• Title/Summary/Keyword: Tip

Search Result 5,514, Processing Time 0.04 seconds

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

The Continuous Monitoring of Oxygen Saturation During Fiberoptic Bronchoscopy (기관지내시경 검사시 지속적인 동맥혈 산소포화도 감시의 필요성)

  • Kang, Hyun Jae;Kim, Yeon Jae;Chyun, Jae Hyun;Do, Yun Kyung;Lee, Byung Ki;Kim, Won Ho;Park, Jae Yong;Jung, Tae Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.385-394
    • /
    • 2002
  • Background : Flexible fiberoptic bronchoscopy(FFB) has become a widely performed technique for diagnosing and managing pulmonary disease because of its low complication and mortality rate. Since the use of FFB can in patients with severely depressed cardiorespiratory function is increasing and hypoxemia during the FFB can induce significant cardiac arrhythmias, the early detection and adequate management of hypoxemia during FFB is clinically important. Method : To evaluate the necessity of the continuous monitoring of the oxygen saturation($SaO_2$) during the FFB, the $SaO_2$ was continuously monitored from the finger tip using pulse oximetry before, during and after the FFB in 379 patient. The patients were then divided into two groups, those with and without hypoxemia($SaO_2$<90%). The baseline pulmonary function data and the clinical characteristics of the two groups were compared. Results : The mean baseline $SaO_2$ was $96.9{\pm}2.85%$. An $SaO_2$ <90% was recorded at some point in 62(16.4%) out of 379 patients, with 12 out of 62 experiencing this prior to the FFB, in 37 out of 62 during the FFB, and in 13 out of 62 after the FFB. No differences were observed in the smoking and sex distribution between those with and without hypoxemia. The mean age was older in those with hypoxemia than in those without. Significant differences were observed in the mean baseline $SaO_2$ and the mean time for the procedure between the two groups. The $FEV_1$ was significantly lower in those with hypoxemia, and both the FVC and $FEV_1/FVC$ also tended to decrease in this group. Managing hypoxemia included deep breathing in 20 patients, a supplemental oxygen supply in 39 patients, and the abortion of the procedure in 3 patients. Conclusion : These results suggest that the continuous monitoring of the oxygen saturation is necessary during fiberoptic bronchoscopy, and it should be performed in patients with a depressed pulmonay function in order for the early detection and adequate management of hypoxemia.

Studies on Biology and Control of the Mulberry Small Weevil, Baris deplanata ROELOFS (Coleoptera: Curculionidae) (뽕나무애바구미의 생태 및 방제에 관한 연구)

  • 백현준;백운하
    • Journal of Sericultural and Entomological Science
    • /
    • v.18 no.2
    • /
    • pp.65-78
    • /
    • 1976
  • The mulberry small weevil, Baris deplanata ROELOFS, has highly infested mulberry trees in Korea. As the damage caused by the mulberry small weevil in mulberry fields has been increased over the country since 1969, the authors has carried out a series of biological and controlling studies on the pest from 1971 to 1972. The results obtained are summarized as follows. 1. The adult weevil is elongate oval in shape with black in color and the probocis is long as usual in curculionidae. The size of adult female is 3.30${\pm}$0.04mm in length, 1.47${\pm}$0.04mm in width, and the length of proboscis is 1.25${\pm}$0.014mm, while adult male is 3.28${\pm}$0.06mm in length, 1.40${\pm}$0.04mm in width, and the length of proboscis is 1.30${\pm}$0.02mm. The antenna is geniculate consisting of 12 segments. The terminal sternite of the abdomen has a pointed tip in male but not in female. 2. The egg is long oval in shape, milky white in color, 0.51${\pm}$0.05mm in length and 0.32${\pm}$0.02mm in width. 3. The mature larva is cylindrical and light yellowow in color except the head of dark brown, and legless, 3.88${\pm}$0.06mm in length, 1.40${\pm}$0.02mm width, each segment bearing many wrinkless and short setae. 4. The pupa is long oval, milky white and exarate, 3.53${\pm}$0.09 in length, 1.40${\pm}$0.03mm in width. 5. Majority of the species has one generation through a year and overwinters as adult in xylem of withered branch and come out again from late April to early May in next year. But some of the female oviposit in the same year and the offsprings overwinter as larva (0.4%) or pupa (0.1%) 6. The eggs are mostly laid under the cork layer of withered branch and the number of eggs deposited by an adult female is 73.44${\pm}$8.74, the average egg-laying period is 33.88${\pm}$6.04 days. The incubation period is 11.69${\pm}$0.39 days, the larval period 45.04${\pm}$1.63 and the pupal period 11.05${\pm}$0.49 days. The period of adult's activity is 46.7${\pm}$5.90 days. 7. The larvae feed on the cambium under the bark and adults feed on the winter bud, the latent bud, the leaf stalk and the base of newly shoot. 8. An active period of adults was observed during the period of 4 months from April to July. However, the peak of adult-density occurred in the early May (in the fields of spring-prunning) and early to middle June(in the fields of summer-prunning). 9. There is a positive correlation between the density of larvae and diameter and length of the branches. 10. The pattern of distributions of the adult of mulberry small weevil is negative binomial distribution. 11. The chalcid fly was disclosed to be a natural enemy which was parasite on the larvae of mulberry small weevil and its parasitic ratio was 11.9%. 12. Phosvel D, Malix D, Salithion EC, DDVP EC, and Phosvel EC were effective for the control of adults and Satchukoto-S EC, and Salithio EC were effective for the control of larvae.

