• Title/Summary/Keyword: Tissue expansion

검색결과 195건 처리시간 0.027초

Therapeutic Intervention of Aggregate Formation in Huntington's Disease: A Potential Role of Tissue Transglutaminase (tTG)

  • Chun, Wan-Joo
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.65-66
    • /
    • 2003
  • The cause of Huntington's disease (HD) is a pathological expansion of the polyglutamine domain within the N-terminal region of huntingtin. Neuronal aggregates composed of mutant huntingtin within certain neuronal populations are a characteristic hallmark of HD. Because tissue transglutaminase (tTG) cross-links proteins into aggregates and polypeptide-bound glutamines are primary determining factors for tTG-catalyzed reactions, it has been hypothesized that tTG may contribute to the formation of aggregates. (omitted)

  • PDF

소아 환자에서 조직확장기 사용의 유용성 (Usefulness of using Tissue Expander in Pediatric Patient)

  • 이준우;박철규;박종림;김용규
    • Archives of Plastic Surgery
    • /
    • 제37권6호
    • /
    • pp.763-768
    • /
    • 2010
  • Purpose: Reconstruction of soft tissue defect using tissue expander can provide better flap which is more similar to surrounding tissue in color, skin texture and hair compared to other methods. Many pediatric patients need reconstruction of soft tissue defect because of giant congenital nevi, congenital or acquired malformations and burn scars. Reconstruction using tissue expander is adequate to minimize dysmorphism in these patients. We intended to assess outcomes of using tissue expander in pediatric patients by retrospective study. Methods: Total cases were 168 of pediatric patients who received soft tissue reconstruction using tissue expander by the same surgeon from February, 1982 to May, 2009. All patients who received soft tissue reconstruction were under 10 years old. Mean age was 4.3 years old, the youngest 13 months, the oldest 8 years. Eightynine cases were male and 79 cases were female. Most common cause was giant hairy nevi (67 cases, 39.9%), secondary cause was burn scar/scar contracture (61 cases, 36.3%). Trunk (38 cases, 22.6%) was most common anatomical location. Results: Soft tissue defects were successfully covered using tissue expander in 149 cases (88.7%) without major complications. There was infection on 8 cases (4.7%) and we treated by adequate antibiotics in these cases. There were tissue expander folding or valve displacement on 5 cases (3%). Conclusion: Usage of tissue expander is useful on pediatric patients because tissue expansion is rapid on children and there are less secondary contractures on operation site than full thickness skin graft. Because of psychological stress due to tissue expander, operation should be performed before school age.

Improvement of fibrosed scar tissue elongation using self-inflatable expander

  • Jung, Gyu-Un;Kim, Jin-Woo;Pang, Eun-Kyoung;Kim, Sun-Jong
    • 대한치과의사협회지
    • /
    • 제54권7호
    • /
    • pp.501-512
    • /
    • 2016
  • We evaluated a self-inflatable osmotic tissue expander for its utility in creating sufficient soft tissue elongation for primary closure after bone grafting. Six patients with alveolar defects who required vertical augmentation of >6 mm before implant placement were enrolled. All had more than three prior surgeries, and flap advancement for primary coverage was restricted by severely fibrosed scars. Expanders were inserted beneath the flap and fixed with a screw. After 4 weeks, expander removal and bone grafting were performed simultaneously. A vertical block autograft and guided bone regeneration and distraction osteogenesis were performed. Expansion was sufficient to cover the grafted area without additional periosteal incision. Complications included mucosal perforation and displacement of the expander. All augmentation procedures healed uneventfully and the osseous implants were successfully placed. The tissue expander may facilitate primary closure by increasing soft tissue volume. In our experience, this device is effective, rapid, and minimally invasive, especially in fibrous scar tissue.

  • PDF

Host-Microbe Interactions Regulate Intestinal Stem Cells and Tissue Turnover in Drosophila

  • Ji-Hoon Lee
    • International Journal of Stem Cells
    • /
    • 제17권1호
    • /
    • pp.51-58
    • /
    • 2024
  • With the activity of intestinal stem cells and continuous turnover, the gut epithelium is one of the most dynamic tissues in animals. Due to its simple yet conserved tissue structure and enteric cell composition as well as advanced genetic and histologic techniques, Drosophila serves as a valuable model system for investigating the regulation of intestinal stem cells. The Drosophila gut epithelium is in constant contact with indigenous microbiota and encounters externally introduced "non-self" substances, including foodborne pathogens. Therefore, in addition to its role in digestion and nutrient absorption, another essential function of the gut epithelium is to control the expansion of microbes while maintaining its structural integrity, necessitating a tissue turnover process involving intestinal stem cell activity. As a result, the microbiome and pathogens serve as important factors in regulating intestinal tissue turnover. In this manuscript, I discuss crucial discoveries revealing the interaction between gut microbes and the host's innate immune system, closely associated with the regulation of intestinal stem cell proliferation and differentiation, ultimately contributing to epithelial homeostasis.

