• Title/Summary/Keyword: Tissue therapy

Search Result 1,637, Processing Time 0.035 seconds

The Effect of Rubus coreanum Miquel Against Lipopolysaccharide-induced Oxidative Stress and Lipid Metabolism (복분자 추출물이 LPS로 유도된 산화적 스트레스와 지질대사에 미치는 영향)

  • Kim, In-Deok;Kang, Kum-Suk;Kwon, Ryun-Hee;Yang, Jeong-Ok;Lee, Joong-Sook;Ha, Bae-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.213-217
    • /
    • 2007
  • LPS induces the synthesis of several inflammatory cytokine, chemokine, NO and inflammation in the liver of rats. The purpose of this study was to investigate the preventive effects of Rubus coreanum Miquel (RCM) In lipid metabolism. RCM of 100 mg/kg concentration was intraperitoneally administered into rats at dose of 1.5ml/kg for 20 days. On the day 21, 1.5ml/kg of LPS was injected 4 hours before anesthetization. We examined the lipid-related functions by measuring the levels of triglyceride (TG), total cholesterol (TC), total lipid (TL), high-density lipoprotein cholesterol (HDL-C) in serum and malondialdehyde(MDA) in liver tissue. The results showed that LPS treatment increased the values of TG, TC, TL and MDA, decreasing that of HDL-C. But RCM pretreatment decreased the high values of TG, TC, TL and MDA to the low values and increased the low value of HDL-C to the high value. These results suggested that RCM could be used as the potential candidate for the lipid metabolism natural supplement.

Clinical Study of the Patients, in Whom Pulmonary Embolism was Suspected by Lung Perfusion Scan (폐 관류주사검사상 폐동맥 색전증 소견을 보인 환자의 임상적 고찰)

  • Lee, Gwi-Lae;Kim, Jae-Yeol;Park, Jae-Suk;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.889-898
    • /
    • 1997
  • Pulmonary Embolism can develop in variable conditions, and presents with nonspecific symptoms and signs. If diagnosis is delayed, it can be resulted in catastrophic results. Therefore, early diagnosis and adequate treatment is crucial in Pulmonary Embolism. Lung Perfusion Scan is useful screening test. Negative result can exclude pulmonary embolism. But, perfusion defects don't always mean pulmonary embolism. To find the better methods of interpretation of lung perfusion scan and To evaluate the clinical course and outcomes of the patients, in whom pulmonary embolism was suspected by lung perfusion scan, we reviewed the clinical records of 49 cases suspected by lung perfusion scan at Seoul National University Hospital during the period of January, 1995 to July, 1996. The results are as follows. First impression of cases in which PE was present at time of admission were pulmonary embolism (63%), heart diseases (26%), and pneumonia (11%) in orders. Underlying diseases of cases in which PE developed during admission were malignancy (36.5%), ICH (22.7%), sepsis (13.7%), and SLE (9.1%) in orders. The predisposing factors were operation (20%), cancer (16%), immobility (16%), connective tissue disease (16%), heart dis. (10%), old age (10%), and preg/pelvic dis. (8%) The results, of lung perfusion scan were HPPE 40 cases(26.8 %), IPPE 21 cases(14.1%), LPPE 88 cases (59.1%), and cases(%) of treatment in these cases were HPPE 34 cases(85%), IPPE 9 cases(42.9%), LPPE 0 case(0.0%). Treatments were heparin and warfarin (69.5%), heparin alone (8.2%), warfarin alone (2.0%), embolectomy (4.1%), thrombolytics (2.0%), IVC filter (2.0%), and no treatment (12.2%) In 34 cases (69.4%), follow up could be done, and 5 cases were recurred (10.2%). The causes of recurrence was incomplete anticoagulant therapy (3 cases) and recurrence of predisposing factor (2 cases). Expired case due to pulmonary embolism was one who was expired just before trial of thrombolytic therapy. Conclusion : Efforts should be made to shorten the interval from onset of Sx to Dx, ie, high index of suspision.

