• 제목/요약/키워드: Tip axial length

검색결과 35건 처리시간 0.018초

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

Urea-SCR시스템 액막형 선회분사기의 분사압력변화에 따른 무특성에 관한 연구 (Effect of injection pressure on the atomization characteristics of a liquid sheet-type swirl injector for Urea-SCR system)

  • 김덕진;양동욱;이지근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.510-519
    • /
    • 2013
  • Urea-SCR시스템에 적용하기 위한 액막형 선회분사기의 분사압력변화에 따른 분무특성이 실험적으로 조사되었다. 실험에 사용된 노즐은 형상비 3.1을 갖는 단공 압력식 액막형 선회노즐이며, 노즐선단에 분사되는 유체에 선회류를 형성하기 위한 선회기가 설치되어 있다. 노즐의 분사량 조절은 PWM(pulse width modulation)기법에 의해 제어되었다. 분무의 발달과정은 2차원 PIV에 의해 가시화되었으며, 분무각 변화가 조사되었다. 분무액적의 속도 및 크기는 2차원 PDPA에 의해 상온 대기압 조건에서 측정되었다. 분무구조는 분사압력에 큰 영향을 받으며, SMD는 분사압력 증가에 따라 감소하며 선행연구자의 반실험적 결과와 유사한 경향을 보임을 알 수 있었다.

Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation

  • Kwak, Sang-Won;Ha, Jung-Hong;Lee, WooCheol;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.270-275
    • /
    • 2014
  • Objectives: This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. Materials and Methods: The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files' deflection. The files (n = 10) were fixed at 3 mm from the tip and then bent $45^{\circ}$ with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3 mm, and clockwise rotations (2 rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. Results: The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). Conclusions: The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.

현장시험을 통한 개단말뚝의 폐색효과에 대한 연구 (Analysis of Plugging Effect for Open-ended Piles Based on Field Tests)

  • 고준영;정상섬
    • 한국지반공학회논문집
    • /
    • 제30권12호
    • /
    • pp.51-61
    • /
    • 2014
  • 연구에서는 사질토 지반에서 개단말뚝의 지지력에 영향을 미치는 폐색효과를 조사하기 위하여 현장재하시험을 수행하였다. 현장재하시험은 직경이 다른 총 3본의 시험말뚝(508.0, 711.2, 914.4mm)을 제작하여 각각 동재하시험과 정재하시험을 실시하였다. 내주면마찰력과 외주면마찰력을 분리 측정하기 위하여 시험말뚝을 이중관으로 제작하였고, 외부말뚝의 안쪽과 내부말뚝의 바깥쪽 표면에 변형률계를 부착하였다. 정재하시험 결과, 내주면마찰력은 선단부로부터 총 관내토 길이의 약 18-34%의 부근에서 집중적으로 발생하였고, 이를 통해 말뚝 선단부근의 관내토가 내주면마찰력 발현에 큰 영향을 미치는 것을 알 수 있었다. 또한, 말뚝직경이 클수록 전체지지력에 대한 내주면마찰력과 순단면적의 선단지지력의 합의 비가 감소하는 것으로 나타났다. 그리고 말뚝의 폐색율을 정량화하기 위해 시험말뚝의 incremental filling ratio(IFR)를 측정하여 분석한 결과, SPT의 N값과 상관관계가 있는 것으로 나타났다.

전산화단층촬영법을 이용한 하악 전돌증 환자의 하악지 시상 골절단술후 하악과두 위치변화 분석 (EVALUATION OF CONDYLAR POSITION USING COMPUTED TOMOGRAPH FOLLOWING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY)

