• Title/Summary/Keyword: Titanium substrate

Search Result 246, Processing Time 0.028 seconds

Surface Characteristics of Oxide Film Prepared on CP Ti and Ti-10Ta-10Nb Alloy by Anodizing (양극산화에 의해 CP Ti와 Ti-10Ta-10Nb 합금 표면에 형성된 산화 피막의 형상 및 표면 특성)

  • Kim, Hyun-Seung;Kee, Kwang-Min;Lee, Doh-Jae;Park, Sang-Won;Lee, Kyung-Ku
    • Korean Journal of Materials Research
    • /
    • v.17 no.1
    • /
    • pp.6-10
    • /
    • 2007
  • In the present study, we investigated the formation of self-organized nanostructure oxide layers on CP Ti and Ti-10Ta-10Nb alloy in an electrolyte of 1M phosphoric acid and 1.5 wt% Hydrofluoric acid. The morphology of oxide film on substrate was observed using scanning electron microscopy and transmission electron microscopy The surface roughness of titanium oxide film was analyzed by atomic force microscopy and the crystalline of specimen was investigated using X-ray diffractometer. The results of this study showed that well-aligned titanium oxide nanotubes are formed with diameter of approx. 100nm and length of approx. 500nm with CP Ti. However, it is clear that TiTaNb alloy highly irregular structure with various diameters. Transmission electron microscope investigations show that the specimens were confirmed as amorphous. Such titanium oxide nanotubes are expected a well-adhered bioacitive surface layer on titanium substrate for orthopedics and dental implants.

A Study on Kaolin and Titanium dioxide affecting Physical Properties of Electrocoating

  • Yang, Wonseog;Hwang, Woonsuk
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.203-208
    • /
    • 2013
  • The electrocoating for automotive bodies is pigmented with a mixture of titanium dioxide and kaolin. In this study, the effects of titanium dioxide and kaolin contents in coating on electrodeposition process, drying, and surface properties such as surface roughness, gloss, impact resistance and corrosion resistance were investigated. Titanium dioxide and kaolin in coating do not have a decisive effect on curing reaction during drying and corrosion resistance but on gloss, surface roughness, impact resistance and electrodeposition process of coating. According to its size and shape on coating surface, pigment contents increased during drying process. However, the contents of kaolin and $TiO_2$ in coating didn't affect the corrosion resistance on zinc phosphated substrate, and the curing properties.

Surface Characteristics and Biocompatibility of Titanium Coated with Dentin-derived Hydroxyapatite

  • Kim, Hae-Jin;Son, Mee-Kyung;Lee, Kyung-Ku;Lee, Bo-Ah;Kim, Young-Joon
    • International Journal of Oral Biology
    • /
    • v.37 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • The aim of this study was to evaluate surface characteristics and biological properties of the dentin -derived hydroxyapatite (HA) coating on titanium substrate. Dentinderived HA was obtained from extracted human teeth using a calcination method at $850^{\circ}C$. The commercially pure titanium (cp-Ti, ASTM Grade II) was used as a metallic substrate and a radio frequency magnetron sputtering method was employed as a coating method. Scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) were utilized to investigate the coating aspects and composition. Atomic forced microscopy (AFM) and a surface profiler were used to assess the surface morphology and roughness. Corrosion tests were performed in phosphate-buffered saline at a $36.5{\pm}1^{\circ}C$ in order to determine the corrosion behavior of the uncoated and coated specimens. The biocompatibility of dentin-derived HA coated specimens with fetal rat calvarial cells and human gingival fibroblasts was assessed by SEM and cell proliferation analysis. The results showed that the dentin-derived HA coatings appeared to cover thinly and homogeneously the surfaces without changing of the titanium substrate. The EDX analysis of this the coating surface indicated the presence of Ca and P elements. The mean surface roughness of cp-Ti and dentin-derived coating specimens was $0.27{\mu}m$ and, $1.7{\mu}m$, respectively. Corrosion tests indicated a stable passive film of the dentin-derived HA coating specimens. SEM observations of fetal rat calvarial cells and human fibroblast cells on coated surfaces showed that the cells proliferated and developed a network of dense interconnections. The cells on all specimens proliferated actively within the culture period, showing good cell viability. At day 1 and 3, dentin-derived coating specimens showed 89% and 93% cell viability, respectively, when normalized to cp-Ti specimens. These results suggest that dentin-derived HA coating using the RF magnetron sputtering method has good surface characteristics and biocompatibility.

