Journal of the korean academy of Pediatric Dentistry
/
v.34
no.4
/
pp.569-578
/
2007
This study was performed to compare the shear bond strength of self etching system and two bottle bonding system with or without laser preparation. Group I was prepared with high speed rotary instrument and $Prompt^{TM}$ L-$Pop^{TM}$, group II with Er:YAG laser and $Prompt^{TM}$ L-$Pop^{TM}$, group III with Er:YAG laser, 37% phosphoric acid and Single bond, group IV with Er:YAG laser and Single bond and group V with high speed, etching and Single bond. And also observation of the prepared and etched dentin surface were performed under scanning electro-microscope. The possibility of clinical application of laser preparation which might have an advantage to reduce pain for children with less unfavorable noise were evaluated. The results obtained are as follows; 1. Group V showed significantly higher bond strength than other groups. And group IV showed significantly lower bond strength than other groups. 2. There was no significant difference between group I and group III. 3. Group II showed significantly lower bond strength than group I, III, V, but showed significantly higher bond strength than group IV. 4. Under scanning electro-microscope, laser-preparated dentin surface showed high irregularity and no smear layer. The surface showed less irregularities and more exposed dentinal tubules with etching. Laser preparation has many advantages over conventional tooth preparation. But this method showed lower resin bonding strength. Laser preparated tooth surface differed from the conventionally preparated tooth surface. More researches are needed on suitable methods for laser preparated dentin surface.
Water-soluble crude polysaccharide (TM-1) prepared from the leaves of Teucrium viscidum var. miquelianum was fractionated into three polysaccharide fractions, TM-2, TM-3 and TM-4 by the addition of cetyltrimethylammonium bromide. The major polysaccharide fraction, TM-2, consisted of glucose, galactose, rhamnose, mannose, glucuronic acid and galacturonic acid, and all fractions contained galactose and glutose as the major neutral sugars. TM-4 showed the highest anti-complementary activity. When TM-4 was futher fractionated by anion exchange chromatography, TM4- II a and TM4-II b showed the most Potent anti-complementary activity. TM4- II a was composed mainly of galactose, arabinose and glucose in the molar ratios of 2.13 : 0.94 : 1.00 respectively, and contained a small amount of galacturonic acid and glucuronic acid.
Sunil, B.M.;Manjunatha, L.S.;Ravi, Lolitha;Yaragal, Subhash C.
Advances in concrete construction
/
v.3
no.1
/
pp.55-69
/
2015
Tailing Material (TM) and Fly Ash (FA) are obtained as waste products from the mining and thermal industries. Studies were carried out to explore the possibility of utilizing TM as a part replacement to fine aggregate and FA as a part replacement to cement, in concrete mixes. The effect of replacing fine aggregate by TM and cement by FA on the standard sized specimen for compressive strength, split tensile strength, and flexural strengths are evaluated in this study. The concrete mix of M40 grade was adopted with water cement ratio equal to 0.40. Concrete mix with 35% TM and 65% natural sand (TM35/S65) has shown superior performance in strength as against (TM0/S100, TM30/S70, TM40/S60, TM50/S50, and TM60/S40). For this composition, studies were performed to propose the optimal replacement of Ordinary Portland Cement (OPC) by FA (Replacement levels studied were 20%, 30%, 40% and 50%). Replacement level of 20% OPC by FA, has shown about 0-5% more compressive strength as against the control mix, for both 28 day and 56 days of water curing. Interestingly results of split tensile and flexural strengths for 20% OPC replaced by FA, have shown strengths equal to that of no replacement (control mix).
Journal of the korean academy of Pediatric Dentistry
/
v.30
no.4
/
pp.593-599
/
2003
The purposes of this study were to evaluate the microleakage of class V composite resin restorations utilizing the different curing lights, to assess the flowable resin, $Filtek^{TM}Flow$(3M Dental Products, USA) and composite resin, $Filtek^{TM}Z250$(3M Dental Products, USA) which need 20s curing time for halogen light could replace $Z100^{TM}$ Restorative(3M Dental Products, USA) for the microleakage, and to evaluate the effect of adhesive resin on marginal microleakage. Light curing units used in this study were conventional halogen light, XL3000(3M Dental Products, USA) and plasma arc light, Flipo(Lokki, France). Class V cavities were prepared and each cavity was filled with each composite resin. After being filled, the teeth were stored in distilled water, polished, thermocycled and soaked in 1% methylene blue solution. Following results were obtained from evaluation of the sectioned surface. 1. There was no statistically significant difference in microleakage of $Filtek^{TM}Flow$ and $Filk^{TM}Z250$ between two kinds of curing units(p>0.05). 2. Flowable resin, $Filtek^{TM}Flow$ showed more microleakage than Z100 and $Filtek^{TM}Z250$ regardless of curing units(p<0.05). 3. Adhesive resin reduced the microleakage of composite resin in both halogen light and plasma arc light(p<0.05).
