• Title/Summary/Keyword: Tooth Surface

Search Result 877, Processing Time 0.025 seconds

A 3-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE SUPPORTING TISSUES OF REMOVABLE PARTIAL DENTURES WITH VARIOUS RETAINER DESIGNS (국소의치 유지장치의 설계변화에 따른 지지조직의 3차원적 유한요소법 응력분석)

  • Kim, Ki-Sook;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.413-439
    • /
    • 1995
  • The purpose of this study was to evaluate the stress distribution developed in the supporting structures by mandibular distal extension removable partial dentures with 2 different direct retainer designs and with or without indirect retainer and abutment splinting. The examined direct retainers on the second bicuspid abutment tooth were Akers clasp and RPA clasp, the indirect retainer was located on the mesial fossa of the first bicuspid, and the first and second bicuspid were splinted in case of tooth splinting. Total 8 cases were compared and analyzed with 3-dimensional finite element method. 150N were applied vertically on the artificial teeth of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows : 1. The forces transmitted to the abutment tooth were primarily from the occlusal rests. 2. The abutment tooth was displaced distally when the force was applied. The compressive stress was observed at the distal root surface of the abutment tooth and the tensile stress, at the mesial root surface. 3. The denture base was displaced posteriorly and inferiorly when the force was applied. At the more distal portion of the denture base, the greater displacement was observed.And the anterior portion of the major connector was displaced superiorly. 4. The occlusal rest placed on the distal part of the abutment tooth tended to tip the tooth more posteriorly than did one on the mesial part of that tooth. 5. Severe superior displacement was observed at the anterior portion of the major connector in case of removable partial dentures without indirect retainer. 6. In case of tooth-splinting, the stress was distributed through all the root surface of both abuments. In case of no tooth-splinting, the stress was concentrated on the distal root surface of the primary abutment.

  • PDF

An Investigation on the Method of Tooth Modification for Noise Suppression of Gear Transmission (기어 변속기의 소음저감을 위한 치형수정 설정방법에 관한 고찰)

  • Bae, M.H.;Park, N.G.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.243-251
    • /
    • 1998
  • A method of establishing the tooth modification for gear transmission of vehicles to reduce gear whine noise, caused by tooth impact phenomenon of mating gear, is introduced. The major causes of tooth impact are due to the deflections of gear teeth and shafts of transmission with the loaded condition including various kinds of manufacturing errors. The theoretical shape of tooth surface to avoid tooth impact is derived by the amount of elastic deformation of gear teeth and shaft and overall manufacturing error of machine tool. The surface function is converted with respect to the conventional commercial data usually communicated to the gear inspection system. The proposed method is applied to the gearbox of four wheel drive vehicle and shows the gear whine noise decreased to the 8 dB in the sound level.

  • PDF

The effect of tooth brushing and thermal cycling on a luster change of ceromers finished with different methods

  • Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.336-347
    • /
    • 2000
  • Statement of problem. Luster loss in esthetic anterior ceromer restoration can occur and can be related with rough surface texture. Understanding durability of surface finishing methods like polishing and surface coating have critical importance. Purpose. This study evaluated the effect of tooth brushing and thermal cycling on surface luster of 3 ceromer systems (Artglass, Targis, Sculpture) treated with different surface finishing methods. Material and methods. Seventy-two samples were prepared: 12 for control group Z100, 12 for Artglass, 24 for Targis, and 24 for Sculpture. Half of the Targis and Sculpture were polished according to the manufacturer's recommendation. The rest of the samples were coated with staining and glazing solution for Targis and Sculpture, respectively. All specimens were subjected to 10,000 cycles between $5^{\circ}C\;and\;55^{\circ}C$ with 30 seconds dwell time. Tooth brushing abrasion tests were performed in a customized tooth brushing machine with 500g back and forth for 20,000 cycle. Luster comparisons were based on grading after direct observation, and light reflection area was measured with Image analysis software. Results. All materials showed an decrease in luster grade after thermal cycling and tooth brushing. The post-tooth brushing results revealed that the glazed Sculpture had greater mean luster grade than did any other groups. While, the stained Targis group showed greatest changes after tooth brushing (p < 0.05), polished Targis and Sculpture did not show significant changes. However, glazed Sculpture showed discretely fallen out glaze resin. Conclusion. From the results of this study, all of the ceromer specimens were much glossy than control composite group after tooth brushing. coatings used for Targis and Sculpture had not durability for long term use.