Microstructure and Hardness of Titanium Aluminide/Carbide Composite Coatings Prepared by Reactive Spray Method (반응성 스프레이방법으로 제작한 티타늄 알루미나이드/탄화물 복합박막의 미세조직과 경도)

  • Han, Chang-Suk;Jin, Sung-Yooun
    • Korean Journal of Materials Research
    • /
    • v.30 no.7
    • /
    • pp.350-358
    • /
    • 2020
  • A variety of composite powders having different aluminum and carbon contents are prepared using various organic solvents having different amounts of carbon atoms in unit volume as ball milling agents for titanium and aluminum ball milling. The effects of substrate temperature and post-heat treatment on the texture and hardness of the coating are investigated by spraying with this reduced pressure plasma spray. The aluminum part of the composite powder evaporates during spraying, so that the film aluminum content is 30.9 mass%~37.4 mass% and the carbon content is 0.64 mass%~1.69 mass%. The main constituent phase of the coating formed on the water-cooled substrate is a non-planar α2 phase, obtained by supersaturated carbon regardless of the alloy composition. When these films are heat-treated at 1123 K, the main constituent phase becomes γ phase, and fine Ti2AlC precipitates to increase the film hardness. However, when heat treatment is performed at a higher temperature, the hardness is lowered. The main constitutional phase of the coating formed on the preheated substrate is an equilibrium gamma phase, and fine Ti2AlC precipitates. The hardness of this coating is much higher than the hardness of the coating in the sprayed state formed on the water-cooled substrate. When hot pressing is applied to the coating, the porosity decreases but hardness also decreases because Ti2AlC grows. The amount of Ti2AlC in the hot-pressed film is 4.9 vol% to 15.3 vol%, depending on the carbon content of the film.

Titanium nitride thin films for applications in thin film resistors

  • Cuong, Nguyen Duy;Kim, Dong-Jin;Kang, Byoung-Don;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.283-283
    • /
    • 2007
  • Titanium nitride thin films were deposited on $SiO_2$/Si substrate by rf-reactive magnetron sputtering. The structural and electrical properties of the films were investigated with various $N_2/(Ar+N_2)$ flow ratios (nitrogen/argon flow ratio). The resistivity as well as temperature coefficient of resistance (TCR) of the films strongly depends on phase structure. For the films deposited at nitrogen/argon flow ratio of below 5%, the resistivity increased with increasing nitrogen/argon flow ratios. However, the resistivity of the film deposited at nitrogen/argon flow ratio of 7% decreased drastically; it is even smaller than that of metal titanium nitride. A near-zero TCR value of approximately 9 ppm/K was observed for films deposited at nitrogen/argon flow ratio of 3%.

  • PDF

Chemical Binding States of Ti and O Elements in Anodic Ti Oxide Films (Ti 양극산화 피막에서 Ti 및 O원소의 화학결합 상태)

  • 유창우;오한준;이종호;장재명;지충수
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.6
    • /
    • pp.383-390
    • /
    • 2002
  • To investigate behaviors of Ti and O elements and microstructures of anodic titanium oxide films, the films were prepared by anodizing pure titanium in $H_2$S $O_4$, $H_3$P $O_4$, and $H_2O$$_2$ mixed solution at 180V. The microstructures and chemical states of the elements were analyzed using SEM, X-ray mapping, AFM, XRD, XPS (depth profile). The films formed on a titanium substrate showed porous layers which were composed of pore and wall, And with increasing anodizing time a hexagonal shape of cell structures were dominant and solace roughness increased. From the XRD result the structure of the Ti $O_2$ layer was anatase type of crystal on the whole. In the XPS spectra it was found that Ti and O were chemically binded in forms of Ti $O_2$, TiOH, $Ti_2$ $O_3$ at Ti 2p, and Ti $O_2$, $Ti_2$ $O_3$, $P_2$ $O_{5}$, S $O_4^{2-}$ at O ls respectively. Concentration of Ti $O_2$ decreased as the depth increased from the surface of the oxide film towards the substrate, but to the contrary concentrations of TiOH and $Ti_2$ $O_3$ increased.d.

