to help dentists.

Effects of Shot Peening on Crack Growth Resistance in Carburized Gears (침탄치차의 쇼트피닝처리가 크랙진전억제에 미치는 영향)

  • 류성기;정인성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3227-3235
    • /
    • 1994
  • This paper deals with an evaluation of the residual stress due to shot peening induced in a carburized gear tooth and its application to the fatigue crack propagation problem. A practical method is proposed on the basis of the assumption that the residual stress is caused by the difference of volume expansion in the case and the core, and the influence of both the reduction of retained austenite and the strain due to shot peening are considered. The evaluated residual stress is close to the measured stress, though the surface stress is rather overestimated. The stress intensity factor is computed by the influence function method, and it is shown that the factor is decreased by the residual stress in shot peened gear tooth. The shot peening is fairly effective to the reduction of fatigue crack growth rate. The crack propagation is simulated and the resistance due to shot peening is quantitatively demonstrated and discussed.

Development of Diagnostic Device for the Tooth Crack Using Transmitted Light (투과 광을 이용한 치아 균열 진단기 개발)

  • Yang, Jeong Su;Seo, Hyo-Gi;Lee, Joon-Seok;Choi, Keum Yeon;Cho, Jin-Hyoung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.317-320
    • /
    • 2016
  • In order to acquire clear images capable of diagnosing cracked tooth by light transmission, the optical properties of LED light source were examined. Based on the results, the prototype which basically consisted of LED light source, bandpass filter and commercial compact camera module was designed and manufactured. The wavelength and optical power of the LED in the prototype were 850 nm and 7 mW/Sr, respectively. In evaluation of the prototype using microscope, the observation of the crack with width of above $17{\mu}m$ was possible. In addition, image analysis to obtain shape information on the observed tooth cracks was carried out.

Automatic detection of tooth cracks in optical coherence tomography images

  • Kim, Jun-Min;Kang, Se-Ryong;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.41-50
    • /
    • 2017
  • Purpose: The aims of the present study were to compare the image quality and visibility of tooth cracks between conventional methods and swept-source optical coherence tomography (SS-OCT) and to develop an automatic detection technique for tooth cracks by SS-OCT imaging. Methods: We evaluated SS-OCT with a near-infrared wavelength centered at 1,310 nm over a spectral bandwidth of 100 nm at a rate of 50 kHz as a new diagnostic tool for the detection of tooth cracks. The reliability of the SS-OCT images was verified by comparing the crack lines with those detected using conventional methods. After performing preprocessing of the obtained SS-OCT images to emphasize cracks, an algorithm was developed and verified to detect tooth cracks automatically. Results: The detection capability of SS-OCT was superior or comparable to that of trans-illumination, which did not discriminate among the cracks according to depth. Other conventional methods for the detection of tooth cracks did not sense initial cracks with a width of less than $100{\mu}m$. However, SS-OCT detected cracks of all sizes, ranging from craze lines to split teeth, and the crack lines were automatically detected in images using the Hough transform. Conclusions: We were able to distinguish structural cracks, craze lines, and split lines in tooth cracks using SS-OCT images, and to automatically detect the position of various cracks in the OCT images. Therefore, the detection capability of SS-OCT images provides a useful diagnostic tool for cracked tooth syndrome.

EFFICIENCY OF ULTRASONIC ROOT-END RETROGRADE CAVITY PREPARATION AND ITS INFLUENCE ON TOOTH STRUCTURE (초음파기구의 치근단 역충전와동형성 효율 및 치질에의 영향)

  • Lee, Jae-Whan;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.546-559
    • /
    • 1997
  • The purposes of this study were to evaluate the efficiency of cavity preparation and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with ultrasonics. 91 distobuccal root-ends of extracted human maxillary first molars were cut by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw, retrocavities were prepared using a slow-speed no. 2 round bur as controls, and stainless steel ultrasonic tips of power settings of 1 through 10 as experimentals. Time consumed and the number of strokes used for the cavity preparation were measured and evaluated, and the incidence of tooth cracks was observed under a stereomicroscope. The results were as follows : For the retrograde cavity preparation, time and number of strokes used were decreased as the ultrasonic power setting increased (p<0.001). High power setting of ultrasonics induced significantly more tooth cracks than did the slow-speed bur or low- and medium power setting of ultrasonics (p<0.05). Teeth with previous crack induced significantly more tooth cracks than those without previous one when high power setting of ultrasonics were used for the retrograde cavity preparation (p<0.001). Teeth with initial apical canal size of no. 10 induced significantly more crack than did those with size of no. 15 when low power setting of ultrasonics were used for the retrograde cavity preparation (p<0.05).

  • PDF

THE INCREASE OF ENAMEL CRACK IN DEBONDING TEETH (Debonding에 의한 법랑질 Crack의 증가)

  • Yeom, Jeong-Bae;Rhee, Byung-Tae
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.85-91
    • /
    • 1987
  • The aim of this study was to clarify whether bonding/debonding procedure will affect the occurance of enamel crack. The frequency of enamel crack was compared between before-bonding and after-debonding on 200 human extracted teeth. Each facial surface of the tooth was divided in 9 fragments. A presence of crack, which was classified by its direction as vertical, horizontal and oblique crack, was surveyed in each fragment. Number of all cracks in facial surface was 1355 at before-bonding, and 1605 at after-debonding, so it revealed significant increase rate of $18.5\%$, but compared by fragment, cracks were significantly Increased in OC, OD, CC and GC fragments. All kinds of cracks were significantly increased, especially increase rate of oblique crack reached $54.9\%$. The increase rate of cracks was not superior at any fragment or region, but some evidence was seen in CC fragment. Judging from the above, increase of crack is unavoidable with bonding/debonding procedures.

  • PDF

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.