  • 최강영;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권4호
    • /
    • pp.570-593
    • /
    • 1996
  • 본교실에서 하악지 시상 골절단술을 시행한 하악전돌증 환자 20명(남자 9명, 여자 11명)을 대상으로 술전, 술직후, 장기관찰기간동안의 전산화단층촬영법을 이용한 하악과두의 위치변화와 술전, 술직후, 악간고정제거 24시간후 및 장기관찰기간동안의 측모두부방사선사진에서의 재발과의 상관관계를 연구한 결과 다음과 같은 결과를 얻었다. 1. 두부 축방향 전산화단층사진에서의 과두간거리(MM')는 $84.45{\pm}4.01mm$ 였으며, 장축각은 우측 11.89%5.1 $9^{\circ}$좌측 $11.65{\pm}2.09^{\circ}$로 좌우 비슷하였으며, 기준선(AA')에서 과두의 외측점은 12mm, 내측점은 7mm 정도 전방에 위치하였다. 관상면 전산화단층사진에서의 과두간 거리(mm')는 $84.43{\pm}3.96mm$ 였으며, 사축각은 우측 $78.12{\pm}3.43^{\circ}$ 좌측 $78.09{\pm}6.12^{\circ}$로 좌우 비슷하였다 . 2. 술전후 과두위치 변화(T2C-T1C)는 통계적인 유의성은 없었으나(p>0.05), 다소 증가하는 경향을 보였으며, 장기관찰에 따른 회귀성향(TLC-T2C)에서는 LMD, LLD(p<0.05), RLD, RMD(p<0.01), mm'(P<0.001)는 모두 감소하였다. 3. 측면두부방사선사진상에서 술직후와 악간고정제거 24시간후(T3-T2)에서 하악의 초기재발은 통계적인 의의가 없었으며(p>0.05) 하악전치의 경우만 평균 0.33mm 전방이동하였다(p<0.05). NN'L1, NN'Pog, NN'Gn, NN'Me, over-jet에서 통계적인 유의성이 있었으며(p<0.05), NN'Ll 1.2%, NN'B 5.0%, NN'Pog 2.0%, NN'Gn 9.1%, NN'Me 10.3%의 총재발량을 보였다. 4. 하악골의 술전, 술후 변화량(T2-T1)이 총재발량에 미치는 영향에 대한 회귀분석에서 후퇴량이 많을수록 하악골의 총재발량이 많은 것으로 나타났다(p<0.05). 5. 하악골 변화량(T2-T1)과 하악과두 변화량(T2C-T1C, TLC-T2C), 하악과두 변화량(T2C-T1C, TLC-T2C)과 총재발량(TL-T2), 술전 하악과두 형태(T1C)와 하악과두 변화량(T2C-T1C, TLC-T2C), 그리고 술전 하악골 외형(T1)과 하악과두 변화량(T2C-T1C, TLC-T2C)에 대하여 단순 및 복잡회귀분석에서 통계적인 유의성은 없었다(p>0.05). 6. 술전 하악과두 형태(T1C)가 총재발량(TL-T2)에 미치는 영향에 대한 복잡회귀분석결과 우측과두에서는 과두간 거리가 멀고 장축각이 적고 사축각이 클수록 하악골의 수평적인 재발(NN'Ll, NN'8, NN'Pog, NN'Gn, NN'Me)이 많은 것으로 나타났으며(p<0.05), 좌측과두에서는 NN'Ll, NN'Me에서 같은 결과를 보였다. 7, 술전 하악과두 형태(T1C)가 술전 하악골외형(T1)에 미치는 영향에 대한 복잡회귀분석결과 우측과두에서는 과두간 거리가 멀고 장축각이 적고 사축각이 클수록 하악골의 수직고경이 큰 것으로 나타났고(p<0.05), 좌측과두에서는 과두간 거리가 멀고 장축각이 적고 사축각이 클수록 수직고경이 크며, 전돌된 양상으로 나타났다(p<0.05) . 8. 술전 하악골 외형(T1)이 총 재발량(TL-T2)에 미치는 영향에 대하여 단순회귀분석을 시행한 결과 NN'L1, NN'B, NN'Gn, NN'Me, over-jet 둥의 계측점에서 하악골이 전돌된 양상을 보일수록 NN'B에서의 총재발량은 많은 것으로 나타났다(p<0.05). 또 수평피개량(over-jet)이 클수록 NN'B, NN'Pog, NN'Gn, NN'Me에서의 총재발량이 많은 것으로 나타났다(p<0.05). 따라서 과두보존술을 이용하여 과두를 안정화시키고 난후 악골 형태를 재구성하였을 때 이로 인하여 생기는 하악과두 이동은 미미하여 술후 재발에 크게 영향을 미칠 정도는 아니라고 사료된다.

  • PDF