A Simple, Reliable, and Inexpensive Intraoperative External Expansion System for Enhanced Autologous Structural Fat Grafting

  • Oranges, Carlo M.;Tremp, Mathias;Ling, Barbara;Wettstein, Reto;Largo, Rene D.;Schaefer, Dirk J.
    • Archives of Plastic Surgery
    • /
    • 제43권5호
    • /
    • pp.466-469
    • /
    • 2016
  • External volume expansion of the recipient site by suction has been proposed as a way of improving fat graft survival. The objective of this study was to present an innovative and simple intraoperative external expansion system to enhance small-volume autologous fat grafting (40-80 mL) and to discuss its background and its mechanism of action. In this system, expansion is performed using a complete vacuum delivery system known as the Kiwi VAC-6000M with a PalmPump (Clinical Innovations). The recipient site is rapidly expanded intraoperatively 10 times for 30 seconds each with a negative pressure of up to 550 mm Hg before autologous fat injection. During this repetitive stimulation, the tissues become grossly expanded, developing macroscopic swelling that regresses slowly over the course of hours following the cessation of the stimulus. The system sets various mechanisms in motion, including scar release, mechanical stimulation, edema, ischemia, and inflammation, which provide an environment conducive for cell proliferation and angiogenesis. In order to maintain the graft construct in its expansive state, all patients are encouraged postoperatively to use the Kiwi three times daily for one minute per session over the course of three days. The handling of this system is simple for both the patients and the surgeon. Satisfactory clinical outcomes have been achieved without significant complications.

조직확장술을 거치지 않고 유방보형물을 대흉근-전거근 포켓에 삽입한 즉시 유방재건술 (Immediate Breast Reconstruction Placing the Breast Implant under the Pectoralis Major-Serratus Anterior Pocket without Tissue Expansion)

  • 김훈;엄진섭;안세현;손병호;이택종
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.622-627
    • /
    • 2007
  • Purpose: Although the autogenous tissue transfer has been the mainstay of the breast reconstruction, concern for the donor site morbidity can lead to the superseded method using tissue expander with implant or permanent expander-implant. However, the additional procedure of tissue expansion possibly cause discomfort and raise the cost. We tried to verify the efficacy of using the saline-filled breast implant by itself for the safe and convenient immediate breast reconstruction modality if the patients have small, round and non-ptotic breasts and the sufficient breast skin can be saved with mastectomy. Methods: From July 2002 to July 2005, 29 breasts of 26 patients were restored only with the saline-filled breast implant immediately after the skin sparing or nipple-areolar skin sparing mastectomy in Asan Medical Center. A pocket with pectoralis major and serratus anterior muscle was created and the implant was covered with this muscle pocket. Simultaneous contralateral augmentation was performed in patients whose mastectomy specimen weighed less than 100g. Results: Using only the saline-filled breast implant resulted in the successful reconstruction with few complications including partial necrosis of nipple areolar skin (five cases, 17.2%), capsular contracture (three cases, 10.3%), hematoma (one case, 3.4%), depigmentation of areolar skin (one case, 3.4%), hypertrophic scar (one case, 3.4%), which were all healed by conservative management. There were no significant complications such as implant exposure and subsequent removal. Conclusion: Immediate breast reconstruction only with the saline-filled breast implant can be a satisfactory alternative option for the patients whose breast is small, round and non-ptotic, especially when the nipple-areolar skin of the breast is preserved in the mastectomy.

Applicability and Safety of in Vitro Skin Expansion Using a Skin Bioreactor: A Clinical Trial

  • Jeong, Cheol;Chung, Ho Yun;Lim, Hyun Ju;Lee, Jeong Woo;Choi, Kang Young;Yang, Jung Dug;Cho, Byung Chae;Lim, Jeong Ok;Yoo, James J.;Lee, Sang Jin;Atala, Anthony J.
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.661-667
    • /
    • 2014
  • Background Tissue expansion is an effective and valuable technique for the reconstruction of large skin lesions and scars. This study aimed to evaluate the applicability and safety of a newly designed skin expanding bioreactor system for maximizing the graft area and minimizing the donor site area. Methods A computer-controlled biaxial skin bioreactor system was used to expand skin in two directions while the culture media was changed daily. The aim was to achieve an expansion speed that enabled the skin to reach twice its original area in two weeks or less. Skin expansion and subsequent grafting were performed for 10 patients, and each patient was followed for 6 months postoperatively for clinical evaluation. Scar evaluation was performed through visual assessment and by using photos. Results The average skin expansion rate was $10.54%{\pm}6.25%$; take rate, $88.89%{\pm}11.39%$; and contraction rate, $4.2%{\pm}2.28%$ after 6 months. Evaluation of the donor and recipient sites by medical specialists resulted in an average score of 3.5 (out of a potential maximum of 5) at 3 months, and 3.9 at 6 months. The average score for patient satisfaction of the donor site was 6.2 (out of a potential maximum of 10), and an average score of 5.2 was noted for the recipient site. Histological examination performed before and after the skin expansion revealed an increase in porosity of the dermal layer. Conclusions This study confirmed the safety and applicability of the in vitro skin bioreactor, and further studies are needed to develop methods for increasing the skin expansion rate.

Characteristics of adhesion areas between the tissue expander and capsule in implant-based breast reconstruction

  • Lim, Yoon Min;Park, Kwang Hyun;Lee, Dong Won;Lew, Dae Hyun;Roh, Tai Suk;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.330-335
    • /
    • 2019
  • Background The use of anatomic implants has improved the aesthetic results of breast surgery; however, implant malrotation is an uncommon, but serious complication of these procedures. Nevertheless, little research has explored implant adhesion. In this study, we investigated adhesion between the expander and the capsule. Methods Seventy-nine cases of immediate breast reconstruction via two-stage implant-based reconstruction performed between September 2016 and November 2017 were evaluated. Mentor CPX4 expanders were used in 14 breasts, and Natrelle expanders in 65. We analyzed areas of adhesion on the surfaces of the tissue expanders when they were exchanged with permanent implants. We investigated whether adhesions occurred on the cephalic, caudal, anterior, and/or posterior surfaces of the expanders. Results Total adhesion occurred in 18 cases, non-adhesion in 15 cases, and partial adhesion in 46 cases. Of the non-adhesion cases, 80% (n=12) were with Mentor CPX4 expanders, while 94.4% (n=17) of the total adhesion cases were with Natrelle expanders. Of the partial adhesion cases, 90.7% involved the anterior-cephalic surface. The type of tissue expander showed a statistically significant relationship with the number of attachments in both univariate and multivariate logistic regression analyses (P<0.001) and with total drainage only in the univariate analysis (P=0.015). Conclusions We sought to identify the location(s) of adhesion after tissue expander insertion. The texture of the implant was a significant predictor of the success of adhesion, and partial adhesion was common. The anterior-cephalic surface showed the highest adhesion rate. Nevertheless, partial adhesion suffices to prevent unwanted rotation of the expander.

A novel technique for large and ptotic breast reconstruction using a latissimus dorsi myocutaneous flap set at the posterior aspect, combined with a silicone implant, following tissue expander surgery

  • Ishii, Naohiro;Ando, Jiro;Shimizu, Yusuke;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • 제45권5호
    • /
    • pp.484-489
    • /
    • 2018
  • Large and ptotic breast reconstruction in patients who are not candidates for a transverse rectus abdominalis myocutaneous flap and revision surgery for the contralateral breast remains challenging. We developed a novel breast reconstruction technique using a latissimus dorsi myocutaneous (LD m-c) flap set at the posterior aspect of the reconstructed breast, combined with an anatomical silicone breast implant (SBI), following tissue expander surgery. We performed the proposed technique in four patients, in whom the weight of the resected tissue during mastectomy was >500 g and the depth of the inframammary fold (IMF) was >3 cm. After over-expansion of the lower portion of the skin envelope by a tissue expander, the LD m-c flap was transferred to cover the lower portion of the breast defect and to achieve a ptotic contour, with the skin paddle set at the posterior aspect of the reconstructed breast. An SBI was then placed in the rest of the breast defect after setting the LD m-c flap. No major complications were observed during the follow-up period. The proposed technique resulted in symmetrical and aesthetically satisfactory breasts with deep IMFs, which allowed proper fitting of the brassiere, following large and ptotic breast reconstruction.