Kim, Jou-Hwe;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
Journal of Dental Rehabilitation and Applied Science
/
v.31
no.2
/
pp.75-85
/
2015
Purpose: The purpose of this study is to evaluate which FRC-posts were more distinguishable from core. Materials and Methods: Nine extracted single-rooted mandibular premolars with similar lengths (${\pm}0.5 mm$) and widths (${\pm}0.5 mm$) were endodontically treated and obturated. One specimen which the three roots were embedded in a cold mounting resin was made. 3 specimens were made by this method. Post spaces were prepared for the following post system: FRC $Postec^{(R)}$ Plus, MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$$XRO^{(R)}$, $Snowpost^{(R)}$. After three different posts were placed in the roots of a specimen, each three specimens received a direct core build-up: $Luxacore^{(R)}$ Dual A3, $Luxacore^{(R)}$ Dual blue, $Filtek^{TM}$ Z350 A1E. Digital images were taken of the post and core with and without air-blowing. We asked to fifty dentists and fifty dental college students which post was more clearly discriminated from the core. Results: In surveys, when core was $Luxacore^{(R)}$ Dual blue, among three types of posts people more easily discriminated the $Snowpost^{(R)}$ from core. When core was $Luxacore^{(R)}$ Dual A3, among three types of posts people similarly more easily discriminated $Snowpost^{(R)}$ from core. When core was $Filtek^{TM}$ Z350 A1E, among three types of posts people more easily discriminated distinguished MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$$XRO^{(R)}$ post from core. People more easily distinguished MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$$XRO^{(R)}$ post from core when temperature was lowered by air-blowing. Conclusion: Ability to discriminate between FRC-post and core is different according to color contrast. MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$$XRO^{(R)}$ posts are more discriminable when temperature is lowered by air-blowing.
Journal of the korean academy of Pediatric Dentistry
/
v.43
no.4
/
pp.443-451
/
2016
Subjects of this study were : $FluoroDose^{(R)}$ (FD, Centrix Inc., USA), $Enamelast^{TM}$ (EL, Ultradent Product Inc., USA), $Clinpro^{TM}$ white varnish (CW, 3M ESPE, USA), $CavityShield^{TM}$ (CS, 3M ESPE, USA), V $varnish^{TM}$ (VV, Vericom, Korea), MI $varnish^{TM}$ (MI, GC, Japan). The amount of fluoride ion release was measured eight times during 168 hours to see change in accumulation with the course of time using a measuring instrument. And the remineralization rate was measured with Quantitative Light-induced Fluorescence (QLF). V $varnish^{TM}$ group and MI $varnish^{TM}$ group showed high remineralization rates with statistically significance while $CavityShield^{TM}$ group was the lowest rate of remineralization (p < 0.05). After that, several chosen samples were scanned through electron microscope (SEM). Demineralized enamel was observed as the number of enamel crystal was very small; enamel rods and crystals were highly protruding. Remineralized groups with fluoride varnishes show the decreasing tendency of the surface roughness compared to the demineralized enamel.
Journal of the korean academy of Pediatric Dentistry
/
v.30
no.1
/
pp.47-53
/
2003
This study evaluated the influence of chemomechanical caries removal agent $Carisolv^{TM}$(MediTeam, Sweden) for composite resin adhesion to sound human permanent and primary dentin. The buccal/labial surfaces of 80 permanent molars and 80 primary incisors were used. Four types of adhesives and one composite resin were used; AQ Bond(Sun Medical, Japan), Clearfil SE Bond(Kuraray, Japan), Single Bond(3M, USA), Scotchbond Multi-Purpose(3M, USA) and Z100(3M, USA). One drop of $Carisolv^{TM}$(MediTeam, Sweden) was pretreated on the dentin for 0 second(control) and 60 seconds. The specimens were thermocycled for 1,000 times in baths kept 5 degrees C and 55 degrees C with a 30 seconds dwell time. Shear bond strengths were tested and the data was statistically analyzed using one-way ANOVA with subsequent post hoc Scheffe test at p<0.05. $Carisolv^{TM}$ treatment significantly decreased the shear bond strength. Shear bond strength of permanent dentin was significantly higher than that of primary dentin. Clearfil SE Bond treatment groups showed the highest shear bond strength and AQ Bond treatment groups showed the lowest shear bond strength.
Journal of the korean academy of Pediatric Dentistry
/
v.40
no.4
/
pp.283-295
/
2013
In this study, researchers tried to find the effect, if any, of aging treatment to the specimens with three different dentin bonding agents using MicroCT. One, 5th generation - [Adper$^{TM}$ Single bond Plus] and two 6th generation [AdheSE$^{(R)}$, Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$] dentin bonding agents were used in this study. Specimens were divided into 4 groups according to aging treatment method used. Group I : control group, Group II : thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 60 seconds dwell time 5,000 times, Group III : aged as Group II and artificially brushed 20,000 times, Group IV : aged as Group III and were stored in artificial saliva for 6 months. With Single bond Plus, Group II showed more microleakage than Group I (p < 0.05). Group II and Group III showed more microleakage than Group IV (p < 0.05). There were no statistically significant differences among the groups using AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ (p > 0.05). Among Group I, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group II, there were no statistically significant differences (p > 0.05). Among Group III, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group IV, AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ showed more microleakage than Single bond Plus (p < 0.05).
Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
Journal of Chest Surgery
/
v.39
no.5
s.262
/
pp.354-358
/
2006
Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.
This paper presents a new 3D sound toolkit called $EVE-Sound^{TM}$ that consists of pre-processing tool for environment simplification preserving sound effect and 3D sound API for real-time rendering. It is designed so that it can allow users to interact with complex 3D virtual environments by audio-visual modalities. $EVE-Sound^{TM}$ toolkit would serve two different types of users: high-level programmers who need an easy-to-use sound API for developing realistic 3D audio-visually rendered applications, and the researchers in 3D sound field who need to experiment with or develop new algorithms while not wanting to re-write all the required code from scratch. An interactive virtual environment application is created with the sound engine constructed using $EVE-Sound^{TM}$ toolkit, and it shows the real-time audio-visual rendering performance and the applicability of proposed $EVE-Sound^{TM}$ for building interactive applications with complex 3D environments.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.