The Usefulness of 4D Echocardiographic Modality for Assessing RV Affection in Uncontrolled Hypertensive Patients
-
- Journal of Cardiovascular Imaging
- /
- 제30권4호
- /
- pp.279-289
- /
- 2022
BACKGROUND: In many cardiovascular disorders, the contractile performance of the right ventricle (RV) is the primary determinant of prognosis. For evaluating RV volumes and function, 4 dimensional (4D)-echocardiography has become common. This research used 2D and 4D modalities to assess RV contractile performance in hypertensive patients. METHODS: A total of 150 patients with essential hypertension were enrolled in this study, along with 75 age and sex-matched volunteers. Clinical evaluation and echocardiographic examination (including M-mode, tissue Doppler imaging, and 2D speckle tracking) were conducted on all participants. RV volumes, 4D-ejection fraction (EF), 4D-fractional area change (FAC), 4D-tricuspid annular plane systolic excursion (TAPSE), 4D-septal and free wall (FW) strain were all measured using 4D-echocardiography. RESULTS: Hypertensive patients showed 2D-RV systolic and diastolic dysfunction (including TAPSE, 2D-right ventricular global longitudinal strain, RV-myocardial performance index and average E/EaRV) and 4D-RV impairment (including right ventricular EF, FAC, RV strain and TAPSE, right ventricular end-diastolic volume and right ventricular end-systolic volume) compared to the control group. We verified the prevalence of RV systolic dysfunction in hypertension patients using the following parameters: 1) 15% of them had 2D-TAPSE < 17 mm vs. 40% by 4D-TAPSE; 2) 25% of them had 2D-GLS < 19% vs. 42% by 4D-septal strain and 35% by 4D FW strain; 3) 35% of hypertensive patients had 4D-EF < 45%; and finally; 4) 25% of hypertensive patients had 2D-FAC < 35% compared to 45% by 4D-FAC. CONCLUSIONS: The incidence of RV involvement was greater in 4D than in 2D-modality trans-thoracic echocardiography. We speculated that 4D-echocardiography with 4D-strain imaging would be more beneficial for examining RV morphology and function in hypertensive patients than 2D-echocardiography, since 4D-echocardiography could estimate RV volumes and function without making geometric assumptions.
Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.
Background/Aims: Left ventricular diastolic dysfunction (LVDD) is an early manifestation of cardiac dysfunction in patients with liver cirrhosis (LC). However, the effect of LVDD on survival has not been clarified, especially in decompensated LC. Methods: We prospectively enrolled 70 patients with decompensated LC, including ascites or variceal bleeding, at Daejeon St. Mary's Hospital from April 2013 to April 2015. The cardiac function of these patients was evaluated using 2D echocardiography with tissue Doppler imaging. The diagnosis of LVDD was based on the American Society of Echocardiography guidelines. The primary endpoint was overall survival. Results: Forty-four patients (62.9%) had LVDD. During follow-up (22.3 months), 18 patients died (16 with LVDD and 2 without LVDD). The survival rate was significantly lower in patients with LVDD than in those without LVDD (31.1 months vs. 42.6 months, P=0.01). In a multivariate analysis, the Child-Pugh score and LVDD were independent predictors of survival. Moreover, patients with a ratio of early filling velocity to early diastolic mitral annular velocity (E/e')
목 적 : 아디포넥틴은 혈관벽의 염증 반응을 억제시켜 혈관의 remodeling을 조절하는 내인적 조절 인자이다. 그러나 가와사키병에서 아디포넥틴의 역할은 알려져 있지 않다. 이 연구의 목적은 혈중 아디포넥틴 농도와 IL-6,
Purpose: Severe aplastic anemia (SAA), a fatal disease, requires multiple transfusion, immunosuppressive therapy, and finally, hematopoietic stem cell transplantation (HSCT) as the definitive treatment. We hypothesized that iron overloading associated with multiple transfusions and HSCT-related complications may adversely affect cardiac function. Left ventricular (LV) function was assessed in children after HSCT for SAA. Methods: Forty-six consecutive patients with a median age of 9.8 years (range, 1.5-18 years), who received HSCT for SAA and who underwent comprehensive echocardiography before and after HSCT, were included in this study. The data of LV functional parameters obtained using conventional echocardiography, tissue Doppler imaging (TDI), and speckle-tracking echocardiography (STE) were collected from pre- and post-HSCT echocardiography. These data were compared to those of 40 age-matched normal controls. Results: In patients, the LV ejection fraction, shortening fraction, end-diastolic dimension, mitral early diastolic E velocity, TDI mitral septal E' velocity, and STE LV longitudinal systolic strain rate (SSR) decreased significantly after HSCT. Compared to normal controls, patients had significantly lower post-HSCT early diastolic E velocity and E/A ratio. On STE, patients had significantly decreased LV deformational parameters including LV longitudinal systolic strain (SS), SSR, and diastolic SR (DSR), and circumferential SS and DSR. Serum ferritin levels showed weak but significant correlations (P<0.05) with LV longitudinal SS and SSR and circumferential SS and DSR. Conclusion: Subclinical LV dysfunction is evident in patients after HSCT for SAA, and was associated with increased iron load. Serial monitoring of cardiac function is mandatory in this population.
BACKGROUND: In patients with acute heart failure (AHF), diastolic dysfunction, especially pseudonormal (PN) or restrictive filling pattern (RFP) of left ventricle (LV), is considered to be implicated in a poor prognosis. However, prognostic significance of diastolic dysfunction in patients with ischemic heart disease (IHD) has been rarely investigated in Korea. METHODS: We enrolled 138 patients with IHD presenting as AHF and sinus rhythm during echocardiographic study. Diastolic dysfunction of LV was graded as
BACKGROUND: The prognostic utility of follow-up transthoracic echocardiography (FU-TTE) in patients with hypertrophic cardiomyopathy (HCM) is unclear, specifically in terms of whether changes in echocardiographic parameters in routine FU-TTE parameters are associated with cardiovascular outcomes. METHODS: From 2010 to 2017, 162 patients with HCM were retrospectively enrolled in this study. Using echocardiography, HCM was diagnosed based on morphological criteria. Patients with other diseases that cause cardiac hypertrophy were excluded. TTE parameters at baseline and FU were analyzed. FU-TTE was designated as the last recorded value in patients who did not develop any cardiovascular event or the latest exam before event development. Clinical outcomes were acute heart failure, cardiac death, arrhythmia, ischemic stroke, and cardiogenic syncope. RESULTS: Median interval between the baseline TTE and FU-TTE was 3.3 years. Median clinical FU duration was 4.7 years. Septal trans-mitral velocity/mitral annular tissue Doppler velocity (E/e'), tricuspid regurgitation velocity, left ventricular ejection fraction (LVEF), and left atrial volume index (LAVI) at baseline were recorded. LVEF, LAVI, and E/e' values were associated with poor outcomes. However, no delta values predicted HCM-related cardiovascular outcomes. Logistic regression models incorporating changes in TTE parameters had no significant findings. Baseline LAVI was the best predictor of a poor prognosis. In survival analysis, an already enlarged or increased size LAVI was associated with poorer clinical outcomes. CONCLUSIONS: Changes in echocardiographic parameters extracted from TTE did not assist in predicting clinical outcomes. Cross-sectionally evaluated TTE parameters were superior to changes in TTE parameters between baseline and FU at predicting cardiovascular events.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70