• Title/Summary/Keyword: Timing of operation

Search Result 486, Processing Time 0.026 seconds

A new symbol timing algorithm for high storage density HDD (고 저장밀도 HDD를 위한 새로운 심볼동기 알고리즘)

  • 김위묵;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1554-1566
    • /
    • 1996
  • In this paper, a new symbol timing algorithm for a magnetic recording system as HDD, is proposed. Above all, the Lorentzian channel model applied, the distortion and the attenuation problems of playback signals at high speed and storage density were considered. The structure and the operation of popular data detectors for HDD were understood, and the adopted symbol timing algorithm were profoundly analyzed. On the basis of these understanding and analysis, a new symbol timing algorithm for high density HDD was proposed, and the performance evaluation of this proposed algorithm was done.

  • PDF

An estimation method for the maintenance timing of the infiltration trench (침투도랑 시설의 유지관리 시점 산정방법에 관한 연구)

  • Lee, Seung Won;Cha, Sung Min
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.1
    • /
    • pp.29-35
    • /
    • 2020
  • To manage the non-point source pollution and restore the water circulation, many technologies including infiltration or reservoir systems were installed in the urban area. These facilities have many problems regarding maintenance as their operation period becomes lengthier. The purpose of this study was to estimate the optimal maintenance timing through a long-term load test on the infiltration trench as one of the low impact development techniques. An infiltration trench was installed in the demonstration test facility, and stormwater was manufactured by Manual on installation and operation of non-point pollution management facilities from the Ministry of Environment, Korea and entered into the infiltration trench. Particle size distribution (PSD), suspended solids (SS) removal efficiency, and infiltration rate change tests were performed on inflow and outflow water. In case of the PSD, the maximum particulate size in the outflow decreased from 64 ㎛ to 33 ㎛ as the operating duration elapsed. The SS removal efficiency improved from 97 % to 99 %. The infiltration rate changed from 0.113 L/sec to 0.015 L/sec during the operation duration. The maintenance timing was determined based on the stormwater runoff requirements with these changes in water quality and infiltration rate. The methodologies in this study could be used to estimate the timing of maintenance of other low impact development techniques.

A Timing Decision Method based on a Hybrid Model for Problem Recognition in advance in Self-adaptive Software (자가-적응 소프트웨어에서 사전 문제인지를 위한 하이브리드 모델 기반 적응 시점 판단 기법)

  • Kim, Hyeyun;Seol, Kwangsoo;Baik, Doo-Kwon
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.3
    • /
    • pp.65-76
    • /
    • 2016
  • Self-adaptive software is software that adapts by itself to system requirements about the recognized problems without stopping the software cycle. In order to reduce the unnecessary adaptation in the system having the critical points, we propose proactive approach which can predict the future operation after a critical point. In this paper, we predict the future operation after a critical point using a hybrid model to deal with the characteristics of the observed data with the linear and non-linear pattern. The operation of the prediction method is determined on a timing decision indicator based on the prediction accuracy. The two main points of contributions of this paper are to reduce uncertainty about the future operation by predicting the situation after a critical point using hybrid model and to reduce unnecessary adaptation implementation by deciding a timing based on a timing decision indicator.

Flame Propagation Characteristics in a Heavy Duty Liquid Phase LPG Injection SI Engine by Flame Visualization (대형 액상 LPG 분사식 SI 엔진에서 화염 가시화를 이용한 희박영역에서의 화염 전파특성 연구)

  • 김승규;배충식;이승목;김창업;강건용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.23-32
    • /
    • 2002
  • Combustion and flame propagation characteristics of the liquid phase LPG injection (LPLI) engine were investigated in a single cylinder optical engine. Lean bum operation is needed to reduce thermal stress of exhaust manifold and engine knock in a heavy duty LPG engine. An LPLI system has advantages on lean operation. Optimized engine design parameters such as swirl, injection timing and piston geometry can improve lean bum performance with LPLI system. In this study, the effects of piston geometry along with injection timing and swirl ratio on flame propagation characteristics were investigated. A series of bottom-view flame images were taken from direct visualization using an W intensified high-speed CCD camera. Concepts of flame area speed, In addition to flame propagation patterns and thermodynamic heat release analysis, was introduced to analyze the flame propagation characteristics. The results show the correlation between the flame propagation characteristics, which is related to engine performance of lean region, and engine design parameters such as swirl ratio, piston geometry and injection timing. Stronger swirl resulted in foster flame propagation under open valve injection. The flame speed was significantly affected by injection timing under open valve injection conditions; supposedly due to the charge stratification. Piston geometry affected flame propagation through squish effects.

Design of a Timing Estimator Algorithm for 2.45GHz LR-WPAM Receiver (2.45GHz LR-WPAN 수신기를 위한 Timing Estimator 알고리즘의 설계)

  • Kang Shin-Woo;Do Joo-Hyun;Park Tha-Joon;Choi Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.3A
    • /
    • pp.282-290
    • /
    • 2006
  • In this paper, we propose an enhanced Timing Estimator algorithm for 2.45GHz LR-WPAN receiver. Because an expensive and highly efficient oscillator can't be used for low-cost implementation, a Timing Estimator algorithm having stable operation in the channel environment with center frequency tolerance of 80 ppm is required. To enhance the robustness to frequency offset and the stability of receiver performance, multiple delay differential filter is adopted. By utilizing the characteristic that the correlation result between the output signal of Multiple delay differential filter and reference signal is restricted on the In-phase part of the correlator output, a coherent detection scheme instead of the typical noncoherent one is adopted for Timing Estimator. The application of the coherent detection scheme is suitable for LR-WPAN receiver aimed at low-cost, low-power, and low-complexity, since it can remove performance degradation due to squaring loss of I/Q squaring operation and decrease implementation complexity. Computer simulation results show that the proposed algorithm achieved performance improvement compared with the differential detection-based noncoherent scheme by 2dB in average.

