• 제목/요약/키워드: Titanium grade

검색결과 79건 처리시간 0.022초

Is Titanium Mesh Cage Safe in Surgical Management of Pyogenic Spondylitis?

  • Heo, Won;Kang, Dong-Ho;Park, Kyung-Bum;Hwang, Soo-Hyun;Park, In-Sung;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권4호
    • /
    • pp.357-362
    • /
    • 2011
  • Objective : To report our experience with pyogenic spondylitis treated with anterior radical debridement and insertion of a titanium mesh cage and to demonstrate the effectiveness and safety of the use of a titanium mesh cage in the surgical management of pyogenic spondylitis. Methods : We retrospectively analyzed the clinical characteristics of 19 patients who underwent surgical treatment in our department between January 2004 and December 2008. The average follow-up period was 11.16 months (range, 6-64 months). We evaluated risk factors, cultured organisms, lab data, clinical outcomes, and radiographic results. Surgical techniques for patients with pyogenic spondylitis were anterior radical debridement and reconstruction with titanium mesh cage insertion and screw fixation. All patients received intravenous antibiotics for at least 6 weeks postoperatively, and some patients received oral antibiotics. Results : The infections resolved in all of the patients as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. The mean pain score on a Visual Analog Scale was 7.8 (range, 4-10) before surgery and 2.4 (range, 1-5) after surgery. The Frankel grade was improved by one grade in seven patients. After surgery, the average difference of the angle was improved about $6.96^{\circ}$ in all patients. At the last follow-up, the mean loss of correction was $4.86^{\circ}$. Conclusion : Anterior radical debridement followed by the placement of instrumentation with a titanium mesh cage may be a safe and effective treatment for selected patients with pyogenic spondylitis. This surgical therapy does not lead to recurrent pyogenic spondylitis.

Grade II 순수 타이타늄의 단시간 양극산화에 의한 TiO2 나노튜브 형성 (TiO2 Nanotubular Formation on Grade II Pure Titanium by Short Anodization Processing)

  • 이광민;김용재;강경호;윤두현;노상현;강석일;유대흥;임현필;윤귀덕;박상원;김현승
    • 한국재료학회지
    • /
    • 제23권4호
    • /
    • pp.240-245
    • /
    • 2013
  • Electrochemical surface treatment is commonly used to form a thin, rough, and porous oxidation layer on the surface of titanium. The purpose of this study was to investigate the formation of nanotubular titanium oxide arrays during short anodization processing. The specimen used in this study was 99.9% pure cp-Ti (ASTM Grade II) in the form of a disc with diameter of 15 mm and a thickness of 1 mm. A DC power supplier was used with the anodizing apparatus, and the titanium specimen and the platinum plate ($3mm{\times}4mm{\times}0.1mm$) were connected to an anode and cathode, respectively. The progressive formation of $TiO_2$ nanotubes was observed with FE-SEM (Field Emission Scanning Electron Microscopy). Highly ordered $TiO_2$ nanotubes were formed at a potential of 20 V in a solution of 1M $H_3PO_4$ + 1.5 wt.% HF for 10 minutes, corresponding with steady state processing. The diameters and the closed ends of $TiO_2$ nanotubes measured at a value of 50 cumulative percent were 100 nm and 120 nm, respectively. The $TiO_2$ nanotubes had lengths of 500 nm. As the anodization processing reached 10 minutes, the frequency distribution for the diameters and the closed ends of the $TiO_2$ nanotubes was gradually reduced. Short anodization processing for $TiO_2$ nanotubes of within 10 minutes was established.

주입선 형태가 타이타늄 합금의 주조성에 미치는 영향 (THE EFFECT OF CASTING MACHINE AND INVESTMENT ON THE CASTABILITY OF TITANIUM)

  • 김상태;방몽숙;양홍서;박상원;박하옥;임현필
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.522-533
    • /
    • 2007
  • Statement of problem: Despite of the recent development of the titanium casting system methods, the casting defects such as imperfect casting and internal porosity were frequently observed. Purpose: The purposes of this study were to compare and measure the castability, microhardness, and surface reaction between Grade 2 pure titanium and Ti-6Al-4V by casting these alloys from the different sprue design conditions. Material and methods: Depending on the sprue designs and titanium alloys, 42 ready-made wax patterns were used. By analyzing the remodeling of the cast, internal porosity, microhardness, and titanium surface layer of SEM, there were several results we observed. Results: 1. The measured castability of titanium were categorized in the ascending order: individual sprue group, runner bar group, and single group. This data are based on the statistically signigicant differences. 2. The castability of titanium has not showed the statistically significant differences among the alloys. However, CP-Ti groups were superior to Ti-6Al-4V groups by showing the noticeable castability. 3. The surface layers of the castings of all groups have showed $5{\mu}m$ titanium oxide layers irrespective of sprue designs and titanium alloys. Conclusion: From the above study results, by fabricating the restorations from the centrifugal casting machine direct sprue designs revealed better castability. As we increased the number of sprues in the wax pattern, it revealed better castability. The castability of pure titanium rather than that of Ti-6Al-4V was remarkable. To fabricate the complex forms of the restorations, further researches on the efficient sprue designs and titanium alloys must be made.

