• Title/Summary/Keyword: Tip angle

검색결과 601건 처리시간 0.025초

직접분사식 가솔린 선회분사기 개발에 관한 연구 III (Development of Gasoline Direct Swirl Injector III)

  • 박용국;오재건;이충원
    • 한국분무공학회지
    • /
    • 제6권4호
    • /
    • pp.39-48
    • /
    • 2001
  • The Gasoline Direct Injection(GDI) system has been highlighted due to the improvement of fuel consumption and the control of exhaust emission from gasoline engines. Main purpose of the present study is to measure spray characteristics of GDSI for real engine application. We have investigated experimentally spray tip penetration, spray angle, tip velocity and spatial spray distribution. Counter-rotating vortex grown on the spray surface plays an important role in the spray characteristics. Accordingly the spray tip penetration and tip velocity do not excess 50mm, 20m/s respectively, under 0.6MPa ambient pressure. the spray cone angle of GDSI have a same tendency to a simplex swirl atomizer.

  • PDF

일반 구조용강 열간압연 박판에 대한 CTOD와 CTOA 곡선 결정 (Determination of CTOD & CTOA Curve for Structural Steel Hot-Rolled Thin Plates)

  • 이계승;이억섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.729-732
    • /
    • 2003
  • The K-R design curve is an engineering method of linear-elastic fracture analysis under plane-stress loading conditions. By the way, linear-elastic fracture mechanics (LEFM) is valid only as long as nonlinear material deformation is confined to a small region surrounding the crack tip. Like general steels, it is virtually impossible to characterize the fracture behavior with LEFM, in many materials. Critical values of J contour integral or crack tip opening displacement (CTOD) give nearly size independent measures of fracture toughness, even for relatively large amounts of crack tip plasticity. Furthermore, the crack tip opening displacement is the only parameter that can be directly measured in the fracture test. On the other. the crack tip opening angle (CTOA) test is similar to CTOD experimentally. Moreover, the test is easier to measure the fracture toughness than other method. The shape of the CTOA curve depends on material fracture behavior and, on the opening configuration of the cracked structure. CTOA parameter describes crack tip conditions in elastic-plastic materials, and it can be used as a fracture criterion effectively. In this paper, CTOA test is performed for steel JS-SS400 hot-rolled thin plates under plane-stress loading conditions. Special experimental apparatuses are used to prevent specimens from buckling and to measure crack tip opening angle for thin compact tension (CT) specimens.

  • PDF

Stripe 코팅용 슬롯 다이 헤드 모세관 유동 전산모사 (Simulation of Capillary Flow Along a Slot-die Head for Stripe Coatings)

  • 유수호;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.92-96
    • /
    • 2019
  • In the presence of ${\mu}-tip$ embedded in a slot-die head for stripe coatings, there arises the capillary flow that limits an increase of the stripe density, which is required for the potential applications in organic light-emitting diode displays. With an attempt to suppress it, we have employed a computational fluid dynamics software and performed simulations by varying the ${\mu}-tip$ length and the contact angles of the head lip and ${\mu}-tip$. We have first demonstrated that such a capillary flow phenomenon (a spread of solution along the head lip) observed experimentally can be reproduced by the computational fluid dynamics software. Through simulations, we have found that stronger capillary flow is observed in the hydrophilic head lip with a smaller contact angle and it is suppressed effectively as the contact angle increases. When the contact angle of the head lip increases from $16^{\circ}$ to $130^{\circ}$, the distance a solution can reach decreases sharply from $256{\mu}m$ to $44{\mu}m$. With increasing contact angle of the ${\mu}-tip$, however, the solution flow along the ${\mu}-tip$ is disturbed and thus the capillary flow phenomenon becomes more severe. If the ${\mu}-tip$ is long, the capillary flow also appears strong due to an increase of flow resistance (electronic-hydraulic analogy). It can be suppressed by reducing the ${\mu}-tip$ length, but not as effectively as reducing the contact angle of the head lip.

