• 제목/요약/키워드: Titanium plate

검색결과 166건 처리시간 0.027초

하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES)

  • 구제훈;김일규;장재원;양정은;사시카라 바라라만;왕붕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.

The Economic Feasibility of Building-Integrated Photovoltaics System Installed on the Roof of Residential Building - Focused on Comparison with Construction Cost of BAPV System Depend on Roof Finishing Materials

  • Oh, Byung-Chil
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: This study was on the economic feasibility of BIPV system, focused on comparison with construction cost of BAPV system depend on roof finishing materials, and to suggest basic data on the construction cost. Method: Construction cost of BAPV system was calculated, by selecting asphalt single, flat type roof tile, color steel plate, titanium zinc plate as roof finishing material of residential building and by sum up each cost for roof finishing construction and cost for 3kWp-volumed PV module installation. Also, the economic feasibility was analysed quantitatively by comparing the cost for BIPV system construction, installing same volumed PV module instead of roof finishing materials. Result: 1. By installing BIPV system instead of the roof finishing material, the cost of construction falls ; about 19% in case of the titanium zinc plate, which is the most expensive, and about 11% in case of the color steel plate. 2. Reducing amount of the construction cost gets larger because of installing BIPV module instead of the roof finishing material, as the construction cost for roof finishing material gets higher ; therefore, it is more economical than BAPV system in terms of whole cost of construction.

EF-TEM 직접가열 실험을 통한 titanium의 고온 상전이 연구 (A Study of Titanium Phase Transition through In-situ EF-TEM Heating Experiments)

  • 김진규;이영부;김윤중
    • Applied Microscopy
    • /
    • 제33권1호
    • /
    • pp.49-58
    • /
    • 2003
  • EF-TEM 직접가열 실험을 통하여 titanium의 ${\alpha}-{\beta}$상전이를 연구하였다. 통계적 오차를 줄이기 위해 서로 다른 3군데의 titanium foil의 영역을 관찰하였고, 각각의 영역에 대해 단계별로($RT{\rightarrow}600{\rightarrow}900{\rightarrow}RT$) 회절패턴과 이미지를 기록하였다. 이 연구를 통해 얻은 결과는 다음과 같다. (1) Titanium은 $900^{\circ}C$에서 급격히 상전이가 진행된다. 이 온도에서는 ${\alpha}$${\beta}$-상이 같이 존재한다. (2) 상전이가 일어난 ${\beta}$-상의 영역은 쌍정구조를 가진 plate 형태로 나타나며, 그들은 서로 상호 회전 배열되어 있다. (3) 전자회절도형과 EDS 분석 결과, $600^{\circ}C$ 이상의 가열에서는 열적 산화에 의해 Ti의 산화물이 표면에서 생성되기 시작하며 이들은 냉각 시 Ti의 ${\beta}{\rightarrow}{\alpha}$ 가역 상전이를 저해한다.

LPG 재응축기용 순티타늄 박판의 Nd:YAG 레이저 용접성(I) - 순티타늄의 물성과 용접변수 - (Weldability of Pure Titanium Thin plate for LPG Re-Condenser by Nd:YAG Laser - Physical Constant and Welding Parameter -)

  • 김종도;곽명섭;이창제;김창수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.363-365
    • /
    • 2007
  • Titanium and its alloys have excellent corrosion resistance, high strength to weight ratios and high temperature creep properties, which make them using many various fields of application. Responding to these needs, welding processes for titanium are also being used including TIG, MIG, resistance welding, plasma arc welding, diffusion welding, electron beam welding and laser welding. In this study, It is possible to get sound beads without humping bead and spatter with the decrease of peak power according to increase of pulse width and change of welding speed for heat input control at pulsed Nd:YAG laser welding of titanium plates for Lap welding.

  • PDF

고도처리를 위한 금속티타늄 고정화광촉매기술평가 (Evaluation of Photocatalysis-Fixed Using Titanium for Advanced Wastewater Treatment)

  • 장준원;민지은;박재우
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.815-818
    • /
    • 2008
  • Titanium was oxidized with oxygen plasma and calcinated with rapid thermal annealing for degradation of humic acid dissolved in water. Titania photocatalytic plate was produced by titanium surface oxidized with oxygen plasma by Plasma Enhanced Chemical Vapor Deposition(PECVD). RF-power and deposition condition is controlled under 100 W, 150 W, 300 W and 500 W. Treatment time was controlled by 5 min and 10 min. The film properties were evaluated by the X-ray Photoelectron Spectroscopy (XPS) and X-Ray Diffraction (XRD). From the experimental results, we found the optimal condition of titania film which exhibited good performance. Moreover photocatalytic capacity was about twice better than thermal spray titania film, and also as good as titania powder.