티타늄 산화물강 열영향부 조직변태에 미치는 망간 및 탄소의 영향 (Effects of Manganese and Carbon on the HAZ Microstructural Evolution in Titanium Oxide Steel)

  • 방국수
    • Journal of Welding and Joining
    • /
    • 제22권2호
    • /
    • pp.78-84
    • /
    • 2004
  • Effects of manganese and carbon on the HAZ microstructural evolution in 500㎫ grade titanium oxide steels were investigated. Microstructural evolution primarily depends on supercooling. When cooled at 3$^{\circ}C$/s in 0.15%C-1.5%Mn steel, grain boundary and Widmanst tten ferrite formed at 640 and 62$0^{\circ}C$, respectively, followed by competitive formation of acicular ferrite and upper bainite inside of grain at 58$0^{\circ}C$. With an increase of manganese, degree of supercooling increased while critical cooling rate for the formation of gain boundary ferrite decreased. Consequently, the amount of acicular ferrite in HAZ was decreased in 2.0%Mn after initial increase in 1.0 and 1.5%Mn. Therefore, optimum supercooling should be maintained to accelerate acicular ferrite formation in titanium oxide steels. Low carbon steel, 0.11%C-1.5%Mn, showed larger amount of acicular ferrite than higher carbon steel because of effectiveness of diffusionless transformation in low carbon steel.

9mm 합금타이타늄 중간 선재 연구 (A Study on The Φ 9mm Titanium Alloy Wire)

  • 김상연
    • 한국산학기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.8-13
    • /
    • 2012
  • Ti-3Al-2.5V 잉고트를 제작하고 직경 9mm 합금타이타늄 wire로 가공하여 수입소재와 비교하여 그 특성을 조사하였다. 잉고트는 산소함량이 0.11wt%이고 철 함량이 0.085wt%로서 ASTM Gr.9 규격을 만족하였다. 9mm 합금 타이타늄 wire 경도는 225-250Hv로 비슷한 결과를 얻었고, 인장강도는 수입소재가 804MPa이고, 국내 개발품은 734MPa이었다. 연신율은 수입소재가 12%이고 국내 개발품은 22%였다. 직경 400mm 잉고트에서 단조 및 다단 열간 압연공정을 통해 직경 9.0mm 타이타늄합금선재를 제작하는 새로운 제작공정을 개발하였다.

MMO(Ti/Ru) 코팅된 타이타늄의 고분자 전해질 연료전지 양극환경에서의 전기화학적 거동 (Electrochemical Characteristics of MMO(Ti/Ru)-Coated Titanium in a Cathode Environment of Polymer Electrolyte Membrane Fuel Cell)

  • 허호성;김성종
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.340-347
    • /
    • 2022
  • In this research, mixed metal oxide (TiO2, RuO2) coating was applied to grade 1 titanium as a bipolar plate for polymer electrolyte membrane fuel cell (PEMFC). Electrochemical experiments were carried out in an aqueous solution of pH 3 (H2SO4 + 0.1 ppm HF, 80 ℃) determined by DoE. The air was bubbled to simulate a cathode environment. Potentiodynamic polarization test revealed that corrosion current densities of the titanium substrate and MMO-coated specimen were 0.180 µA/cm2 and 4.381 µA/cm2, respectively. There was no active peak. After potentiostatic experiment, current densities of the titanium substrate and the MMO-coated specimen were 0.19 µA/cm2 and 1.05 µA/cm2, respectively. As a result of observing the surface before and after the potentiostatic experiment, cracked dried clay structures were observed without corrosion damage. Both the titanium substrate and the MMO-coated specimen could not satisfy the interfacial contact resistance suggested by the DoE. Thus, further research is needed before they could be applied as bipolar plates.