  • PDF

A Clinical Evaluation of Splanchnic Nerve Block (내장신경차단에 관한 임상적 연구)

  • Kim, Soo-Yeoun;Oh, Hung-Kun;Yoon, Duek-Mi;Shin, Yang-Sik;Lee, Youn-Woo;Kim, Jong-Rae
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.34-46
    • /
    • 1988
  • Intractable pain from advanced carcinoma of the upper abdomen is difficult to manage. One method used to control pain associated with these malignancies is to block off the splanchnic nerve. In 1919 Kappis described a technique by which the splanchnic nerve of the upper abdomen could be anesthetized, using a percutaneous injection. This method has been used for the relief of upper abdominal pain due to hematoma and cancer of the pancreas, stomach, gall bladder, bile duct, and colon. During the Period from November 1968 to January 1986, this method was used in 208 cases of malignancy at Severance Hospital and clinically evaluated. Patients were retroactively grouped according to the stage of development of technique used. Twelve patients who received the treatment in the period from November 1968 to March 1977 were designate4i as group 1, 26 patients from April 1977 to April 1979 as group 2, and 170 from May 1979 to January 1986 as group 3. The results are as follows: 1) The number of patients receiving splanchnic nerve block has been increasing since 1977. 2) A total of 208 patients, including 133 males and 75 females, ranging in age from 18 to 84 and averaging 51. 3) The causes of pain were stomach cancer 90, pancreatic cancer 69, and miscellaneous cancer 49 cases respectively. 4) There were 57.7% who had surgery. and 3.7% of whom had chemotherapy before the splanchnic nerve block was done. 5) These blocks were carried out with the patient in the prone position as described by Dr. Moore. For group 2 and 3, C-arm image intensifier was used. In group 1, a 22 gauze loom long needle was inserted at the lower border of the 12th rib on each aide about 7\;cm from the midline. The average distance from the midline was $6.60{\pm}0.61\;cm$ on the left side and $6.60{\pm}0.83\;cm$ on the right side in group 2, and $5.46{\pm}0.76\;cm$ on the left side and $5.49{\pm}0.69\;cm$ on the right side in group 3. The average depth to which the needle was inserted was $8.60{\pm}0.52\;cm$ on the left side and $8.74{\pm}0.60\;cm$ on the right side in group 2, and $8.96{\pm}0.63\;cm$ on the left side and $9.18{\pm}0.57\;cm$ on the right side in group 3. 6) The points of the inserted needles were positioned in the upper quarter anteriorly, 51.8% on the left side and 54.4% n the right side of the L1 vertebra by lateral roentgenogram in group 3. The inserted needle points were located in the upper and anterolateral part, of the L1 vertebra 68.5% on the left side and 60.6won the right side, on the anteroposterior rentgenogram in group 3. The needle tip was not advanced beyond the anterior margin of the vertebral body. 7) In some case of group 3, contrast media was injected before the block was done. It shows, the spread upward along the anterior mal gin of the vertebral body. 8) The concentration and the average amount of drug used in each group was as follows: In group 1, $39.17{\pm}6.69\;ml$ of 0.5% -l% lidocaine or 0.25% bupivacaine were injected for the test block and one to three days after the test block $40.00{\pm}4.26\;ml$ of 50% alcohol was injected for the semipermanent block. In group 2, $13.75{\pm}4.88\;ml$ of 1% lidocaine were used as the test block and followed by $46.17{\pm}4.37\;ml$ of 50% alcohol was injected as the semipermanent block. In group 3, $15.63{\pm}1.19\;ml$ of 1% lidocaine for test block followed by $15.62{\pm}1.20\;ml$ of pure alcohol and $16.05{\pm}2.58\;ml$ of 50% alcohol for semipermanent block were injected. 9) The result of the test block was satisfactory in all cases. However the semipermanent block was 83.3 percent of the patients in group 1 who received relief from pain for at least 2 weeks after the block, 73.1% in group 2, and 91.8% in group 3. In these unsuccessful cases, 2 cases in group 1 were controlled by narcotics but 7 cases in group 2 and 14 cases in group 3 received the same splanchnic nerve block 1 or 2 times again within 2 weeks. But, in some cases it was 3 to i months before the 2nd block and in 1 cases even 7 years. 10) The most common complications of splanchnic nerve block were hypotensino(25.5%) occasional flushing of the face, nausea, vomiting, and chest discomfort. 11) For the patients in group 3, the supplemental block most commonly used was a continuous epidural block; it was used as a diagnostic block and to afford relief from pain before the splanchnic nerve block was done. 12) The interval between the receiving of the alcohol block and discharge was from 5 to 8 days in 61 cases(31.1%) and from 1 to 2 days in 48 cases(24.5%). From the above results, it can be concluded that the splanchnic nerve block done in the prone position with pure and 50% alcohol immediately after an effective test block with 1% lidocaine under C-arm fluoroscopic control is satisfactory and reliable. How to minimize the repeat block is still a problem to be solved.

