• 제목/요약/키워드: Titanium alloys

검색결과 288건 처리시간 0.022초

고온 변형 곡선을 이용한 동적 재결정 해석과 동적 상변태의 조기 예측 (Precise Flow Stress Analysis for the Occurrence of Dynamic Ferritic Transformation and Dynamic Recrystallization of Austenite in Low Carbon Steel)

  • 박노근
    • 대한금속재료학회지
    • /
    • 제56권11호
    • /
    • pp.779-786
    • /
    • 2018
  • There have been previous attempts to observe the occurrence of dynamic ferritic transformation at temperatures even above $Ae_3$ in a low-carbon steel, and not only in steels, but recently also in titanium alloys. In this study, a new approach is proposed that involves treating true stress-true strain curves in uniaxial compression tests at various temperatures, and different strain rates in 0.1C-6Ni steel, which is a model alloy used to decelerate the kinetics of ferrite transformation from austenite. The initial flow stress up to peak stress was used to analyze the change in dynamic softening phenomena, such as dynamic recovery, dynamic recrystallization, and dynamic transformation. It is worth mentioning that for predicting the occurrence of dynamic transformation, flow stress before reaching peak stress is much more sensitive to the change in the dynamic softening rate due to dynamic transformation, compared to peak stress. It was found that the occurrence of dynamic ferritic transformation could be successfully obtained even at temperatures above $Ae_3$ once the deformation condition was satisfied. This deformation condition is a function of both the strain rate and the deformation temperature, which can be described as the Zener - Hollomon parameter. In addition, the driving force of dynamic ferritic transformation might be much less than that of the dynamic recrystallization of austenite at a given deformation condition. By applying this technique, it is possible to predict the occurrence of dynamic transformation more sensitively compared with the previous analysis method using peak stress during deformation.

냉간단조 금형 WC-Co합금의 인장시험방법 개발 및 물성평가 (Development of Uniaxial Tensile Test Method to Evaluate Material Property of Tungsten Carbide-Cobalt Alloys for Cold Forging Dies)

  • 권인우;서영호;정기호
    • 소성∙가공
    • /
    • 제27권6호
    • /
    • pp.370-378
    • /
    • 2018
  • Cold forging, carried out at room temperature, leads to high dimensional accuracy and excellent surface integrity as compared to other forging methods such as warm and hot forgings. In the cold forging process, WC-Co (Tungsten Carbide-Cobalt) alloy is the mainly used material as a core dies because of its superior hardness and strength as compared to other structural materials. For cold forging, die life is the most significant factor because it is directly related to the manufacturing cost due to periodic die replacement in mass production. To investigate die life of WC-Co alloy for cold forging, mechanical properties such as strength and fatigue are essentially necessary. Generally, uniaxial tensile test and fatigue test are the most efficient and simplest testing method. However, uniaxial tension is not efficiently application to WC-Co alloy because of its sensitivity to alignment of the specimen due to its brittleness and difficulty in thread machining. In this study, shape of specimen, tools, and testing methods, which are appropriate for uniaxial tensile test for WC-Co alloy, are proposed. The test results such as Young's modulus, tensile strength and stress-strain curves are compared to those in previous literature to validate the proposed testing methods. Based on the validation of test results it was concluded that the newly developed testing method is applicable to other cemented carbides like Titanium carbides with high strength and brittleness, and also can be utilized to carry out fatigue tests for further investigation on die life of cold forging.

구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향 (The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials)