음향 이방성을 고려한 티타늄 용접부의 결함길이 측정에 관한 연구 (A Study on the Defect length Measurement of Titanium Weld Zone Considering Acoustical Anisotropy)

  • 박희동;윤인식;이원
    • 한국정밀공학회지
    • /
    • 제28권9호
    • /
    • pp.1070-1077
    • /
    • 2011
  • This study intends to assess the defect in the weld zone of titanium grade 2 plate in terms of acoustical anisotropy based on the angle beam method. Depending on the rolling direction, the ratio of wave velocity was found to be 1.08 and the difference in the angle of refraction was more than seven degrees, confirming the presence of acoustical anisotropy. Thus for measuring the length of defect in the weld zone of the titanium plate (thickness of 10mm), the distance amplitude characteristics curves of titanium, TDACC-R and TDACC-T were constructed for the measurements in consideration of the acoustical anisotropy on CRT of the ultrasonic testing equipment. As a result, when the distance amplitude characteristics curve corresponds to the rolling direction, the length of defect was close to the actual measurement within 1mm and when different, the difference was found to be over 4mm. It was affirmed that the acoustical anisotropy should be taken into consideration when measuring the length of defects in the weld zone of the titanium plate with the presence of acoustical anisotropy.

타이타늄 표면 코팅이 도재 결합에 미치는 영향 (EFFECTS OF TITANIUM SURFACE COATING ON CERAMIC ADHESION)

  • 김연미;김현승;이광민;이도재;오계정;임현필;서윤정;박상원
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.601-610
    • /
    • 2007
  • Statement of problem: The adhesion between titanium and ceramic is less optimal than conventional metal-ceramic bonding, due to reaction layer form on cast titanium surface during porcelain firing. Purpose: This study characterized the effect of titanium-ceramic adhesion after gold and TiN coating on cast and wrought titanium substrates. Material and method: Six groups of ASTM grade II commercially pure titanium and cast titanium specimens$(13mm{\times}13mm{\times}1mm)$ were prepared(n=8). The conventional Au-Pd-In alloy served as the control. All specimens were sandblasted with $110{\mu}m\;Al_2O_3$ particles and ultrasonically cleaned for 5min in deionized water and dried in air before porcelain firing. An ultra-low-fusing dental porcelain (Vita Titankeramik) was fused on titanium surfaces. Porcelain was debonded by a biaxial flexure test at a cross head speed of 0.25mm/min. The excellent titanium-ceramic adherence was exhibited by the presence of a dentin porcelain layer on the specimen surface after the biaxial flexure test. Area fraction of adherent porcelain (AFAP) was determined by SEM/EDS. Numerical results were statistically analyzed by one-way ANOVA and Student-Newman-Keuls test at ${\alpha}=0.05$. Results: The AFAP value of cast titanium was greatest in the group 2 with TiN coating, followed by group 1 with Au coating and the group 3 with $Al_2O_3$ sandblasting. Significant statistical difference was found between the group 1, 2 and the group 3 (p<.05). The AFAP value of wrought titanium was greatest in the group 5 with TiN coating, followed by the group 4 with Au coating and the group 6 with $Al_2O_3$ sandblasting. Conclusion: No significant difference was observed among the three groups (p>.05). The AFAP values of the cast titanium and the wrought titanium were similar. However the group treated with $Al_2O_3$ sandblasting showed significantly lower value (p<.05).

Electrochemical Study of Three Stainless Steel Alloys and Titanium Metal in Cola Soft Drinks

  • Peralta-Lopez, D.;Sotelo-Mazon, O.;Henao, J.;Porcayo-Calderon, J.;Valdez, S.;Salinas-Solano, G.;Martinez-Gomez, L.
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.294-306
    • /
    • 2017
  • Stainless steels and titanium alloys are widely used in the medical industry as replacement materials. These materials may be affected by the conditions and type of environment. In the same manner, soft drinks are widely consumed products. It is of interest for dental industry to know the behavior of medical-grade alloys when these are in contact with soft drinks, since any excessive ion release can suppose a risk for human health. In the present study, the electrochemical behavior of three stainless steel alloys and pure titanium was analyzed using three types of cola soft drinks as electrolyte. The objective of this study was to evaluate the response of these metallic materials in each type of solution (cola standard, light and zero). Different electrochemical techniques were used for the evaluation of the alloys, namely potentiodynamic polarization, linear polarization, and open-circuit potential measurements. The corrosion resistance of the stainless-steel alloys and titanium in the cola soft drinks was provided by the formation of a stable passive film formed by metal oxides. Scanning electron microscopy was used as a complementary technique to reveal corrosion phenomena at the surface of the materials evaluated.

Aspects of Nanotechnology In Inorganic Sunscreen Dispersions: Efficacy and Aesthetics

  • Arthur Georgalas
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book I
    • /
    • pp.97-97
    • /
    • 2003
  • Chemists must take into consideration more factors to formulate with inorganic sunscreens than many other active ingredients including organic sunscreens. Because the UV radiation attenuation grade particles of Titanium Dioxide and Zinc Oxide are in the nanometer range, the state of their dispersion in the product film on the skin governs their efficacy and aesthetics.(omitted)

  • PDF