• Title/Summary/Keyword: Tip60

Search Result 249, Processing Time 0.02 seconds

Studies on Fracture Criterion in Yellow Lauan(Shorea spp.) under Mode I, Mode II and Mixed Mode Loading (황(黃)라왕재(Shorea spp.)의 모드 I, 모드 II 및 혼합(混合)모드 하중시(荷重時) 파괴기준(破壞基準)에 관(關)한 연구(硏究))

  • Shim, Kug-Bo;Lee, Jun-Jae;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.61-72
    • /
    • 1992
  • This study was carried out to investigate the fracture behavior and the fracture criterion of yellow lauan(Shorea spp.), when has used for furniture and wood structures, and to offer a reliability for wood structure and basic data for wood fracture criterion in experiments which are fracture tested under mode I, mode II and mixed mode loading condition. The results were summarized as follows; 1. Fractures in specimens which have inclined grain in yellow lauan procedeed from crack tip in the radial direction along the grain. 2. In yellow lauan, $K_{IC}RL$ was 42.1kg/$cm^{3/2}$ and $K_{IIC}RL$ was 15.8kg/$cm^{3/2}$. 3. The fracture criteria of lauan were; ($K_I/K_{IC}$)+($K_{II}/K_{IIC}$)=1 in RL system with inclined grain at $45^{\circ}$, ($K_I/K_{IC}$)+$(K_{II}/K_{IIC})^2$=1 with inclined grain at $15^{\circ}$ and $(K_I/K_{IC})^2$+$(K_{II}/K_{IIC})^2$=1 with inclined grain at $30^{\circ}$, $60^{\circ}$, $75^{\circ}$ and $90^{\circ}$, respectively. 4. The fracture criterion of wood could vary with the species, and the load applying condition. In order to measure the fracture criterion strictly, along with standardization of specimen geometry a large amount of experimental data is needed. 5. $K_{IC}$(critical stress intensity factor) can be predicted by grain angle. As the grain inclined angle increased, $K_{IC}$ and $K_{IIC}$ are increased.

  • PDF

Comparison of Spray Angles of Multihole Port Fuel Gasoline Injector with Different Measuring Methods (측정방법에 따른 흡기포트 분사식 다공 가솔린인젝터의 분무각 비교)

  • Kim, J.H.;Rhim, J.H.;No, S.Y.;Moon, B.S.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.17-26
    • /
    • 2000
  • The main parameter commonly used to evaluate spray distribution is spray angle. Spray angle is important because it influences the axial and radial distribution of the fuel. Spray angles were measured and compared for the two non-air assisted injectors such as 2hole-2stream 4hole-1stream injectors used for port fuel injection gasoline engines with n-heptane as a fuel by three different measuring techniques, i.e., digital image processing, shadowgraphy, and spray patternator, respectively. Fuel was injected with the injection pressures of 0.2-0.35 MPa into the room temperature and atmospheric pressure environment. In digital image processing approach, the selection of the transmittance level is critical to obtain the edge of spray and hence to measure the spray angle. From the measurement results by the shadowgraphy technique, it is dear that the spray angle is varied during the spray injection period. The measurement results from spray patternator show that the different spray angles exist in different region. Spray angle increases with the increase in the injection pressure. it is suggested that the spray angle and stream separated angle should be specified when spray is characterized for 2hole-2stream injector, because spray angle is much different though stream separated angle is same. It was also considerably affected by the measurement techniques introduced in this experimental work. However, the optimal axial distance for measuring the spray angle seems to be at least 60-80 mm from the injector tip for two non-air assisted injectors.