  • 이아름;정정훈;정겨운;방은경
    • 대한치과보철학회지
    • /
    • 제52권3호
    • /
    • pp.177-185
    • /
    • 2014
  • 목적: 본 연구는 구리 합금 스케일러 팁을 비롯한 수종의 스케일러 팁이 임플란트와 수복물 재료 표면에 실제 치석제거 시와 같이 적용하였을 때 표면 거칠기에 미치는 영향을 알아보고자 하였다. 재료 및 방법: 도재, 티타늄, 지르코니아, 제3형 금합금의 지름 15 mm, 높이 1.5 mm의 원반형 시편을 준비하였고, 거칠기 형성기구로 스테인리스 스틸팁(SS), 플라스틱 수동 큐렛(PS), 구리 합금 팁(IS)을 이용하였으며, 시편의 개수는 각 재료 당 기구 별로 4개씩 총 64개를 사용하였다. 표면 거칠기는 40 g의 힘으로 초음파 스케일러는 시편의 표면과 팁이 15도, 핸드 큐렛은 시편의 표면과 큐렛의 날이 45도가 되도록 하여 1초에 1회 5 mm 수평 왕복운동을 30초 동안 시행하여 형성하였다. 각 시편을 주사전자 현미경을 이용하여 관찰하였고, 원자현미경과 표면조도 거칠기 단 차 측정기를 이용하여 표면 거칠기(Ra, ${\mu}m$)를 측정하고 분석하였다. 결과: 주사전자 현미경으로 관찰 결과 표면 거칠기의 증가는 스테인리스 스틸 팁(Group SS)에서 가장 컸으며 구리 합금 팁(Group IS)에서 가장 적게 나타났다. 원자현미경으로 표면 거칠기를 측정한 결과, 스테인리스 스틸 팁(Group SS)은 도재 군과 제3형 금합금 군에서 대조군과 플라스틱 수동 큐렛(Group PS), 구리 합금 팁(Group IS)보다 표면 거칠기가 유의성 있게 크게 나타났고, 구리 합금 팁(Group IS)은 금합금 군에서는 스테인리스 스틸 팁(Group SS)과 플라스틱 수동 큐렛(Group PS)에 비해 표면 거칠기가 유의성 있게 적게 나타났다. 표면조도 거칠기 단 차 측정기로 측정 결과, 스테인리스 스틸 팁(Group SS)은 모든 군에서 대조군 및 플라스틱 수동 큐렛(Group PS)과 구리 합금 팁(Group IS)보다 표면 거칠기가 유의성 있게 크게 나타났으며, 구리 합금 팁(Group IS)은 모든 군에서 스테인리스 스틸 팁(Group SS)에 비해 표면 거칠기가 유의성 있게 적게 나타났다. 제3형 금합금은 도재, 티타늄, 지르코니아 군에 비해 치석제거 기구에 의한 표면 거칠기의 증가가 크게 나타났다(P<.05). 결론: 이상의 연구결과 새로이 개발된 구리 합금 팁(IS)을 적용하였을 때 티타늄 및 치과 수복 재료의 표면 거칠기에 영향을 주지 않음으로써, 임플란트 및 수복치료 된 치아의 치석제거 시 전통적인 스테인리스 스틸 팁(SS)의 대용품으로 유용하게 사용될 수 있을 것으로 사료된다.

생체 유리와 소다 유리침투에 따른 알루미나 세라믹의 굴곡 강도 및 PBS에서의 표면 생성물 연구 (Bending strength of alumina coated with bioglass and soda lime glass and the precipitation on the surface of coated alumina in PBS)

  • 유재양
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.39-45
    • /
    • 2008
  • Titanium and its alloys are widely used as dental implants materials because of their excellent mechanical properties. However, the alumina and zirconia ceramics are preferred to use as the substitute of Ti implants because there is a problems in esthetics and biocompatibility in Ti implant. The the glass infiltrated alumina ceramics are studied to increase the toughness and biocompatibility. The 45S5 and soda-lime glass powder was mixed with ethanol at ratio of 1:1 and brushed on the surface of alumina. Then it was heat treated in the electric furnace at $1400^{\circ}C$ from 30 min. to 5 hours. The glass powder was controlled from 200 to $350{\mu}m$ using ball milling. After heat treatment, the glass infiltrated specimen was tested in universal testing machine to measure the bending strength. The surface microstructure of each specimen was observed with SEM. The biocompatibility of 45S5 and soda-lime glass coated alumina was investigated using PBS at $36.5^{\circ}C$ incubator. The specimen was immersed in PBS for 3, 5, 7, 10 days. After that, the surface morphology was investigated with SEM. As the results of experiment, the 45S5 bioglass infiltrated alumina show the increase of bending strength according to the increasing of heat treatment time from 30 min. to 5 hours at $1400^{\circ}C$ Finally the 1370N bending strength of alumina increased to 1958N at 5 hours heat treatment, which shows 1.4 times higher. In contrast to this, the soda lime glass infiltrated alumina ceramics shows the convex curve according to heat treatment time. Thus it shows maximum bending strength of 1820N at 1 hour heat treatment of $1400^{\circ}C$ It gives 1.3 times higher. However, the bending strength of soda lime glass infiltrated alumina is decreasing with increasing heat treatment time after 1 hour. The precipitation on the surface of 45S5 glass infiltrated alumina was revealed as a sodium phosphate ($Na_{6}P_{6}O_{24}6H_{2}O$) and the amount of precipitation is increasing with increasing of immersion time in PBS. In contrast to this, there is no precipitation are observed on the surface of soda lime glass infiltrated alumina. This implies that 45S5 glass infiltrated alumina brings more biocompatible when it is implanted in human body.