  • PDF

Comparison of $Na^+/I^-$ Symporter Expression Rate in Malignant and Benign Thyroid Diseases: Immunohistochemical Study (악성 및 양성 갑상선 질환의 조직에서 면역조직학적 검사법에 의한 $Na^+/I^-$ symporter의 발현율 비교)

  • Kang, Do-Young;Jeong, Young-Jin;Lee, Kyung-Eun;Park, Heon-Soo;Yoo, Young-Hyun;Roh, Mee-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • Purpose: Previous studies have not showed consistent results for the level of expression of sodium/iodide symporter (NIS) in thyroid diseases, especially malignant tumor. We undertook this study to evaluate the distribution of NIS expression in malignant thyroid diseases and compare with that in benign thyroid disease. Materials and Methods: Total patients were 119 cases (Men 15, $48{\pm}13$ yrs). Total number of samples were 205 pieces. In malignant thyroid disease, there were 153 samples: 90 in papillary carcinoma, 4 in follicular carcinoma, 2 in medullary carcinoma and 57 in metastatic lymph node. In benign thyroid disease, there were 52 samples: 36 in goiter/cyst, 11 in thyroiditis and 5 in follicular adenoma. Using immunohistochemical methods, we probed 205 samples with monoclonal anti-NIS Ab. Grading of staining was stored as 0 (negative or absent), 1 (weakly positive), 2 (moderately positive) or 3 (strongly positive). Expression rate (ER) of NIS positivity in individual disease entity was expressed as percentage of total number divided by number in 2 plus 3 grade. Results: ERs of malignant thyroid diseases were 63% in papillary carcinoma, 81% in metastatic lymph node, 71% in follicular carcinoma and 100% in medullary carcinoma. ERs of benign thyroid disease were 53% in goiter/cyst, 64% in thyroiditis and 40% in follicular adenoma. ER of malignant thyroid diseases was higher than benign thyroid diseases (71% vs 54%). Grading of NIS expression in papillary carcinoma or goiter/cyst was heterogeneously distributed in considerable cases. Normal tissue also showed heterogeneous distribution of NIS expression, which was not correlated with that of primary lesion. Conclusion: In papillary thyroid carcinoma, distribution of NIS expression was heterogeneous and increased, and not different compared with that of benign thyroid disease.

The Clinicopathological Factors That Determine a Local Recurrence of Rectal Cancers That Have Been Treated with Surgery and Chemoradiotherapy (직장암의 수술 후 방사선 치료 시 국소 재발의 임상 병리적 예후 인자)

  • Choi, Chul-Won;Kim, Min-Suk;Lee, Seung-Sook;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Seo, Young-Seok;Hwang, Dae-Yong;Moon, Sun-Mi;Kim, Mi-Sook
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.255-262
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate the pathological prognostic factors related to local recurrence after radical surgery and adjuvant radiation therapy in advanced rectal cancer. $\underline{Materials\;and\;Methods}$: Fifty-four patients with advanced rectal cancer who were treated with radical surgery followed by adjuvant radiotherapy and chemotherapy between February 1993 and December 2001 were enrolled in this study. Among these patients, 14 patients experienced local recurrence. Tissue specimens of the patients were obtained to determine pathologic parameters such as histological grade, depth of invasion, venous invasion, lymphatic invasion, neural invasion and immunohistopathological analysis for expression of p53, Ki-67, c-erb, ezrin, c-met, phosphorylated S6 kinase, S100A4, and HIF-1 alpha. The correlation of these parameters with the tumor response to radiotherapy was statistically analyzed using the chi-square test, multivariate analysis, and the hierarchical clustering method. $\underline{Results}$: In univariate analysis, the histological tumor grade, venous invasion, invasion depth of the tumor and the over expression of c-met and HIF-1 alpha were accompanied with radioresistance that was found to be statistically significant. In multivariate analysis, venous invasion, invasion depth of tumor and over expression of c-met were also accompanied with radioresistance that was found to be statistically significant. By analysis with hierarchical clustering, the invasion depth of the tumor, and the over expression of c-met and HIF-1 alpha were factors found to be related to local recurrence. Whereas 71.4% of patients with local recurrence had 2 or more these factors, only 27.5% of patients without local recurrence had 2 or more of these factors. $\underline{Conclusion}$: In advanced rectal cancer patients treated by radical surgery and adjuvant chemo-radiation therapy, the poor prognostic factors found to be related to local recurrence were HIF-1 alpha positive, c-met positive, and an invasion depth more than 5.5 mm. A prospective study is necessary to confirm whether these factors would be useful clinical parameters to measure and predict a radio-resistance group of patients.

