• Title/Summary/Keyword: Titanium screw

Search Result 176, Processing Time 0.021 seconds

In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants

  • Garcia-Roncero, Herminio;Caballe-Serrano, Jordi;Cano-Batalla, Jordi;Cabratosa-Termes, Josep;Figueras-Alvarez, Oscar
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.160-165
    • /
    • 2015
  • PURPOSE. In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous$^{(R)}$; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at $30^{\circ}$ in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.

EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS (Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가)

  • Park, Jee-Hyun;Hwang, Sun-Jung;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

Radioprotective role of amifostine on osteointegration of titanium implants in the tibia of rats

  • Nevra Aydemir Celep;Hulya Kara ;Elif Erbas;Elif Dogan
    • Journal of Veterinary Science
    • /
    • v.24 no.3
    • /
    • pp.35.1-35.10
    • /
    • 2023
  • Background: Titanium is the most widely used metal for bone integration, especially for cancer patients receiving ionizing radiation. This study aimed to investigate the amifostine administration that would reduce the effects of radiation on bone healing and osseointegration in rat models. Objectives: It is aimed that the application of amifostine in rats receiving radiotherapy treatment will reduce the negative effects of ionizing radiation on the bone. Methods: Thirty-five adult male Wistar rats were randomly divided into one healthy and four experimental groups. In three consecutive days, two experimental groups of rats (AMF-RT-IMP and RT-IMP) were exposed to radiation (15 Gy/3 fractions of 5 Gy each). Then the titanium implants were inserted into the left tibia. Before the radiotherapy process, a 200 mg/kg dose of amifostine (AMF) was administered to the rats in the AMF-IMP and AMF-RT-IMP groups. Twenty-eight days after the screw implant, all rats were sacrificed, and their blood samples and tibia bones were collected for analysis. Results: The results indicated an accelerated bone formation and a more rapid healing process in the screw implants in the AMF-IMP, AMF-RT-IMP, and AMF-RT groups than in the RT-IMP group. Also, bone-implant contact area measurement and inflammation decreased with amifostine treatment in the implants subjected to irradiation (p < 0.05). Conclusions: The results obtained in the present study suggested that amifostine prevents the losses of bone minerals, bone integrity, and implant position from ionizing-radiation when given before exposure.

Correction of Single Thoracic Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Comparison of Stainless Steel to Titanium Alloy Instruments (척추경 나사못 고정술을 이용한 단일 흉추 청소년기 특발성 척추 측만증의 치료: 스테인리스강과 티타늄 합금 기기의 비교)

  • Kim, Sung-Soo;Lim, Dong-Ju;Kim, Jung-Hoon;Choi, Byung-Wan;Kim, Hwi-Young;Lee, Jun-Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.141-149
    • /
    • 2019
  • Purpose: To compare the results of two different instruments made of stainless steel and titanium alloy for correction of single thoracic adolescent idiopathic scoliosis (AIS) using pedicle screw instrumentation. Materials and Methods: A total of 141 patients with single thoracic AIS treated with pedicle screw instrumentation and selective thoracic fusion were retrospectively reviewed after a follow-up of 2 years. The patients had a main thoracic curve of 40° to 75° and were divided into two groups based on instrument materials; S group (stainless steel, n=90) and T group (titanium alloy, n=51). The diameter of the stainless steel rod used was 7.0 mm while that of the titanium alloy rod was 6.35 mm or 6.0 mm. Standing long-cassette radiographic measurements including various coronal and sagittal parameters for the preoperative, early postoperative and 2-year postoperative followup were analyzed. There were no significant differences in the preoperative curve characteristics between the two groups. Results: In the S group, the preoperative main thoracic curve of 51.3°±8.4° was improved to 19.0°±7.6° (63.1% correction) and the lumbar curve of 32.3°±8.4° spontaneously decreased to 12.7°±8.2° (62.9% correction) at 2 years postoperatively. In the T group, the preoperative main thoracic curve of 49.5°±8.4° and the lumbar curve of 30.3°±8.9° was improved to 18.8°±7.4° (62.2% correction) and 11.3°±5.4° (63.3% correction), respectively. The corrections of coronal curves were not statistically different between the two groups (p>0.05). The thoracic kyphosis was changed from 16.8°±8.5° to 24.3°±6.1° in the S group and from 19.6°±11.2° to 26.6°±8.5° in the T group. There were no significant differences in the changes of sagittal curves, coronal and sagittal balances at the 2-year follow-up and the number of fused segments and used screws between the two groups (p>0.05). Conclusion: When conducting surgery for single thoracic AIS using pedicles screw instrumentation, two different instruments made of stainless steel and titanium alloy showed similar corrections for coronal and sagittal curves.