  • PDF

Ti-6Al-4V 합금의 알칼리 및 열처리가 인산칼슘 침착에 미치는 영향 (Effect of Alkali and Heat Treatments of Ti-6Al-4V Alloy on the Precipitation of Calcium Phosphate)

  • 박재한;임기정;김상목;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제30권1호
    • /
    • pp.187-203
    • /
    • 2000
  • The precipitation of calcium phosphate on implant surface has been known to accelerate osseointegration and to enhance osseous adaptation. The present study was performed to examine whether the precipitation of calcium phosphate on Ti-6Al-4V alloy could be affected by the immersion in NaOH solution and heat treatment. Ti-6Al-4V alloy plates of $15{\times}3.5{\times}1mm$ in dimension were polished sequentially from #240 to #2,000 emery paper and one surface of each specimen was additionally polished with $0.1{\mu}m$ alumina paste. Polished specimens were soaked in various concentrations of NaOH solution(0.1, 1.0, 3.0, 5.0, 7.0, 10.0 M) at $60^{\circ}C$ for 24 hours for alkali treatment, and 5.0 M NaOH treated specimens were heated for 1 hour at each temperature of 400, 500, 600, 700, $800^{\circ}C$. After the alkali and heat treatments, specimens were soaked in the Hank's solution with pH 7.4 at $36.5^{\circ}C$ for 30days.The surface ingredient change of Ti-6Al-4V alloy was evaluated by thin-film X-ray diffractometer(TF-XRD) and the surface microstructure was observed by scanning electron microscope(SEM), and the elements of surface were analyzed by X-ray photoelectron spectroscopy(XPS). The results were obtained as follows ; 1. The precipitation of calcium phosphate on Ti-6Al-4V alloy was accelerated by the immersion in NaOH solution and heat treatment. 2. In Alkali treatment for the precipitation of calcium phosphate on Ti-6Al-4V alloy, the optimal concentration of NaOH solution was 5.0 M. 3. In heat treatment after alkali treatment in 5.0 M NaOH solution, the crystal formation on alloy surface was enhanced by increasing temperature. In heat treated alloys at $600^{\circ}C$, latticed structure and prominences of calcium phosphate layer were most dense. On heat treated alloy surface at the higher temperature(${\geq}700^{\circ}C$), main crystal form was titanium oxide rather than apatite. The above results suggested that the precipitation of calcium phosphate on the surface of Ti-6Al-4V alloy could be induced by alkali treatment in 5.0 M-NaOH solution and by heat treatment at $600^{\circ}C$.