바이오 디젤 연료의 고압 분무 특성 (Characteristics of High Pressure Bio-diesel Fuel Spray)

  • 홍창호;최욱;최병철;이기영
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.56-62
    • /
    • 2003
  • Spray characteristics of conventional diesel fuel and bio-diesel fuel(methyl-ester of soybean oil) were compared, in terms of spray tip penetration and spray angle, by using a commercial high pressure common rail injection system for light-duty DI Diesel engines. The experiments were carried out under the non-evaporating condition at ambient density(8.8, $15.6 kg/\textrm{m}^3$) and injection pressure(75, 135 MPa). The experimental method was based on a laser sheet scattering technique. Spray tip penetrations of bio-diesel fuel were longer, on the whole, than those of conventional diesel fuel, except for lower injection pressure(75 MPa) under lower ambient density$(8.8 kg/\textrm{m}^3)$. But spray near angle and spray far angle of bio-diesel fuel were smaller than those of conventional diesel fuel, implying spray angle is related to the growth rate of spray tip penetration. The experimental results of spray tip penetration agreed well with the calculated values by the Wakuri et al.'s correlation based on the momentum theory.

분무특성에 미치는 압력.온도의 영향 (An Effect of Pressure and Temperature on Spray Characteristic)

  • 오은탁;류호성;안병규;송규근;정재연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.946-951
    • /
    • 2001
  • This experimental study is to investigate the intermittent spray characteristics of a pintle nozzle. High speed camera used in this expreiment with 9000fps. The factor, which controls the diesel spray, is the Injection pressure, ambient pressure and ambient temperature. In this paper, experiments were conducted free spray for the ambient pressure(3, 4, 5Mpa), nozzle Injection pressure(10, 14, 18MPa) and ambient temperature(293, 473K). With the higher opening pressure, the spray tip velocity and spray penetration increases while the spray angle decreases, On the other hand, With the higher ambient pressure, the spray angle increase while the spray tip penetration and spray tip velocity decrease. also, With the higher ambient temperature, the spray penetration decrease while the spray angle decrease.

  • PDF

균열가지 효과를 고려한 균열 성장 지연 거동 예측 (변동하중하에서의 피로거동) (The Prediction of Crack Growth Retardation Behavior by Crack Tip Branching Effects (Fatigue Behavior in variable Loading Condition))

  • 권윤기
    • 한국생산제조학회지
    • /
    • 제8권2호
    • /
    • pp.126-136
    • /
    • 1999
  • We studied on crack growth retardation in single overloading condition. Crack tip branching which as the second mechanism on crack growth retardation was examined. Crack tip branching was observed to kinked type and forked type. It was found that the branching angle range was from 25 to 53 degree. The variations of crack driving force with branching angle were calculated with finite element method The variation of {{{{ KAPPA _I}}}}, {{{{ KAPPA _II}}}} and total crack driving force(K) were examined respectively So {{{{ KAPPA _I}}}}, {{{{ KAPPA _II}}}} and K mean to mode I, II and total crack driving force. Present model(Willenborg's model) for crack growth retardation prediction was modified to take into consideration the effects of crack tip branching When we predicted retardation with modified model. it was confirmed that predicted and experimental results coincided with well each other.

  • PDF

2축 스크류 니더의 설계에서 스크류 로터 팁의 각도가 믹싱성능에 미치는 영향 (Influence of Screw Rotors Tip Angle on Mixing Performance for One Novel Twin-screw Kneader)

  • Wei, Jing;Chen, Dabing;Zhou, Dongming;Zhang, Aiqiang;Yang, Yuliang
    • 폴리머
    • /
    • 제39권3호
    • /
    • pp.441-452
    • /
    • 2015
  • Twin-screw kneader is an efficient polymer processing equipment. In this paper, the mixing performance of one novel intermeshing counter-rotating twin-screw kneader with different tip angles of the male rotor is simulated using the mesh superimposition technique (MST). Statistical analysis is carried out for the flow field using particle tracking technique, and distributive mixing performance is evaluated using the residence time distribution and segregation scale, while the dispersive mixing performance is estimated using the parameters such as shear rate, stretching rate and mixing index. The results show that the best distributive mixing performance is achieved when the tip angle is 0o, while the optimal dispersive mixing performance is obtained when the tip angle is 20o. The results in this paper provide a data basis for the selection of parameters and optimization of the performance for the screw rotors.

벽면에 충돌하는 가솔린 분무의 특성에 관한 연구 (A study on the characteristics of gasoline spray to impinge on wall)