Effect of Reperfusion after 20 min Ligation of the Left Coronary Artery in Open-chest Bovine Heart: An Ultrastructural Study (재관류가 허혈 심근세포의 미세구조에 미치는 영향 : 재관류 손상에 관한 연구)

  • 이종욱;조대윤;손동섭;양기민;라봉진;김호덕
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.739-748
    • /
    • 1998
  • Background: It has been well documented that transient occlusion of the coronary artery causes myocardial ischemia and finally cell death when ischemia is sustained for more than 20 minutes. Extensive studies have revealed that ischemic myocardium cannot recover without reperfusion by adequate restoration of blood flow, however, reperfusion can cause long-lasting cardiac dysfunction and aggravation of structural damage. The author therefore attempted to examine the effect of postischemic reperfusion on myocardial ultrastructure and to determine the rationales for recanalization therapy to salvage ischemic myocardium. Materials and methods: Young Holstein-Friesian cows(130∼140 Kg body weight; n=40) of both sexes, maintained with nutritionally balanced diet and under constant conditions, were used. The left anterior descending coronary artery(LAD) was occluded by ligation with 4-0 silk snare for 20 minutes and recanalized by release of the ligation under continuous intravenous drip anesthesia with sodium pentobarbital(0.15 mg/Kg/min). Drill biopsies of the risk area (antero-lateral wall) were performed at just on reperfusion(5 minutes), 1-, 2-, 3-, 6-, 12-hours after recanalization, and at 1-hour assist(only with mechanical respiration and fluid replacement) after 12-hour recanalization. The materials were subdivided into subepicardial and subendocardial tissues. Tissue samples were examined with a transmission electron microscope (Philips EM 300) at the accelerating voltage of 60 KeV. Results: After a 20-minute ligation of the LAD, myocytes showed slight to moderate degree of ultrastructural changes including subsarcolemmal bleb formation, loss of nuclear matrix, clumping of chromatin and margination, mitochondrial destruction, and contracture of sarcomeres. However, microvascular structures were relatively well preserved. After 1-hour reperfusion, nuclear and mitochondrial matrices reappeared and intravascular plugging by polymorphonuclear leukocytes or platelets was observed. However, nucleoli and intramitochondrial granules reappeared within 3 hours of reperfusion and a large number of myocytes were recovered progressively within 6 hours of reperfusion. Recovery was apparent in the subepicardial myocytes and there were no distinct changes in the ultrastructure except narrowed lumen of the microvessels in the later period of reperfusion. Conclusions: It is likely that the ischemic myocardium could not be salvaged without adequate restoration of coronary flow and that the microvasculature is more resistant to reversible period of ischemia than subendocardium and subepicardium. Therefore, thrombolysis and/or angioplasty may be a rational method of therapy for coronarogenic myocardial ischemia. However, it may take a relatively longer period of time to recover from ischemic insult and reperfusion injury should be considered.

  • PDF

Evaluation on Usefulness of Abdomen and Chest Motion Control Device (ABCHES) for the Tumor with a Large Respiratory Motion in Radiotherapy (호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdomen and Chest Motion Control Device (ABCHES)의 유용성 평가)

  • Cho, Yoon-Jin;Jeon, Mi-Jin;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Sook;Im, Jung-Ho;Lee, Ik-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: It is essential to minimize the respiratory-induced motion of involved organs in the Tomotherapy for tumor located in the chest and abdominal region. However, the application of breathing control system to Tomotherapy is limited. This study was aimed to investigate the possible application of the ABCHES system and its efficacy as a means of breathing control in the tomotherapy treatment. Materials and Methods: Five subjects who were treated with a Hi-Art Tomotherapy system for lung, liver, gallbladder and pancreatic tumors. All patients undertook trained on two breathing methodes using an ABCHES, free breathing methode and shallow breathing methode. When the patients could carry out the breathing control, 4D-CT scan was a total of 10 4D tomographic images were acquired. A radiologist resident manually drew the tumor region, including surrounding nomal organs, on each of CT images at the inhalation phase, the exhalation phase and the 40% phase (mid-inhalation) and average CT image. Those CT images were then exported to the Tomotherapy planning station. Data exported from the Tomotherapy planning station was analyzed to quantify characteristics of dose-volume histograms and motion of tumors. Organ motions under free breathing and shallow breathing were examined six directions, respectively. Radiation exposure to the surrounding organs were also measured and compared. Results: Organ motion is in the six directions with more than a 5 mm displacement. A total of 12 Organ motions occurred during free breathing while organ motions decreased to 2 times during shallow breathing under the use of Abches. Based on the quantitative analysis of the dose-volume histograms shallow breathing showed lower resulting values, compared to free breathing, in every measure. That is, treatment volume, the dose of radiation to the tumor and two surrounding normal organs (mean doses), the volume of healthy tissue exposed to radiation were lower at the shallow breathing state. Conclusion: This study proposes that the use of ABCHES is effective for the Tomotherapy treatment as it makes shortness of breathing easy for patients. Respiratory-induced tumor motion is minimized, and radiation exposure to surrounding normal tissues is also reduced as a result.

