• 제목/요약/키워드: Tool Setting

검색결과 437건 처리시간 0.029초

Proposed Message Transit Buffer Management Model for Nodes in Vehicular Delay-Tolerant Network

  • Gballou Yao, Theophile;Kimou Kouadio, Prosper;Tiecoura, Yves;Toure Kidjegbo, Augustin
    • International Journal of Computer Science & Network Security
    • /
    • 제23권1호
    • /
    • pp.153-163
    • /
    • 2023
  • This study is situated in the context of intelligent transport systems, where in-vehicle devices assist drivers to avoid accidents and therefore improve road safety. The vehicles present in a given area form an ad' hoc network of vehicles called vehicular ad' hoc network. In this type of network, the nodes are mobile vehicles and the messages exchanged are messages to warn about obstacles that may hinder the correct driving. Node mobilities make it impossible for inter-node communication to be end-to-end. Recognizing this characteristic has led to delay-tolerant vehicular networks. Embedded devices have small buffers (memory) to hold messages that a node needs to transmit when no other node is within its visibility range for transmission. The performance of a vehicular delay-tolerant network is closely tied to the successful management of the nodes' transit buffer. In this paper, we propose a message transit buffer management model for nodes in vehicular delay tolerant networks. This model consists in setting up, on the one hand, a policy of dropping messages from the buffer when the buffer is full and must receive a new message. This drop policy is based on the concept of intermediate node to destination, queues and priority class of service. It is also based on the properties of the message (size, weight, number of hops, number of replications, remaining time-to-live, etc.). On the other hand, the model defines the policy for selecting the message to be transmitted. The proposed model was evaluated with the ONE opportunistic network simulator based on a 4000m x 4000m area of downtown Bouaké in Côte d'Ivoire. The map data were imported using the Open Street Map tool. The results obtained show that our model improves the delivery ratio of security alert messages, reduces their delivery delay and network overload compared to the existing model. This improvement in communication within a network of vehicles can contribute to the improvement of road safety.

Anesthetic efficacy in vital asymptomatic teeth using different local anesthetics: a systematic review with network meta-analysis

  • Amy Kia Cheen Liew;Yi-Chun Yeh ;Dalia Abdullah ;Yu-Kang Tu
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.41.1-41.23
    • /
    • 2021
  • Objectives: This study aimed to evaluate the efficacy of various local anesthesia (LA) in vital asymptomatic teeth. Materials and Methods: Randomized controlled trials comparing pulpal anesthesia of various LA on vital asymptomatic teeth were included in this review. Searches were conducted in the Cochrane CENTRAL, MEDLINE (via PubMed), EMBASE, ClinicalTrials.gov, Google Scholar and 3 field-specific journals from inception to May 3, 2019. Study selection, data extraction, and risk of bias assessment using Cochrane Risk of Bias Tool were done by 2 independent reviewers in duplicate. Network meta-analysis (NMA) was performed within the frequentist setting using STATA 15.0. The LA was ranked, and the surface under the cumulative ranking (SUCRA) line was plotted. The confidence of the NMA estimates was assessed using the CINeMA web application. Results: The literature search yielded 1,678 potentially eligible reports, but only 42 were included in this review. For maxillary buccal infiltration, articaine 4% with epinephrine 1:100,000 was more efficacious than lidocaine 2% with epinephrine 1:100,000 (odds ratio, 2.11; 95% confidence interval, 1.14-3.89). For mandibular buccal infiltration, articaine 4% with epinephrine 1:100,000 was more efficacious than various lidocaine solutions. The SUCRA ranking was highest for articaine 4% with epinephrine when used as maxillary and mandibular buccal infiltrations, and lidocaine 2% with epinephrine 1:80,000 when used as inferior alveolar nerve block. Inconsistency and imprecision were detected in some of the NMA estimates. Conclusions: Articaine 4% with epinephrine is superior when maxillary or mandibular infiltration is required in vital asymptomatic teeth.

Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications

  • Akinori Hata;Yoshitake Yamada;Rie Tanaka;Mizuki Nishino;Tomoyuki Hida;Takuya Hino;Masako Ueyama;Masahiro Yanagawa;Takeshi Kamitani;Atsuko Kurosaki;Shigeru Sanada;Masahiro Jinzaki;Kousei Ishigami;Noriyuki Tomiyama;Hiroshi Honda;Shoji Kudoh;Hiroto Hatabu
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.634-651
    • /
    • 2021
  • Dynamic X-ray (DXR) is a functional imaging technique that uses sequential images obtained by a flat-panel detector (FPD). This article aims to describe the mechanism of DXR and the analysis methods used as well as review the clinical evidence for its use. DXR analyzes dynamic changes on the basis of X-ray translucency and can be used for analysis of diaphragmatic kinetics, ventilation, and lung perfusion. It offers many advantages such as a high temporal resolution and flexibility in body positioning. Many clinical studies have reported the feasibility of DXR and its characteristic findings in pulmonary diseases. DXR may serve as an alternative to pulmonary function tests in patients requiring contact inhibition, including patients with suspected or confirmed coronavirus disease 2019 or other infectious diseases. Thus, DXR has a great potential to play an important role in the clinical setting. Further investigations are needed to utilize DXR more effectively and to establish it as a valuable diagnostic tool.

Volume Control using Gesture Recognition System

  • Shreyansh Gupta;Samyak Barnwal
    • International Journal of Computer Science & Network Security
    • /
    • 제24권6호
    • /
    • pp.161-170
    • /
    • 2024
  • With the technological advances, the humans have made so much progress in the ease of living and now incorporating the use of sight, motion, sound, speech etc. for various application and software controls. In this paper, we have explored the project in which gestures plays a very significant role in the project. The topic of gesture control which has been researched a lot and is just getting evolved every day. We see the usage of computer vision in this project. The main objective that we achieved in this project is controlling the computer settings with hand gestures using computer vision. In this project we are creating a module which acts a volume controlling program in which we use hand gestures to control the computer system volume. We have included the use of OpenCV. This module is used in the implementation of hand gestures in computer controls. The module in execution uses the web camera of the computer to record the images or videos and then processes them to find the needed information and then based on the input, performs the action on the volume settings if that computer. The program has the functionality of increasing and decreasing the volume of the computer. The setup needed for the program execution is a web camera to record the input images and videos which will be given by the user. The program will perform gesture recognition with the help of OpenCV and python and its libraries and them it will recognize or identify the specified human gestures and use them to perform or carry out the changes in the device setting. The objective is to adjust the volume of a computer device without the need for physical interaction using a mouse or keyboard. OpenCV, a widely utilized tool for image processing and computer vision applications in this domain, enjoys extensive popularity. The OpenCV community consists of over 47,000 individuals, and as of a survey conducted in 2020, the estimated number of downloads exceeds 18 million.

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

PLAYMAKER2, 전문가 시스템을 이용한 동해 울릉분지 남부 신생대 후기 퇴적층의 퇴적환경 해석 (Interpretation of depositional setting and sedimentary facies of the late Cenozoic sediments in the southern Ulleung Basin margin, East Sea(Sea of Japan), by an expert system, PLAYMAKER2)

  • 정대교
    • 한국석유지질학회지
    • /
    • 제6권1_2
    • /
    • pp.20-24
    • /
    • 1998
  • 전문가 시스템(expert system)은 충분한 지식과 경험을 가지고 있는 한 분야의 전문가가 실제로 문제에 접근 해결해 나가는 방식대로 전산 시스템을 구성하여 이러한 시스템을 통해 컴퓨터가 대신 문제를 해결하도록 제작된 인공지능 방식의 한 소프트웨어이다. 이번 연구에서는 퇴적층의 퇴적상과 퇴적환경 분석을 위해 미국 사우스 캐롤라이나 대학에서 본래 1990년에 개발되었던 PLAYMAKER의 지식베이스의 일부를 새로 수정 보완하여 제작한 PLAYMAKER2를 활용하여 퇴적층의 퇴적상과 퇴적환경을 분석하였다. 연구대상은 동해 울릉분지 남서부 제 VI-1 광구에 분포하는 최대 층후 10,000 m에 달하는 신생대 후기 퇴적층으로서, 이 곳의 퇴적층은 크게 상·하부 두 부분-마이오세충과 플라이오-플라이스토세층-으로 구분된다. PLAYMAKER2에 의해 분석되어 신뢰값으로 표시된 신생대 후기 퇴적층에 대한 퇴적환경과 퇴적상해석 결과를 요약해 보면, 마이오세층의 퇴적환경은 사면: $57.4\%$, 연안: $21.4\%$, 대양저: $10.1\%$의 순이고, 퇴적상은 해저 선상지: $35.7\%$, 대륙사면: $26.3\%$, 삼각주: $16.1\%$, 심해저 평원: $6.1\%$, 대륙붕: $3.2\%$, 대륙붕단: $1.4\%$ 순이다. 또한 플라이오-플라이스토세층에 대한 PALYMAKER2의 해석 결과는 퇴적환경은 사면: $59.0\%$, 연안: $22.8\%$, 대양저: $7.0\%$의 순이고, 퇴적상은 삼각주: $24.1\%$, 대륙사면: $22.2\%$, 해저 선상지: $17.3\%$, 대륙붕: $7.0\%$, 심해저 평원: $4.8\%$, 대륙붕단: $2.6\%$ 순이다. PLAYMAKER2에 의한 마이오세층과 플라이오-플라이스토세층에 대한 퇴적환경과 퇴적상 해석결과와 기존 연구자들에 의한 고전적인 퇴적상 해석 결과를 비교해 보면 두 퇴적층 모두 큰 차이를 보이지 않는데 이는 PLAYMAKER2전문가 시스템이 비교적 양호하게 퇴적층의 퇴적환경과 퇴적상을 해석할 수 있음을 보여주는 것으로 평가된다. 다만 PLAYMAKER2가 보다 신뢰할 만한 퇴적환경 해석을 위한 전문가 시스템으로 구축되기 위해서는 향후 많은 퇴적학 전문가들이 추가로 참여하여 기존 규칙들을 재검증하고 새로운 규칙들을 첨가함으로써 보디 세련된 지식베이스를 개발하여야 할 것으로 판단된다.