Titanium Mesh Cage for Anterior Stabilization in Tuberculous Spondylitis : Is It Safe?

  • Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Kim, Seung-Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.412-418
    • /
    • 2006
  • Objective : The safety of titanium metal cages in tuberculous spondylitis has not been investigated. We evaluated the outcome and complications of titanium mesh cages for reconstruction after thoracolumbar vertebrectomy in the tuberculous spondylitis. Methods : There were 17 patients with 18 operations on the tuberculous spondylitis in this study. Sixteen patients were operated with anterior corpectomy and reconstruction with titanium mesh cage followed by posterior transpedicular screw fixations on same day, two pateints were operated by either anterior or posterior approach only. After the affected vertebral body resection and pus drainage from the psoas muscle, titanium mesh cage, filled with morselized autogenous bone, was inserted. All the patients had antituberculosis medication for 18 months. The degree of kyphosis correction and the subsidence of cage were measured in the 15 patients available at a minimum of 2 years. Outcome was assessed with various cross-sectional outcome measures. Recurrent infection was identified by serial ESR[Erythrocyte Sedimentation Rate] and CRP[Cross Reactive Protein]. Results : There was no complication from the use of a titanium mesh cage. Recurrent infection was not detected in any case. Average preoperative of $9.2^{\circ}$ was reduced to $-2^{\circ}$ at immediate postoperative period, and on final follow up period kyphotic angle was measured to be $4.5^{\circ}$. Postoperatively, subsidence was detected in most patients especially at ambulation period, however further subsidence was prevented by the titanium mesh cage. Osseous union was identified in all cases at the final follow-up. Conclusion : The cylindrical mesh cage is a successful instrument in restoring and maintaining sagittal plane alignment without infection recurrence after vertebrectomy for tuberculous spondylitis.

Maxillary expansion with the memory screw: a preliminary investigation

  • Halicioglu, Koray;Kiki, Ali;Yavuz, Ibrahim
    • The korean journal of orthodontics
    • /
    • v.42 no.2
    • /
    • pp.73-79
    • /
    • 2012
  • Objective: The purpose of this study was to investigate the effects of a newly developed rapid maxillary expansion screw-the memory screw-over 6 months. Methods: Five subjects, aged between 11.7 and 13.75 years, were enrolled in this study. All subjects underwent placement of a maxillary expansion appliance containing superelastic nickel-titanium open-coil springs in its screw bed. The parents of the patients and/or the patients themselves were instructed to activate the expansion screw by 2 quarter-turns 3 times a day (morning, midday, and evening; 6 quarter-turns a day). The mean expansion period was $7.52{\pm}1.04$ days. Dentoskeletal effects of the procedure, including dentoalveolar inclination, were evaluated. Measurements of all the parameters were repeated after 6 months of retention in order to check for relapse. Results: Sella-Nasion-A point (SNA) and Sella-Nasion/Gonion-Menton angles increased, and Sella-Nasion-B point (SNB) angle decreased in all the subjects during the expansion phase. However, they approximated to the initial values at the end of 6 months. On the other hand, the increments in maxillary apical base (Mxr-Mxl) and intermolar widths was quite stable. As expected, some amount of dentoalveolar tipping was observed. Conclusions: The newly developed memory expansion screw offers advantages of both rapid and slow expansion procedures. It widens the midpalatal suture and expands the maxilla with relatively lighter forces and within a short time. In addition, the resultant increments in the maxillary apical base and intermolar width remained quite stable even aft er 6 months of retention.

Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants

  • Mohammed, Hnd Hadi;Lee, Jin-Han;Bae, Ji-Myung;Cho, Hye-Won
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.62-69
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION. Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.

Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System (TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석)

  • Kang, Kwan-Su;Jung, Tae-Gon;Yang, Jae-Woong;Woo, Su-Heon;Park, Tea-Hyun;Jeong, Yong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.3
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.

MECHANICAL PROPERTIES OF TIN COATED FILM WITH VARIOUS COATING THICKNESS ON TITANIUM ALLOY (타이타늄 합금에 다양한 두께로 코팅된 TiN 피막의 기계적 성질)

  • Lee, Jae-Yun;Oh, Dong-Joon;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.675-686
    • /
    • 2007
  • Statement of problem: Titanium nitride(TiN) coatings are the most general and popular coating method and used to improve the properties of metallic surface for industrial purposes. When TiN coating applied to the abutment screw, frictional resistance would be reduced, as a results, the greater preload and prevention of the screw loosening could be expected. Purpose: The purpose of this study was to investigate mechanical properties of TiN coated film of various coating thickness on the titanium alloy surface and to evaluate proper coating thickness. Material and method: 95 Titanium alloy (Ti-6Al-4V) discs of 15 mm in diameter and 3 mm in thickness were prepared for TiN coating and divided into 7 groups in this study. Acceding to coating deposition time (CDT) with TiN by using Arc ion plating, were divided into 7 groups : Group A (CDT 30min), Group B (CDT 60min), Group C (CDT 90min), Group D (CDT 120min), Group E (CDT 150min), Group F(CDT 180min) and Group G (no CDT) as a control group. TiN coating surface was observed with Atomic Force Microscope(AFM), field emission scanning electron microscopy(FE-SEM) and examined with scratch tester, wear tester. Result: 1. Coating thickness fir each coated group was increased in proportion to coating deposition time. 2. Surface of all coated groups except Group A was homogeneous and smooth. However, surface of none coated Group G had scratch. 3. Adhesion strength for each coated group was increased in proportion to coating deposition time. 4. Wear resistance for each coated group was increased in proportion to coating deposition time. 5. Surface roughness in Group A, B, C was increased in proportion to coating deposition time. But, surface roughness in Group D, E, F was showed decreased tendency in proportion to coating deposition time. Conclusion: According to coating deposition time, mechanical properties of TiN coated film were changed. It was considered that 120 minutes coating deposition time ($1.32{\mu}m$ in coating thickness) is necessary.

Is Titanium Mesh Cage Safe in Surgical Management of Pyogenic Spondylitis?

  • Heo, Won;Kang, Dong-Ho;Park, Kyung-Bum;Hwang, Soo-Hyun;Park, In-Sung;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.357-362
    • /
    • 2011
  • Objective : To report our experience with pyogenic spondylitis treated with anterior radical debridement and insertion of a titanium mesh cage and to demonstrate the effectiveness and safety of the use of a titanium mesh cage in the surgical management of pyogenic spondylitis. Methods : We retrospectively analyzed the clinical characteristics of 19 patients who underwent surgical treatment in our department between January 2004 and December 2008. The average follow-up period was 11.16 months (range, 6-64 months). We evaluated risk factors, cultured organisms, lab data, clinical outcomes, and radiographic results. Surgical techniques for patients with pyogenic spondylitis were anterior radical debridement and reconstruction with titanium mesh cage insertion and screw fixation. All patients received intravenous antibiotics for at least 6 weeks postoperatively, and some patients received oral antibiotics. Results : The infections resolved in all of the patients as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. The mean pain score on a Visual Analog Scale was 7.8 (range, 4-10) before surgery and 2.4 (range, 1-5) after surgery. The Frankel grade was improved by one grade in seven patients. After surgery, the average difference of the angle was improved about $6.96^{\circ}$ in all patients. At the last follow-up, the mean loss of correction was $4.86^{\circ}$. Conclusion : Anterior radical debridement followed by the placement of instrumentation with a titanium mesh cage may be a safe and effective treatment for selected patients with pyogenic spondylitis. This surgical therapy does not lead to recurrent pyogenic spondylitis.