Study on Timing Failures in Cyber-Physical Systems

  • Kong, Joon-Ik
    • International journal of advanced smart convergence
    • /
    • v.11 no.3
    • /
    • pp.56-63
    • /
    • 2022
  • Cyber-physical systems (CPSs) can solve real problems by utilizing closely connected resources in the cyber world. Most problems arise because the physical world is uncertain and unpredictable. To address this uncertainty, information pouring from numerous devices must be collected in real-time, and each interconnected device must share the information. At this time, CPS must meet timing-related techniques and strict timing constraints that can deliver accurate information within predefined deadlines in order to interact closely beyond simply connecting the cyber and physical worlds. Timing errors in safety-critical systems, such as automobiles, aviation, and medical systems, can lead to catastrophic disasters. In this paper, we classify timing problems into two types: real-time delay and synchronization problems. The results of this study can be used in the entire process of CPS system design, implementation, operation, verification, and maintenance. As a result, it can contribute to securing the safety and reliability of CPS.

Study of Loss of Free Flap and Safer Timing of the Operation in Electrical Injury (전기화상에서 시행한 유리피판의 소실과 재건시기에 대한 연구)

  • Chung, Eui Young;Lee, Jong Wook;Koh, Jang Hue;Seo, Dong Kuk;Chung, Chan Min;Jang, Young Chul;Oh, Suk Joon
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.567-572
    • /
    • 2005
  • An electrical burn used to result in the damage of the skin and underlying deep soft tissue injury. Thus, in order to preserve devitalizing tissues and promote the structural survival free flaps with ample blood supply are frequently employed. However, early unpredictable vascular injury and progressive tissue necrosis may cause the free flaps full of hazards. We applied 50 free flaps upon 41 acute electrical burn cases between 1998 and 2004. Injured areas, timing of operation and causes of flap loss were studied. The victim's ages ranged from 13 to 60 years. (an average 37.8 years) Thirteen out of 50 free flaps were lost totally: three cases were due to arterial insufficiency and ten venous congestion. Total loss of flaps were observed in 5 of 12 cases in the postoperative 3 weeks, 6 of 20 cases between 3 and 6 weeks and 2 of 18 cases after 6 weeks. In three of 12 cases the free flap was lost partially in the postoperative 3 weeks, 4 of 20 cases between 3 and 6 weeks and 1 of 18 cases after 6 weeks. The result was statistically significant by a T-test (p<0.05). This study showed that timing of the operation is accountable for the loss of free flap. It is most important to conduct the free flap procedure on an electrical injury at the time when the recipient vessel is definitely discernible and intact so as to minimize the loss of flap and spare the structures.

Computer Simulation of Fuel States and Spark Timing in Engine Model (엔진모델에서의 연료상태와 점화시기의 컴퓨터 해석)

  • Lee, Deog-Kyoo;Kim, You-Nam;Park, Hee-Chul;Woo, Kwang-Bang
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.89-93
    • /
    • 1989
  • In this paper, a mathematical engine model based on the actual engine operation is formulated to be adapted for the evalution and development of engine control system. In the model the classification of fuel paticle siza is considered. The model is simulated through the mathematical interpretation of intake manifold in the rapidly-accerated state. The spark-timing is analyzed with respect to engine r.p.m. The result shows that the model behaves similar performance to the actual engine operation and the spark-timing is very important to the characterization of engine r.p.m..

  • PDF

A Study on the Reduction of $NO_x$ Emission from Dual Fuel Engine for Co-generation System (열병합발적용 Dual Fuel Engine의 질소산화물 배출저감에 관한 연구)

  • 정일래;김용술;심용식
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.31-40
    • /
    • 1991
  • This study shows the correlation between $NO_x$ emission in the exhaust gas and various operation factors of dual fuel engine for Co-generation system. General tendency was shown that the thermal efficiency was lowered by the change of operation factors. However these were not confirmed on this experiment. Increasing T4 temperature (exhaust gas temperature at turbo-charger inlet) reduces $NO_x$ emission rate. The higher T4 temperature requires lower excess air as the excess air ratio is controlled by T4 temperature on gas mode operation. Another tendency was that $NO_x$ emission rate is reduced in case of increasing boost air temperature, quantity of pilot oil or bypassing flue gas through the exhaust gas boiler. The diameter of the fuel injection nozzle was changed smaller than design value and the injection timing was readjusted. Thus $NO_x$ emission rate could be reduced as retarding injection timing and changing hole diameter of fuel injection nozzle, however maxium engine out-put was decreased by changing fuel nozzle on the diesel mode operation.

  • PDF

An Operating Circuits Design for preventing Electrostatic Discharge in Liquid Crystal Displays

  • Jo, Jo-Yeon;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.674-676
    • /
    • 2008
  • An electrostatic discharge (ESD) or a noise supplied from the outside has an effect on communication between the timing controller (TCON) and the memory element (EEPROM) through the interface between the timing controller and the memory element in liquid crystal displays (LCD). Therefore, we must apply ESD protection methods to LCD operating circuits for a normal operation. Our ESD protection circuit is to prevent from bi-directional communication errors between TCON and EEPROM due to an electrostatic discharge (ESD).

  • PDF