Effect of Titanium Sulfate Addition on Crystal Growth of the Flaky α-Al2O3 (황산티타늄의 첨가가 판상 α-Al2O3의 결정성장에 미치는 영향)

  • Park, Byung-Ki;Cho, Sun-Mi;Lee, Jung-Min
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.5 s.276
    • /
    • pp.338-345
    • /
    • 2005
  • To prepare the complex gel of flux and pseudo-boehmite used in precursor of the flaky ${\alpha}-A1_2O_3$ crystal, aqueous solution of the mixture of sodium carbonate and sodium phosphate was added with stirring in aqueous solution of the mixture of sodium sulfate, potassium sulfate and titanium sulfate. The complex gel was dried at $110^{\circ}C$ and was crystallized above $1,050^{\circ}C$, and then the effect of the amount of titanium sulfate on size, morphology, thickness and crystal size distribution of the flaky ${\alpha}-A1_2O_3$ crystal was investigated. Addition of titanium sulfate was prevented the aggregation and generation of twin crystal, and had an effect on the crystal size and the thickness during crystal growth. When the amount of titanium sulfate was more than 6 g, particle size was decreased but was free from crystal twining and aggregation. On the other hand, when the amount of titanium sulfate was lower than 6 g, crystal size was increased but crystal twinning and aggregation were noticed.

Effect of Nitrogen Ion Implantation on Wear Behavior of Biocompatible Ti Implant (질소이온 주입이 생체적합성 티타늄 임플란트의 마모특성에 미치는 영향)

  • Byeon, Eung-Seon;Kim, Dong-Su;Lee, Gu-Hyeon;Jeong, Yong-Su
    • 연구논문집
    • /
    • s.30
    • /
    • pp.137-145
    • /
    • 2000
  • Since the concept of osseointegration was introduced, titanium and titanium-based alloy materials have been increasingly used for bone-anchored metal in oralmaxillofacial and orthopedic reconstruction. Successful osseointegration has been attributed to biocompatibility and surface condition of metal implant among other factors. Although titanium and titanium alloys have an excellent over the metal ion release and biocompatibility, considerable controversy has developed over the metal ion and wear debris in vivo and vitro. In this study, nitrogen ion implantation technique was used to improve the corrosion resistance and wear property of titanium materials, ultimately to enhance the tissue reaction to titanium implants As ion implantation energy was increased, projected range of nitrogen ion the Ti substrate was gradually increased. Under condition of constant ion energy. atomic concentration of nitrogen was also increased with ion doses. The friction in Hank's solution was increased with ion doses. The friction coefficient of ion implanted specimens in HanK's solution was increased from 0.39, 0.47 to 0.52, 0.65 respectively under high energy and ion dose conditions. As increasing ion energies and ion dose, amount of wear was reduced.

  • PDF

Study on the Composition Analysis and Electrical Properties of Chemical Vapor Deposited PbTiO3 Thin Film (화학증착법에 의한 PbTiO3박막의 조성분석 및 전기적성질에 관한 연구)

  • 이혜용;윤순길;김호기
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.5
    • /
    • pp.670-676
    • /
    • 1989
  • The PbTiO3 is well known materials having remarkable ferroelectric, piezoelectric, and pyroelectric properties. PbTiO3 thin films with a perovskite structure were successfully fabricated on titanium substrate by chemical vapor deposition. These films were characterized according to composition, crystal structure, and electrical properties. Semi-quantitative compositional analysis of the deposited films was made by Auger Electron Spectroscopy(AES). The PbTiO3 film deposited on titanium substrate at the deposition temperature 75$0^{\circ}C$, the Ti(C2H5O)4 fraction 0.15, and O2 partial pressure 0.06atm, has a columnar structure and grows with(001) preferred orientation, and has stoichiometric composition. A clear dielectric transition and offset in the dc conductivity near the transition temperature(48$0^{\circ}C$) were observed in the deposited lead titanate film.

  • PDF

Structural and Electrical Properties of Reactively Sputtered Titanium Nitride Films (DC 반응성 스퍼터링된 TiN 박막의 구조적 및 전기적 특성)

  • 류성용;오원욱;백수현;신두식;오재응;김영남;심태언;이종길
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.8
    • /
    • pp.49-55
    • /
    • 1992
  • We Have investigated the properties of the titanium nitrite films widely used in VLSI devices as diffusion barrier in Al-based metallization. TiN films were formed by reactive sputtering from Ti target in Ar-N$_2$ mixtures, varying deposition parameters such as N$_2$ partial pressure, substrate temperature, power, and total pressure. All the samples received the heat treatment at 45$0^{\circ}C$ for 30 min. The resulting films are characterized by mechanical stylus($\alpha$-step), x-ray diffraction(XRD), scanning electron microscopy(SEM), and four point probe method. The Tin film properties strongly depend on the deposition condition. The stoichiometry and Ti deposition rate are critically affected by nitrogen partial pressure, and the resistivity, in particular, is dependent on both the substrate temperature and sputtering power.

  • PDF