  • PDF

Study on the Utilization of the Rice-transplanter in the Double Cropping Paddy Field (이모작답(二毛作畓)에 있어서 수도이앙기(水稻移秧機)의 실용화(實用化)에 관(關)한 연구(硏究))

  • Kim, Soung-Rai;Kim, Young-Rae;Jo, Jai-Seong;Lee, Sang-Woo
    • Korean Journal of Agricultural Science
    • /
    • v.4 no.1
    • /
    • pp.94-104
    • /
    • 1977
  • In order to investigate the effects of mechanical transplanting on the rice, four rice varieties including Jo-saing Tongil were planted in case nursering bed for three times with 10 days interval beginning from April 16. Fourty days old seedlings were transplanted with rice-transplanter, and growth habits of seedlings in bed and rice plants in main field and yield were examined and summerized as follows: 1. The plant height and number of leaves of the 40 days old seedling in case nursery bed were appeared to be less than those of seedlings grown in ordinary nursery bed. In case nursery, the plant height and number of leaves of seedlings grown in case nursery were apparently higher than those of seedlings grown in upland case nursery. 2. The root of 40 days old seedlings were cut to investigate the rooting ability of seedlings, and the rooting ability of the seedlings grown in the case nursery bed were apparently lower in the rooting ability compared with the seedlings grown in ordinary nursery bed. The rooting ability of the seedlings grown in the lowland case nursery was higher than that of the seedlings grown in the upland case nursery. 3. The tip of leaves of the varieties derived from Indica type were becoming yellow and yellow-red in color 25 to 30 days after planted in the case nursery bed. Those varieties was almost stopped growth. 4. The seedlings transplanted by transplanter had shown more than five to seven days of delay in rooting, compared with the seedlings transplanted by ordinary method. The heading dates was delayed five to seven days when transplanter was used, even though the delay of heading dates was a little different depending on the varieties. 5. The yields of unhulled rice were a little lower than that of Yusin variety which was hand planted. When mechanically transplanted, the yield of Tongil variety was highest in the plot where seedlings were transplanted on May 26. When transplanted on June 15, Milyang#15 was highest in yield, indicating the importance of varietal selection in mechanical transplantation. 6. The rice transplanter could transplant from 73 to 108 seedlings per $3.3m^2$. If the seeds of rice were evenly planted in the bed, the two-row rice transplanter could be used five to six times more effectively with less than one percent of missing plant compared with the hand transplanting. This suggests that rice transplanter could be utilized in the mono cropping area. 7. Since the time of transplantings in the double-cropping area is rather limitted, mechanical transplantation might be possible without reducings yield providing better adapted varieties and improved case-nursery techniques.