  • PDF

Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support

  • Song, In-Seok;Ryu, Jae-Jun;Choi, Young-Jun;Lee, Ui-Lyong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.233-236
    • /
    • 2021
  • A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

하악골 골절 치료시 생체 흡수성 고정판 사용: 증례 보고 및 문헌고찰 (RESORBABLE PLATES FOR THE FIXATION OF MANDIBULAR FRACTURES: CASE REPORTS AND REVIEW OF THE LITERATURE)

  • 유지색;김수관;김학균;문성용
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권2호
    • /
    • pp.182-190
    • /
    • 2008
  • 본 증례에서는 자기강화 흡수성 고정판을 사용하여 하악골 골절을 정복하였다. 하악각 부위와 정중부, 부정중부, 하악지 부위의 골절이 발생하여 직경 2.0mm의 4-hole plate와 직경 2.4mm의 6-hole plate를 1개 혹은 2개를 사용하였다. 발생한 합병증에는 4명의 환자에 있어서 감각저하 이외에는 어떠한 합병증도 관찰되지 않았다. 본 연구의 추적 조사 기간이 너무 짧고 환자 수가 너무 적어 생체 흡수성 고정판을 사용한 골절 정복의 장기간의 효과를 결정할 수 없지만 하악골 골절의 초기 골 치유를 가능하게 하는 적절한 견고성과 안정성을 보여주었다.

Hydroxyapatite와 금(Au)이 혼합된 흡수성 고정판의 방사선비투과성; 예비 실험 (Radioopacity of Absorbable Plate containing Hydroxyapatite and Gold(Au); A Preliminary Report)

  • 김용하;남현재;이준호;김갑중;김연정;최식영
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.419-422
    • /
    • 2008
  • Purpose: Absorbable bone fixation materials for operation of facial bone fracture are composed of poly- lactic acid(PLA) & poly-glycolic acid(PGA). These materials are absorbed after facial bone healing period. Therefore, these materials are harmless in human body. But because of it's radioopacity, the number and the location of the materials are not checked in follow-up X-ray examination. We studied absorbable bone fixation materials checked radiological examination. So, we made the absorbable plate composed of PLA, Hydroxyapatite (HA) and Gold(Au). Methods: Plate 1 was consisted of pure PLA. Plate 2 was consisted of PLA(50%) and HA(50%). Plate 3 - 7 were consisted of PLA(50%), and variable composition of HA & Au. The ratio of Au was as following. From the plate 3 to plate 7, the Au ratio was 1%, 5%, 10%, 17%, and 25%, respectively. Total 3 examinations were used-naked eye examination, simple X-ray examination, and Haunsfield unit of plate in CT examination. Results: Naked eye examination found out that the color of plate 1 was most white. As the Au ratio increases, the color of plate was getting close to khaki color. the radioopacity of plate 2 was similar cortical bone of face in simple X-ray. The Haunsfield unit of cortical bone of face was 1000 HU. Haunsfield unit of titanium plate was 2900 HU. Haunsfield unit of plate 1 through plate 7 were -242, 1489, 1776, 3052, 3092, 3095, and 3095, respectively. Conclusion: Radioopacity of plate 2 was similar to cortical bone of face. In CT examination, Hanusfield unit of plate 2 was similar to Hanusfield unit of cortical bone of face. Hanusfield unit of plate 4 - 7 were similar to Hanusfield unit of titanium plate. So to trace bone fixation materials after facial bone surgery, the best ratio of Au is about 1 - 5%. If this study is applied to facial bone surgery, radiologic follow up would be easy after facial bone surgery.

타이타늄 소재 마찰교반용접 기술 동향 (Recent Trends of Friction Stir Welding of Titanium)

  • 천창근;김성욱;김흥주;장웅성;노중석
    • Journal of Welding and Joining
    • /
    • 제31권2호
    • /
    • pp.16-20
    • /
    • 2013
  • Titanium and its alloys have been widely using in the various field of industry application due to high corrosion resistant properties and mechanical properties. Titanium is highly reactive in the high temperature state and the formation of titanium oxide and porosities in the nuggets of fusion welding will results in the degradation of the mechanical properties. For this reason the studies of friction stir welding for titanium have been investigated recently. The FSW zones of titanium were classified by the weld nugget (WN), the linear transition boundary (TB) and the heat affected zone (HAZ). The WN along with titanium parent was characterized by the presence of twins and dislocations. The average grain size and hardness of WN has been changed according to heat input. The grain refinement resulted from the FSW increased the hardness in the stir zone. Sound dissimilar joints between SUS 304 and CP-Ti were achieved using an advancing speed of 50 mm/min and rotation speeds in the range of 700-1100 rpm. Aluminum 1060 and titanium alloy Ti-6Al-4V plates were lap joined by friction stir welding, hence the ultimate tensile shear strength of joint reached 100% of Al 1060. Mg alloy and Ti were successfully butt joined by inserting a probe into the Mg alloy plate with slightly offsetting. But Ti-Al intermetallic compound layers formed at the interface of these joints.

플라스틱 코팅 알루미늄 판형 열교환기의 성능에 관한 수치해석적 연구 (A Numerical Study on the Performance of Plastic Coated Aluminium Plate Heat Exchanger)

  • 최근호;김영일;김명수
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.22-29
    • /
    • 2018
  • The purpose of this study is to investigate the preliminary thermal performance of a plastic coated aluminum material(PCAM) plate heat exchanger. Plastic coating which has high corrosion resistivity and thermal conductivity can overcome corrosive weakness of aluminum material. The heat exchangers are modeled for STS316, Titanium and PCAM materials, and analyzed numerically using HTRI and ANSYS Fluent CFD softwares. The results show that PCAM heat exchanger is superior in heat transfer performance compared to existing materials. For chevron angle of $60^{\circ}$, thermal performances of Titanium and PCAM are higher by 12.2% and 48.9% when compared to STS316, respectively.