  • PDF

Parametric surface and properties defined on parallelogrammic domain

  • Fan, Shuqian;Zou, Jinsong;Shi, Mingquan
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.1
    • /
    • pp.27-36
    • /
    • 2014
  • Similar to the essential components of many mechanical systems, the geometrical properties of the teeth of spiral bevel gears greatly influence the kinematic and dynamic behaviors of mechanical systems. Logarithmic spiral bevel gears show a unique advantage in transmission due to their constant spiral angle property. However, a mathematical model suitable for accurate digital modeling, differential geometrical characteristics, and related contact analysis methods for tooth surfaces have not been deeply investigated, since such gears are not convenient in traditional cutting manufacturing in the gear industry. Accurate mathematical modeling of the tooth surface geometry for logarithmic spiral bevel gears is developed in this study, based on the basic gearing kinematics and spherical involute geometry along with the tangent planes geometry; actually, the tooth surface is a parametric surface defined on a parallelogrammic domain. Equivalence proof of the tooth surface geometry is then given in order to greatly simplify the mathematical model. As major factors affecting the lubrication, surface fatigue, contact stress, wear, and manufacturability of gear teeth, the differential geometrical characteristics of the tooth surface are summarized using classical fundamental forms. By using the geometrical properties mentioned, manufacturability (and its limitation in logarithmic spiral bevel gears) is analyzed using precision forging and multiaxis freeform milling, rather than classical cradle-type machine tool based milling or hobbing. Geometry and manufacturability analysis results show that logarithmic spiral gears have many application advantages, but many urgent issues such as contact tooth analysis for precision plastic forming and multiaxis freeform milling also need to be solved in a further study.

Experimental Investigation on the Serration Process (돌기성형공정에 관한 실험적 연구)

  • Koo, H.S.;Park, Y.S.;Jang, D.H.
    • Transactions of Materials Processing
    • /
    • v.17 no.3
    • /
    • pp.203-209
    • /
    • 2008
  • In this paper, experimental investigation has been performed to analyze the forming process of toothed or serrated sheets, which is used as strap engaging surface of the seal to secure together overlapping portions of steel or plastic strapping ligature. Serration formed on the strap engaging surface of the seal prevent from relative slipping between overlapping ligatures after closing the seal. The geometry of tooth on the strap engaging surface is directly related to the quality of securing overlapping ligatures together. Inclined indentation followed by scratching operation has been proposed and applied to the experiments. Punch entry and face angles are selected as process variables to see the influence of these variables on the tooth geometry. Five different punch entry angles have been applied to experiments and three different punch face angles have been selected for each case of punch entry angle. Clay is selected as model material for experiments. Experimental results are summarized in terms of tooth height, tooth width, and aspect ratio such as tooth height to width ratio, respectively.

SURFACE DEGRADATION OF GALLIUM-ALLOYS DURING TOOTH BRUSHING IN VITRO

  • Lee, Seok-Hyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.309-315
    • /
    • 2003
  • When the exposure surface of restoration is brushed with various toothpaste in the mouth, wear or undesirable surface deposit of restoration can occur. Surface change of gallium alloys according to brushing and toothpaste may directly affect oral hygiene. The aim of this study was to evaluate the surface alterations of Gallium alloys during tooth brushing with different prophylactic agents. Two gallium-alloys and an amalgam as a control were investigated. Without and with brushing were applied with three kinds of prophylactic agents on the sample for 0, 1, 5, 10, 60 and 360 minutes. At each time interval, surface roughness was recorded by a profilometer and some pictures were taken by a SEM. All results were analyzed by the one-way ANOVA, followed by Tukey multiple comparisons and the simple linear regression analysis. The results indicate that gallium alloys are more susceptible to surface degradation during tooth brushing than amalgam with respect to the specific prophylactic agent used.

The Study for Estimation of the Surface Temperature Rise in Spur Gear Tooth (Spur Gear 치면의 표면상승온도 예측에 관한 연구)

  • 김희진;구영필;조용주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.331-337
    • /
    • 2001
  • A numerical simulation of the temperature rise for sliding surface in dry contact is based on Jaegers formula combined with a calculated heat input. A gear tooth temperature analysis was performed. The pressure distribution has the Hertzian pressure distribution on the heat source. The heat partition factor is calculated along ling of action. A Temperature distribution of tooth surface is calculated about before and after profile modification. A Temperature of addendum and deddendum in modified gear have reduced.

  • PDF

Tooth bleaching effect by light activation on the tooth surface and intra-pulpal temperature: an in vitro study (광활성 유무가 치아미백과 치아표면 및 치수 내 온도에 미치는 영향)

  • Shim, Youn-Soo;Woo, Hee-Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.4
    • /
    • pp.585-591
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate of the color change, tooth surface and intra-pulpal temperature of tooth bleaching by light activation Methods : Forty-eight extracted bovine teeth were immersed into a tea solution for 24 hours. The specimens were randomly divided into four groups(n=15):(G1) 15% HP + without light activation, (G2) 15% HP + light activation, (G3) 25% HP + without light activation, (G4) 25% HP + light activation. All specimens were bleached for 15 minutes three times. The spectrophotometer (CM-2600d, Konica Minolta, Osaka, Japan) was used including before bleaching, immediately after bleaching, 1 week, 1 and 3 months after the end of bleaching. The temperature rise were measured in the pulpal chamber and tooth surface with a digital thermocouple thermometer(Termopar Digital Multimeter, Tektronix DMM916, USA). Between the tested time points, the specimens were stored in distilled water. The data were analyzed by ANOVA, t-test and Tukey's post hoc test set at 0.05. Results : There was no significant color change by the use of light after the bleaching treatment(p>0.05). The dental bleaching treatments of teeth with 15% HP and 25% HP did not seem to be more effective when light source was used. There was no difference in color stability between groups within three month(p>0.05). There was an increase in tooth surface and pulp temperature, but it was not sufficient to cause damage to the pulp. Conclusions :The use of light activation has no obvious effective impact on the tooth bleaching effect.

AN EXPERIMENTAL STUDY ON THE TOOTH ROOT RESORPTION FOR DIGITAL RADIOGRAPHY (디지털 방사선 촬영술을 이용한 치근 흡수 판독에 관한 실험적 연구)

  • Oh Phill-Gyo;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.375-387
    • /
    • 1995
  • The purpose of this study was to quantitatively evaluated experimental tooth root resorption for digital radiography. For this study, experimentally three root sites were used, and radiograms were taken with standardized apparatus. Digital imaging system were consisted of NEC PC-980l(computer), TRINITRON(monitor), SONY XC-711 CCD camera. The display monitor had a resolution of 512X512 pixels. The obtained results were as follows: 1. In the difference of the four X-ray film of the contrast correction, the contrast difference was one gray scale variation at mean value. 2. Viewing of the view box of the periapical radiographs, experimental tooth root resorption of the periapical area of the first premolar, middle of mesial surface of the first molar mesial root, middle of lingual surface of the first molar distal root were recognized by increased diameter. 3. On the analysis by histogram, the periapical area of the first premolar, the middle of mesial surface of the first molar mesial root were each recognized tooth root resorption of the 5,6,7 pixel, 2,4,5 pixel by increased diameter. 4. On the analysis by histogram, the middle of lingual surface of the first molar distal root was each recognized tooth root resorption of the none, 3,6 pixel by increased diameter.

  • PDF

Influence of the adjacent periodontium and inter-implant distance on bone resorption around non-submerged implants;A retrospective clinical and radiographic study (인접 치주조직과 임플란트간 거리가 임플란트 주변 골흡수에 미치는 영향;임상 및 방사선사진 검사에 의한 후향적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.535-541
    • /
    • 2004
  • The aims of the present study are firstly to investigate the amount of bone loss around non-submerged implants placed in the posterior region and secondly to investigate the relationship between inter-implant and implant-tooth distance and peri-implant bone loss. Thirty-one subjects with 60 implants were selected consecutively from the implant patient pool at the department of Chonbuk National University Hospital. To be included in the study subject, the implant should have been functioned more than 6 months after loading. Inter-implant and implant-tooth distance, distance between implant shoulder and the first bone contact with the implant(DIB) were measured from the scanning image of the radiograph of each implant. The result showed that; 1. inter-implant distance has a statistically significant relationship with DIB in Pearson correlation analysis. 2. the DIB at the implant facing surface of the implant was greater than that of tooth facing surface of the implant. Within limitation of this study, it is suggested to place an implant not too closely to adjacent implants, and the presence of a tooth adjacent to an implant may keep the level of tooth-facing surface of the implant. Further studies with a prospective design are needed to elucidate the relationship between bone changes and various dimensions around implants.