  • PDF

사고실험 - 상상의 작용과 한도에 대해 (Thought Experiments: on the Working Imagination and its Limitation)

  • 황희숙
    • 철학연구
    • /
    • 제146권
    • /
    • pp.307-328
    • /
    • 2018
  • 과학을 비롯한 여러 학문분야에서 사고실험(thought experiments)의 사용은 오랜 역사가 있다. 특히 현대 분석철학의 문헌들 속에서 빈번하게 등장하는 사고실험들은 반사실적인 상황에 대한 시나리오로 구성되는데, 여기서 직관과 상상이 상식적 지식과 결합하여 작동하고 있는 것을 볼 수 있다. 사고실험은 논변 구성자에게 필요한 결론을 유도해 내기 위한 개념 분석적 장치다. 그런데 과연 철학의 사고실험들이 지식의 생산에 기여하며 불가피하고도 유익한 것인지에 대해서는 의문의 여지가 있다. 특정한 사고실험이 제시되었을 때, 이를 대면하고 있는 우리가 그 논변의 유도방향에 대해 어떤 무력감이나 속임수의 느낌을 받는다면, 이는 주목해야할 현상일 것이다. 필자는 이에, 사고실험의 적절성 문제를 유명한 사고실험 세 가지 즉, 톰슨의 '병든 바이올리니스트', 퍼트남의 '통속의 뇌', 설의 '중국어 방' 사고실험을 놓고 논의한다. 사고실험에 대해 느끼는 불편함의 원인은 무엇일까? '상상적인 사고실험'들은 실재에 대한 판단 및 정보가 틈새를 보이는 상황에서 구축되어 제시되는 바, 가상적 상황에 대한 논변이다. 그런데 사고실험에서 유관한 배경적 조건들에 대해 부적절하거나 불확실한 바가 있거나, 임의적으로 기술된 요소가 있다면 그 사고실험은 의구심을 불러일으킬 수 있다. 사고실험의 추론이 실제 철학적 문제들에 어떤 적실성과 유효성을 가질 수 있는지를 따져보아야 한다. 호프스태터가 보여주듯이 사고실험의 시뮬레이션 속에 포함된 여러 요소들의 설정을 바꿈으로써 즉 '노브 설정(knob setting)'을 달리함으로써 구성자의 결론과는 다른 결론이 나올 수도 있다. 이렇듯 사고실험의 시나리오에는 철학자의 상상과 이론적 편향이 들어있으며, 그 상상이라는 도구는 오직 제한적으로만 사용되어야 한다는 것이 이 글의 주장이다.