  • PDF

A Case of Pleural Effusion after Malposition of Central Venous Catheter (중심정맥카테터 삽입의 이상위치로 발생한 편측성 흉수 1례)

  • Kim, Jae Seok;Kim, Sang-Ha;Lee, Nak Won;Kwon, Woo Cheol;Choi, Hun;Beon, Jong Won;Hong, Tae Won;Shin, Kye Chul;Yong, Suk Joong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.690-693
    • /
    • 2006
  • Central venous catheterization is used to provide a large amount of fluid, total parenteral nutrition and to administer antitumor agents with few complications reported. We report an uncommon case of pleural effusion that occurred after central venous catheterization. In many cases, the mechanism for the pleural effusion after central venous catheterization occurs through an injury to the superior vena cava by the continuous mechanical force of the catheter tip, the flow of large amount of fluid and an osmotic injury to the wall of the vein. This case is somewhat different in that the central catheter was placed in an aberrant vessel resulting in the pleural effusion. A post-placement chest roentgenogram and the correct approach of catheterization are important for preventing this complication.

Fabrication and characterization of silicon field emitter array with double gate dielectric (이중 게이트 절연막을 가지는 실리콘 전계방출 어레이 제작 및 특성)

  • 이진호;강성원;송윤호;박종문;조경의;이상윤;유형준
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.103-108
    • /
    • 1997
  • Silicon field emitter arrays (FEAs) have been fabricated by a novel method employing a two-step tip etch and a spin-on-glass (SOG) etch-back process using double layered thermal/tetraethylortho-silicate (TEOS) oxides as a gate dielectric. A partial etching was performed by coating a low viscous photo resist and $O_2$ plasma ashing on order to form the double layered gate dielectric. A small gate aperture with low gate leakage current was obtained by the novel process. The hight and the end radius of the fabricated emitter was about 1.1 $\mu\textrm{m}$ and less than 100$\AA$, respectively. The anode emission current from a 256 tips array was turned-on at a gate voltage of 40 V. Also, the gate current was less than 0.1% of the anode current.

  • PDF

Fatigue Fracture Characteristics by Corrosion Degradation of 12Cr Alloy Steel (12Cr합금강의 부식열화에 의한 피로파괴 특성)

  • Jo, Seon-Yeong;Kim, Cheol-Han;Bae, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.996-1003
    • /
    • 2001
  • In order to investigate the fatigue fracture characteristics by corrosion degradation of 12Cr alloy steel, both the fatigue characteristics in air of them artificially degraded during long period and the corrosion fatigue characteristics were experimentally evaluated in various environments which were determined from electro-chemical polarization tests. And also, their fracture mechanisms were analyzed and compared, fractographyically. From their results, the fracture mechanical characteristics of it artificially degraded during long period in the distilled water, 3.5 wt.% NaCl solution and 12.7wt.%(1M) Na$_2$SO$_4$solution of 25, 60 and 90$\^{C}$ did not show distinguishable difference comparing with non-corroded one in regardless of temperature and degradation period. It means that degradation of the material by just surface corrosion does not remarkably affect to fatigue crack growth. On the other hand, the crack growth rates by corrosion fatigue increased due to activity increase of corrosive factors such as OH(sub)-,Cl(sup)- and SO$_4$(sup)- at the crack tip with temperature increase. Therefore, the crack growth rates by corrosion fatigue were more faster than that in air of the artificially degraded specimen due to the such difference of crack growth mechanism.

Tribological Performance of Ni-Cr Composite Coating Sprayed onto AISI 4340 (SNCM439) Steel by High Velocity Oxygen Fuel

  • Umarov, Rakhmatjon;Pyun, Young-Sik;Amanov, Auezhan
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.217-225
    • /
    • 2018
  • In this study, we spray a Ni-Cr composite powder onto AISI 4340 steel using the high velocity oxygen fuel method. We subsequently subject the Ni-Cr coating (as-sprayed) to ultrasonic nanocrystal surface modification (UNSM) process to improve the tribological performance. This study aims at increasing the wear resistance and durability of the Ni-Cr coating by altering the surface integrity and microstructure via the UNSM process. The UNSM process reduces the surface roughness of the as-sprayed coating by about 64%, which is explained by observing the elimination of high peaks and valleys and filling up micro-pores. Furthermore, a change in the microstructure of the coating due to continuous high-frequency strikes to the surface by a tip can lead to an increase in hardness from about 48 to 60 HRC. Furthermore, we investigate the characterization of the friction and wear behavior of Ni-Cr coating by a ball-on-disc tribometer in the dry conditions. We determine that after the UNSM process, there is a significant reduction in the friction coefficient of the as-sprayed coating from approximately 1.1 to 0.75. This is owing to the increased hardness and smoothed surface roughness. In addition, we investigate the surface morphology and wear track of the coatings before and after the UNSM process using a scanning electron microscope, energy dispersive spectrometer, and three-dimensional laser scanning microscope. We observe that the wear track of the Ni-Cr coating after the UNSM process is lower than that of the as-sprayed one. Thus, we confirm that the UNSM process has a significant influence on the improvement of the tribological performance of the Ni-Cr composite coating.

Cryopreservation of Citrus limon (L.) Burm. F Shoot Tips Using a Droplet-vitrification Method

  • Yi, Jung-Yoon;Balaraju, Kotnala;Baek, Hyung-Jin;Yoon, Mun-Seop;Kim, Haeng-Hoon;Lee, Young-Yi
    • Korean Journal of Plant Resources
    • /
    • v.31 no.6
    • /
    • pp.684-694
    • /
    • 2018
  • This study describes the successful establishment of a cryopreservation protocol for Citrus limon cultivars: 'Frost Eureka limon' and 'Cook Eureka limon', using a droplet-vitrification method. The shoot tips that were excised from in vitro grown seedlings of the two cultivars were preserved in liquid nitrogen (LN) and successfully regenerated into whole plants. Excised shoot tips were pre-cultured for 1 or 2 days in 0.3 M and 0.5 M sucrose solutions at $25^{\circ}C$ and incubated in a loading solution (LS) composed of 17.5% glycerol + 17.5% sucrose in Murashige and Skoog (MS) medium for 40 min at $25^{\circ}C$. Prior to direct immersion in LN for 1 h, the shoot tips were dehydrated with plant vitrification solution 2 (PVS2) at $0^{\circ}C$ or PVS3 at $25^{\circ}C$. The frozen shoot tips were re-warmed and unloaded with 1.2 M sucrose in $\text\tiny{^1/_2}$ MS for 30 min at $25^{\circ}C$. Shoot tips were post-cultured overnight on survival medium and then micrografted onto 'trifoliate orange' (Poncirus trifoliate (L.) Raf. seedling rootstocks for recovery and to produce whole plants. The highest regrowth rates were 53.5% and 50.3% for cryopreserved shoot tips of 'Frost Eureka limon' and 'Cook Eureka limon', respectively, when pre-cultured in 0.3 M and 0.5 M sucrose concentrations in a sequencing manner, with LS and treated with PVS2 for 60 min at $0^{\circ}C$. We also investigated whether the ammonium ion concentration on post-culture medium affected the viability of the cryopreserved Citrus shoot tips. The viability of cooled samples, following culturing on woody plant media (WPM) containing $\text\tiny{^1/_4}$ ammonium nitrate overnight before micrografting, was the highest (70.3%) in 'Frost Eureka limon'. The study described here is a cost-effective and safe method to conserve Citrus fruit cultivars, for the improvement and large-scale multiplication of fruit plants and for breeding disease resistance.

Failure characteristics and mechanical mechanism of study on red sandstone with combined defects

  • Chen, Bing;Xia, Zhiguo;Xu, Yadong;Liu, Shuai;Liu, Xingzong
    • Geomechanics and Engineering
    • /
    • v.24 no.2
    • /
    • pp.179-191
    • /
    • 2021
  • In this study, the strength and failure mechanism of red sandstones with combined defects were investigated by uniaxial compression tests on red sandstones with different crack angles using two-dimensional particle flow code numerical software, and their mechanical parameters and failure process were studied and analyzed. The results showed that the mechanical characteristics such as peak strength, peak strain, and elastic modulus of the samples with prefabricated combined defects were significantly inferior than those of the intact samples. With increasing crack angle from 15° to 60°, the weakening area of cracks increased, elastic modulus, peak strength, and peak strain gradually reduced, the total number of cracks increased, and more strain energy was released. In addition, the samples underwent initial brittle failure to plastic failure stage, and the failure form was more significant, leading to peeling phenomenon. However, with increasing crack angle from 75° to 90°, the crack-hole combination shared the stress concentration at the tip of the crack-crack combination, resulted in a gradual increase in elastic modulus, peak strain and peak strength, but a decrease in the number of total cracks, the release of strain energy reduced, the plastic failure state weakened, and the spalling phenomenon slowed down. On this basis, the samples with 30° and 45° crack-crack combination were selected for further experimental investigation. Through comparative analysis between the experimental and simulation results, the failure strength and final failure mode with cracks propagation of samples were found to be relatively similar.