  • PDF

Effect of a Needle Aspiration in Patients with Lymphedema (암 수술 후 발생한 림프부종 환자의 바늘 흡인술 효과)

  • Yang, Gu-Hwan;Kwak, Sung-Wook;Kim, Sun-Hyn;Shin, Young-Tae;Hwang, Hee-Jin;Park, No-Hyeok;Yeom, Chang-Hwan
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • Purpose: Lymphedemas are tissue fluid swellings, usually on the arms or legs, and occur as a result of impaired lymphatic drainage. Presently, the most effective treatment available is complete decongestive physiotherapy (CDP). However, this therapy is ineffective in some patients and surgery may be indicated. Herein, we examined the efficacy of minimally invasive needle aspiration of the most enlarged areas in hypodermic adipose tissues, of patients who had failed CDP. Methods: We included 21 patients who were diagnosed with lymphedema stage II-III in the upper or lower extremities and visited the lymphedema clinic at a university hospital from September 1, 2003 to February 28, 2004. All patients had been treated with CDP at least once, but had failed to respond to the therapy for more than one year. Nine patients had breast cancer and 12 had cervical cancer. We identified the area with the most severe edema by using MRI and performed a 16-gauge angio-needle aspiration on the area. The patients were followed up for 3 months. Effectiveness of the treatment was evaluated by comparing the volume of edema before and after the treatment using Wilcoxon signed rank-test. Results: The mean reduction ratio of the volume of edema comparison normal volume was 41.1${\pm}$35.3% (P=0.001). There were no major or minor operative complications except localized hemorrhage. Conclusion: We conclude that a needle aspiration prior to other surgical treatments is relatively safe and effective for those patients who are unresponsive to CDP.

  • PDF

The Investigation Regarding the Dose Change due to the Heterogeneity of Prostate Cancer Treatment with IMRT (전립선암의 세기조절 방사선치료 시 불균질부에 의한 선량변화에 관한 고찰)

  • Yoon, Il-Kyu;Park, Jang-Pil;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Purpose: The pelvic phantom was fabricated in the following purposes: (1) Dose verification of IMRT plan using Eclipse planning computer, (2) to study the interface effect at the interface between rectal wall and air. The TLD can be inserted in the pelvic phantom to confirm the dose distribution as well as uncertainty at the interface. Materials and Methods: A pelvic phantom with the dimension of 30 cm diameter, 20 cm height and 20 cm thickness was fabricated to investigate the dose at the rectal wall. The phantom was filled with water and has many features like bladder, rectum, and prostate and seminal vesicle (SV). The rectum is made of 3 cm-dimater plastic pipe, and it cab be blocked by using a plug, and film can be inserted around the rectal wall. The phantom was scanned with Philips Brillance scanner and various organs such as prostate, SV, and rectal wall, and bladder wall were delineated. The treatment parameters used in this study are the same as those used in the protocols in the SNUH. TLD chips are inserted to the phantom to evaluate the dose distribution to the rectal wall (to simulate high dose gradient region), bladder wall and SV (to simulate the high dose region) and 2 spots in anterior surface (to simulate the low dose region). The TLD readings are compared with those of the planning computer (ECLIPSE, Varian, USA). Results: The target TLD doses represented as the prostate and SV show excellent agreements with the doses from the RTP within +/-3%. The rectal wall doses measured at the rectal wall are different from the those of the RTP by -11%. This is in literatures called as an interface effect. The underdosages at the rectal wall is independent of 3 heterogeneity correction algorithm in the Eclipse RTP. Also the low dose regions s represented as surface in this study were within +/-1%. Conclusion: The RTP estimate the dosage very accurately withihn +/-3% in the high dose (SV, or prostate) and low dose region (surface). However, the dosage at the rectal wall differed by as much as 11% (In literatures, the underdosage of 9$\sim$15% were reported). This range of errors occurs at the interface, for example, at the interface between lung and chest wall, or vocal cord. This interface effect is very important in clinical situations, for example, to estimate the NTCP (normal tissue complication probability) and to estimate the limitations of the current RTP system. Monte-carlo-based RTP will handle this issue correctly.

  • PDF

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF