• Title/Summary/Keyword: Tissue displacement

Search Result 185, Processing Time 0.03 seconds

Maxillary complete denture fabrication cases with posterior palatal seal considering palatal form and tissue displacement (구개 형태 및 조직 변위를 고려하여 후방 구개 폐쇄를 형성한 상악 총의치 제작 증례)

  • Kim, Seon-A;Son, Mee-Kyung;Heo, Yu-Ri
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.152-159
    • /
    • 2022
  • The role of the posterior palatal seal is important in retention of the maxillary complete denture. After taking the final impression, additional retention can be given to the maxillary denture through a mechanical method of forming a groove on master cast, but this is often overlooked in the clinical process. As a result, the posterior palatal seal is formed in a uniform way by the technician without considering the individual characteristics of the patient. Until now, various types of posterior palatal seal have been introduced by many people. This case report describes the process of manufacturing the maxillary complete denture by determining the position and form of an appropriate posterior palatal seal after considering the patient's anatomical palatal form and tissue displacement during function.

Stiffness Comparison of Tissue Phantoms using Optical Coherence Elastography without a Load Cell

  • Chae, Yu-Gyeong;Park, Eun-Kee;Jeon, Min Yong;Jeon, Byeong-Hwan;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.17-22
    • /
    • 2017
  • Mechanical property of tissue is closely related to diseases such as breast cancer, prostate cancer, cirrhosis of the liver, and atherosclerosis. Therefore measurement of tissue mechanical property is important for a better diagnosis. Ultrasound elastography has been developed as a diagnostic modality for a number of diseases that maps mechanical property of tissue. Optical coherence elastography (OCE) has a higher spatial resolution than ultrasound elastography. OCE, therefore, could be a great help for early diagnosis. In this study, we made tissue phantoms and measured their compressive moduli with a rheometer measuring the response to applied force. Uniaxial strain of the tissue phantom was also measured with OCE by using cross-correlation of speckles and compared with the results from the rheometer. In order to compare stiffness of tissue phantoms by OCE, the applied force should be measured in addition to the strain. We, however, did not use a load cell that directly measures the applied force for each sample. Instead, we utilized one silicone film (called as reference phantom) for all OCE measurements that indirectly indicated the amount of the applied force by deformation. Therefore, all measurements were based on displacement, which was natural and effective for image-based elastography such as OCE.

Effect of disc displacement on the bony change and disc configuration of TMJ (악관절 관절원판 위치변화가 관절원판 형태 및 골변화에 미치는 영향)

  • Kim Jin-Hoa;Lee Wan;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Purpose : The objective of this study was to investigate the effect of TMJ disc displacement on the TMJ disc configuration and surrounding osseous structure. Materials and Methods : The proton density and 72-weighted MR images of 57 TMJs were retrospectively studied. These TMJs were divided into three groups according to the anterior disc displacement status on MR sagittal images, those were the normal, anterior disc displacement with reduction (ADWR), anterior disc displacement without reduction (ADWOR). The frequency of disc configuration and surrounding bony change, the border status between articular disc and retrodiscal tissue were investigated according to the positional change of articular disc. Results : There were significant statistical differences of chi-square statistics of TMJ disc configurational type between normal and ADWR/ADWOR group, respectively. Surrounding bony change frequently appeared in ADWOR and a statistically significant difference of chi-square statistics of bony change frequency between normal and ADWOR group was observed. Conclusion : These results suggested that the disc configuration and bony change of TMJ are strongly related to TMJ disc displacement.

  • PDF

Usefulness of using Tissue Expander in Pediatric Patient (소아 환자에서 조직확장기 사용의 유용성)

  • Lee, Jun-Woo;Park, Chul-Gyoo;Park, Jong-Lim;Kim, Yong-Kyu
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.763-768
    • /
    • 2010
  • Purpose: Reconstruction of soft tissue defect using tissue expander can provide better flap which is more similar to surrounding tissue in color, skin texture and hair compared to other methods. Many pediatric patients need reconstruction of soft tissue defect because of giant congenital nevi, congenital or acquired malformations and burn scars. Reconstruction using tissue expander is adequate to minimize dysmorphism in these patients. We intended to assess outcomes of using tissue expander in pediatric patients by retrospective study. Methods: Total cases were 168 of pediatric patients who received soft tissue reconstruction using tissue expander by the same surgeon from February, 1982 to May, 2009. All patients who received soft tissue reconstruction were under 10 years old. Mean age was 4.3 years old, the youngest 13 months, the oldest 8 years. Eightynine cases were male and 79 cases were female. Most common cause was giant hairy nevi (67 cases, 39.9%), secondary cause was burn scar/scar contracture (61 cases, 36.3%). Trunk (38 cases, 22.6%) was most common anatomical location. Results: Soft tissue defects were successfully covered using tissue expander in 149 cases (88.7%) without major complications. There was infection on 8 cases (4.7%) and we treated by adequate antibiotics in these cases. There were tissue expander folding or valve displacement on 5 cases (3%). Conclusion: Usage of tissue expander is useful on pediatric patients because tissue expansion is rapid on children and there are less secondary contractures on operation site than full thickness skin graft. Because of psychological stress due to tissue expander, operation should be performed before school age.

Improvement of fibrosed scar tissue elongation using self-inflatable expander

  • Jung, Gyu-Un;Kim, Jin-Woo;Pang, Eun-Kyoung;Kim, Sun-Jong
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.501-512
    • /
    • 2016
  • We evaluated a self-inflatable osmotic tissue expander for its utility in creating sufficient soft tissue elongation for primary closure after bone grafting. Six patients with alveolar defects who required vertical augmentation of >6 mm before implant placement were enrolled. All had more than three prior surgeries, and flap advancement for primary coverage was restricted by severely fibrosed scars. Expanders were inserted beneath the flap and fixed with a screw. After 4 weeks, expander removal and bone grafting were performed simultaneously. A vertical block autograft and guided bone regeneration and distraction osteogenesis were performed. Expansion was sufficient to cover the grafted area without additional periosteal incision. Complications included mucosal perforation and displacement of the expander. All augmentation procedures healed uneventfully and the osseous implants were successfully placed. The tissue expander may facilitate primary closure by increasing soft tissue volume. In our experience, this device is effective, rapid, and minimally invasive, especially in fibrous scar tissue.

  • PDF

Finite Element Analysis of End-to-End Anastomosis of Coronary Artery with Elastic Surrounding Tissue (탄성경계조직을 가진 관상동맥의 end-to-end 문합에 대한 유한요소해석)

  • Han, Geun-Jo;Kim, Tae-Hyung;Ahn, Sung-Chan;Shim, Jae-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.442-447
    • /
    • 2001
  • A finite element analysis of end-to-end artery/PTFE anastomosis has been presented in this study to evaluate the distribution of compliance in the vicinity of the anastomosis due to any mismatch in compliance characteristics. But, In these studies it was assumed that the artery and PTFE have the simple cylindrical shape representing the fatty tissue surrounding the coronary artery. And the fatty tissue was considered as the elastic surrounding materials in the finite element analysis. The simulation results were obtained as follows : 1. A fatty tissue was effect to reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis of different material because a hypercompliant zone become narrorw and a compliance discrepancy decrease between the artery and the PTFE about 70%. And radial direction displacement distribution with respect to distance in the vicinity of a artery/PTFE anastomosis was similiar. 2. The variation of PTFE thckness reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis about 25%.

  • PDF

DISTRIBUTION IN FIBRONECTIN OF THE RABBIT TEMPOROMANDIBULAR JOINT TISSUES FOLLOWING SURGICAL INDUCTION OF ANTERIOR DISK DISPLACEMENT : IMMUNOHISTOCHEMICAL STUDY (악관절원판의 인위적 전방변위술시행후 악관절구성조직에서 Fibronectin의 분포변화)

  • Kim, Uk-Kyu;Chung, In-Kyo;Park, Bong-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.337-349
    • /
    • 1999
  • The extracellular matrix(ECM) is a complex network of different combination of collagens, glycosaminoglycans, laminin, fibronectin, and many other glycoproteins including proteolytic enzymes. The composition and organization of the ECM contributes to the uniques physical or biomechanical properties of a tissue. Fibronectins(FN) are dimeric glycoproteins located on cell surfaces, in the matrix of connective tissue, and in blood. Fibronectins mediate cell attachment to collagen substratum and have been implicated in a variety of important biological processes, including embryogenesis and cell differentiation. The purpose of this study was to determine the effects of surgical induction of anterior disk displacement(ADD) on distribution of fibronectin in the rabbit temporomandibular joint(TMJ) tissues included the articular cartilage, disc, retrodiscal tissue, articular eminence using an immunohistochemical technique. The left TMJ was exposed surgically, and all discal attachments were severed except for the posterior attachment. The disk was then repositioned anteriorly and sutured to the zygomatic arch. The right TMJ served as a shamoperated control. Normal joints were used as a nonoperated control. Fourty-five rabbits were used for experiments in total. For fibronectin immunohistochemical study, eighteen rabbits (one normal group and 5 experimental groups, each group consists of 3 rabbits) were used. The experimental rabbits were sacrified after operation period of 2, 3, 4, 6 and 8 weeks on fibronectin. The obtained results were as follows ; 1. Fibronectin immunoreaction on all TMJ tissues(mandibular condyle, articular disc, retrodiscal tissue, articular eminence) in the normal rabbit was observed. Especially the reverse cell layer and proliferation zone of articular cartilage of condyle show strong positive reaction. 2. Depletion of fibronectin in the all TMJ tissues except hypertrophic zone of articular cartilage occurred at 2 weeks following induction of ADD. 3. The restoration of immunoreaction at 4 weeks was observed and a progressive increasing reaction at 6 weeks, 8 weeks also was found. Our study generally showed degenerative changes in TMJ tissues after ADD although TMJ tissues adapted or degenerated to abnormal loads and stress distribution according to the remodeling capacity of TMJ tissues.

  • PDF

Rotation Control of Shoulder Joint During Shoulder Internal Rotation: A Comparative Study of Individuals With and Without Restricted Range of Motion

  • Min-jeong Chang;Jun-hee Kim;Ui-jae Hwang;Il-kyu Ahn;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2024
  • Background: Limitations of shoulder range of motion (ROM), particularly shoulder internal rotation (SIR), are commonly associated with musculoskeletal disorders in both the general population and athletes. The limitation can result in connective tissue lesions such as superior labrum tears and symptoms such as rotator cuff tears and shoulder impingement syndrome. Maintaining the center of rotation of the glenohumeral joint during SIR can be challenging due to the compensatory scapulothoracic movement and anterior displacement of the humeral head. Therefore, observing the path of the instantaneous center of rotation (PICR) using the olecranon as a marker during SIR may provide valuable insights into understanding the dynamics of the shoulder joint. Objects: The aim of the study was to compare the displacement of the olecranon to measure the rotation control of the humeral head during SIR in individuals with and without restricted SIR ROM. Methods: Twenty-four participants with and without restricted SIR ROM participated in this study. The displacement of olecranon was measured during the shoulder internal rotation control test (SIRCT) using a Kinovea (ver. 0.8.15, Kinovea), the 2-dimensional marker tracking analysis system. An independent t-test was used to compare the horizontal and vertical displacement of the olecranon marker between individuals with and without restricted SIR ROM. The statistical significance was set at p < 0.05. Results: Vertical displacement of the olecranon was significantly greater in the restricted SIR group than in the control group (p < 0.05). However, no significant difference was observed in the horizontal displacement of the olecranon (p > 0.05). Conclusion: The findings of this study indicated that individuals with restricted SIR ROM had significantly greater vertical displacement of the olecranon. The results suggest that the limitation of SIR ROM may lead to difficulty in rotation control of the humeral head.

A STUDY ON THE MECHANICAL BEHAVIORS OF ABUTMENT TEETH AND SUPPORTING TISSUE OF THE TELESCOPE DENTURE BY THE FINITE ELEMENT METHOD (유한요소법(有限要素法)에 의(依)한 Telescope Denture의 지대치(支臺齒) 및 지지조직(支持組織)의 역학적(力學的) 반응(反應)에 관(關)한 연구(硏究))

  • Kim, Moon-Ki;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.109-122
    • /
    • 1984
  • The purpose of this study was to analyze the magnitude and mode of the stress distribution induced in the supporting alveolar bone and periodontal ligament and, to determine the displacement of abutment teeth and telescope denture base by applying chewing force to the telescope denture quantitatively and qualitatively. Two finite element models of telescope denture that were restored the missing mandibular second molar with two abutment teeth which were constructed. In two different models, parallel and tapering type telescope crowns were constructed. These finite element models of two cases used for these experiment were a two-dimensional mesiodistal section of the mandibular second bicuspid and first molar. Chewing force of 25Kg that was devided in the ratio of 45/155 (29%) in bicuspid and 55/155 (35.5%) in molars was applied to telescope denture and abutment teeth respectively. The displacement of the telescope denture base and abutment teeth and the stress distribution in the periodontal ligament and alveolar bone were analized to investigate the influence of chewing force acting on the telescope denture and abutment teeth. The results were as follows: 1. Abutment teeth displaced mesially and the magnitude of displacement of abutment teeth in vertical direction were more than that of horizontal direction in two cases. The displacement of abutment teeth on the telescope denture treated with tapering type telescope crown were less than that of the parallel type crown. 2. The displacement of the telescope denture base that were treated with parallel type telescope crown were less than that of treated with tapering type telescope crown. 3. The stress induced in the alveolar bone and periodontal ligament on abutment teeth that treated with parallel type telescope crown were more than that of treated with tapering type telescope crown and more stress induced in the alveolar bone than in the periodontal ligament. 4. In the telescope denture, the magnitude of displacement of abutment teeth and stress induced in the periodontal ligament and alveolar bone were within physiologic limit.

  • PDF

Implementation of Strain Imaging Modality in Medical Ultrasonic Imaging System (초음파 의료 영상 시스템에서 탄성 영상의 구현)

  • Yoon Ra-Young;Kwon Sung-Jae;Bae Moo-Ho;Jeong Mok-Kun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.3 s.303
    • /
    • pp.53-62
    • /
    • 2005
  • This paper proposes a method of measuring and visualizing the elasticity distribution of the human soft tissue to detect tumors or cancers which have been difficult to diagnose in conventional medical ultrasonic B-mode images. To measure the stiffness of soft tissue, first, pressure is applied to deform the tissue being imaged, and then the amount of mechanical displacement is determined from correlation coefficients obtained from ultrasonic data downconverted into the baseband. We confirmed the feasibility of imaging tissue stiffness by computer simulation and experiment.