  • 이규영
    • 한국분무공학회지
    • /
    • 제10권1호
    • /
    • pp.17-23
    • /
    • 2005
  • Even though a relatively complete knowledge base has been established for diesel sprays, much of the knowledge cannot be directly translated to correlate the characteristics of gasoline spray. The macroscopic characteristics of gasoline impingement spray was investigated with photographic and image processing technique by Particle Motion Analysis System. The injector with single hole nozzle diameter of 0.28 mm was used in this experiment and the injection duration was selected as 10 msec. The injection pressure with 0.3, 0.35, and 0.4 MPa, impingement distance or 70, 100 and 130m, impingement angle or 0.15, 30 and $45^{\circ}$ were employed for the variables to affect the spray characteristics of impinging spray. It is clear that there is the analogy on the spray tip penetration between the gasoline impinging jet and diesel free jet. The spray tip penetration of impinging gasoline spray is proportional to the quarter power of the time after start of injection. The maximum height of impinging gasoline spray is also proportional to the quarter power of the time regardless of impingement distance, impingement angle and injection pressure. In addition, the effect of impingement angle on the spray tip penetration is significant according to the time after start of injection, even though there is minor effect in the initial stage of time after start of injection. Moreover, there is no remarkable effect of injection pressure on the spray tip Penetration under the experimental condition used in this study.

  • PDF

DME 연료의 거시적 분무특성에 관한 실험적 연구 (Experimental Study on the Macroscopic Spray Characteristics of DME Fuel)

  • 박정환;박수한;이창식;박성욱
    • 한국분무공학회지
    • /
    • 제15권3호
    • /
    • pp.115-123
    • /
    • 2010
  • The purpose of this study is to compare and to investigate spray characteristics of dimethyl ether (DME) and diesel fuel in the various injection pressures, ambient pressures, and the energizing durations. For the analysis of the spray characteristics, the spray visualization system including the high speed camera and the spray image analyzer is installed. The spray characteristics such as the spray development process, spray tip penetraion and the spray cone angle are analyzed from the spray images. It was revealed that the spray characteristics of DME and diesel fuels are mainly affected by the injection conditions. However, in the region after the end of the injection, the spray tip penetration was affected by the fuel properties such as the fuel density, the surface tension, and the viscosity. DME fuel has generally a short tip penetration and a wide cone angle. In the elevating conditions of the ambient gas pressure, the spray cone angle of DME fuel converged to high value when comparing diesel fuel in advance. Also, the increasing rate of the spray tip penetration in DME fuel is significantly decreased from 0.7 ms of the energizing duration (diesel : 0.9 ms).

하치조신경 마취시 하악공으로의 접근을 위한 전산화단층촬영을 통한 방사선적 연구 (THE STUDY BY USING THE COMPUTERIZED TOMOGRAPHY IMAGING IN ORDER TO ACCESS TO MANDIBULAR FORAMEN WHILE INFERIOR ALVEOLAR NERVE ANESTHESIA)

  • 김지광;구홍;안진석;국민석;박홍주;오희균;조진형
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권6호
    • /
    • pp.566-574
    • /
    • 2006
  • Purpose : This study was performed to provide an anatomical information of the mandibular ramus for the successful inferior alveolar nerve block. Three dimensional images were reconstructed from the computerized tomography (CT) and the anatomical evaluation of the mandibular ramus was done. Materials and methods : Sixty-four patients who had been taken the facial CT scans from 2000, Jan to 2003, June was selected. The patients who had the anterior or posterior teeth misssing, edentulous ridge, and jaw fracture were excepted. In the occulusal plane, the lingual surface angle (LSA) between the mid-sagittal plane and the mandibular molar lingual surface from the 2nd premolar to the 2nd molar, the inner ramal surface angle (IRSA), the maximum inner ramal surface angle (MxIRSA), and the outer ramal surface angle (ORSA) to the-mid sagittal plane were measured. The inner ramal surface angle in the ligular tip level (IRSA-L) and the outer ramal surface angle in the ligular tip level (ORSA-L), the ramal length (RL), and the anterior ramal length (ARL) were also measured in the lingular tip level. Results : In the lingular tip level, the mean IRSA-L and ORSA-L were $28.6{\pm}6.3^{\circ}$ and $17.9{\pm}4.9^{\circ}$ respectively. The larger was the IRSA, the larger was the ORSA. In the lingular tip level, the mean ramal length was 35.8${\pm}$3.4 mm. The larger was the IRSA-L, the shorter was the ramal length. On the lingular tip level, the mean anterior ramal length from anterior ramus to lingular tip was 19.6${\pm}$3.3 mm. when the ramal length was longer, the anterior ramal length was also longer. On the lingular tip level, there was positive correlation vetween the IRSA and the ORSA, negative correlation between the IRSA and the ramal length, and positive correlation between the ramal length and the lingular tip level to the anterior ramus. There was no statistical meaning of data between sex and age. Conclusion : In the clinical view of the results so far achieved, if the direction of needle is closer to posterior it is able to contact bone on lingular tip when the internal surface of ramus is wided outer.