Practical Application of Cryopreservation of In Vitro Grown Shoot Tips of Strawberry (Fragaria × ananassa Duch.) using Droplet-Vitrification

  • Jinjoo Bae;Young-Yi Lee;Jae-Young Song;Jung-Ro Lee;Munsup Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2021.04a
    • /
    • pp.36-36
    • /
    • 2021
  • Cryopreservation has been broadly used as an efficient method for a long-term conservation for many types of plants especially vegetatively propagated plants. Among several cryopreservation methods, a droplet-vitrification was the most widely applicable and efficient method. Studies have developed protocols for strawberry using droplet-vitrification method and suggested the practical use of the protocol for large number of germplasm with a little modification. In this study, the droplet vitrification method of shoot tip has been tested on 31 accessions provided around the world. Shoot tips were precultured on Murashige and Skoog (MS) liquid medium supplemented with 0.3~0.5M sucrose. Precultured explants were osmoprotected with loading solution, 35% of PVS3 (C4, 17.5% glycerol and 17.5% sucrose) for 40 min and exposed to dehydration solution, PVS3 (B1, 50% glycerol and 50% sucrose) for 60 min. Then, the explants were transferred onto droplets containing 2.5 uL PVS3 on sterilized aluminum foils prior to direct immersion in liquid nitrogen (LN) for 1hr. The cryopreserved shoot tips were rapidly warmed in a water bath at 40C and then unloaded in MS with 0.8M sucrose for 40 min. The shoot tips were cultured in NH4NO3-free MS post culture medium for 2 weeks. Subsequently, the explants were moved to the MS medium for 6 weeks and evaluated the regrowth rate. By this droplet-vitrification protocol, twenty-four accessions showed at least 40% regrowth rate. Out of 24 accessions, 'Nonsan1ho' had the highest regeneration rate of 85.8% and 'Jumbo pureberry' had the lowest with 42.1%.

  • PDF

Percutaneous Thrombin Injection Based on Computational Fluid Dynamics of Femoral Artery Pseudoaneurysms

  • Hyoung-Ho Kim;Kyung-Wuk Kim;Changje Lee;Young Ho Choi;Min Uk Kim;Yasutaka Baba
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1834-1840
    • /
    • 2021
  • Objective: To analyze the computational fluid dynamics (CFD) of femoral artery pseudoaneurysm (FAP), identify a suitable location and timing for percutaneous thrombin injection (PTI) based on this analysis, and report our clinical experience with the procedure. Materials and Methods: CFD can be used to analyze the hemodynamics of the human body. An analysis using CFD recommended that the suitable location of the needle tip for PTI is at the center of the aneurysm sac and the optimal timing for starting PTI is during the early inflow phase of blood into the sac. Since 2011, seven patients (three male and four female; median age, 60 years [range, 43-75 years]) with FAP were treated with PTI based on the devised suitable location and time. Prior to the procedure, color Doppler ultrasonography was performed to determine the location and timing of the thrombin injection. Results: The technical success rate of the PTI was 100%. The amount of thrombin used for the procedure ranged from 200 IU to 1000 IU (median, 500 IU). None of the patients experienced any symptoms or signs of embolic complications during the procedure. Follow-up CT images did not reveal any embolism in the lower extremities and showed complete thrombosis of the pseudoaneurysm. Conclusion: Based on our study of CFD, PTI administered centrally in the FAP during early inflow, as seen on color Doppler, can be an effective technique.