위절제술환자의 간호실무표준 사용이 간호의 질에 미치는 영향 (A study of the impact of using a nursing care standards on the quality of nursing care in gastrectomy patients)

  • 우영자
    • 간호행정학회지
    • /
    • 제2권2호
    • /
    • pp.97-107
    • /
    • 1996
  • Nursing standards determine the type and extent of services that are delivered to the patients and define quality care and communicate the institution's expectations of care. Thus, taking the standard of care and incorporating it into a welldefined indicator of excellent patient care becomes one of the first activities in setting up the nursing service's quality assurance process. The purpose of this study was to determine the impact of using a nursing care standards for the quality of nursing care in gastrectomy patients. The subjects were composed of fourty-two under going gastrectomy patients with stomach cancer in general surgery nursing care unit of K University Hospital in Pusan. The data was collected from January 3 to April 13,1996. The subjects were divided into a control group - those admitted from Jan.3 to Feb.12 and an experimental group those admitted from Feb.18 to April 13. The instruments used for this study were a nursing care standards in gastrectomy patients developed by the investigator and an evaluation tool for the quality of nursing care in abdominal surgery patients developed by Byoung-Sook Lee in 1995. The data was analized by means of chi-square test, t-test and Cronbach-alpha test with the SAS System. The result was as follows : The hypothesis, that scores of the quality of nursing care in the experimental group would be higher than that of the control group. was supported(t=-6.12, p=0.00). The detailed results of each standards of evaluation tool were as follows : The mean score of the experimental group was significantly higher than that of the control group in audit standard 1:'Collection of basic data of the patients', (t=-3.76, p=0.00). The mean score of the experimental group was significantly higher than that of the control group in audit standard 2 : 'Defining nursing diagnoses(or nursing problems)', (t= (-), p= (-) ). The mean score of the experimental group was significantly higher than that of the control group in audit standard 3:'Estabilishment of nursing care plan according to nursing diagnoses(or nursing problems)',(t= (-), p= (-) ). The mean score of the experimental group was significantly higher than that of the control group in audit stndard 4:'Implimentation of nursing care plan', (t=-2.38, p=0.01). The mean score of the experimental group was significantly higher than that of the control group in audit standard 8 : 'Increase of the knowledge of health related to surgery',(t=-2.40, p=0.01). No significant differences between the mean scores of the experimental group and that of the control group in audit standard 5 : 'Recover and maintain of the physical function', audit standard 6:'Prevention of the post-operative complication', audit standard 7 : 'Decrease of discomfort caused by operation', and audit standard 9 : 'Patient satisfaction in nursing care' were found. The standards of evaluation tool were devided into two dimension. One was process dimension which contains four standards(audit standard 1 to 4), the other was outcome dimension which contains five standards(audit standard 5 to 9). The mean score of the experimental group was significantly higher than that of the control group in process dimension (t=-12.30, p=0.00), but no significant difference between the mean scores of the experimental group and that of the control group in outcome dimension was found. From these results, it is concluded that using a nursing care standards in gastrectomy patients promotes quality of nursing care and nursing care standards of various fields are necessary for effective nursing care.

  • PDF

인터벤션에서 Calibration Mode에 대한 오차율 비교 (Comparison on the Error Rates of Calibration Modes in Intervention)

  • 공창기;류영환
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.619-626
    • /
    • 2020
  • 이 연구의 목적은 경피적 혈관내 풍선 확장술이나 스텐트 삽입술에서 Balloon이나 Stent의 직경 및 길이를 예측 할 때 사용되는 정량적인 평가 도구인 Calibration Mode중 Catheter Calibration Mode, Auto Calibration Mode 그리고 Segment Calibration Mode에서의 오차율에 대해 알아보고자 하였다. Calibration의 정량적인 평가를 위해 정교하게 제작된 직경 × 길이(2 mm × 80 mm) Copper Wire와 5, 10, 15, 30, 40 mm의 Metal Ball을 이용하여 실험하였고, 아크릴 팬텀은 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, 200 mm로 하여 각각의 높이에서 혈관조영 촬영장치로 Subtraction 영상을 획득하여 장비 회사에서 제공하는 소프트웨어인 Stenosis Analysis Tools을 이용하여 측정하였다. Catheter Calibration Mode에서의 오차율을 평가하기 위한 방법으로 Copper Wire를 각각의 아크릴 팬텀위에 올려놓고 촬영하였으며, Copper Wire 직경 2 mm를 Catheter의 직경으로 Setting하였고, 길이 8 mm Copper Wire의 길이를 Multi-segments로 측정하여 분석한 결과 1.13 ~ 5.63%의 오차율이 나타났다. Auto Calibration Mode에서의 오차율을 평가하기 위한 방법으로 각각의 아크릴 팬텀을 높이에서 아크릴 높이에 대한 수치를 입력하고, 8 mm Copper Wire의 길이를 Multi-segments 측정하여 분석한 결과 0 ~ 0.26%의 오차율이 나타났다. Segment Calibration Mode에서의 오차율을 평가하기 위한 방법으로 테이블 바닥에 있는 각각의 Metal Ball을 각각 Calibration하고, 각각의 아크릴 팬텀 위에 올려 있는 8 mm Copper Wire의 길이를 측정하여 아크릴 팬텀 높이 변화에 대한 8 mm Copper Wire 길이를 Mutli-segments 측정하여 분석한 결과 1.05 ~ 19.04%의 오차율이 나타났다. 그리고 Auto Calibration Mode에서 OID 변화에 대한 실험은 아크릴 팬텀의 높이는 100mm로 고정하고 OID만 450 mm ~ 600 mm로 변화를 하였을때 오차율은 0.13 ~ 0.38%로 나타났다. 결론적으로 소프트웨어에서 제공하는 정량적인 혈관의 치수평가를 하기 위한 이들 Calibration Mode 중 Auto Calibration Mode에서 높이 값을 입력하는 것이 오차율이 가장 적은 Calibration 방법임을 확인하였으며, Metal ball이나 기타 다른 물체를 이용하여 Calibration을 하기 위해서는 시술부위와 동등한 높이에 놓고 Calibration을 하는 방법이 오차율을 가장 줄일 수 있는 방법으로 사료된다.

반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소 (Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance)

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.581-588
    • /
    • 2019
  • 자기공명영상검사는 조직의 대조도 와 해상력이 우수하지만, 인공물이 발생 될 경우 진단에 영향을 주어 판독이 불가능한 영상을 생성하기도 한다. 치아에 삽입된 금속은 강자성체 또는 상자성체로 되어있는 경우가 대부분이며 자화율 차이로 인하여 기하학적 왜곡을 유발하여 영상진단에 저해되는 경우가 많으며 이를 저감시킬 필요가 있다. 이에 본 연구는 반자성 물질을 사용에 따른 금속 인공물 분석을 실시하고자 한다. 자성 물질로는 치아교정용 와이어와 브라켓인 스테인리스 스틸이 사용되었고 반자성 물질은 구리, 아연, 비스무트를 사용하였다. 검사장비는 1.5T, 3T가 사용되었으며 사용된 시퀀스는 SE, TSE, GE, EPI을 사용하여 측정하였다. 자체 제작된 팬텀을 물질은 균등한 신호를 위하여 아가로스 겔(10%)을 사용하였으며 인공물 유발 물질은 스테인리스 스틸은 팬텀의 정중앙에 위치시켜 검사하고 각 길이 10mm의 정 육면체 반자성 물질의 씌워 검사하였다. 인공물 측정은 Image J를 사용하여 순수한 팬텀 영상에서 자성물질을 포함한 영상을 감산하여 얻은 영상에서 Low Threshold 값을 10으로 설정 한 후 Wand tool을 사용하여 인공물 영역설정 후 면적을 구하였다. 스테인리스 스틸에서 발생한 금속 인공물은 반자성 물질 중 비스무트를 사용한 영상에서 금속 인공물이 가장 많이 감소하였으며 구리와 아연은 약간은 감소하지만, 그 정도의 차이는 크지 않다고 하겠다. 이러한 이유는 비스무트의 반자성 자화율이 가장 작아서 강자성체에서의 자화율을 가장 많이 상쇄하였기 때문이라고 생각된다. 1.5T 와 3T 모두에서 비스무트를 사용한 영상의 인공물이 가장 적게 나왔다. 시퀀스별 인공물 감소는 1.5T에서는 TSE에서 가장 많이 인공물이 감소하였으며 3T에서는 SE에서 가장 많은 인공물이 감소하였다. 따라서 반자성물질의 따른 인공물 변화의 결과는 자화율(${\chi}$)이 가장 낮은 비스무트를 사용한 영상에서 금속인공물이 기준인 Implant 인공물 보다 줄어든 양상을 보여 자화율이 낮은 물질일수록 금속 인공물이 줄어든다는 것을 알 수 있었으며, 기존 금속 인공물의 해결 방법의 단점으로 지적되어온 스캔 시간의 증가 등이 나타나지 않으면서도 인공물을 줄일 수 있는 방법으로 향후 치아 교정 물질뿐만 아니라 치아 보철물 전체에 대한 금속 인공물 저감에 관한 연구의 기초 자료로 사용될 것으로 사료된다.