  • PDF

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF

Clinical Implication of Images of Island : Based on Dreams, Sand Trays and Art Work of Four Korean Women (분석심리학적 관점에서 본 '섬' 상징의 임상적 적용 : 꿈, 모래상자, 그림작업에 출현한 섬 이미지 중심으로)

  • Jin-Sook Kim
    • Sim-seong Yeon-gu
    • /
    • v.32 no.1
    • /
    • pp.1-16
    • /
    • 2017
  • The purpose of this paper is to illustrate the nature of Objective Psyche based on island related case materials. Theoretical background starts with psychological meaning of islands, a kind affective symbol rather than cognitive image, and creation myths as the story of man's awareness of the world; Chaos as archaic identity (unconscious), islands as emergence of the ego from unconscious. In alchemical symbolism, island related to coagulatio, the operation which turns something into earth, the realm of ego. In addition, related parts of Hindu creation myths, Korean giant woman creator Sulmoonde-halmang, and legends of "Relocation of Island/Mountain" will be presented to integrate with case materials. Case A : Starts with a dream of killing a huge dragon and dead body became an island. The dragon in the water was seen as Spirit of Mercurius, the autonomous spirit, connecting of the ego with the Self. The act of killing related to Primeval being which needs to be killed to be transformed. Myths of Eskimo, The Eagle's Gift, the giant woman creator in Korea, and Marduk, the Babylonian hero will be integrated. Case B : Prior to introduce six island images in sand trays, a dream of a giant serpent (python) wound around her body will be presented to portray her situation. By relating Jung's "The Sermons to the Dead," her effort to make the solid island regarded as an act of bringing order out of original oneness (pleroma). Then stresses the importance to coagulate archetypal image Case C : A vignette of active imagination seminar where island image emerged will be described. Her endeavor of focusing on inner image related to the Hindu Creator, Cherokee creation myth, as well as Sulmoonde-halmang. As a motif of growing island, Samoan creation myth, and Legend of Mountain, Mai were incorporated. Colors in her art work regarded as expression of inner need, and importance of expressing inner feeling images as a mean to coagulate volatile emotional and spiritual content. Case D : A dream and art work of terminally ill woman; embracing the tip of the island with gushing up water will be presented. Her island and replenishing water image regard as "an immortal body," corresponds to the Philosophers' Stone for she accepted her death peacefully after the dream. Also related to "The Mercurial Fountain" in Rosarium Philosophorum, and aqua permanence, an allegory of God.

Studies on the Biological Effects of Chemosterilant, Hempa, on the Rice Weevil (Sitophilus oryzae 1.) and Transmission of Sterility (화학적 불임유기물질 Hempa가 쌀바구미(Sitophilus oryzae L.)에 미치는 생물학적 영향 및 불임성의 전달에 관한 연구)

