• Title/Summary/Keyword: Toilet in School Buildings

Search Result 5, Processing Time 0.021 seconds

The Study on development of models of the Planning Toilet in School Buildings (학교화장실 계획의 최적화 모델개발 연구)

  • Lee, Sang Min;Kim, Sung Joong;Meang, Joon Ho
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.8 no.2
    • /
    • pp.40-50
    • /
    • 2009
  • The toilet in school building is one of most crucial elements for the recent changing face in school design, but the number of toilets and urinals in most school may not be sufficient to meet current needs, especially in the girl's toilet rooms. This study aims to suggest a guideline in designing the toilet in school buildings and propose the optimum area and development of models. The survey for this study is conducted through questionnaires collected and research from 9 schools in Seoul. The results of this study, it is suggested that the number of toilet facilities in school buildings be required by ratio of 0.5 toilets per a class and 1.1 urinal per a class for boy. In case of girls, it is suggested that ratio of 1.6 toilets per a class. Based on the result, it also propose various unit plans for each class block with space such as rest zone, green zone, powder zone etc.

  • PDF

The Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층 공동주택 국소배기용 입상덕트의 배기성능평가)

  • Kwon, Yong-Il;Kim, Ung-Yong;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.60-67
    • /
    • 2014
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

Study on Deriving Improvements through Analysis of BF Certification Evaluation Indicators for Parks and Park Facilities (공원 및 공원시설 BF인증 평가지표 분석을 통한 개선방향 도출 연구)

  • Kim, Mi Hye;Koo, Bonhak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.13-29
    • /
    • 2022
  • According to the revision of the Convenience Act for Persons with Disabilities, parks and park facilities where the first park development plan is established after December 4, 2021 are mandatory, and parks must be equipped with convenience facilities for the disabled. Hence, this study aims to derive the improvements of the park evaluation index by analyzing the park certification evaluation index, the building certification evaluation index of park facilities, and the evaluation reports of the current certification status cases. As a research method, first, the certification of parks and park facilities were compared and reviewed with the Park Green Act, and differences in the certification process and certification performance were compared and analyzed. Second, differences and common items were derived by analyzing barrier free (BF)-certification evaluation indicators for parks and buildings. Third, improvement plans were derived after analyzing differences and problems in 4 BF-certified parks and four building certification cases of park facilities in certified parks, focusing on the self-evaluation report and examination results. As a result of analyzing the park and building evaluation indicators, the items for which the evaluation purpose, evaluation method, and evaluation items were commonly applied to 7 access roads for each facility, 5 parking areas for the disabled, 2 guide facilities for information facilities, 14 in 5 categories of sanitation facilities, and 1 for other facilities. In the case of sanitation facilities, there is no case where it was evaluated as a park. If the park does not have an attached toilet, the park is certified as a building. Hence, it would be essential to establish the concept of an attached toilet and discuss the application of the evaluation index on the park sanitation facility. The score of buildings in parks and park facilities was lower than that of the self-evaluation results, and the certification grades of buildings declined in three cases. The items with the highest standard deviation were BF walking continuity for parks and the path to the main entrance among access roads for buildings. As a result of analyzing the park and building evaluation results of 19 common evaluation items except for sanitary facilities, the difference in the grades of the evaluation items for each case site except for one item appeared. Therefore, applying common detailed calculation criteria for items evaluated in common with parks and buildings is needed. Since sanitation facilities have no cases of park certification and are not certified as buildings, it is essential to establish the concept of attached toilets and discuss the application of park sanitation evaluation indicators. It is necessary to develop an evaluation index suitable for the characteristics of the park, such as adjusting the items that are not evaluated in parks and establishing an evaluation index considering the ones of parks. It expects that this study would be used as primary data for improving park certification indicators.

Application of Rainwater Harvesting System Reliability Model Based on Non-parametric Stochastic Daily Rainfall Generator to Haundae District of Busan (비모수적 추계학적 일 강우 발생기 기반의 빗물이용시설 신뢰도 평가모형의 부산광역시 해운대 신시가지 적용)

  • Choi, ChiHyun;Park, MooJong;Baek, ChunWoo;Kim, SangDan
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.634-645
    • /
    • 2011
  • A newly developed rainwater harvesting (RWH) system reliability model is evaluated for roof area of buildings in Haeundae District of Busan. RWH system is used to supply water for toilet flushing, back garden irrigation, and air cooling. This model is portable because it is based on a non-parametric precipitation generation algorithm using a markov chain. Precipitation occurrence is simulated using transition probabilities derived for each day of the year based on the historical probability of wet and dry day state changes. Precipitation amounts are selected from a matrix of historical values within a moving 30 day window that is centered on the target day. Then, the reliability of RWH system is determined for catchment area and tank volume ranges using synthetic precipitation data. As a result, the synthetic rainfall data well reproduced the characteristics of precipitation in Busan. Also the reliabilities of RWH system for each of demands were computed to high values. Furthermore, for study area using the RWH system, reduction efficiencies for rooftop runoff inputs to the sewer system and potable water demand are evaluated for 23%, 53%, respectively.