고상반응법에 의한 아커마나이트 분말의 합성 및 생체활성도 평가 (Synthesis of akermanite bioceramics by solid-state reaction and evaluation of its bioactivity)

  • 고재은;이종국
    • 한국결정성장학회지
    • /
    • 제32권5호
    • /
    • pp.191-198
    • /
    • 2022
  • 치과용 임플란트 재료로 주로 사용되는 지르코니아 및 티타늄 합금은 생체불활성 특징으로 인하여 골유착 및 골형성 능력이 떨어진다. 이러한 문제를 쉽고 간단하게 해결하기 위한 방법으로는 생체활성 물질을 표면에 코팅하여 생체 활성을 높이는 방법이 있다. 본 연구에서는 우수한 골결합 능력을 가진 실리케이트계 세라믹인 아커마나이트(Ca2MgSi2O7)를 고상반응법으로 합성하고, SBF 용액 내 침적실험을 통하여 합성 아커마나이트 분말의 생체활성을 분석하였다. 고상반응 출발원료로는 탄산칼슘(CaCO3), 탄산마그네슘(MgCO3), 이산화규소(SiO2) 분말을 사용하였다. 분말을 혼합 및 건조한 후, 가압 성형하여 디스크 형태로 만든 후, 고상반응 온도를 변화시키며 아커마나이트 상의 합성을 유도하였다. 합성된 아커마나이트 펠릿의 용해 및 생체활성 분석을 위하여 SBF 용액 내 침적 시키고, 침적시간에 따라 아커마나이트의 표면 용해 및 하이드록시아파타이트 석출을 분석하였다. 합성반응 온도가 높아질수록 아커마나이트 상이 뚜렷하게 나타난 반면에, SBF 용액 내 용해는 천천히 진행되었다. 합성된 아커마나이트 분말의 생체활성도는 대체적으로 우수하였으나, 그 중에서도 1100℃에서 고상반응 하여 합성한 분말에서 적절한 용해 및 하이드록시아파타이트 입자의 석출이 잘 일어나는 것으로 분석되었다.

브라켓 각도 변화에 따른 세라믹 브라켓의 마찰력 측정 (Evaluation of friction of ceramic brackets in various bracket-wire combinations)

  • 차정열;김경석;김동춘;황충주
    • 대한치과교정학회지
    • /
    • 제36권2호
    • /
    • pp.125-135
    • /
    • 2006
  • 최근 사용되고 있는 세라믹 브라켓의 마찰력을 측정하고 비교하고자 실험군으로 3종의 세라믹 브라켓(Crystaline $V^{(R)}$, Tomy, Tokyo, Japan; $Clarity^{(R)}$, 3M Unitek, CA; $Inspire^{(R)}$, Ormco, CA)을 사용하였으며 대조군으로 컴퍼짓 레진브라켓($Spirit^{(R)}$, Ormco, CA)과 메탈브라켓($Kosaka^{(R)}$, Tomy, Tokyo, Japan)을 사용하였다. 활주 시 마찰력은 4개의 브라켓-교정선 경사$(0^{\circ},\;5^{\circ},\;10^{\circ},\;15^{\circ})$에서 각각 측정되었으며 두 종의 교정선 [1. 스테인레스 스틸(Stainless Steel, SDS Ormco, Glendora, CA), 2. 베타-타이타늄(TMA, SDS Ormco, Glendora, CA)]이 사용되었다. 22 mil 브라켓을 만능시험기기에 부착한 후 $.021{\times}.025$ 크기의 교정선에 고무결찰한 후 $34^{\circ}C$의 건조상태에서 5 mm/min 속도로 교정 선을 활주시켰다. TMA 교정선은 스테인레스 스틸 교정선보다 높은 마찰력을 발생시켰으며 모든 브라켓 호선과의 조합에서 브라켓-교정선의 각도가 증가함에 따라 정적, 동적 마찰력이 증가하였다. $0^{\circ}{\sim}5^{\circ}$ 구간에서 마찰력의 크기는 스테인레스 스틸 교정선과 레진 브라켓 조합이 가장 낮게 측정되었으며 다음으로 Crystaline V, 금속 브라켓, Clarity, Inspire의 순으로 나타났다. TMA 교정선에서는 Crystaline V와의 조합이 가장 낮은 마찰력을, 다음으로 컴퍼짓 브라켓, Clarity, 금속 브라켓, Inspire 순으로 나타났다. $5^{\circ}$ 이상에서 마찰력이 급격하게 증가하였으며 스테인레스 스틸 교정선에서 레진 브라켓, Clarity, Crystaline V, 금속 브라켓, Inspire순으로 나타났다. TMA 교정선에서는 레진 브라켓, Crystaline V, Clarity, Inspire, 금속 브라켓 순으로 나타났다. 이때 호선 브라켓 조합에 대한 마찰력은 일반적으로 증가하였으나 마찰력 증가율의 차이로 인해 그룹간 마찰력의 순위가 서로 뒤바뀌는 경우가 관찰되었다. 실리카-삽입 세라믹 브라켓은 기존의 세라믹 브라켓보다 낮은 마찰력을 보여줄 뿐 아니라 브라켓-교정선의 경사도의 증가에서도 비교적 낮은 마찰력 증가율을 나타내어 세라믹 브라켓의 높은 마찰력을 감소시키는데 큰 역할을 할 수 있다고 생각된다.

크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구 (Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP)

  • 오계정;서윤정;윤귀덕;임현필;박상원;이경구;임태관;이도재
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.120-127
    • /
    • 2011
  • 연구 목적: 본 연구의 목적은 색소체인 크롬염화물을 지르코니아에 첨가함으로써 지르코니아의 색상 및 물리적 성질, 그리고 미세구조가 어떻게 변화하는지 알아보고자 한다. 연구 재료 및 방법: 크롬염화물의 함량이 지르코니아 분말에 각각 0.06, 0.12, 0.25 wt%가 되도록 측량하고 알코올에 녹여 액상상태의 크롬염화물을 준비하였다. 지르코니아 분말과 각각의 액상상태의 크롬염화물을 혼합하고 혼합된 분말을 이용하여 디스크형태의 지르코니아 시편을 제작하였다. 제작된 시편은 $1450^{\circ}C$에서 완전소결 후 색상 및 물리적 성질, 그리고 미세구조를 관찰하였다. 색상은 분광측색장치를 이용하여 국제조명위원회 (CIE) ISO 기준인 D65 광원, SCE 방식으로 측정하여 $L^*$, $C^*$, $a^*$, $b^*$ 값으로 분석하였다. 밀도는 아르키메데스 법으로 측정하였고, 주사전자현미경과 X선 회절 분석기를 이용하여 시편의 미세구조 및 결정상을 관찰하였다. 파괴인성은 압흔 형성법(Vickers indentation법)을 이용하여 시편에 압흔 형성 후, 광학현미경으로 압흔의 크기를 측정하고 이를 이용하여 파괴인성을 구하였다. 결과는 일원배치분산분석 (one-way ANOVA)으로 통계처리 하였고, Tukey test로 사후 검정하였다. 결과: 1. 크롬염화물을 첨가하여 지르코니아의 색상을 조절할 수 있음을 확인하였으며, 크롬염화물 첨가 함량이 증가함에 따라 지르코니아 색상은 백색계통의 갈색에서 짙은 색의 갈색으로 변하였다. 2. 크롬염화물의 첨가는 시편의 밀도를 점점 감소시켰으며, 크롬염화물이 첨가되지 않은 시편과 비교 시, 크롬염화물의 첨가량이 증가할수록 통계학적으로 유의한 차이를 보였다 (P<.05). 3. 크롬염화물이 첨가된 시편은 첨가되지 않는 시편에 비해 결정립 크기가 증가하였다. 4. X-선 회절 분석결과, 크롬염화물의 첨가 여부와 첨가 함량에 상관없이 지르코니아 결정상의 차이점은 관찰되지 않았다. 5. 지르코니아에 크롬염화물을 첨가 시 크롬염화물의 첨가 함량에 따라 파괴인성값은 감소하였고, 특히 0.25 wt%의 크롬염화물을 첨가 시 가장 낮은 파괴인성 값을 보였다 (P<.05). 결론: 이상의 결과로 크롬염화물을 액체상태로 첨가하여 지르코니아의 색상을 조절할 수 있음을 확인하였으며, 제작한 유색 지르코니아의 색상은 자연치아 색상과 다소 차이가 있지만, 본 소재는 임상에서 사용되는 완전도재관 코어 (Core) 재료로써 사용할 수 있을 것으로 생각한다.