  • Shim Jai Wook
    • Korean journal of applied entomology
    • /
    • v.12 no.1
    • /
    • pp.1-21
    • /
    • 1973
  • Some experiments were conducted to investigate the effects of the chemosterilant, hempa, on the biology of the rice weevil, Sitophilus oryzae L., and the transmission of the lethal factors in the progeny. One to three days old adult males were fed on the wheat grains treated with concentrations of 0.0625, 0.125, 0.25, and $0.5\%$ of hempa water solution. The effects of the treatment on the mortality, longevity, and the performance of oviposition were examined for the Pl generation, and the hatchability and mortality in the postembryonic development were also tested in the $F_1,\;F_2,\;BC_1,\;F_3,\;and\;BC_2$ generations to analyze the inheritance of the lethal factors. The results obtained were summarized as follows. (1) The average longevity of the treated males were ranged from 26.6 to 30.4 days, and indicated no statistical differences. (2) The mortality of the treated males were ranged between $3.3\%\;and\;13.3\%$ and showed no statistical significance. (3) The overall mean number of eggs laid by a female mated to a treated male with concentrations of 0.0625, 0.125, 0.26 and $0.5\%$ were 3.78, 4.05, 3.75 and 3.61 for the respective treatments, and they were not differ significantly from those of control which were 3.60 per female per 3 day period. The unmated female laid 1.91 in the same period, and significantly differ from those in other experimental groups. (4) The overall mean hatchability of the eggs laid by the females mated with males that had been treated with various concentrations of hempa were 86.82, 64.77, 53.47, 40.33 and $24.78\%$ for the respective concentrations of 0, 0.0625, 0.125, 0.25 and $0.5\%$. The hatchability decreased with the increasing concentrations. (5) The minimum hatchabilities were obtained from the eggs laid in the period of 10-12 days after treatment, then the hatchability increased showing some recovery. The recovery seemed to be very much delayed for the males which had been treated with the greater concentrations. Such a difference in hatchability might be related with the sensitivity of the developmental stages of the sperms, and broader spectrum in the stages and severer effects seemed to be associated with the increased concentrations. (6) The overall mean of larval mortality in the $F_l$ generation were 6.55, 17.89, 27.40, 35.42 and $52.17\%$ for the respective concentrations of 0,0.0625, 0.125,0.25 and $0.5\%$. And there was a tendency to increase in the mortality with the increase of concentrations. (7) The correlation coefficients between per cent sterile eggs and larval mortality for the experimental plots of 0.125, 0.25 and $0.5\%$ treatments showed r=+0.83 and +0.85, respectively, and it seemed to be close correlation between the lethal effects on the embryonic and post-embryonic developments. (8) Since the $SC_{50}$ of the sterile eggs was $0.133\%$ and $SC_{50}$ of the larval mortality was $0.565\%$, it was considered that tile lethal factors expressed more in the egg stages than the larval stages. (9) The ratio of female to male in the $F_l$ adults showed 100 : 125, 100 : 108 and 100 : 124 for the plots of 0.125, 0.25 and $0.5\%$ treatments, respectively. And it n·as considered that the sex ratio distortions might occur with the higher concentrations. (10) When the F, males originated 1.on the eggs had been laid by p, in the period of 16-18 days after treatment, were crossed to normal females $(BC_1)$ and made sib matings $(F_2)$, the per cent sterile eggs of the $BC_1$ generation were 13.88 and $33.04\%$ , and were 31.01 and $38.73\%$ for the $F_2$generation with the plots of 0.0625 and $0.125\%$ treatment, respectively. And these seemed to be a results of the $F_1$ individuals are carrying some chromosomal aberrations (11) The larval mortality was the highest in the $F_2$ plot and followed the female backcross plot, and the least in the male backcrosses. (12) The proportions of 1st and 2nd instar larvae among the larval development at tile 17th day after oviposition were 10.98, 27.26, 32.98 and $15.73\%$ in the normal female $\times$ normal male, $F_1$ female$\times$normal male, normal $female \;\times F_1$ male and $female \;\times F_1$ male plots, respectively. It was considered that the larval development might be delayed by the treatment in the 2nd generation. (13) Per cent larval mortality and sterile eggs were greater in the $F_2$ sib mating plots $(F_3)$ than both of $F_2$ backcrosses. Therefore, it seemed that some of the recessive lethal mutations might affect in the further generations. (14) The sterility, induced by the treatment of chemosterilant, hempa, was considered as the result of the dominant lethal mutations due to chromosomal aberrations such as translocation and/or deletion. The effects of these lethal factors seemed to be inherited tip to 3rd generation after treatment.

  • PDF

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF